• Title/Summary/Keyword: bone screw fixation

Search Result 180, Processing Time 0.021 seconds

Treatment of Fifth Metatarsal Base Fracture Using Tension Band Wiring (인장대 강선 고정술을 이용한 제5 중족골 기저부 골절의 수술적 치료)

  • Ahn, Jong-Kuk;Chung, Hyung-Jin;Bae, Su-Young;Park, Ji-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.1
    • /
    • pp.18-21
    • /
    • 2011
  • Purpose: To evaluate the clinical and radiological results of internal fixation with tension band wiring for the fracture at the base of fifth metatarsal bone. Materials and Methods: From January 2008 to December 2009, 15 cases with displaced fracture at the base of fifth metatarsal were analyzed and average follow up period was 13.8 months. Lawrence classification was used to classify fracture type. We evaluated clinical results by American Orthopedic Foot Ankle Society (AOFAS) midfoot score and radiological results by union time. Complications was also checked. Results: According to classification, zone I fracture were 11 cases and zone II fracture were 4 cases. Bony union was achieved in all cases after 7 weeks. In the final follow-up, average AOFAS score was 94. There were no complications except hardware irritation. Conclusion: Satisfactory results were obtained after tension band wiring for the fifth Metatarsal base fracture in zone I fracture or comminuted zone II fracture for which it is not easy to be fixed with screw.

Anterior and Posterior Stabilization by One Stage Posterolateral Approach in the Unstable Fracture of Thoracolumbar and Lumbar Spine

  • Lee, Young-Min;Cho, Yang-Woon;Kim, Joon-Soo;Kim, Kyu-Hong;Lee, In-Chang;Bae, Sang-Do
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.1
    • /
    • pp.22-27
    • /
    • 2006
  • Objective : The purpose of this study is to investigate the clinical results of anterior and posterior stabilization by one stage posterolateral approach for the unstable fracture of thoracolumbar and lumbar spine. Methods : By posterolateral approach with curved skin incision, unilateral facet and pedicle were removed. Through this route, corpectomy was performed, and then this space was replaced with mesh cage filled up with autologous bone graft. Both side pedicle screw fixation was followed to upper and lower levels. Results : Six of seven patients of this study showed neurological improvement. The other one patient showed no neurological change. One patient had postoperative infection, another patient had postoperative kyphosis. The other patient had epidural hematoma on operation site after surgery. And all patinets on this study made to have spinal stability except one patient happened postoperative kyphosis. Conclusion : In the unstable fracture of thoracolumbar and lumbar spine, one stage anterior and posterior stabilization and fusion by posterolateral approach seems to be an effective procedure, if we have more care and supplementation.

Treatment of hearing loss due to temporomandibular joint disorders: Case Report (턱관절 장애로 인한 청각장애의 치료: 증례보고)

  • Kang, Dong-Woo;Kim, Young-Kyun
    • The Journal of the Korean dental association
    • /
    • v.57 no.4
    • /
    • pp.204-212
    • /
    • 2019
  • Introduction : Patients with temporomandibular disorder may have various ear-related symptoms. If an excessive load is applied to the ear area due to the skeletal shape of the mandibular condyle or malposition of the disc, an auditory problems may occur. Case report : The patient was referred to our clinic due to the suspicion of temporomandibular disorder from the local otorhinolaryngology clinic. A few days ago, his right ear could not be heard. MRI showed that the left TMJ disc was anterior displacement with reduction, the right TMJ disc was anteromedial displacement without reduction. Also Right mandibular condyle showed sclerotic bone change, subchondral cyst and was compressing the frontal wall of the ear on MRI view. Right TMJ arthroplasty was done under the diagnosis of right TMJ osteoarthritis and osteochondroma. Postoperative intermaxillary fixation was done with SAS screw and elastics for 2 weeks. One month after the operation, hearing and TMJ discomfort were recovered without any complications. Conclusions As seen in this case, hearing loss due to benign tumor-like lesions of the temporomandibular joint should be treated surgically to restore the TMJ function and hearing.

  • PDF

Effects of Intramedullary K-wire Insertion on Femoral Lengthening in Canine with Monolateral External Fixator (단측성 외고정 기구를 이용한 개의 대퇴골 신연에 있어서 골수강내 K-강선 삽입의 효과)

  • Hwang, Jae-Min;Kim, Young-Ki;Chin, Hee-Tec;Seok, Seong-Hoon;Lee, Hee-Chun;Koh, Phil-Ok;Chang, Hong-Hee;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.291-299
    • /
    • 2006
  • During long bone lengthening, there are many disadvantages including axial deviation, malalignment and re-fracture which are commonly encountered inspite of its proven abilities. To study the effects of intramedullary K-wire application on the lengthening of long bone, ten skeletally mature mongrel dogs were separated into two groups(Group I, II). Right femurs of group I(5 dogs) were fixed with only monolateral external fixator after subperiosteal osteotomy. Right femurs of group II(5 dogs) were fixed with mono lateral external fixator and intramedullary K-wire after subperiosteal osteotomy. Lengthening was started at 7 days after the surgery with the rate of 0.5 mm per day for 5 weeks and the dogs were sacrificed after 15 weeks postoperatively to examine histologic differences and evaluate bone mineral density. Radiographic examination at an interval of two weeks was done to evaluate the type of callus formed and to analyze complications including instability of external skeletal fixation and axial deviation. Bone mineral density at the lengthened area and contralateral nonlengthened area were measured using quantitative computerized tomography. Histological examination of regenerated bone was performed using Masson's trichrome stain method. The radiographs demonstrated poor callus formation, higher incidence of axial deviation and screw loosening in the group I compared to the group II. The bone mineral density at the lengthened area in the group II was higher than that of the group I(P<0.05). Histological examination showed that the new bone trabeculae in the group II were greater than that of the group I. In conclusion, the combination of monolateral external fixator and intramedullary K-wire can prevent pin loosening, axial deviation and reduce healing period in dogs.

Wire or Hook Traction for Reducing Zygomatic Fracture

  • Ahn, Hee Chang;Youn, Dong Hyun;Choi, Matthew Seung Suk;Chang, Jung-Woo;Lee, Jang Hyun
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.131-135
    • /
    • 2015
  • Background: Variable methods have been introduced for reduction of the zygomatic fractures. The Dingman elevator is used widely to reduce these fractures but is inappropriate in certain types of fractures which require atypical traction vectors. We introduce and examine an alternate method of reducing zygomatic fractures using wire and hook traction. Methods: A retrospective study was performed for all zygomatic fracture patients admitted between 2008 and 2014. Medially rotated fractures were reduced by using a wire looped through an intermaxillary screw secured on the medial side of the zygoma. Laterally rotated fractures were reduced using a hook introduced through an infrazygomatic skin incision. Results: No accidental bleeding or incomplete reduction was observed in any of the cases. Postoperative imaging demonstrated proper reduction immediately after the operation. Follow-up computed tomography study at 1 month after operation also demonstrated proper reduction and healthy union across the previous site of fracture. Conclusion: The hook and wire method allowed precise application of traction forces across zygomatic fractures. The fractured bone fragment could be pulled in the direction precisely opposite to the vector of impact at the time of trauma. Soft tissue damage due to dissection was minimized. In particular, this method was effective in reducing rotated bone fragments and can be an alternative option to using the zygoma elevator.

Efficacy of Calcium Sulfate Pellets as Bone Graft Substitute in Lumbar Posterolateral Fusion - Preliminary Report - (요추부 후측방 유합술에서 골편대체물로서 황산칼슘의 효과에 대한 연구)

  • Lee, Seung Ku;Kim, Choong Hyun;Cheong, Jin Hwan;Bak, Koang Hum;Kim, Jae Min;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.5
    • /
    • pp.605-610
    • /
    • 2001
  • Objective : The authors investigated the efficacy of the calcium sulfate(OsteoSet$^{(R)}$ pellets) as an autograft extender when used to perform posterolateral lumbar fusions. Patients and Methods : Twenty patients who underwent lumbar posterolateral arthrodesis for various spinal diseases between October 1999 and March 2000 were evaluated. Arthrodesis was performed by transpedicular screw fixation and bone grafting with a mixture of autograft + calcium sulfate in a 1 : 1 ratio. At time intervals of 1, 2, 3, and 6 months, postoperative radiographs were obtained to review the resorption of calcium sulfate and the evidence of fusion. A modified Lenke scale was used to assess the status of the fusion. Results : At 2 months after operation, the average modified Lenke scale score for the OsteoSet$^{(R)}$ pellets group was 3.8. However at 6 months after operation, the average modified Lenke scale score for the OsteoSet$^{(R)}$ pellets group was 1.8. Resorption of calcium sulfate pellets was revealed in all cases at 6 months after surgery. Conclusion : It is presumed that a combination of calcium sulfate and autograft can play a role as an effective autograft extender in the posterolateral spinal fusion.

  • PDF

Orbital wall restoration with primary bone fragments in complex orbital fractures

  • Jong Hyun Park;Dong Hee Kang;Hong Bae Jeon;Hyonsurk Kim
    • Archives of Craniofacial Surgery
    • /
    • v.24 no.2
    • /
    • pp.52-58
    • /
    • 2023
  • Background: Complex orbital fractures are impure orbital fractures because they involve the orbital walls and mid-facial bones. The author reported an orbital wall restoration technique in which the primary orbital wall fragments were restored to their prior position in complex orbital fractures in 2020. As a follow-up to a previous preliminary study, this study retrospectively reviewed the surgical results of complex orbital wall fractures over a 4-year period and compared the surgical outcomes by dividing them into groups with and without balloon restoration. Methods: Data of 939 patients with facial bone fractures between August 2018 and August 2022 were reviewed. Of these, 154 had complex orbital fractures. Among them, 44 and 110 underwent reduction with and without the balloon technique respectively. Pre- and postoperative Naugle exophthalmometer (Good-Lite Co.) scales were evaluated. The orbital volume and orbital volume ratio were calculated from preoperative and 6 months postoperative computed tomography images. Results: Among 154 patients with complex orbital fractures, 44 patients underwent restoration with the balloon technique, and 110 patients underwent restoration without it. The Naugle scale did not differ significantly between the two groups, but the orbital volume ratio significantly decreased by 3.32% and 2.39% in groups with and without the balloon technique and the difference in OVR was significantly greater in patients in the balloon restoration group compared with the control group. Postoperative balloon rupture occurred in six out of 44 cases (13.64%). None of the six patients with balloon rupture showed significant enophthalmos at 6 months of follow-up. Conclusion: The balloon rupture rate was 13.64% (6/44 cases) with marginal screw fixation, blunt screws, and extra protection with a resorbable foam dressing. Furthermore, we restored the orbital wall with primary orbital fragments using balloon support in complex orbital wall fractures.

Total Hip Arthroplasty in Protrusio Acetabuli: A Systematic Review

  • Sajid Ansari;Kshitij Gupta;Tushar Gupta;Balgovind S. Raja;Pranav J.;Roop Bhushan Kalia
    • Hip & pelvis
    • /
    • v.36 no.1
    • /
    • pp.12-25
    • /
    • 2024
  • Protrusio acetabuli, or abnormal protrusion of the femoral head into the acetabulum, requires performance of a total hip arthroplasty (THA) for which various reconstruction techniques and outcomes have been described. The aim of this systematic review is to provide a comprehensive analysis of the current evidence, evaluate treatment efficacy, compare surgical techniques, and identify topics for future research along with improving evidence-based decision-making, improving patient outcomes in the management of this condition. A thorough systematic review of the PubMed, Embase, Cochrane Library databases, and Scopus library was conducted, and articles describing techniques of THA for treatment of protrusion acetabuli were extracted. The initial search generated 751 results. After exclusion, 18 articles were included. Of these, eight were prospective studies and 10 were retrospective. Surgery was performed on 783 hips with a mean age of 60 years; 80% of females who mostly had inflammatory arthritis were followed up for 8.86 years (range, 2-15.4 years). Good outcomes have been achieved with THA using uncemented cups with bone graft; however, no conclusion could be drawn with regard to the femoral side. It can be concluded that the concept of restoration of the anatomical hip center of rotation is paramount for good outcome and better survival of the implant is important when using uncemented cups with a bone graft. In addition, screw augmentation for fixation is not recommended unless absolutely necessary. The most common complications were aseptic loosening and heterotopic ossification. While the former required revision, conservative management was administered for the latter.

Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix) (금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교)

  • Lim Hong Chul;Wang Joon Ho;Rho Young Jin;Hwang Jin Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.206-214
    • /
    • 2003
  • Purpose : To analysis each clinical results after arthroscopic ACL reconstruction with using variable fixatives which are metallic and bioabsorbable interference screw, and RIGIDfix. Therefore, We reported the clinical reliability and safty of ACL reconstruction using RIGIDfix. Materials and Methods : We evaluated the results of arthroscopic ACL resconstruction with patellar tendon autograft among three groups, of which group 1 is used metal interference screw for 44 patients, group 2 used bioabsorbable interference screw for 47 patients, group 3 used RIGIDfix for 42 patients. We compared the clinical results by physical examination (anterior drawer test, Lachman test and pivot shift test), Lysholm score and KT-2000 arthrometer and compared the radiological results by measurement of tunnel and fixatives position and widening and by MRI findings. We analyzed the results by SAS 8.2 Ducan. Tukey and paired t-test Results : Physical instability was in 5 cases, which group 2 had 4 cases and group 3 had 1 case. Lysholm score improved from 59.8. 64.4, 61 to 90.1, 92.3. 92. KT-2000 arthrometer instability improved from 9.20, 10.2, 9.5 to 1.43. 1.62. 2.00 (p=0.478). Radiologically, all cases had excellent tunnel position and cyst change was observed the 8 cases in the group 2, but, all 20 cases 2nd MRI had signal change of peri-fixatives. But, no correlation of clinical results. Conclusion : No statistical difference of clinical instability was found among three groups. And femoral tunnel changes were much observed in group I, II than III. We considered the RIGIDfix has much advantages because the short operation time, better fixation position and much bone contact surface. But, further long term follow up study was needed.

  • PDF

Long-term Stability after Reduction of Mandible Fracture by Keyhole Plate: Evaluation at the Time of Plate Removal

  • Cheon, Kyeong-Jun;Cho, Seoung-Won;Jang, Won-Seok;Kim, Ju-Won;Yang, Byoung-Eun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.6.1-6.6
    • /
    • 2020
  • Background: Various types of miniplates have been developed and used for the reduction of facial bone fractures. We introduced Yang's Keyhole (YK) plate, and reported on its short-term stability. The purpose of this study was to evaluate the long-term stability of the YK plate, as a follow-up study, by examining the patients who had used the YK plate among the patients with the reduction of mandible fractures and who visited for plate removal. Methods: We reviewed the medical records of 16 patients who underwent mandibular fracture fixation using a YK plate (group I) and 17 patients who underwent mandibular fracture fixation using a conventional plate (group II). Assessment was then made on malunion, occlusal stability, discomfort during the application, and clinical symptoms. Results: From January 2015 to December 2017, a total of 36 patients underwent mandibular fracture surgery using a YK plate. A total of 16 patients received plate removal. Among them, 15 were male and 1 female. The average age was 26 years. The applied surgical sites were the 12 on mandibular angle, 4 on mandibular symphysis, and 2 on subcondyle. The application period of YK plate was an average of 335 days. During the same period, 45 people underwent surgery on the conventional plate. A total of 17 patients received plate removal. Among them, 15 were male and 2 females. The average age was 36 years. The applied surgical sites were the 8 on mandibular angle, 4 on mandibular symphysis, and 2 on subcondyle. The application period of the conventional plate was an average of 349 days. No malocclusion occurred at the time of removal, and occlusion was stable. No patient complained of joint disease or discomfort. Conclusion: The YK plate system, in which the screw was first inserted and the plate was applied, for clinical convenience did not cause any particular problem and no significant difference from the conventional plate.