• Title/Summary/Keyword: bone stiffness

Search Result 103, Processing Time 0.025 seconds

An Exploration on Prescription of Resistance Training for Geriatric Physical Therapy (노인물리치료를 위한 저항트레이닝 처방에 대한 탐색)

  • Shin Hong-Cheul;Jeong Dong-Hyuk
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.61-81
    • /
    • 2003
  • There can be little dissension that the ultimate goal of all physical therapy interventions with the elderly is to restore or maintain the highest level of function possible for the individual. Whenever physical therapists take on this challenge, they assist elders in maintaining their identities as competent adults. Advancing age is associated with profound changes in body composition, including increased fat mass, decreased fat-free mass(particularly muscle), decreased total body water and decreased bone density. Along with these changes in body compositions, and perhaps as a direct result of them, elderly people have lower energy needs, reduced strength and functional capacity and a greatly increased risk for such diseases as noninsulin-dependent diabetes mellitus and osteoporosis. Resistance training is considered a promising intervention for reversing the loss of muscle function and the deterioration of muscle structure that is associated with advanced age. This reversal is thought to result in improvements in functional abilities and health status in the elderly by increasing muscle mass, strength and power and by increasing bone mineral density. In the past couple of decades, many studies have examined the effects of Resistance training on risk factors for age-related diseases or disabilities. We have explored the positive and negative aspects of older adults' participation in resistance training programs. The benefits to older adults are reported to be increased strength, endurance, muscle capacity, and flexibility; more energy; and improved self-image and confidence. The negative aspects include some pain or stiffness and other nonspecific problems. The positive and negative aspects of resistance training are therefore very similar to those in younger populations. Scientific investigations over the past 10 years have demonstrated that resistance training can be safely and successfully implemented in older populations. Even the frail and very sick elderly can benefit and improve their quality of life. Proper design and progression of a resistance training program for older adults is vital to optimal benefits from resistance exercise. The results of data provided by this research on resistance training for health shows that there is enough existing evidence to conclude that resistance training, particularly when incorporated into a comprehensive fitness program, can offer substantial health benefits which can be obtained by persons of all ages. These benefits, including improvements in functional capacity, translate into an improved quality of life.

  • PDF

Segmental Resection and Rotationplasty of Malignant and Aggressive Bone Tumors Around Knee (슬관절 주위 악성 및 침윤성 골종양의 분절 절제술 후 회전 성형술)

  • Hahn, Soo-Bong;Park, Hong-Jun;Kim, Hyoung-Sik;Kim, Sung-Hun;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.2
    • /
    • pp.51-58
    • /
    • 2001
  • Purpose : In patients having malignant and aggressive bone tumors around knee joint requiring amputation, segmental resection and rotationplasty were performed and the clinical results were analyzed. Materials and Methods : Twenty-six patients underwent segmental resection and rotationplasty between February 1988 and June 1994, because limb salvage with tumor prosthesis after removal of tumor was impossible. The mean follow-up of malignant tumors was 57(6~120) months and the average age of patients was 21.4(5~37) years old. Out of 26 patients, there were 18 osteosarcoma(${\geq}$stage IIB), 2 synovial sarcoma, and 6 giant cell tumor. Results : Clinical results were evaluated by the Shriner's rating system. Four patients were excluded due to death or amputation and remaining 22 patients were included for assessment. Eighteen patients had excellent result, 3 good, and 1 fair. Range of motion of ankle joint was -11(dorsiflexion)~80(plantarflexion) degrees and daily walking activity with prosthesis was possible. Local recurrence developed in 2 patients and distant metastasis in 10. Early complications had 3 thrombosis and 1 sepsis, and late complications had 6 nonunion, 2 malrotation and 1 stiffness of ankle joint. Conclusion : Rotationplasty which is functionally excellent may serve as an effective partial limb salvage procedure, especially in patients less than 10 years old that lower extremity discrepancy or loosening tumor prosthesis due to enlargement of medullary cavity are anticipated or amputation is inevitable for wide resection margin.

  • PDF

Practicability Strength Assessment of a Bone Metallic Plate at the Femur Fixation (대퇴골(Femur)고정용 골 금속판 제작 및 강도 평가)

  • Kim, Jeong-Lae;Ahn, Chang-Sik;Seo, Byoung-Do
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Study was developed the metallic plate for fixation in the femur fracture and plates has a firm place in fracture treatment. This plates can be stabilized for fracture fixation as well as biological and dynamical device. The device's designation and sizing has a optimization with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. The bending strength of the curved metallic long plate has to evaluate a 11,000N and the bending strength of the curved metallic short plate has to evaluate a 6,525N. This see the X-ray image of bending angle made certain of 15$^{\circ}$ at number 2 and same 82.87$^{\circ}$ at number 2, 4, 5, 7, 8, 9, 10 by outside angle, and confirmed 25.26$^{\circ}$ at number 3, 3.68$^{\circ}$ at number 6, 15.64$^{\circ}$ at number 9 by inside angle. This study shows that keep up the metallic plate for fixation in the femur fracture through X-ray Image and the device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture. Short plate have a wrapping of femur and long plate have to preserve a pole of femur.

Brachymetatarsia of the First Metatarsal treated by Callotasis (가골 신연술로 치료한 제 1 중족골 단축증)

  • Lee, Keun-Bae;Kim, Byung-Soo;Park, Yu-Bok;Moon, Eun-Sun;Choi, Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.2
    • /
    • pp.140-145
    • /
    • 2005
  • Purpose: To analyze the outcome of metatarsal lengthening of first brachymetatarsia by callotasis using an external fixator. Materials and Methods: Between January 1998 and February 2004, 10 patients (17 cases) were reviewed. The mean age at operation was 17.3 years. Seven patients had bilateral first brachymetatarsia and eight patients had combined 4th brachymetatarsia. The operations were performed with a monoexternal fixator, and distraction was started at a rate of 0.75 mm/day after 7 days. The radiographic results were evaluated by lengthening amount and percentage, fixation time, and healing index. Complications and AOFAS score were evaluated. Results: The average lengthening amount was 17.7 mm and the average lengthening percentage was 43.4%. The external fixation time was 107 days and average healing index was 69.8 days/cm. The evaluation according to AOFAS score was excellent in 12 cases and good in 5 cases. Complications were 4 cases of hallux valgus, 4 of metatarsophalangeal joint stiffness, 3 of medial angular deformity, 3 of pes cavus, 2 of pin breakage, 2 of pin site infection, and 1 of skin hyperpigmentation. Conclusion: Callotasis for 1st brachymetatarsia is a very useful treatment method with high patient satisfaction, excellent healing rate and early ambulation without bone graft. Nevertheless, great care must be taken to minimize the various possible complications.

  • PDF

Open Treatment of Anterior Impingement Syndrome of the Ankle in Elite Level Soccer Players (축구 선수에서 발생한 족관절 전방 충돌 증후군의 개방적 수술의 치료 결과)

  • Lee, Kyung-Tai;Young, Ki-Won;Kim, J-Young;Kim, Eung-Soo;Cha, Seung-Do
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.76-80
    • /
    • 2004
  • Purpose: We assessed the results of open treatment of anterior impingement syndrome of the ankle in elite level soccer players and concomitant injuries were idenfied. Materials and Methods: We retrospectively reviewed twenty one elite level soccer players diagnosed with anterior impingement syndrome who underwent open debridement between January 1997 and January 2002. All were men and the mean age at the operation was 21 years (range 16 to 27). The mean follow-up duration was 31 months (13 to 71). Concomitant abnormalities were idenfied through physical examination, bone scan and MRI. On a preoperative lateral radiograph, patients were classified according to McDermott's stage. Anteromedial or anterolateral approach was used at the operation and osteophyte was removed with osteotome and rongeur. When chronic ankle instability was accompanying, we performed Modified Brostrom-Gould procedure and for osteochondral lesion, multiple drilling was applied. The Ogilvie-Harris scoring system was used as a clinical scale to evaluate pain, swelling, stiffness and limitation of activity. The results were scored as excellent (15 to 16 points), good (13 to 14) and otherwise unsatisfactory. The time to return to full activity including sports activity was determined. Results: Eighteen of twenty one patients had an excellent outcome. Three patients were graded unsatisfactory and two of them abandoned their career due to the persistence of residual pain. Concomitant abnormalities were found including twelve cases of chronic ankle instability, three cases of osteochondral lesion and two cases of flexor hallucis longus tendinitis. Conclusion: Open debridement was successfully applied to the elite level soccer player with anterior impingement syndrome of the ankle. Considerable coexistence of other abnormalities such as chronic ankle instability may encourage us to consider additional operative procedure.

  • PDF

Hook Plate Fixation for Isolated Greater Tuberosity Fractures of the Humerus

  • Lee, Kyoung-Rak;Bae, Ki-Cheor;Yon, Chang-Jin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.222-229
    • /
    • 2017
  • Background: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. Methods: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. Results: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were $156.7^{\circ}$, $152.2^{\circ}$, $61.1^{\circ}$, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. Conclusions: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.

Development and validation of a computational multibody model of the elbow joint

  • Rahman, Munsur;Cil, Akin;Johnson, Michael;Lu, Yunkai;Guess, Trent M.
    • Advances in biomechanics and applications
    • /
    • v.1 no.3
    • /
    • pp.169-185
    • /
    • 2014
  • Computational multibody models of the elbow can provide a versatile tool to study joint mechanics, cartilage loading, ligament function and the effects of joint trauma and orthopaedic repair. An efficiently developed computational model can assist surgeons and other investigators in the design and evaluation of treatments for elbow injuries, and contribute to improvements in patient care. The purpose of this study was to develop an anatomically correct elbow joint model and validate the model against experimental data. The elbow model was constrained by multiple bundles of non-linear ligaments, three-dimensional deformable contacts between articulating geometries, and applied external loads. The developed anatomical computational models of the joint can then be incorporated into neuro-musculoskeletal models within a multibody framework. In the approach presented here, volume images of two cadaver elbows were generated by computed tomography (CT) and one elbow by magnetic resonance imaging (MRI) to construct the three-dimensional bone geometries for the model. The ligaments and triceps tendon were represented with non-linear spring-damper elements as a function of stiffness, ligament length and ligament zero-load length. Articular cartilage was represented as uniform thickness solids that allowed prediction of compliant contact forces. As a final step, the subject specific model was validated by comparing predicted kinematics and triceps tendon forces to experimentally obtained data of the identically loaded cadaver elbow. The maximum root mean square (RMS) error between the predicted and measured kinematics during the complete testing cycle was 4.9 mm medial-lateral translational of the radius relative to the humerus (for Specimen 2 in this study) and 5.30 internal-external rotation of the radius relative to the humerus (for Specimen 3 in this study). The maximum RMS error for triceps tendon force was 7.6 N (for Specimen 3).

The Clinical Study on 34 Admission Patients to Oriental Medical Hospital due to Traffic Accident (한방병원에 입원한 교통사고 환자 34명에 대한 임상적 고찰)

  • Cho, Sung-Woo;Go, Kyung-Hoon;Nam, Jung-Hun;Kim, Bong-Hyun;Lee, In-Seon
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.1 no.2
    • /
    • pp.101-109
    • /
    • 2006
  • Objective: The purpose of this study is finding tendencies admission patients to orient medical hospital due to Traffic Accident. Method: We studied 34 cases who were admitted in Dong-eui University Oriental Hospital from 1st, December, 2003 to the 30st, May, 2005. And we came to some conclusion about clinical tendencies as follows. Results and Conclusions: 1. Women had occupied more than men, And 10 persons in 30th were the most distribution of age. 2. Most patients used western medical hospital as primary hospital and after several days they started to search for orient medical treatments. 3. In the diagnosis through radiological test, cervical spine sprain was most(19 cases, 55.6%). The others were lumbar spine sprain(14 cases, 41.2%), fracture of other bone{4 cases, 11.8%), fracture of spine(3 cases, 8.8%), Intercranial hemorrhage(3 cases, 8.8%). 4. In chief complaint, low back pain was most(19 cases, 55.9%), The others were neck stiffness(17 cases, 50.0%), headache(13 cases, 38.2%), lower limb pain(9 cases, 26.5%). 5. Simple Disease had higher than complex disese at effective rate. 6. Both $43{\sim}60$ days admission and $15{\sim}21$ days admission were the best effective. $8{\sim}14$ days admission was next effective. 7. Early visit made more effective.

  • PDF

Finite Element Analysis of Sound Transfer Characteristics for Middle Ear (유한요소 모델을 이용한 중이의 소리전달 특성 해석)

  • Gal, Young-Min;Baek, Moo-Jin;Lee, Doo-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1563-1571
    • /
    • 2011
  • In this study, we developed a finite element model of the human middle ear has been developed to calculate itsfor sound transfer characteristics calculation. We usedThe geometric data forof ossicles, obtained byfrom micro-CT scanning, was used in order to develop the middle- ear FE model. A right- side temporal bone of a Korean cadaver was used for the micro-CT scanning. The developed FE model includes three ossicles, the tympanic membrane, ligaments, and muscles. We calculated theA sound transfer function from the tympanic membrane to the stapes footplate was calculated. The sound transfer function calculated vias of the FE model shows good agreement with measured responses over the 10- kHz frequency band. To measureidentify the sensitivityies of the middle- ear function due to material property variation, we studied several parameters studies have been fulfilled using the middle ear FE model. TAs a result the stiffness property of the incudostapedial joint had the greatest influence onwas the most influential to the middle- ear sound transfer function among the parameters.

Implementation of curved type a metallic plate system at the Bone contact (골 접촉 곡선형 금속 고정 시스템 구현)

  • Kim, Jeong-Lae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.285-292
    • /
    • 2007
  • This study was developed the metallic plate for fixation in the femur fracture for the orthopedic region and rigid fixation with plates has a firm place in fracture treatment. Most plates can be used for rigid as well as biological and dynamical fracture fixation. The device's designation and sizing has a specific with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. Short plate have a wrapping of femur and long plate have to preserve a pole of femur. The bending strength of the curved metallic long plate has to evaluate a 11,000N and The bending strength of the curved metallic short plate has to evaluate a 6,525N. The tensile stress through to press a plate is $1573N/m^2\;and\;1539N/m^2$. The device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture.

  • PDF