• 제목/요약/키워드: bone plate

검색결과 553건 처리시간 0.034초

딥러닝 알고리즘을 이용한 3D프린팅 골절합용 판의 표면 결함 탐지 모델에 관한 연구 (A Study on Surface Defect Detection Model of 3D Printing Bone Plate Using Deep Learning Algorithm)

  • 이송연;허용정
    • 반도체디스플레이기술학회지
    • /
    • 제21권2호
    • /
    • pp.68-73
    • /
    • 2022
  • In this study, we produced the surface defect detection model to automatically detect defect bone plates using a deep learning algorithm. Bone plates with a width and a length of 50 mm are most used for fracture treatment. Normal bone plates and defective bone plates were printed on the 3d printer. Normal bone plates and defective bone plates were photographed with 1,080 pixels using the webcam. The total quantity of collected images was 500. 300 images were used to learn the defect detection model. 200 images were used to test the defect detection model. The mAP(Mean Average Precision) method was used to evaluate the performance of the surface defect detection model. As the result of confirming the performance of the surface defect detection model, the detection accuracy was 96.3 %.

Application of Plate and Circumferential Wiring with Resin to Bilateral Mandibular Fractures in a Calf: Case Report

  • Yu, Yong;Kim, Namsoo;Heo, Suyoung
    • 한국임상수의학회지
    • /
    • 제37권6호
    • /
    • pp.363-366
    • /
    • 2020
  • A 2-month-old, 50 kg male Korean native calf was referred with bilateral mandibular fractures. The bilateral mandible was hanging loose, with inability to use the jaw, indicated by excessive salivation. Radiography revealed a long oblique fracture in the right mandible, and a short oblique fracture in the left mandible. Computerized Tomography, a different form of radiography, revealed the fracture in the left mandible to be a comminuted fracture. In order to stabilize the bilateral mandible fractures, a combination of bone plate and wiring was applied; in addition, resin was applied to enhance stabilization of the mandible. Six weeks after surgery, the calf was able to masticate and ruminate well. In this case, application of the plate and wiring with resin to bilateral mandibular fractures presented a successful functional recovery. Accordingly, the combination of bone plate and wiring with resin can be an effective technique for treating mandibular fractures.

상완골 간부 불유합에 대한 금속판 고정 및 자가골 이식술 (Compression Plate Fixation with Autogenous Bone Graft for Humerus Shaft Nonunion)

  • 조철현;송광순;배기철;김인규;권두현
    • Clinics in Shoulder and Elbow
    • /
    • 제12권1호
    • /
    • pp.33-37
    • /
    • 2009
  • 목적: 상완골 간부 골절의 불유합에 대해 그 원인을 분석하고, 금속판 고정 및 자가골 이식술을 통한 수술적 치료의 결과를 평가하고자 하였다. 대상 및 방법: 총 18예를 대상으로 하였으며, 평균 추시 기간은 28개월이었다. 불유합에 대해 금속판 고정 및 자가골 이식술을 시행하였고, 골결손이 심한 경우 골단축술을 병행하였다. 술후 추시 단순 방사선 검사로 골유합을 확인하였고, ASES 점수 평가법을 이용하여 임상적 평가를 시행하였다. 결과: 불유합의 원인은 처음 수술시 금속판을 시행한 12예의 경우에서는 불충분한 금속판 길이가 6예, 금속판의 파손 2예, 나사못의 이완이나 파손이 2예, 감염이 1예, 정신과적 문제로 인한 환자의 불응성이 1예였고, 금속정 고정술을 시행한 3예에서는 전 예에서 골절 부위의 신연이 원인이었으며, 외고정을 시행한 3예에서는 불충분한 고정이 원인이었다. 전 예에서 골유합을 얻을 수 있었으며, 골유합까지의 기간은 평균 24주였다. 임상적 결과는 우수가 11예, 양호가 6예, 보통이 1예였다. 결론: 불유합에 대한 수술 시 불유합 부위에 존재하는 섬유조직이나 괴사된 골조직을 철저하게 제거한 후, 충분한 길이의 금속판 내고정술 및 자가골 이식술을 이용하면 만족스러운 결과를 얻을 수 있을 것으로 사료된다.

실험적 골조직 병소부에 관한 방사선학적 연구 (A RADIOGRAPHIC STUDY ON EXPERIMENTAL BONY LESIONS)

  • 이은기;김재덕
    • 치과방사선
    • /
    • 제17권1호
    • /
    • pp.233-248
    • /
    • 1987
  • The author studied the effect of periapical bone loss on radiographic interpretation by using a dry adult human mandible. Artificial bony lesions were created at the apices of two mandibular second molars and four mandibular bicuspids. The jaw was stabilized and various artificial lesions were radiographed under ideal circumstances. Radiographic pictures were recorded and compared with the size of the actual lesions. The obtained results were as follows: 1. The size of actual lesions were always larger than their radiographic pictures. 2. The size of actual lesion had a greater discrepancy in the molar area where the cortical plates were havier, but the lesions in the bicuspid areas were only slightely larger than their radiographic pictures, and in these areas the cortical plates were quite thin. 3 Periapical lesions located in cancellous bone did not appear on a radiograph, regardless of the size of the created lesion, but when the junctional bone was involved or the cortical plate was perforated, the definite bone destructive change was observed on the roentenogram. 4. Removal of the entire buccal or lingual plate did not affect the trabecular pattern of bone on the roentgenogram. 5. When the cancellous bone and junctional bone were removed simultaneously, altered trabecular patterns were observed on the roentgenogram.

  • PDF

응력해석에 의한 골절판이 부착된 인체 대퇴골의 골재형성 예측에 관한 연구 (A Study on the Prediction of Bone Remodeling of Plated-Human Femur using Stress Analysis)

  • Kim, Hyun-Su
    • 한국의학물리학회지:의학물리
    • /
    • 제6권2호
    • /
    • pp.111-125
    • /
    • 1995
  • 뼈는 주변 여건에 따라 뼈의 재질 및 형상이 변하는 일종의 동적 구조물로서, 보철물이 부착되면 뼈의 응력상태가 다라져 새로이 골재형성을 하게 된다. 특히, 골절판 부착시 뼈의 접촉은 촉진되나, 그 부위의 응력 변화에 의하여 골절판과 부착된 부분의 뼈는 오히려 약화되는 골다공증 현상을 야기하기도 한다. 본 연구에서는 뼈의 응력변화와 골재형성의 관계를 3차원 유한 요소법을 이용하여 관련시키고자 한다. 이는, 새로이 설계된 골절판 또는 어떤 보철물이, 비록 그 자체의 생체 적합성 및 충분한 강도를 갖게 되더라도 골재형성에 미치는 영향을 판단할 근거가 요구된다고 사료되기 때문이다. 그래서, 현 사용되는 골절판을 인체 대퇴골에 부착된 3차원 유한 요소 모델을 제작하여, 응력 차이법에 의한 골재형성의 경향을 조사하고, 그 경향을 기존 동물 실험결과와 비교 검토하여, 본 연구의 타당성을 평가하여 보철설계의 역학적 기초를 확립하고자 한다.

  • PDF

Effects of Bojungikgitang-gagambang on Longitudinal Bone Growth in Adolescent Rats

  • Lee, Min-Su;Kim, Ji-Young;Kim, Mi-Yeon;Chang, Gyu-Tae;Kim, Ho-Cheol
    • 대한한의학회지
    • /
    • 제33권2호
    • /
    • pp.1-10
    • /
    • 2012
  • Objectives: This study was aimed to investigate the effect of Bojungikgitang-gagambang (BJIG) on longitudinal bone growth in rats. Methods: The BJIG treated group (300 mg/kg) and the control group (vehicle) were administered orally twice daily for 4 days. To investigate the effects of BJIG we measured body weight gain. The bone growth effect was analyzed by measuring between fluorescent lines marked with tetracycline, which plays the role of fluorescent dye on the surface of the tibia. Tetracycline was intraperitoneally injected. The height of growth plates in the epiphyseal plate was measured. The expression of bone morphogenetic protein-2 (BMP-2) and insuline-like growth factor-1 (IGF-1) was investigated by immunohistochemistry. Results: BJIG caused a significant acceleration of longitudinal bone growth of $349.7{\pm}15.9{\mu}m/day$ compared to control ($319.8{\pm}21.4{\mu}m/day$). The height of overall growth plate was not significantly more compared to the control, but the size of cells in the proliferative zone and hypertrophic zone were. In the immunohistochemistry, BMP-2 and IGF-1 were expressed markedly in the proliferative or hypertrophic zone, respectively. Conclusions: BJIG stimulated the chondrocyte hypertrophy and chondrogenesis in the growth plate and directly increased the longitudinal tibia length of rats.

치과용 Ti-6Al-4V 합금 골 고정판 표면에 형성된 나노튜브의 부식거동 (Corrosion Behavior of Nanotube Formed on the Bone Plate of Ti-6Al-4V Alloy for Dental Use)

  • 김원기;이충환;정재헌;최한철
    • 한국표면공학회지
    • /
    • 제43권1호
    • /
    • pp.25-30
    • /
    • 2010
  • Titanium and titanium alloys are widely used for orthopedic and dental implants for their superior mechanical properties, low modulus, excellent corrosion resistance and good biocompatibility. In this study, corrosion behaviors of nanotube formed on the bone plate of Ti-6Al-4V alloy for dental use have been investigated. $TiO_2$ nanotubes were formed on the dental bone plates by anodization in $H_3PO_4$ containing 0.6 wt % NaF solution at $25^{\circ}C$. Electrochemical experiments were performed using a conventional three-electrode configuration with a platinum counter electrode and a saturated calomel reference electrode. Anodization was carried out using a scanning potentiostat (EG&G Co, Model 263A USA), and all experiments were conducted at room temperature. The surface morphology was observed using field emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The corrosion behavior of the dental bone plates was examined using potentiodynamic test(potential range of -1500~2000 mV) in a 0.9% NaCl solution by potentiostat (EG&G Co, PARSTAT 2273. USA). The inner diameter of nanotube was about 150~180 nm with wall thickness of about 20 nm. The interspace of nanotube to nanotube was 50 nm. The passive region of the nanotube formed bone plates showed the broad range compared to non-nanotube formed bone plates. The corrosion surface of sample was covered with corrosion products.

Open Reduction of Proximal Interphalangeal Fracture-Dislocation through a Midlateral Incision Using Absorbable Suture Materials

  • Lee, Jae Jun;Park, Hyoung Joon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il
    • Archives of Plastic Surgery
    • /
    • 제40권4호
    • /
    • pp.397-402
    • /
    • 2013
  • Background Fracture-dislocation of the proximal interphalangeal (PIP) joint is a relatively common injury. Various treatments for fracture-dislocation of the PIP joint have been reported. In the present study, we performed open reduction through a midlateral incision using absorbable sutures to reduce the small bone fragments and performed volar plate repair. Methods We treated nine patients with fracture-dislocation of the PIP joint with small fractured bone fragments too small for pinning or screw fixation. Patients with volar plate injury were treated with open reduction and volar plate repair at the periosteum of the middle phalangeal bone base by the modified Kessler method using absorbable sutures. All patients were placed in a dorsal aluminum extension block splint, which maintained the PIP joint in approximately 30 degrees of flexion to avoid excessive tension on the sutured volar plate. Results At a mean final follow-up of postoperative 9 months, all patients were evaluated radiographically and had adequate alignment of the PIP joint and reduction of the displaced bone fragments. Range of motion was improved and there were no complications. Conclusions This technique is an excellent alternative to the current method of treating patients with fracture-dislocations that include small fragments that are too small for pinning or screw fixation. It is a less invasive surgical method and enables stable reduction and early exercise without noticeable complications.

Unicortical Bone Necrosis of the Fibula Free Flap Associated to the Fixation with a Nonlocking 2.0-mm Reconstruction Plate and Screws

  • Pereira, Gustavo N.;Ribeiro, Diogo;Saraiva, Luis;Freitas, Hugo;Santos, Ana R.
    • Archives of Plastic Surgery
    • /
    • 제49권3호
    • /
    • pp.413-417
    • /
    • 2022
  • The authors present a unique case of osteonecrosis of a cortical half of a fibula free flap that has not been reported in the literature yet. This complication was associated with the impairment of the vascularization of periosteum in the cortical half of fibula that was fixated with a nonlocking reconstructive 2.0-mm plate and screws but other factors could have been involved. The patient was submitted to excision of a cemento-ossifying fibroma that resulted in a left hemimaxilectomy mesoinfrastructure defect classified as the Cordeiro type 2B. The 42-year-old female patient was submitted to reconstruction with an osteomusculocutaneous fibula free flap plus a segment of fibula graft. The two bone segments of the free flap used to reconstruct the anterior and left alveolar crest were fixated with a reconstructive 2.0-mm plate of matrixMANDIBLE system. The only reported complication was an oronasal fistula that healed with conservative treatment and the referred osteonecrosis of the external cortical half of the fibula free flap with plate exposure at 2.5 years postoperatively. Surgical excision of the osteonecrosed cortical half of the fibula with the plate and screws was performed, while the other cortical underwent bone union as corroborated by computed tomography scans.

티타늄 배양에 대한 배양골수와 치은 섬유아세포의 생체적합성 (The Biocompatibility Of Cultured Bone Marrow Cells And Gingival Fibroblasts On The Titanium Surfaces)

  • 오충영;박준봉;권영혁;이만섭
    • Journal of Periodontal and Implant Science
    • /
    • 제26권1호
    • /
    • pp.143-160
    • /
    • 1996
  • The purpose of this study was to evaluate the response in aspect of attachment and growth rate of osteoblasts and growth rate of osteoblasts and human gingival fibroblasts to the commercially pure titanium(CP titanium)and titanium alloy(Ti-6AI-4V) that are used widely as implant materials, and to obtain the basic information to ideal implant materials. In the studly, commercially pure titanium in first test group, titanium alloy(Ti-6AI-4V) in second test group, cobalt-chrome-molybdenum alloy(Co-Cr-Mo alloy) in positive control group, and tissue culture polystyrene plate in negative control group were used. The results of this study were as follows. 1. Bone marrow cells cultured on CP titanium and Ti-6Al-4V showed significantly greater attachment and growth rate(p(0.05) compared to Co-Cr-Mo alloy in each time. 2. There were no significant differences(p>0.05) in attachment and growth rate of bone marrow cells cultured on CP titanium and Ti-6AI-4V or tissue culture plate. 3. Most bone marrow cells cultured on CP titanium, Ti-6Al-4V and tissue culture plate were attached well to each substratum in first 2days, and then, grew at higher growth rate. On the other hand, some cells cultured on Co-Cr-Mo alloy failed to attach in first 2 days, and then, attached cells grew at lower growth rate than other groups. 4. Attachment and growth rates of gingival fibroblasts cultured on CP titanium and Ti-6Al-4V showed no significant differences(p>0.05) compared to Co-Cr-Mo alloy in 2 days, but significantly greater increase(p<0.05) in 5 and 9 days. 5. There were no significantly differences(p>0.05) between growth rates on gingival fibroblasts cultured on CP titanium, Ti-6Al-4V and tissue culture plate in 2 and 5days, but a significant lower growth rate(p<0.05) on CP titanium and Ti-6Al-4V versus tissue culture plate. 6. Some gingival fibroblasts cultured on all specimen groups failed to attach, but attached cells grew well, especially on CP titanium, Ti-GAl-4V and tissue culture plate. 7. There were no significant differences(P>0.05) between growth rates of both bone marrow cells and gingival fibroblasts cultured on CP titanium and Ti-6AI-4V. As a result of this study, both commercially pure titanium and Ti-6AI-4V showed excellent biocompatibility and there was no significant difference in the cellular response to the both metals. Bone marrow cells cultured on each substratum showed significantly greater growth rate and responded sensitively to cytotoxic effects of metal surfaces compared to gingival fibroblasts. Considering cell response to the substrate, it was likely that the composition itself of titanium metals have no significant effect on the biocompatibility. Further study need to be done to evaluate the influence of surface characteristics on cellular responses.

  • PDF