• Title/Summary/Keyword: bone implants

Search Result 1,295, Processing Time 0.024 seconds

Non-gaseous Plasma Immersion Ion Implantation and Its Applications

  • Han, Seung-Hee;Kim, En-Kyeom;Park, Won-Woong;Moon, Sun-Woo;Kim, Kyung-Hun;Kim, Sung-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.151-151
    • /
    • 2012
  • A new plasma process, i.e., the combination of PIII&D and HIPIMS, was developed to implant non-gaseous ions into materials surface. HIPIMS is a special mode of operation of pulsed-DC magnetron sputtering, in which high pulsed DC power exceeding ~1 kW/$cm^2$ of its peak power density is applied to the magnetron sputtering target while the average power density remains manageable to the cooling capacity of the equipment by using a very small duty ratio of operation. Due to the high peak power density applied to the sputtering target, a large fraction of sputtered atoms is ionized. If the negative high voltage pulse applied to the sample stage in PIII&D system is synchronized with the pulsed plasma of sputtered target material by HIPIMS operation, the implantation of non-gaseous ions can be successfully accomplished. The new process has great advantage that thin film deposition and non-gaseous ion implantation along with in-situ film modification can be achieved in a single plasma chamber. Even broader application areas of PIII&D technology are believed to be envisaged by this newly developed process. In one application of non-gaseous plasma immersion ion implantation, Ge ions were implanted into SiO2 thin film at 60 keV to form Ge quantum dots embedded in SiO2 dielectric material. The crystalline Ge quantum dots were shown to be 5~10 nm in size and well dispersed in SiO2 matrix. In another application, Ag ions were implanted into SS-304 substrate to endow the anti-microbial property of the surface. Yet another bio-application was Mg ion implantation into Ti to improve its osteointegration property for bone implants. Catalyst is another promising application field of nongaseous plasma immersion ion implantation because ion implantation results in atomically dispersed catalytic agents with high surface to volume ratio. Pt ions were implanted into the surface of Al2O3 catalytic supporter and its H2 generation property was measured for DME reforming catalyst. In this talk, a newly developed, non-gaseous plasma immersion ion implantation technique and its applications would be shown and discussed.

  • PDF

A THREE DIMEMSIONAL PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTING BONE TISSUE ACCORDING TO DESIGN OF ATTACHMENTS USED FOR MANDIBULAR OVERDENTURE USING TWO OSSEOINTEGRATED IMPLANSTS (두개의 골유착성 임프란트를 이용한 하악 OVERDENTURE에서 ATTACHMENT 설계에 따른 임프란트 지지조직의 삼차원적 광탄성 응력분석)

  • Shin, Kyoo-Hag;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hie-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.31-69
    • /
    • 1996
  • The purpose of this investigation was to analyze stress distribution in implant supporting tissue according to different types of attachments such as combination bar attachment, Hader bar attachment, O-Ring attachment and Dal-Ro attachment that are used in mandibular overdenture by using two osseointegrated implants, to study the influence that POM IMC used in bar type attachment has in implant supporting tissue and compare the preceding analyses to find out an effective stress distribution method. Three dimensional photoelastic method was used to obtain the following results. (A) Analysis of stress distribution according to attachment type 1. Under vertical load condition, compressive stress was seen at implant supporting area of working side on all the photoelastic models but in Hader bar attachment tensional stress was seen at distal upper area of implant supporting area. Relatively Hader bar and O-Ring attachment showed even stress distribution pattern. 2. Under vertical load condition, compressive stress at implant apex area and tensional stress at implant lateral supporting area were seen at nonworking side of all models. 3. Under $25^{\circ}$ lateral load condition, general compressive stress was seen at working side implant supporting area in most of the models, especially at distal upper supporting area higher compressive stress concentration was seen in combination bar attachment and tensional stress concentration, in Hader bar attachment. 4. Under $25^{\circ}$ lateral load condition, compressive stress at implant apex area and tensional stress at implant lateral supporting area were seen at nonworking side of all models, except O-Ring model which showed compressive stress only. (B) Influence of POM IMC to stress distribution in bar type attachment 5. Under vertical load condition, better stress distribution pattern was seen at working side of combination bar and Hader bar attachment model using POM IMC. 6. Under vertical load condition, stress value was increased at nonworking side of combination bar attachment model using POM IMC and tendency of increasing compression was seen at nonworking side of Hader bar attachment model using POM IMC. 7. Under $25^{\circ}$ lateral load condition, better stress distribution pattern was seen at working side of combination bar attachment model using POM IMC but tendency of increasing stress was seen on working side of Hader bar attachment model using POM IMC. 8. Under $25^{\circ}$ lateral load condition, stress reduction was seen at nonworking side of combination bar attachment model using POM IMC but tendency of increasing stress was seen at nonworking side of Hader bar attachment model using POM IMC.

  • PDF

The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment (변형된 임플란트 임시 지대주의 물성에 대한 연구)

  • Yang, Byung-Duk;Yoon, Tae-Ho;Choi, Un-Jae;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

The effect of horizontal microgap location on the bone loss around 2-piece implants (2-piece 임플란트에서 미세 간극의 수평적 위치 변화에 따른 골 소실 비교 연구)

  • Kim, Jae-Il;Lee, Yong-Moo;Yang, Byoung-Keon;Ku, Young;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.83-91
    • /
    • 2004
  • 2-piece 임플란트에서는 초기 치유 기간 동안 0.9-1.6mm의 골 소실이 일어나는데 2-piece 임플란트의 미세 간극과 그에 따른 생물학적 폭경의 형성이 중요한 원인이다. 최근 수직적으로 미세 간극의 위치를 변화시킴으로 골 소실의 양을 줄일 수 있다는 보고가 있다. 이번 실험의 목적은 미세 간극의 수평적 위치 변화에 따른 골 소실의 양을 비교하는데 있다. 하악에서 인접하여 최소 2개의 임플란트를 식립할 수 있는 7 무치악 부위에 총 15개의 Osseotitie XP 4/5를 식립하였다. 이때 임플란트의 상연이 주위 치조골과 일치하게 식립하였고 무작위로 선택하여 한 그룹(W군)에서는 wide diameter healing abutment를 연결하였고 다른 한 그룹(S 군)에서는 standard diameter healing abutment를 연결하였다. 3개월의 치유 기간후 보철 과정을 시작하였으며 이 때 healing abutment와 같은 크기의 prosthetic component를 이용하였다. 임플란트 식립 직후, 3개월의 치유 기간이 지난 보철 직전(Interval I)에, 보철 과정 직후(Interval II)에 각각 치근단 방사선 사진을 찍어 각 단계에서의 골 소실 양을 비교하였다. W 군의 경우 골 소실의 양이 Interval I에서 $1.60{\pm}0.78$, Interval I+II에서 $2.36{\pm}0.29$이었고 S 군에서는 Interval I에서 $1.5810{\pm}0.3030$, Interval I+II에서는 $1.7346{\pm}0.4199$이었다. W군에서는 Interval I와 I+II에서의 골 소실 양이 통계학적으로 유의할 만한 차이를 보였으며, Interval I+II에서의 W 군과 S 군에서의 골 소실 양도 통계학적으로 유의할 만한 차이를 나타내었다. Interval I에서는 두 그룹에서 골 소실의 차이가 없었는데 이는 1 stage surgery시 healing abutment 주위로 mucoperiosteal flap 접합의 어려움 때문으로 생각된다. 한편 Interval II에서는 abutment manipulation 등의 과정이 추가적인 골 소실을 야기한 것으로 생각된다. Interval I+II에서 W 군과 S 군 사이의 골 소실 양 차이는 미세 간극의 수평적 위치 변화의 양과 유사한 결과를 나타내었는데 이로 미루어 미세 간극의 수평적 이동은 임플란트 주위의 골 소실 양에 영향을 미칠 수 있다고 생각된다.

The Endotoxin Assay of Contaminated Titanium Implants following Various Techniques of Detoxification (오염된 임프란트 표면의 해독 방법에 따른 내독소 제거 효과에 관한 연구)

  • Park, Joong-Hee;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.71-81
    • /
    • 2004
  • Peri-implantitis could be the result of biomechanical and occlusal overload as well as microbiologic invasion. The dental implant may be more susceptible to dental plaque than the natural tooth, as the predictability of a stable soft tissue attachment complex has not yet been confirmed. With the development of peri-implantitis, the implant surface would be exposed to the oral environment and becomes coated with bacteria. The objective of therapy for this condition is to regain integration of the implant with bone. Since fibroblast adherence to surfaces is impeded by endotoxin, it would seem that decontamination would be desirable to obtain maximum osseointegration. The purpose of this study was to determine whether various chemotherapeutic and mechanical treatments(distilled water, air-powder abrasive, hypersaturated citric acid, tetracycline) can detoxify contaminated titanium implant surface by means of kinetic LAL test. Experimental rough surface titanium disks were fabricated. All of them were divided into two groups(A.a group and P.g group) and each contaminated by A. actinomycetemcomitans and P. gingivalis suspension. Contaminated disks were treated with distilled water, air-powder abrasive, citric acid and tetracycline, and then all disks were placed into LPS-free water for elution. The results were as follows : 1. In A.a group, LPS elute level of all test groups were significantly lower than control group(p<0.05). 2. In A.a group, LPS elute level of test 2, test 3 and test4 groups were significantly lower than that of control group(p<0.05). But, among the test 2, test 3, test4 groups, the significant differences were not detected. 3. In P.g group, LPS elute level of test 2, test 3 and test 4 groups were lower than that of control group(p<0.05). But, among the test groups, the significant differences were not detected. From the result of this study, it would be concluded that air-powder abrasive, hypersaturated citric acid and tetracycline treatments may be effective at reducing endotoxin level on rough titanium implant surfaces, and can be clinically used. But the treatments in peri-implantitis differentially impact osseointegration making one method clinically superior. To gain this knowledges, further molecular biologic and histopathologic studies should be developed.

FINITE ELEMENT ANALYSIS OF STRESSES INDUCED BY OSSEOINTEGRATED PROSTHESES WITH OR WITHOUT CONNECT10N BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED ABUTMENTS (골 유착성 임프란트 보철수복시 자연지대치와의 고정유무에 따른 유한요소법적 응력분석)

  • Ko, Heon-Ju;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.147-160
    • /
    • 1991
  • The purpose of this study was to examine, by the method of finite element analysis, how implant geometry with or without connection between natural tooth and osseointegrated abutments affected the stress distribution in surrounding bone and osseointegrated prosthesis. The mandibular first and second molars were removed and the two osseointegrated implants were placed in the first and second molar sites. Stress analysis induced by prostheses with connection(Model A)or without connection(Model B) between natural tooth(second bicuspid) and two osseointegrated abutments(first molar and second molar) was performed under vertical point load(Load P1) or distributed point load(Load P2). The results were as follows; 1. Under vertical point load, mesial tilting was shown in both Model A and Model B and inferior displacement of Model A was greater than that of Model B in the second bicuspid. 2. Under vortical point load, the first and second molars showed mesial tilting in both Model A and Model B, and inferior displacement of them was similar in Model A and Model B and was less than that of the second bicuspid. 3. Under distributed point load, mesial displacement was shown in Model A and Model B and inferior displacement of Model A was less than that of Model B in the second bicuspid. 4. Under distributed point load, mesial tilting was shown and inferior displacement of Model A was similar to that of Model B in the first and second molars. 5. In Model A under vertical point load, high stress was concentrated in the corneal portion of first molar and distributed throughout the second molar and the second bicuspid, and the stress distribution of the second molar was greater than that of the second bicuspid. 6. In Model B under vertical point load, high stress was concentrated in the coronal and mesio-cervical portion of the first molar. 7. In Model A under distributed point load, high stress was concentrated in the mesio-cervical portion of the first molar and evenly distributed throughout the second molar and the second bicuspid. 8. In Model B under distributed point load, high stress was concentrated in the disto-cervical portion of the second bicuspid and evenly distributed throughout the first and second molars.

  • PDF

Clinical Availability of Waters' Projection in Sinus Elevation Procedures (상악동 거상술 시 Waters' Projection의 유용성에 대한 임상적 연구)

  • Seo, Mi Hyun;Kim, Soung Min;Ha, Ji Young;Lee, Jeong Keun;Myoung, Hoon;Lee, Jong Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.2
    • /
    • pp.88-93
    • /
    • 2013
  • Purpose: Maxillary sinus elevation has been widely used to enable insertion of endosseous implants in severely resorbed maxilla. Maxillary sinusitis after this procedure was considered to be the major drawback, therefore, preoperative evaluation of paranasal sinus is considered to be important. In order to evaluate the condition of the sinus, we used Waters' projection. In this study, asymptomatic patients were evaluated by Waters' view, and compared to timing to assess the sinus cavity. Methods: The retrospective study was based on 14 patients who were performed sinus elevation surgery in Seoul National University Dental Hospital. These patients did not show any signs of maxillary sinusitis. These patients were taken Waters' view at preoperative, postoperative 1 day, 3 months, 6 months. In Waters' view, presence of air fluid level, radiopacity of sinus wall, or radiopacity of entire maxillary sinus were evaluated. The density, and sinus dimension changes were assessed using Adobe Photoshop CS5$^{(R)}$ (Adobe Systems Inc., San Jose, CA, USA). Results: Findings of Waters views in patients with clear maxillary sinus at preoperative time were followed by elevated sinus floor with transplanted bone, mucosal swelling, and air fluid level. At postoperative 3 months, and 6 months, the radiographic findings were similar to preoperative state. By contrast, patients with preoperative mucosal swelling, or haziness in sinus cavity showed radiopacity entire sinus in Waters' view. In cases of the patients who were treated with simultaneous treatment to mucosal swelling, good status of sinus cavity were found. Conclusion: Although Waters' projections provide the limited information, and is less sensitive method compared with computed tomography, it is simple, easy, and economical method to assess of maxillary sinus. We suggest using Waters' view as radiographic routine tool for evaluation of sinus condition, especially in the sinus elevation surgery.

Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study (한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구)

  • Yoon, Yong-Cheol;Oh, Jong-Keon;Kim, Young-Woo;Kim, Hak Jun;Moon, Hong Joo;Kim, Nam-Ryeol
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants (치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구)

  • Kim, Hee-Eun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.209-223
    • /
    • 2013
  • This study was to evaluate the stress distributions of prefabricated, customized abutments and fixtures according to their material and shape by three-dimensional finite element analysis. And to investigate the fatigue life and fracture characteristics. Mandibular models were fabricated by reconstruction of the CT scan of patients with normal occlusion. A total of six finite element models were designed, a load of 100 N was applied on the buccal cusps vertically, and 30 degree obliquely. 10 specimens each were fabricated for the more clinically widely used 4 type abutments and were loaded according to ISO 14801. Differences in stress distribution patterns were not found according to the materials of the abutments and fixtures. But a slight difference in the stress level was detected. Customized abutment groups showed lower crown stress levels. One-piece zirconia implant showed the lowest bone stress levels. In the fatigue test, highest values were measured in group 7. Prefabricated abutments showed less variation of fatigue life (P<0.05). Use of customized abutments can improve the fracture resistance of restorations. Especially, use of customized zirconia abutments reinforced by titanium screw connecting parts is recommended.

Blood Vessel Regeneration using Human Umbilical Cord-derived Endothelial Progenitor Cells in Cyclophosphamide-treated Immune-deficient Mice

  • Kwon, Soon-Keun;Ko, Yu-Jin;Cho, Tae-Jun;Park, Eu-Gene;Kang, Byung-Chul;Lee, Gene;Cho, Jae-Jin
    • International Journal of Oral Biology
    • /
    • v.36 no.3
    • /
    • pp.117-122
    • /
    • 2011
  • Endothelial cells are a vital constituent of most mammalian organs and are required to maintain the integrity of these tissues. These cells also play a major role in angiogenesis, inflammatory reactions, and in the regulation of thrombosis. Angiogenesis facilitates pulp formation and produces the vessels which are essential for the maintenance of tooth homeostasis. These vessels can also be used in bone and tissue regeneration, and in surgical procedures to place implants or to remove cancerous tissue. Furthermore, endothelial cell regeneration is the most critical component of the tooth generation process. The aim of the present study was to stimulate endothelial regeneration at a site of acute cyclophosphamide (CP)-induced endothelial injury by treatment with human umbilical cord-derived endothelial/mesenchymal stem cells (hEPCs). We randomly assigned 16 to 20-week-old female NOD/SCID mice into three separate groups, a hEPC ($1{\times}10^5$ cells) transplanted, 300mg/kg CP treated and saline (control) group. The mice were sacrificed on days 5 and 10 and blood was collected via the abdominal aorta for analysis. The alanine transaminase (ALT), aspartate aminotransferase (AST), serum alkaline phosphatase (s-ALP), and albumin (ALB) levels were then evaluated. Tissue sections from the livers and kidneys were stained with hematoxylin and eosin (HE) for microscopic analysis and were subjected to immunohistochemistry to evaluate any changes in the endothelial layer. CP treatment caused a weight reduction after one day. The kidney/body weight ratio increased in the hEPC treated animals compared with the CP only group at 10 days. Moreover, hEPC treatment resulted in reduced s-ALP, AST, ALT levels compared with the CP only group at 10 days. The CP only animals further showed endothelial injuries at five days which were recovered by hEPC treatment at 10 days. The number of CD31-positive cells was increased by hEPC treatment at both 5 and 10 days. In conclusion, the CP-induced disruption of endothelial cells is recovered by hEPC treatment, indicating that hEPC transplantation has potential benefits in the treatment of endothelial damage.