• Title/Summary/Keyword: bone healing

Search Result 1,026, Processing Time 0.035 seconds

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS: HISTOMORPHOMETRIC AND RESONANCE FREQUENCY ANALYSIS IN DOGS

  • Song Woo-Seok;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.671-678
    • /
    • 2004
  • Statement of problem. Reducing treatment time in implant dentistry is a matter of main concern. There are so many factors affecting the success rate of immediate or early loaded implant for the initial bone response. The especially microscopic properties of implant surfaces playa major role in the osseous healing of dental implant. Purpose. The aims of this study were to perform a histologic and histomorphometric comparison of the healing characteristics anodically roughened surface, HA coated surface and RBM surface implant, and to compare of ISQ values measured by $Osstell^{TM}$ for resonance frequency analysis in dogs mandible during 2 weeks. Material and method. Bone blocks from 2 dogs were caught after covered healing for 0 day(2 h); Group I, 1 week; Group II and 2 weeks; Group III. One longitudinal section was obtained for each implant and stained with hematoxylin and eosin. Histomorphometric analysis was done with Kappa Imagebase system to calculate bone-to-implant contact and bone volumes inside the threads. ISQ values were measured in every time of surgery schedule. Conclusion. The experiment revealed that: 1. The percentages of bone-to-implant contact on the fixture in each group were not significantly different(P > 0.05). 2. The percentages of bone area inside the threads on the fixture in each group were not significantly different(P > 0.05). 3. The ISQ level showed clinical stability of each fixture during 2 weeks(all ISQ level ${\geq}71$ ).

In vivo comparison between the effects of chemically modified hydrophilic and anodically oxidized titanium surfaces on initial bone healing

  • Lee, Hyo-Jung;Yang, Il-Hyung;Kim, Seong-Kyun;Yeo, In-Sung;Kwon, Taek-Ka
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.3
    • /
    • pp.94-100
    • /
    • 2015
  • Purpose: The aim of this study was to investigate the combined effects of physical and chemical surface factors on in vivo bone responses by comparing chemically modified hydrophilic sandblasted, large-grit, acid-etched (modSLA) and anodically oxidized hydrophobic implant surfaces. Methods: Five modSLA implants and five anodized implants were inserted into the tibiae of five New Zealand white rabbits (one implant for each tibia). The characteristics of each surface were determined using field emission scanning electron microscopy, energy dispersive spectroscopy, and confocal laser scanning microscopy before the installation. The experimental animals were sacrificed after 1 week of healing and histologic slides were prepared from the implant-tibial bone blocks removed from the animals. Histomorphometric analyses were performed on the light microscopic images, and bone-to-implant contact (BIC) and bone area (BA) ratios were measured. Nonparametric comparison tests were applied to find any significant differences (P<0.05) between the modSLA and anodized surfaces. Results: The roughness of the anodized surface was $1.22{\pm}0.17{\mu}m$ in Sa, which was within the optimal range of $1.0-2.0{\mu}m$ for a bone response. The modSLA surface was significantly rougher at $2.53{\pm}0.07{\mu}m$ in Sa. However, the modSLA implant had significantly higher BIC than the anodized implant (P=0.02). Furthermore, BA ratios did not significantly differ between the two implants, although the anodized implant had a higher mean value of BA (P>0.05). Conclusions: Within the limitations of this study, the hydrophilicity of the modSLA surface may have a stronger effect on in vivo bone healing than optimal surface roughness and surface chemistry of the anodized surface.

The evaluation of healing patterns in surgically created circumferential gap defects around dental implants according to implant surface, defect width and defect morphology

  • Im, Se-Ung;Hong, Ji-Youn;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Keun;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.sup2
    • /
    • pp.385-394
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the factors affecting healing patterns of surgically created circumferential gap defects around implants in dogs. Materials and Methods: In four mongrel dogs, all mandibular premolars were extracted. After 8 weeks of healing periods, implants were submerged. According to the surface treatment, turned surface was designated as a group A and rough surface as a group B. In each dog, surgical defects on the left side were made with a customized tapered step drill and on the right with a customized paralleled drill. Groups were also divided according to the width of the coronal gaps: 1.0mm, 1.5mm, or 2.0mm. The dogs were sacrificed following 8 weeks and the specimens were analyzed histologically and histomorphometrically. Results: During the postoperative period, healing was uneventful and implants were well-maintained. As the size of the coronal gap was increased, the amount of bone-to-implant contact was decreased. The bone healing was greater in rough surface implants compared to the turned ones. About the defect morphology, tapered shape showed much bone healing and direct bone to implant contact even in the smooth surface implants. Conclusion: Healing of the circumferential defect around dental implant is influenced by the implant surface, defect width and the morphology of the defect. When using rough surface implants, circumferential gap defects within 2 mm do not need any kinds of regenerative procedures and the healing appeared to be faster in the tapered defect morphology than the paralleled one.

Guide bone regeneration using autogenous teeth: case reports (자가치아골이식재를 이용한 골유도재생술: 증례보고)

  • Kim, Young-Kyun;Lee, Hyo-Jung;Kim, Kyung-Wook;Kim, Su-Gwan;Um, In-Woong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.2
    • /
    • pp.142-147
    • /
    • 2011
  • The authors installed implants combined with guided bony regeneration (GBR) using autogenous tooth bone graft material in the patients. In one patient, GBR and simultaneous implant placement were performed. In two patients, GBR was performed and the implants were placed after 6 months. All patients achieved favorable clinical outcomes. Excellent osteoconductive bony healing was observed in the 6 month histology examination after the bone graft.

Case Report of Squamous-cell Carcinoma of the Mandibular Gingiva with Invasion of The Bone, Treated by Resection and Tibial Bone Graft (악골결손부에 경골이식술로 성형한 치험예)

  • Kim, Kwang-Hyun;Kim, Hong-Ki;Choi, Mock-Kyun
    • The Journal of the Korean dental association
    • /
    • v.11 no.3
    • /
    • pp.195-198
    • /
    • 1973
  • The authors have treated a squamous-cell carcinoma occurred in molar region of the right mandible in 52-year old woman by means of bony resection and banked tibial bone graft, and made the normal appearance of her face. The result as follow: 1) The healing of a graft is similar to the healing of an uninfected fracture except that it will take considerably longer. It is of the utmost importance that it should be well immobilized, otherwsie there is danger of absorption of bone and fibrous union. 2) Until the graft acquires a blood supply it is easily infected, for it has no defence against organisms, so it is most important to prevent wound infection set in.

  • PDF

Usefulness of Multiphase Scaffolds for Improving Tendon to Bone Healing for Rotator Cuff Tears in Shoulder (회전근개파열에서 힘줄뼈부착부 개선을 위한 다상 스캐폴드의 유용성)

  • Lee, Sang Chul
    • Clinical Pain
    • /
    • v.19 no.2
    • /
    • pp.59-63
    • /
    • 2020
  • Rotator cuff tear is often cited as a reason for shoulder pain and dysfunction in patients > 40 years of age. Surgical repair of rotator cuff tear is one of the most commonly performed orthopedic surgical procedures. Until now, the success rate of surgical repair for rotator cuff tear has not been satisfactory. Many factors influence the process of rotator cuff repair such as the presence of tendinosis and fatty infiltration, but the main factor is the difficulty in achieving healing at the tendon to bone interface. There is a clinical need for bioengineering approaches to promote regeneration of the native enthesis and reduce the poor outcomes after surgical repair. Toward this end, the design and fabrication of multiphasic or hierarchically structured scaffolds have received great attention. This manuscript deals with information on the tendon to bone interface and tries to find out why a multiphasic scaffold is necessary to reproduce it and considerations that need to be taken into to make an ideal scaffold.

Tooth Autotransplantation with Autogenous Tooth- Bone Graft: A Case Report

  • Kim, Young-Kyun;Choi, Yong-Hoon
    • Journal of Korean Dental Science
    • /
    • v.4 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • The extracted right mandibular third molar of a 37-year-old man was transplanted into the first molar area, and a bone graft procedure using autogenous tooth-bone graft material was performed for the space between the root and the alveolar socket. Reattachment was achieved after 10 months. Therefore, autogenous tooth-bone graft material is considered reasonable for bone induction and healing in the autotransplantation of teeth.

Ultrasonographic Evaluation of the Bone Beating of the Experimentally Induced Bone Defect in Dogs (개에서 실험적 골결손 치유 반응에 대한 초음파 평가)

  • Park, Jin-Hee;Seong, Yun-Sang;Eom, Ki-Dong
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.258-262
    • /
    • 2006
  • This study was performed to evaluate the usefulness of gray-scale and power Doppler ultrasonography, and to compare with radiography for detection of the repairing in experimentally induced bone defects in dogs. In 4 adult beagle dogs bilateral bone defects were created in 8 canine femurs as sized as 5 mm diameter. Mean detection time of the ultrasonographic endosteal callus formations(mean $14.25{\pm}2.31$ days) was significantly shorter than that of the radiographic opacity chanees(mean $23.50{\pm}2.27$ days) in the defected region. Mean time of the neovascularizd flow signal(mean $6.00{\pm}3.59$ days) from the power Doppler ultrasonographic examination was significantly shorter than that of gray-scale ultrasonographic findings. With these results, gray-scale ultransonography and power Doppler ultrasonography can be used for an early detection modality for bone healing.

Osteogenic Potential of the Periosteum and Periosteal Augmentation for Bone-tunnel Healing

  • Youn Inchan;Suh J-K Francis;Choi Kuiwon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.101-110
    • /
    • 2005
  • Periosteum and periosteum-derived progenitor cells have demonstrated the potential for stimulative applications in repairs of various musculoskeletal tissues. It has been found that the periosteum contains mesenchymal progenitor cells capable of differentiating into either osteoblasts or chondrocytes depending on the culture conditions. Anatomically, the periosteum is a heterogeneous multi-layered membrane, consisting of an inner cambium and an outer fibrous layer. The present study was designed to elucidate the cellular phenotypic characteristics of cambium and fibrous layer cells in vitro, and to assess whether structural integrity of the tendon in the bone tunnel can be improved by periosteal augmentation of the tendon­bone interface. It was found the cells from each layer showed distinct phenotypic characteristics in a primary monolayer culture system. Specifically, the cambium cells demonstrated higher osteogenic characteristics (higher alkaline phosphatase and osteocalcin levels), as compared to the fibrous cells. Also in vivo animal model showed that a periosteal augmentation of a tendon graft could enhance the structural integrity of the tendon-bone interface, when the periosteum is placed between the tendon and bone interface with the cambium layer facing toward the bone. These findings suggest that extra care needs to be taken in order to identify and maintain the intrinsic phenotypes of the heterogeneous cell types within the periosteum. This will improve our understanding of periosteum in applications for musculoskeletal tissue repairs and tissue engineering.

Treatment of Peri-implantitis: Cases Report (임플란트 주위염의 치료: 증례보고)

  • Sung, Hun-Mo;Kim, Kyoung-Kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.2
    • /
    • pp.112-123
    • /
    • 2013
  • This study aims to investigate the clinical outcome following treatment of peri-implantitis lesions. Five subjects with 7 implants were treated with surgical approach. Four subjects with 6 implants were initially treated with non-surgical approach or hygiene control. However, inflammation was not resolved and more bone loss was found. Therefore, surgical treatment was performed. After surgical exposure of the defect, granulation tissue was removed and implant surface was treated using tetracycline and chlorhexidine. Then, the flaps were sutured. The wound healing was performed in a non-submerged mode. The present finding demonstrates stable results without progression of bone loss. In one subject, deep V shaped bone defect was filled with bone substitute (ICB, CanCellous Bone, Rockey Mountain Tissue Bank, USA), and resorbable membrane (Lyoplant$^{(R)}$, B.Braun Aesculap AG, Germany) was placed over the grafted defect and healing abutment was connected. However, the inflammation was not resolved and more bone loss was found. At one month after regenerative surgery, the implant was removed.