• Title/Summary/Keyword: bone scan

Search Result 519, Processing Time 0.027 seconds

A Patterns of Care Study of the Various Radiation Therapies for Prostate Cancer among Korean Radiation Oncologists in 2006 (Patterns of Care Study를 위한 2006년 한국 방사선종양학과 전문의들의 전립선암 방사선치료원칙 조사연구)

  • Kim, Jin-Hee;Kim, Jae-Sung;Ha, Sung-Whan;Shin, Seong-Soo;Park, Won;Cho, Jae-Ho;Suh, Chang-Ok;Oh, Young-Taek;Shin, Sei-Won;Kim, Jae-Chul;Jang, Ji-Young;Nam, Taek-Keun;Choi, Young-Min;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2008
  • Purpose: To conduct a nationwide academic hospital patterns of the practice status and principles of radiotherapy for prostate cancer. The survey will help develop the framework of a database of Korean in Patterns of Case Study. Materials and Methods: A questionnaire about radiation treatment status and principles was sent to radiation oncologists in charge of prostate cancer treatment at thirteen academic hospitals in Korea. The data was analyzed to find treatment principles among the radiation oncologists when treating prostate cancer. Results: The number of patients with prostate cancer and treated with radiation ranged from 60 to 150 per academic hospital in Seoul City and 10 to 15 outside of Seoul City in 2006. The primary diagnostic methods of prostate cancer included the ultrasound guided biopsy on 6 to 12 prostate sites(mean=9), followed by magnetic resonance imaging and a whole body bone scan. Internal and external immobilizations were used in 61.5% and 76.9%, respectively, with diverse radiation targets. Whole pelvis radiation therapy(dose ranging from 45.0 to 50.4 Gy) was performed in 76.9%, followed by the irradiation of seminal vesicles($54.0{\sim}73.8$ Gy) in 92.3%. The definitive radiotherapy doses were increased as a function of risk group, but the range of radiation doses was wide(60.0 to 78.5 Gy). Intensity modulated radiation therapy using doses greater than 70 Gy, were performed in 53.8% of academic hospitals. In addition, the simultaneous intra-factional boost(SIB) technique was used in three hospitals; however, the target volume and radiation dose were diverse. Radiation therapy to biochemical recurrence after a radical prostatectomy was performed in 84.6%; however, the radiation dose was variable and the radiation field ranged from whole pelvis to prostate bed. Conclusion: The results of this study suggest that a nationwide Korean Patterns of Care Study is necessary for the recommendation of radiation therapy guidelines of prostate cancer.

Performance Evaluation of a Pinhole Collimator According to the Aperture Diameter (핀홀 콜리메이터 초점의 직경 크기 별 성능비교 및 평가)

  • Lee, Kwang Hun;An, Byung Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.104-109
    • /
    • 2014
  • Purpose: Conventional pinhole scintigraphy offers a high resolution and generally use for thyroid scan or bone scintigraphy. the aim of this study is to evaluate performance of each aperture according to the diameter size. Materials and Methods: In this study 2 mm, 4 mm, 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture, we acquired projection image by using SPECT for evaluating FWHM, resolution test and static image for evaluating thyroid phantom test. Results: As a result of FWHM showed 2.2 mm FWHM, 3.2 mm FWHM, 5.4 mm FWHM, 7.5 mm FWHM per each aperture in the resolution test. SNR, uniformity, contrast were acquired result from thyroid phantom test comparing general image and delayed image. as a result of SNR showed 6.55, 8.47, 6.2, 5.23 in case of general image and 5.25, 5.01, 5.38, 5.82 in case of delayed image per each aperture. as a result of uniformity showed 0.152, 0.118, 0.161, 0.19 in case of general image and 0.19, 0.199, 0.185, 0.171 in case of delayed image per each aperture. as a result of contrast showed 1.31, 1.19, 1.15, 1.01 in case of general image and 1.09, 1.08, 1.04, 1 in case of delayed image per each aperture. Conclusion: Resolution and sensitivity were heavily influenced by aperture size. and also we found advantage of delayed image as a result of thyroid phantom test.

  • PDF

Study on Oneself Developed to Apparatus Position of Measurement of BMD in the Distal Radius (자체 개발한 보조기구로 원위 요골의 골밀도 측정 자세 연구)

  • Han, Man-Seok;Song, Jae-Yong;Lee, Hyun-Kuk;Yu, Se-Jong;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.419-426
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the difference of bone mineral density according to distal radius rotation and to develop the supporting tool to measure rotation angles. Materials and Methods : CT scanning and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 20 males. Twenty healthy volunteers without any history of operations, anomalies, or trauma were enrolled. The CT scan was used to evaluate the cross sectional structure and the rotation angle on the horizontal plane of the distal radius. The rotational angle was measured by the m-view program on the PACS monitor. The DXA was used in 20 dried radii of cadaveric specimens in pronation and supination with five and ten degrees, respectively, including a neutral position (zero degrees) to evaluate the changes of BMD according to the rotation. Results : The mean rotation angle of the distal radius on CT was 7.4 degrees of supination in 16 cases (80%), 3.3 degrees of pronation in three cases (15%), and zero degree of neutral in one case (9%), respectively. The total average rotation angle in 20 people was 5.4 degrees of supination. In the cadaveric study, the BMD of the distal radius was different according to the rotational angles. The lowest BMD was obtained at 3.3 degrees of supination. Conclusion : In the case of the measurement of BMD in the distal radius with a neutral position, the rotational angle of the distal radius is close to supination. Pronation is needed for the constant measurement of BMD in the distal radius with the rotation angle measuring at the lowest BMD and about five degrees of pronation of the distal radius is recommended.

  • PDF

Result of Radiation Therapy for the Lung Cancer (폐암의 방사선치료 결과)

  • Kim Joo-Young;Choi Myung-Sun;Suh Won-Hyck
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.213-225
    • /
    • 1989
  • An analysis has been made of two hundred seven patients who were treated at the department of Radiation Oncology of Korea University Hospital for lung cancer from January 1981 through December 1986. There were 137 patients of nonsmall cell carcinoma (137/207, 66%), 26 patients of small cell carcinoma (26/207, 12.5%) and 44 patients of unproven histology. By aims of treatment, there were 104 patients (104/207, 50%) treated for cure, 89 patients (89/207, 42.9%) for palliation and 14 patients treated postoperatively. In 22 out of 207 patients, chemotherapy was done with radiotherapy, 12 of which were patients with small cell carcinoma. Stage II patients were 49 (49/207, 23.6%), stage III patients were 157 (157/207, 75.8%) and one patient had an occult cancer The tumor was initial Iy measured by CAT scan and chest X-rays in the 165 (165/207, 79.7%) patients, among which 117 patients had tumor diameter more than 5cm and 48 patients less than 5cm. Radiation therapy was given with Cobalt 60 teletherapy unit and the treatment volume encompassed primary tumor and the mediastinum. For curative aim, daily tumor dose of 180 cGy was given up to the range of 5,400~6,120cGy/30~34F/6~7 week period and for palliative aim, daily tumor dose of 300 cGy was given up to the range of 3,600~4,500 cGy/12~15F/2~3 week period. Postoperatively, mediastinum was treated for total dose of 5,040 cGy/28F/5.5 week period. 123 patients (123/207, 59%) were followed up after completion of radiotherapy for 14 months to 7 years. Local tumor response to the irradiation was measured by chest X-ray taken at one month follow up and was evaluated for response rate, if they were regressed more than 50% or less than 50% of the initial tumor size. The treatment results were as follows; 1. The median survival time was 8.5 months and survival rates for 1 year, 2 year and 5 year was 25%, 3.5% and 1% of nonsmall cell lung ca of 74 evaluable patients. 2. More than 50% of local tumor response rate was obtained in about half of overall cases; 90.5% for small cell ca, 50% for squamous cell ca, 25% for adenoca and 57% for large cell ca. 3. Response rate more than 50% was seen in the 50% of the patient group with tumor diameter more than 5cm and in the 55% of those with tumor diameter less than 5cm. 4. By total raidation dose given, patient group which was given 5,400~6,120 cGy equivalent dose or higher showed tumor response rate more than 50% in 53% of the patients, whereas the group with dose less than 5,400cGy equivalent, in 25% of the patients. 5. Survival rate for 6 month, 1 year and 2 year was compared between the group of local tumor response rate more than 50% vs. group with response rate less than 50%; 74% vs. 43%, 33% vs, 23%, 10% vs. 1%, respectively. 6. Local failure was seen in 21%(44/207) of the patients, which occured mostly within 15 months after completion of radiation therapy. Distant metastases were seen in 49.7%(103/207) of the patients, of which 43 cases were found before initiation of radiotherapy. The most common metastatic sites were bone and brain. In this sutdy, 1 year,2 year and S year survival rates were somewhat poor compared to the other studies. It mainly seems to be due to the poor general status of the patients and the far-advanced stage of the disease. In nonsmall cell cancer patients who had limited local disease and had small primary tumor size, we observed better local response. In addition, dose higher than 6,000 cGy group showed better tumor control than lower dose group. Survival rate was better for the local control group. For imporvement of local control of the lung cancer and hence, the survival of the patients with lung cancer, proper radical radiotherapy with high dose for localized disease is needed. New modality of treatment such as high LET beam in radiation therapy or drugs for the advanced disease as well as early diagnosis is also needed.

  • PDF

Role of Whole Body FDG-PET in the Diagnosis of Hidden Distant Metastasis before Liver Transplantation in Patients with Primary Liver Cancer (고식적 검사로 간외 전이를 진단하지 못한 원발성 간암 환자에서 간이식 전에 시행한 전신 FDG-PET의 역할)

  • Lee, Won-Woo;Ryu, Jin-Sook;Yang, You-Jung;Kim, Jae-Seung;Yeo, Jeong-Seok;Moon, Dae-Hyuk;Lee, Sung-Gyu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.368-380
    • /
    • 2002
  • Purpose: Liver transplantation (LT), one of the therapeutic options of primary liver cancer has been suffering from recurrence caused by metastasis in 8-54% of patients. This study was performed to investigate whether FDG-PET is useful for detecting hidden metastasis in LT candidates. Materials and Methods: Twenty-six patients (male:female=23:3, mean age 55.7 years) underwent FDG-PET. Their previous conventional diagnostic studies (CDS) like abdomen US and CT, chest x-ray and CT, and bone scan were negative (n=22) or equivocal (n=4) for metastasis. Positive FDG-PET findings were confirmed by biopsy or clinical follow-up. Results: Among 4 patients with equivocal metastatic lesions on CDS, 3 had 6 hypermetabolic lesions on FDG-PET, which were confirmed as metastasis and subsequently LTs were cancelled. Of these, 5 lesions were initially negative on CDS. Remained 1 patient underwent LT with a negative FDG-PET result. Among 22 patients without metastasis on CDS, 5 had 7 hypermetabolic lesions on FDG-PET. One of these patients proved to have 2 metastatic lesions, and LT was cancelled. The other 4 patients had S hypermetabolic lesions on FDG-PET, which were confirmed as benign lesions, and 3 patients of them underwent LT. In summary, FDG-PET was useful in avoiding 4 unwarranted LT by detecting unsuspected metastatic lesions on CDS. A total of 17 patients underwent LT. In comparison with pathology, the sensitivity and specificity of FDG-PET for detecting viable primary liver cancer were 55.6% (5/9) and 87.5% (7/8), respectively. Conclusion: FDG-PET can detect additional hidden metastasis and contribute to reducing unwarranted LT in the patients with primary liver cancer.

Radiotherapy in Medically Inoperable Early Stage Non-small Cell Lung Cancer (내과적 문제로 수술이 불가능한 조기 비소세포성 폐암에서의 방사선치료)

  • Kim, Bo-Kyoung;Park, Charn-Il
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.257-264
    • /
    • 2000
  • Purpose: For early stage non-small-cell lung cancer, surgical resection is the treatment of choice. But when the patients are not able to tolerate it because of medical problem and when refuse surgery, radiation therapy is considered an acceptable alternative. We report on the treatment results and the effect of achieving local control of primary tumors on survival end points, and analyze factors that may influence survival and local control. Materials and Method : We reviewed the medical records of 32 patients with medically inoperable non-small cell lung cancer treated at our institution from June, 1987 through June, 1997. All patients had a pathologic diagnosis of non-small cell lung cancer and were not candidate for surgical resection because of either patients refusal (4), old age (2), lung problem (21), chest wail invasion (3) and heart problems (3). In 8 patients, there were more than 2 problems. The median age of the patients was 68 years (ranging from 60 to 86 years). Histologic cell type included souamous (24), adenocarcinoma (6) and unclassiried squamous cell (2). The clinical stages of the patients were 71 in 5, 72 in 25, 73 in 2 patients. Initial tumor size was 3.0 cm in 11, between 3.0 cm and 5.0 cm in 13 and more than 5.0 cm in 8 patients. Ail patients had taken chest x-rays, chest CT, abdomen USG and bone scan. Radiotherapy was delivered using 6 MV or 10 MV linear accelerators. The doses of primary tumor were the ranging from 54.0 Gy to 68.8 Gy (median; 61.2 Gy). The duration of treatment was from 37 days through 64 days (median; 0.5 days) and there was no treatment interruption except 1 patient due to poor general status. In 12 patients, concomitant boost technique was used. There were no neoadjuvant or adjuvant treatments such as surgery or chemotherapy. The period of follow-up was ranging from 2 months through 93 months (median; 23 months). Survival was measured from the date radiation therapy was initiated. Results : The overall survival rate was 44.6$\%$ at 2 years and 24.5$\%$ at 5 years, with the median survival time of 23 months. of the 25 deaths, 7 patients died of intercurrent illness, and cause-specific survival rate was 61.0$\%$ at 2 years and 33.5$\%$ at 5 years. The disease-free survival rate was 38.9$\%$ at 2 years and 28.3$\%$ at 5 years. The local-relapse-free survival rate was 35.1$\%$, 28.1$\%$, respectively. On univariate analysis, tumor size was significant variable of overall survival (p=0.0015, 95$\%$ C.1.; 1.4814-5.2815), disease-free survival (P=0.0022, 95$\%$ C.1., 1.4707-5.7780) and local-relapse-free survival (p=0.0015, 95$\%$ C.1., 1.2910- 4.1197). 7 stage was significant variable of overall survival (p=0.0395, 95$\%$ C.1.; 1.1084-55.9112) and had borderline significance on disease-free survival (p=0.0649, 95$\%$ C.1.; 0.8888-50.7123) and local-relapse-free survival (p=0.0582, 95$\%$ C,1.; 0.9342-52.7755). On multivariate analysis, tumor size had borderline significance on overall survival (p=0.6919, 955 C.1., 0.9610-5.1277) and local-relapse-free survival ( p=0.0585, 95$\%$ C.1.; 0.9720-4.9657). Tumor size was also significant variable of disease-free survival (p=0.0317, 95% C.1.; 1.1028-8.4968). Conclusion : Radical radiotherapy is an effective treatment for small (71 or f3 cm) tumors and can be offered as alternative to surgery in elderly or infirmed patients. But when the size of tumor is larger than 5 cm, there were few long-term survivors treated with radiotherapy alone. The use of hypefractionated radiotherapy, endobronchial boost, radisensitizer and conformal or IMRT should be consider to improve the local control rate and disease-specific survival rate.

  • PDF

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

National Survey of Sarcoidosis in Korea (유육종증 전국실태조사)

  • 대한결핵 및 호흡기학회 학술위원회
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.6
    • /
    • pp.453-473
    • /
    • 1992
  • Background: National survey was performed to estimate the incidence of sarcoidosis in Korea. The clinical data of confirmed cases were analysed for the practice of primary care physicians and pulmonary specialists. Methods: The period of study was from January 1991 to December 1992. Data were retrospectively collected by correspondence with physicians in departments of internal medicine, dermatology, ophthalmology and neurology of the hospitals having more than 100 beds using returning postcards. In confirmed and suspicious cases of sardoidosis, case record chart for clinical and laboratory findings were obtained in detail. Results: 1) Postcards were sent to 523 departments in 213 hospitals. Internal medicine composed 41%, dermatology 20%, ophthalmology 20% and neurology 19%. 2) Postcards were returned from 241 departments (replying rates was 48%). 3) There were 113 confirmed cases from 50 departments and 10 cases. The cases were composed from internal medicine (81%), dermatology (13%), ophthalmology (3%) and neurology (3%). 78 confirmed cases were analysed, which were composed from department of internal medicine (92%), dermatology (5%), and neurology (3%). 4) The time span for analysed cases was 1980 to 1992. one case was analysed in 1980 and the number gradually increased to 18 cases in 1991. 5) The majority of patients (84.4%) were in the age group of 20 to 49 years. 6) The ratio of male to female was 1 : 1.5. 7) The most common chief complains were respiratory symptoms, dermatologic symptoms, generalized discomforts, visual changes, arthralgia, abdominal pains, and swallowing difficulties in order. 16% of the patients were asymptomatic. 8) Mean duration between symptom onset and diagnosis was 2 months. 9) The most common symptoms were respiratory, general, dermatologic, ophthalmologic, neurologic and cardiac origin in order. 10) Hemoglobin, hematocrits and platelet were in normal range. 58% of the patients had lymphopenia measuring less than 30% of white cell count. The ratio of CD4 to CD8 lymphocytes was $1.73{\pm}1.16$ with range of 0.43 to 4.62. ESR was elevated in 43% of the cases. 11) Blood chemistry was normal in most cases. Serum angiotensin converting enzyme (S-ACE) was $66.8{\pm}58.6\;U/L$ with the range of 8.79 to 265 U /L. Proteinuria of more than 150 mg was found in 42. 9% of the patients. 12) Serum IgG was elevated in 43.5%, IgA in 45.5%, IgM in 59.1% and IgE in 46.7%. The levels of complement C3 and C4 were in the normal range. Anti-nuclear antibody was detected in 11% of the cases. Kweim test was performed in 3 cases, and in all cases the result was positive. 13) FVC was decreased in 17.3%, FEV1 in 11.5%, FEV1/FVC in 10%, TLC in 15.2%, and DLco in 64.7%. 14) PaO2 was decreased below 90 mmHg in 48.6% and PaCO2 was increased above 45 mmHg in 5.7%. 15) The percentage of macrophages in BAL fluid was $51.4{\pm}19.2%$, lymphocytes $44.4{\pm}21.1%$, and the ratio of CD4 to CD8 lymphocytes was $3.41{\pm}2.07$. 16) There was no difference in laboratory findings between male and female. 17) Hilar enlargement on chest PA was present in 87.9% (bilaterally in 78.8% and unilaterally in 9.1%). 18) According to Siltzbach's classification, stage 0 was 5%, stage 158.3%, stage 228.3%, and stage 38.3%. 19) Hilart enlargement on chest CT was present in 92.6% (bilaterally 76.4% and unilaterally in 16.2%). 20) HRCT was done in 16 cases. The most common findings were nodules, interlobular thickening, focal patchy infiltrations in order. Two cases was normal finding. 21) Other radiologic examinations showed bone change in one case and splenomegaly in two cases. 22) Gallium scan was done in 12 cases. Radioactivity was increased in hilar and mediastinal lymph nodes in 8 cases and in parenchyme in 2 cases. 23) The pathologic diagnosis was commonly performed by transbrochial lung biopsy (TBLB, 47.3%), skin and mediastinal lymph nodes biopsy (34.5%), peripheral lymph nodes biopsy (23.6%), open lung biopsy (18.2%) and bronchial biopsy in order. 24) The most common findings in pathology were non·caseating granuloma (100%), multi-nucleated giant cell (47.3%), hyalinized acellular scar (34.5%), reticulin fibrin network (20%), inclusion body (10.9%), necrosis (9.1%), and lymphangitic distribution of granuloma (1.8%) in order. Conclusion: Clinical, laboratory, radiologic and pathologic findings were summarized. This collected data will assist in finding a test for detection and staging of sarcoidosis in Korea in near future.

  • PDF