• Title/Summary/Keyword: bone response

Search Result 636, Processing Time 0.028 seconds

Effect of magnetic field on wave propagation in cylindrical poroelastic bone with cavity

  • Farhan, A.M.
    • Structural Engineering and Mechanics
    • /
    • v.61 no.4
    • /
    • pp.539-549
    • /
    • 2017
  • In this paper, the wave propagation in an infinite poroelastic cylindrical bone with cavity is studied. An exact closed form solution is presented by employing an analytical procedure. The frequency equation for poroelastic bone is obtained when the boundaries are stress free and is examined numerically. The magnitude of the frequency equation, wave velocity and attenuation coefficient are calculated for poroelastic bone for different values of magnetic field, density and frequency. In wet bone little frequency dispersion was observed, in contrast to the results of earlier studies. Such a model would in particular be useful in large-scale parametric studies of bone mechanical response. Comparison was made with the results obtained in the presence and absence of magnetic field. The results indicate that the effect of magnetic field, density and frequency on wave propagation in poroelastic bone are very pronounced.

HISTOLOGIC EvALUATION OF BONE HEALING AROUND TITANIUM PLASMA SPRAYED AND HYDROXYAPATITE-COATED IMPLANTS IN DOGS (성경 대퇴골에 매식된 Titanium Plasma Spray 및 Hydroxyapatite 피복임프란트 주위의 골치유 양상)

  • Huh, Ki-Nam;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.2
    • /
    • pp.418-437
    • /
    • 1995
  • The effect of the hydroxyapatite coatings on Titanium implants has been the subject of recent investigations. So far, the use of HA coating remains substantially controversial.This study was aimed to evaluate histologically the bone healing patterns around titanium plasm sprayed(TPS) amd HA-coated implant after implantation into the femur neck of ten adult dogs. After implantation, animals were sacrificed at the intervals of 2,4,6,8 and 12 weeks.The fluorescent dyes were injected on the postoperative 4th and 12th week into the animals supposed to be killed at the 12th week. The morphology and direction of new bone formation was similar in both TPS and HA-coated implants.There was a tendency toward more bone formation in the cortical bone area than in the cancellous bone area. Histologically,in the interface of the HA-coated implants, bone response and bone maturation was faster, compared to the TPS implants in the 2nd and 4th week. By fluorescent microscopy, new bone formation was active in the 4th week around both implants and was directed from the periosteum overlying cortical bone to the cancellous bone. These results suggest that the bone formation and maturation is faster during the early healing stage in the interface of the HA-coated implant and where the cortical bone quality is poor, HA coated implant is superior to the TPS implant in the early phase of new bone formation.

  • PDF

The influence of systemically administered oxytocin on the implant-bone interface area: an experimental study in the rabbit

  • Cho, Sung-Am;Park, Sang-Hun;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.505-511
    • /
    • 2014
  • PURPOSE. The purpose of this study was to assess the effect of systemically administered oxytocin (OT) on the implant-bone interface by using histomorphometric analysis and the removal torque test. MATERIALS AND METHODS. A total of 10 adult, New Zealand white, female rabbits were used in this experiment. We placed 2 implants (CSM; CSM Implant, Daegu, South Korea) in each distal femoral metaphysis on both the right and left sides; the implants on both sides were placed 10 mm apart. In each rabbit, 1 implant was prepared for histomorphometric analysis and the other 3 were prepared for the removal torque test (RT). The animals received intramuscular injections of either saline (control group; 0.15 M NaCl) or OT (experimental group; $200{\mu}g/rabbit$). The injections were initiated on Day 3 following the implant surgery and were continued for 4 subsequent weeks; the injections were administered twice per day (at a 12-h interval), for 2 days per week. RESULTS. While no statistically significant difference was observed between the two groups (P=.787), the control group had stronger removal torque values. The serum OT concentration (ELISA value) was higher in the OT-treated group, although no statistically significant difference was found. Further, the histomorphometric parameter (bone-to-implant contact [BIC], inter-thread bone, and peri-implant bone) values were higher in the experimental group, but the differences were not significant. CONCLUSION. We postulate that OT supplementation via intramuscular injection weakly contributes to the bone response at the implant-bone interface in rabbits. Therefore, higher concentrations or more frequent administration of OT may be required for a greater bone response to the implant. Further studies analyzing these aspects are needed.

High Glucose Inhibitory Effects on Bone Formation in UMR106 Cells

  • Kwon, Eun-Hee;Jung, In-Ok;Kim, Sung-Jin
    • Biomolecules & Therapeutics
    • /
    • v.11 no.2
    • /
    • pp.81-84
    • /
    • 2003
  • Recently, diabetes has been found to be associated with osteoporosis. Specially in IDDM. In both type I and type II diabetes, glucose levels are elevated. Thus, a linkage between high glucose and osteoporosis can not be ruled out. In this study, an attempt has been made to observe the effect of high glucose on bone formation; osteoblast like UMR 106 cells were treated with high glucose (22 mM, 33 mM) for 1, 3 or 7 days. The high concentration of glucose inhibited markers. of bone formation activity such as alkaline phosphatase and collagen synthesis. In addition, reduction in the level of total cellular protein in response to high glucose was also observed. This study showed high glucose concentration could alter the bone metabolism leading to a defective bone formation and thus paving the linkage of such situation to diabetic complications.

Bone Cell Response to Neurotransmitters and Mechanical Loading (신경전달물질 및 물리적 자극에 대한 뼈 세포의 반응)

  • Kwag, J.H.;Kim, B.G.;Kim, K.H.;Kim, C.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.89-93
    • /
    • 2009
  • Bone remodeling is a continuous process of skeletal renewal during which bone formation is tightly coupled to bone resorption. Mechanical loading is an important regulator of bone formation and resorption. In recent studies, neurotransmitters such as vasoactive intestinal peptide (VIP) were found to be present inside bone tissue and have been suggested to potentially regulate bone remodeling. In this study, our objective was to use a pre-established in vitro oscillatory fluid flow-induced shear stress mechanical loading system to quantify the effect of VIP on bone resorptive activity and investigate its combined effect with mechanical loading. VIP decreased osteoclastogenesis significantly decreased RANKL/OPG mRNA ration by approximately 90%. Combined VIP and mechanical loading further decreased RANKL/OPG ratio to approximately 95%. These results suggest that VIP present in bone tissue may synergistically act with mechanical loading to regulate bone remodeling via suppression of bone resorptive activities.

Induction of Radiation Adaptive Response in Lymphocytes of patients Undergoing Bone Scintigraphy (골 신티그라피를 시행한 환자의 림프구에서 방사선 적응반응의 유도에 관한 연구)

  • Min, Jung-Jun;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.172-177
    • /
    • 1999
  • Purpose: The purpose of this study was to ascertain whether radiation adaptive response could be induced by Tc-99m-methylene diphosphonate (Tc-99m-MDP) in peripheral lymphocytes of patients undergoing bone scintigraphy. Materials and Methods: Lymphocytes from 22 patients (6 males, 16 females, mean age $50{\pm}14$ years) were collected before and after bone scintigraphy using 740 MBq Tc-99m-MDP Lymphocytes from 10 controls (6 males, 4 females, mean age $43{\pm}7$ years) were also collected. They were exposed to challenge dose of 2 Gy gamma rays using a cell irradiator. Number of ring-form and dicentric chromosomes per 600 cells (chromosomal aberrations) was counted under the light microscope. Results: Chromosomal aberrations in patients before bone scintigraphy ($385.1{\pm}30.5$) was not different from that of controls ($367.8{\pm}36.6$). However, chromosomal aberrations in patients after bone scintigraphy was significantly decreased to $192.6{\pm}22.1$ (p=0.0001). Conclusion: Low dose gamma-irradiation by Tc-99m-MDP used for bone scintigraphy induces a cytogenetic adaptive response in peripheral lymphocytes.

  • PDF

The Role of Thallium-201 Scintigraphy in Bone and Soft Tissue Tumor (근골격계 종양에서 탈륨 스캔의 역할)

  • Shin, Duk-Seop
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.2
    • /
    • pp.117-128
    • /
    • 2003
  • Thallium-201 scintigraphy is used to discriminate the malignant bone tumor from the benign by qualitatively and quantitatively, and to predict the response of preoperative chemotherapy in osteosarcoma, by comparing the changes of thallium uptake ratio after chemotherapy to the tumor necrosis ratio. Thallium-201 scintigraphy scan should be done prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator is usually used for scanning. The patient is injected with 2-3mCi of Tl-201 and the early phase is checked in 30 minutes and delayed phase in 3 hours. The scan images are visually evaluated by a blinded nuclear medicine physician. We could evaluate true positive, true negative, false positive and false negative by the comparison of results with those of biopsy, and calculate positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%). For the quantitative analysis of thallium uptake, we drew the region of interest on the tumor side and contralateral normal side as mirror image, and calculated the uptake ratio with dividing the amount of gamma count in tumor side by normal side. We could calculate the percent changes of thallium uptake ratio in early and delayed phase, and compare them to the ratio of tumor necrosis. Thallium-201 scintigraphy proved as useful imaging study to discriminate malignant bone tumor from benign, but had exception in giant cell tumor and low grade malignant bone tumors. We can use T1-201 scan to differentiate the benign from the malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

Characteristics and response of mouse bone marrow derived novel low adherent mesenchymal stem cells acquired by quantification of extracellular matrix

  • Zheng, Ri-Cheng;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.351-360
    • /
    • 2014
  • PURPOSE. The aim of present study was to identify characteristic and response of mouse bone marrow (BM) derived low-adherent bone marrow mesenchymal stem cells (BMMSCs) obtained by quantification of extracellular matrix (ECM). MATERIALS AND METHODS. Non-adherent cells acquired by ECM coated dishes were termed low-adherent BMMSCs and these cells were analyzed by in vitro and in vivo methods, including colony forming unit fibroblast (CFU-f), bromodeoxyuridine (BrdU), multi-potential differentiation, flow cytometry and transplantation into nude mouse to measure the bone formation ability of these low-adherent BMMSCs. Titanium (Ti) discs with machined and anodized surfaces were prepared. Adherent and low-adherent BMMSCs were cultured on the Ti discs for testing their proliferation. RESULTS. The amount of CFU-f cells was significantly higher when non-adherent cells were cultured on ECM coated dishes, which was made by 7 days culturing of adherent BMMSCs. Low-adherent BMMSCs had proliferation and differentiation potential as adherent BMMSCs in vitro. The mean amount bone formation of adherent and low-adherent BMMSCs was also investigated in vivo. There was higher cell proliferation appearance in adherent and low-adherent BMMSCs seeded on anodized Ti discs than machined Ti discs by time. CONCLUSION. Low-adherent BMMSCs acquired by ECM from non-adherent cell populations maintained potential characteristic similar to those of the adherent BMMSCs and therefore could be used effectively as adherent BMMSCs in clinic.

Implant-Supported Fixed Prostheses for the rehabilitation of distal free end in periodontally compromised dentitions Number of fixtures affecting bone tissue change (치주질환에 이환된 환자에서 구치 상실 치열 수복을 위한 임플란트 수복)

  • Yi, Seung-Won;Kim, Young-Soo
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.53-63
    • /
    • 2005
  • Number of fixtures supporting prosthesis for rehabilitation of partial edentulism in distal area is an important factor in distal area to the bone tissue response around dental implant. Optimal number and optimal positioning of dental implant has leaded to the stable condition of bone tissue and successful long-term treatment outcome. This clinical and radiographic study was performed to document and evaluate the short-term result of occlusal rehabilitation by means of implant-supported fixed prostheses (ISPs) especially for partial edentulism in distal area in patients treated for advanced periodontal disease and to verify the number of fixture affecting the bone tissue response. A total of 30 consecutive patients referred because of advanced periodontal disease were included. Before the implant therapy was initiated, periodontal treatment was performed and the outcome evaluated during at least a 6-month period. An individual maintenance care program was designed for each patient. All 75 implants were placed using a 2-stage surgical approach. The patients were divided into 2 groups, in one of which two fixtures were placed and in the other of which three fixtures were placed with tripodal geometry. Following installation of the ISPs, all patients underwent a baseline examination including evaluation of i) oral hygiene, and ii) periodontal/ peri-implant conditions, and iii) radiographs. These examinations were repeated annually during the 1 or 2-year observation period. The results were as follows: 1.No single implant was lost during the observation follow-up period. 1.The percentage of plaque harboring surfaces and bleeding units upon probing were found to be low (<10%), and no soft tissue complications were recorded. 1.Two-fixture group showed bone destruction ranged from 0.0mm to 1.5mm and the mean was 0.31mm. Three-fixture group showed more bone destruction of 0.51mm. There was no statistically difference between two groups. These results suggested that the factor for success is not the number of fixture but the strict maintenance of peri-implant tissue health and initial stability of fixture.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS: HISTOMORPHOMETRIC AND RESONANCE FREQUENCY ANALYSIS IN DOGS

  • Song Woo-Seok;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.671-678
    • /
    • 2004
  • Statement of problem. Reducing treatment time in implant dentistry is a matter of main concern. There are so many factors affecting the success rate of immediate or early loaded implant for the initial bone response. The especially microscopic properties of implant surfaces playa major role in the osseous healing of dental implant. Purpose. The aims of this study were to perform a histologic and histomorphometric comparison of the healing characteristics anodically roughened surface, HA coated surface and RBM surface implant, and to compare of ISQ values measured by $Osstell^{TM}$ for resonance frequency analysis in dogs mandible during 2 weeks. Material and method. Bone blocks from 2 dogs were caught after covered healing for 0 day(2 h); Group I, 1 week; Group II and 2 weeks; Group III. One longitudinal section was obtained for each implant and stained with hematoxylin and eosin. Histomorphometric analysis was done with Kappa Imagebase system to calculate bone-to-implant contact and bone volumes inside the threads. ISQ values were measured in every time of surgery schedule. Conclusion. The experiment revealed that: 1. The percentages of bone-to-implant contact on the fixture in each group were not significantly different(P > 0.05). 2. The percentages of bone area inside the threads on the fixture in each group were not significantly different(P > 0.05). 3. The ISQ level showed clinical stability of each fixture during 2 weeks(all ISQ level ${\geq}71$ ).