• Title/Summary/Keyword: bone quality

Search Result 704, Processing Time 0.022 seconds

The influence of implant diameter, length and design changes on implant stability quotient (ISQ) value in artificial bone (임플란트의 직경, 길이 및 디자인변화가 임플란트 안정성지수(ISQ)에 미치는 영향)

  • Lee, Jeong-Yol;Lee, Won-Chang;Kim, Min-Soo;Kim, Jong-Eun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.292-298
    • /
    • 2012
  • Purpose: The purpose of this study is to ascertain the stability of the implant by comparing the effects of the change of implant diameter, length and design on implant stability quotient. Materials and methods: To remove the variable due to the difference of bone quality, the uniform density (0.48 g/$cm^3$) Polyuretane foam blocks (Sawbones$^{(R)}$, Pacific Research Laboratories Inc, Vashon, Washington) were used. Implants (Implantium$^{(R)}$, Dentium, Seoul, Korea) were placed with varying diameters (${\phi}3.8$, ${\phi}4.3$ and ${\phi}4.8$) and length (8 mm, 10 mm and 12 mm), to assess the effect on implant stability index (ISQ). Also the influence of the design of the submerged and the non-submerged (SimplelineII$^{(R)}$, Dentium, Seoul, Korea) on ISQ was evaluated. To exclude the influence of insertion torque, a total of 60 implants (n = 10) were placed with same torque to 35 N. Using Osstell$^{TM}$ mentor (Integration Diagnostic AB, Sweden) ISQ values were recorded after measuring the resonant frequency, one-way ANOVA and Tukey HSD test results were analyzed. (${\alpha}$=0.05). Results: 1. The change of the diameter of the implant did not affect the ISQ (P>.05), but the increase of implant length increased the ISQ(P<.001). 2. The change in implant design were correlated with the ISQ, and the ISQ of submerged design was significantly higher than that of the non-submerged design(P<.05). Conclusion: In order to increase implant stability, the longer implant is better to be selected, and on the same length of implant, submerged design is thought to be able to get a higher ISQ than the non-submerged.

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

A Study for the Quality Control of Food Served by Contracted Management in High School Foodservice Centre (위탁급식을 실시하고 있는 고등학교 급식음식의 품질관리에 관한 연구)

  • 김혜영;김희정
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.4
    • /
    • pp.304-314
    • /
    • 2000
  • Following the recent policy, enlargement of foodservice and contracted management systems of high school foodservices have been accelerated, and the scales of foodservices have been gradually increased. A sudden growth of domestic foodservice companies have remarkably disparated. Yet compared to that of the foodseuice control in advanced countries, domestic foodservice control has a lot more to learn. Due to the characteristics of foodservice establishment serving many people at a time, there is always a high potential of food bone outbreak. The purpose of this study was to evluate hazard factors in the steps of production, holding and assembly and service of fried curry hair-tail, cold seaweed and cucumber, fried pork cutlet, that were served by contracted management in high school foodservice centre, then to suggest method of control with the Hazard Analysis Critical Control Point(HACCP) program. Also we suggested the possibility that the contracted management of foodservice system can be established and utilized to identify the variation of holding temperature among floods up to 6 hours after cooking. The results are as follows; The hazard factors in food product had come from the temperature, time, pH, Aw, equipment and utensils. The critical control point(CCP) of each food product; curry hair-tail, cold seaweed and cucumber and pork cutlet was cooked and held before serving, prepared and held before serving, cooked and held before serving, and prepared, cooked and held before serving, respectively.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MANDIBULAR CANTILEVERED PROSTHESIS SUPPORTED BY IMPLANTS (임프란트로 지지된 하악 켄티레버 보철물의 3차원 유한요소 분석)

  • Cho, Chul;Shin, Sang-Wan;Kwon, Jong-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.724-743
    • /
    • 2000
  • One of the biggest clinical problems of osseointegrated implant prosthesis is the excessive stress caused by bite forces which are transfered directly into the bone through the osseointegrated implant fixtures. So several biodynamic problems occur when there is an excessive fatigue stress. The factors of stress distribution are the number, kind, position, arrangement of the implants, and the distance between the implants, and the kind, quality of superstructure prosthesis and connection type between the rest implant and the superstructure. Recently, a distal short additional implant, socalled rest implant, is employed to reduced the stresses in conventional cantilevered prostheses. This study was undertaken to analyze the stresses transfered by osseointegrated implant cantilevered prostheses depending upon the number and the position of implants, the presence of rest implant, and the type of their connection. Three dimensional finite element analysis was attempted using ANSIS ver. 5.3 program under IBM INDIGO computer. The results were as follows : 1. The rest implant influenced on the pattern of stress distribution on the anterior area of the mandible and the superstructure. 2. In the group employing the rest implants, the fixed type of connection between the rest implant and the superstructure was more stable than the ball attachment type on the stress distribution. 3. In the group employing the ball attachment between the rest implant and the superstructure, the case with 4-implants(on canine, premolar) was little more stable than the case with 6-implants and the case with 4-implants(on incisor, premolar) on the stress distribution. 4. In the cantilevered group, the case with 4-implants(on incisor, premolar) and the case with 6-implants were more stable than the case with 4-implants(on canine, premolar) on the stress distribution. 5. In all of the group, the case with 6-implants and the fixed type of connection was the most stable and the case with 4-implants (on canine, premolar) was the most unstable on the stress distribution.

  • PDF

A Monte Carlo Simulation for the Newly Developed Head-and-Neck IMRT Phantom: a Pilot Study (제작된 선량 검증용 IMRT 팬텀의 몬테칼로 시뮬레이션: 예비적 연구)

  • Kang, Sei-Kwon;Cheong, Kwang-Ho;Ju, Ra-Hyeong;Cho, Byung-Chul;Oh, Do-Hoon;Kim, Su-SSan;Kim, Kyoung-Ju;Bae, Hoon-Sik;Han, Young-Yih;Shin, Eun-Hyuk;Park, Sung-Ho;Lim, Chun-Il
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.126-133
    • /
    • 2007
  • A head-and-neck phantom was designed in order to evaluate remotely the quality of the delivery dose of intensity modulated radiation therapy (IMRT) in each institution. The phantom is homogeneous or inhomogeneous by interchanging the phantom material with the substructure like an air or bone plug. Monte Carlo simulations were executed for one beam and three beams to the phantom and compared with ion chamber and thermoluminescent dosimeter (TLD) measurements of which readings were from two independent institutions. For single beam, the ion chamber results and the MC simulations agreed to within about 2% TLDs agreed with the MC results to within 2% or 7% according to which institution read the TLDs. For three beams, the ion chamber results showed -5% maximum discrepancy and those of TLDs were $+2{\sim}+3%$. The accuracy of the TLD leadings should be increased for the remote dose monitoring. MC simulations are a valuable tool to acquire the reliability of the measurements in developing a new phantom.

  • PDF

A study on Hand Injury in Industrial Complex Workers (공단 근로자의 수부 손상에 관한 연구)

  • Kim, Soo-Min;Gu, Kyung-Sook;Lee, Geun-Hee;Kang, Ho-Hyun;Hyung, In-Han;Sung, Kwang-Jun
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.1
    • /
    • pp.905-913
    • /
    • 1999
  • The hand is a part of the body which has various functions and a sophisticated structures bone, Joint, tendon, ligament and logical nerve organ are aggregated densely in the hand of anatomy its functions are delicate. The hand's functions are very important for doing ADL and a worker's As the hand is structure which is used often and commonly it is a site that can be easily damaged by a accident on work. This study was investigated and analyzed by the results from 238 workers who had hand injury and physical therapy from January, 1997 to June, 1998 at Shin-Pung, Jang-Lim industrial complex which is located in Pusan. 1. A hand injury most frequertly happened in worker in their 30's and 20's(66 case, 28%), second was 57 case(24%) their 40's. 2. Among workers suffering from injury, who had one or less than 2 years on the job, a injury most frequently occurred. 3. Scale of workers, A injury most frequently happend in a place where had workers from 10 to 50. 99 workers from that place were 42% of total. 4. Month of occurrence rate in March were the highest compared to other months 40 injury workers in march were 17% of the total. Second was July, and the least was April that injury appeared with 10 workers. (4.2% of the total) 1. Frocture was the most common lesion 82 workers had that lesion(34%) soft tissue rupture was 71 workers who were 30% of total in type of lesion. 2. Of the site of lesion multiple case was the most common in which 57 workers had that lesion it were 24% of the total. The next was the index finger site in which 44 workers were 19% of the total. The index finger was the most common mono-site that can be lesion 36 workers were the middle finger lesion workers who were 15% of the total. Of the joint lesion, PIP was the most in which 76 workers were 44% and in MC 27 workers were 15% of the total. 3. Interval of physical therapy 79 workers from one month to 2 months, was 33% of the total and 174 workers who had therapy below 3 months were 71% 4. Post injury of disablity of the site, phalangeous disability was the most in which 148 workers had that injury and they were 62% of the total of the grade of disability 110 workers who were 46% of the total state from less than 25% disability in hand-function and 59 patients who were 25% had no disability. There were 6 workers (3% of the total) who had over -75%-dibability in the hand-function.

  • PDF

A Multi-center Clinical Study of Posterior Lumbar Interbody Fusion with the Expandable Stand-alone Cage($Tyche^{(R)}$ Cage) for Degenerative Lumbar Spinal Disorders

  • Kim, Jin-Wook;Park, Hyung-Chun;Yoon, Seung-Hwan;Oh, Seong-Hoon;Roh, Sung-Woo;Rim, Dae-Cheol;Kim, Tae-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.251-257
    • /
    • 2007
  • Objective : This multi-center clinical study was designed to determine the long-term results of patients who received a one-level posterior lumbar interbody fusion with expandable cage ($Tyche^{(R)}$ cage) for degenerative spinal diseases during the same period in each hospital. Methods : Fifty-seven patients with low back pain who had a one-level posterior lumbar interbody fusion using a newly designed expandable cage were enrolled in this study at five centers from June 2003 to December 2004 and followed up for 24 months. Pain improvement was checked with a Visual Analogue Scale (VAS) and their disability was evaluated with the Oswestry Disability Index. Radiographs were obtained before and after surgery. At the final follow-up, dynamic stability, quality of bone fusion, interveretebral disc height, and lumbar lordosis were assessed. In some cases, a lumbar computed tomography scan was also obtained. Results : The mean VAS score of back pain was improved from 6.44 points preoperatively to 0.44 at the final visit and the score of sciatica was reduced from 4.84 to 0.26. Also, the Oswestry Disability Index was improved from 32.62 points preoperatively to 18.25 at the final visit. The fusion rate was 92.5%. Intervertebral disc height, recorded as $9.94{\pm}2.69\;mm$ before surgery was increased to $12.23{\pm}3.31\;mm$ at postoperative 1 month and was stabilized at $11.43{\pm}2.23\;mm$ on final visit. The segmental angle of lordosis was changed significantly from $3.54{\pm}3.70^{\circ}$ before surgery to $6.37{\pm}3.97^{\circ}$ by 24 months postoperative, and total lumbar lordosis was $20.37{\pm}11.30^{\circ}$ preoperatively and $24.71{\pm}11.70^{\circ}$ at 24 months postoperative. Conclusion : There have been no special complications regarding the expandable cage during the follow-up period and the results of this study demonstrates a high fusion rate and clinical success.

Oncologic Outcome of Sacral Chordoma (천골에 발생한 척색종의 치료결과)

  • Cho, Sang-Hyun;Lee, Soo Yong;Jeon, Dae-Geun;Song, Won-Seok;Kong, Chang-Bae;Lee, Jung-Dong;Cho, Wan-Hyeong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.18 no.2
    • /
    • pp.66-71
    • /
    • 2012
  • Purpose: We analyzed treatment result to examine the outcome for patients with sacral chordoma and to determine relevant prognostic factors. Materials and Methods: We retrospectively reviewed 19 patients with sacral chordoma seen at out institution between 1990 and 2010. There were 9 men and 10 women with mean age of 56 years. The average follow up was 63 months (range, 25-144 months). 15 patient received surgical treatment, six of these patient had wide, eight had marginal, one had intralesional margin and 4 patient treated with Radiation therapy only. Results: The disease free and overall survival rate for all 19 patients was 34.7% and 79.7% at 5-years, respectively. Statistical analysis using the log-rank test revealed no significant difference between the surgery and radiation therapy groups in overall survival (p=0.54). Nine of 19 patients had local recurrence at a median of 2.5 years postoperatively. Seven of these 9 patients had distant metastasis at a median of 4.5 years postoperatively. Among the variables, tumor size (p=0.033) and tumor involvement of above S3 (p=0.032) were independent prognostic factor for overall survival. Nine of 15 patients who received surgical treatment had postoperative complication such as voiding difficulty and incontinence. Conclusion: Careful consideration of the patient general condition and predictable complication of the treatment might be the best way to improve patient's survival and quality of life.

3-Year Survival Analysis of RBM and Acid-Etched Surface Implants (RBM 표면 임플란트와 산부식 표면 임플란트의 3년 생존율에 대한 비교 연구)

  • Yoon, Dae-Woong;Kim, Moon-Seob;Jang, Han-Seung;Jin, Soo-Young;Mah, Deuk-Hyun;Jeong, Gyeong-Dal;Park, Hyun-Chun;Kim, Hee-Jung;Kim, Hak-Kyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.393-403
    • /
    • 2011
  • The purpose of this study was to analyze and compare survival rates of resorbable blast media(RBM) surface and acid-etched surface implants being usually used in clinics. RBM surface implants (USII, Osstem, Busan, Korea) or acid-etched surface implants ($Osseotite^{(R)}$, Biomet $3i^{[TM]}$, FL, USA) were placed in edentulous area of 140 patients between January of 2005 and March of 2007. The number of implants was 304, and 152 out of them were RBM surface implants while another 152 were acid-etched surface implants. According to the evaluation items, the survey was performed before and after the implants installations. The 3-year survival rates of both kind of implants were calculated. 1. Total of 152 RBM surface implants were placed. Among them, one implant was failed, which was implanted in the posterior mandible with D2 bone quality. The failure was resulted from fracture of the fixture. Others showed good results and survival rate of RBM surface implant was 99.34%. 2. Total of 152 acid-etched surface implants were placed. Seven implants of them were failed, thus, survival rate was 95.39%. The causes of the failures were considered as infection, overheat and the lack of initial stability. In this research, both implants showed good 3-year survival rate, although RMB surface implant represented a better result.

Evaluation of 358 Mandibular Poster ior Implants: A 3-year Retrospective Study (하악 구치부위에 식립한 358개 임플란트의 생존율에 대한 3년간 후향적 연구)

  • Yoon, I-Kwon;Lee, Gi;Lee, Dong-Un;Choi, Ju-Young;Yu, Jeong-A;Park, Pil-Gyu;Kim, Jeong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.59-68
    • /
    • 2010
  • Recently, dental implants extensively inserted on edentulous area show highly clinical success rate. However, clinicians cannot exclude the possibility of failure and it often unexpectively occures. Many possible factors associated with failure of dental implants have been reported but controversy exists over the extent to them. In this study, we collected 212 patients who had been inserted 358 dental implants on mandibular premolar and molar area from 2005 to 2006. The survival rate of fixtures was recorded according to age of patients, implantation site, implant system, diameter and length of fixtures. Multi-variable analysis using SPSS chi-square test was operated to verify relation of each factors and survival rates. Accumulative survival rate was 98.3% for 3 years. Only diameter of fixtures was related to the implant survival rate. This may be thought that wider fixtures had been chosen to rescue implants or used in sites of poor bone quality. Further continuous study will be needed for direct guidance associated with survival rate of implants.