• 제목/요약/키워드: bolted steel connections

검색결과 122건 처리시간 0.019초

Development of miniature bar-type structural fuses with cold formed bolted connections

  • Guan, Dongzhi;Yang, Sen;Jia, Liang-Jiu;Guo, Zhengxing
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.53-73
    • /
    • 2020
  • A novel all-steel miniature bar-type structural fuse (MBSF) with cold formed bolted connections is developed in this study, which consists of a central energy dissipation core cut from a smooth round bar, an external confining tube and nuts. Three types of cross sections for the central energy dissipation core, i.e., triple-cut, double-cut and single-cut cross sections, were studied. Totally 18 specimens were axially tested under either symmetric or asymmetric cyclic loading histories, where the parameters such as cut cross sectional area ratio, length of the yielding portion and cross sectional type were investigated. Numerical simulation of 2 representative specimens were also conducted. An analytical model to evaluate the bending failure at the elastic portion was proposed, and a design method to avoid this failure mode was also presented. The experimental results show that the proposed MBSFs exhibit satisfactory hysteretic performance under both the two cyclic loading histories. Average strain values of 8% and 4% are found to be respectively suitable for designing the new MBSFs as the ultimate strain under the symmetric and asymmetric cyclic loadings.

Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns

  • Goldsworthy, H.M.;Gardner, A.P.
    • Structural Engineering and Mechanics
    • /
    • 제24권4호
    • /
    • pp.463-478
    • /
    • 2006
  • The design of structural frameworks for buildings is constantly evolving and is dependent on regional issues such as loading and constructability. One of the most promising recent developments for low to medium rise construction in terms of efficiency of construction, robustness and aesthetic appearance utilises concrete-filled steel tubular sections as the columns in a moment-resisting frame. These are coupled to rigid or semi-rigid connections to composite steel-concrete beams. This paper includes the results of a pilot experimental programme leading towards the development of economical, reliable connections that are easily constructed for this type of frame. The connections must provide the requisite strength, stiffness and ductility to suit gravity loading conditions as well as gravity combined with the governing lateral wind or earthquake loading. The aim is to develop connections that are stiffer, less expensive and easier to construct than those in current use. A proposed fabricated T-stub connection is to be used to connect the beam flanges and the column. These T-stubs are connected to the column using "blind bolts" with extensions, allowing installation from the outside of the tube. In general, the use of the extensions results in a dramatic increase in the strength and stiffness of the T-stub to column connection in tension, since the load is shared between membrane action in the tube wall and the anchorage of the bolts through the extensions into the concrete.

On the numerical assessment of the separation zones in semirigid column base plate connections

  • Baniotopoulos, C.C.
    • Structural Engineering and Mechanics
    • /
    • 제2권3호
    • /
    • pp.295-309
    • /
    • 1994
  • The present paper concerns the mathematical study and the numerical treatment of the problem of semirigid connections in bolted steel column base plates by taking into account the possibility of appearance of separation phenomena on the contact surface under certain loading conditions. In order to obtain a convenient discrete form to simulate the structural behaviour of a steel column base plate, the continuous contact problem is first formulated as a variational inequality problem or, equivalently, as a quadratic programming problem. By applying an appropriate finite element scheme, the discrete problem is formulated as a quadratic optimization problem which expresses, from the standpoint of Mechanics, the principle of minimum potential energy of the semirigid connection at the state of equilibrium. For the numerical treatment of this problem, two effective and easy-to-use solution strategies based on quadratic optimization algorithms are proposed. This technique is illustrated by means of a numerical application.

낙엽송 부재의 이중 전단 볼트 접합부 강도 성능 (Strength Property of Double Shear Bolted-Connections of Larch)

  • 박천영;김광모;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제33권1호통권129호
    • /
    • pp.7-16
    • /
    • 2005
  • 본 연구에서는 국산 낙엽송 부재를 이용한 이중 볼트 전단 접합부의 성능을 평가하였다. 주부재로 두께 39 mm, 89 mm, 139 mm, 189 mm로 제재된 국산 낙엽송 제재목과 국산 낙엽송으로 제조된 두께 80 mm, 140 mm, 170 mm 집성재를 사용하였으며, 측면 부재로는 동일 두께의 제재목과 6 mm 철판을 사용하였으며, 접합 철물로는 M12, M16, M20 볼트를 사용하였다. 접합부에 대한 하중 방향은 주부재와 측면 부재의 목리 경사에 대해 수직, 수평한 경우에 대하여 실시하였다. 다우얼 지압 강도 실험을 통해 부재의 다우얼 지압 강도를 산출하고, 볼트 휨 실험을 통해 볼트의 휨 강도를 구한뒤, 최종 볼트 접합부 실험을 통해 접합부 성능을 평가하였으며, 최종 결과는 EYM (European Yield Model)을 사용한 계산값과 비교 평가하였다. 연구 결과 국산 낙엽송 부재의 이중 전단 볼트 접합부 성능은 EYM을 사용하여 얻어진 계산값과 비교하였을 때 그에 상응하거나 그 이상임을 알 수 있었으며, 특히 측면 부재가 제재목인 경우는 거의 일치함을 알 수 있었다. 파괴 모드는 옹이나 건조 결함 등의 영향을 많이 받으며 주부재의 두께가 작을 경우는 mode I, 주부재가 커짐에 따라 mode III으로 옮겨감을 알 수 있었다.

Experimental study on the cyclic behaviour of bolted end-plate joints

  • Adany, Sandor;Calado, Luis;Dunai, Laszlo
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.33-50
    • /
    • 2001
  • In this paper an experimental study is performed on end-plate type joints. The test arrangement represents a column-base joint of a steel frame. Altogether six specimens were tested, each of them subjected to cyclic loading. The specimens were carefully designed by performing detailed preliminary calculations so that they would present typical behaviour types of end-plate joints. On the basis of the experimentally established moment-rotation relationship, the cyclic characteristics of each specimen have been calculated and compared to one another. The results are evaluated, qualitative and quantitative conclusions are drawn.

Post-Northridge WUF-B 접합부 골조의 내진 성능 평가 (Seismic Performance Evaluation of Post-Northridge WUF-B Connections Frame)

  • 한상환;문기훈;정지은;이기학
    • 한국강구조학회 논문집
    • /
    • 제19권6호
    • /
    • pp.751-760
    • /
    • 2007
  • 본 연구에서는 Welded Unreinforced Flange-Bolted web(WUF-B) 접합부로 설계된 골조의 내진 성능 평가를 수행 하였다. WUF-B 접합부의 설계는 FEMA 350에서 제시한 방법을 사용하였으며, FEMA 350에 따르면 WUF-B 접합부 골조를 보통모멘트 골조(Ordinary Moment Resisting Steel Frames: OMFSFs)로 사용을 제한하고 있다. 이를 위해 WUF-B 접합부 실험결과를 바탕으로 패널존 강도 비를 변수로 하여 Post-Northridge WUF-B 접합부 해석 모델을 제안하였다. 이 해석 접합부 모델을 이용하여 SAC Phase II에서 사용된 3층, 9층 골조를 모델링 하고 내진 해석을 수행하였다. 해석 방법 중 비선형 정적 푸쉬오버 해석을 통하여 Post-Northridge 접합부 골조의 연성능력과 최대 모멘트 강도비, 최대 층간변위비를 구하였고, Incremental Dynamic Analysis(IDA)를 통해 각 성능 레벨(IO, CP)지점에서의 최대 층간변위비를 구하였다. 해석 결과는 Pre-Northridge 접합부 골조와 ductile 접합부 골조의 성능과 비교 검토 하였으며 접합부 상세 보강이 이루어진 Post-Northridge 접합부 골조의 성능이 Pre-Northridige 접합부 골조보다 향상된 것을 확인 할 수 있었다.

CFT기둥과 H-형강보의 볼트 접합부에 관한 실험적 연구 (An Experimental study on the Bolted Moment Connection between H-Beam and CFT Column)

  • 박순규;노환근
    • 한국강구조학회 논문집
    • /
    • 제10권4호통권37호
    • /
    • pp.789-799
    • /
    • 1998
  • 본 연구의 목적은 CFT-기둥과H-형강보의 볼트를 이용한 접합부의 형식을 제안하는 데 있다. 본 연구에서는 직선형, 굽힘형, U자형, 기성제품 고장력 볼트를 이용한 아홉가지 형식의 접합부를 제안하였다. 이 아홉가지의 접합부 형식에 대하여 단순 인장 실험을 수행하였으며, 이 실험 결과에 의해 성능이 우수한 형태를 선정하여 단순 휨 실험을 수행하였다. 그리고 단순 휨 실험을 통해 보-기둥 접합부의 구조적인 거동을 비교 분석하였다. 단순 휨 실험의 분석 결과, 휨 접합부의 구조성능은 상당히 우수한 것으로 나타났으나 시공시 해결되어야 할 사항들이 남아 있는 것으로 나타났다.

  • PDF

Seismic performance of moment connections in steel moment frames with HSS columns

  • Nunez, Eduardo;Torres, Ronald;Herrera, Ricardo
    • Steel and Composite Structures
    • /
    • 제25권3호
    • /
    • pp.271-286
    • /
    • 2017
  • The use of Hollow Structural Sections (HSS) provides an alternative for steel buildings in seismic zones, with the advantage over WF columns that the HSS columns have similar resistance along both axes and enhanced performance under flexure, compression and torsion with respect to other columns sections. The HSS columns have shown satisfactory performance under seismic loads, such as observed in buildings with steel moment frames in the Honshu earthquake (2011). The purpose of this research is to propose a new moment connection, EP-HSS ("End-plate to Hollow Structural Section"), using a wide flange beam and HSS column where the end plate falls outside the range of prequalification established in the ANSI/AISC 358-10 Specification, as an alternative to the traditional configuration of steel moment frames established in current codes. The connection was researched through analytical, numerical (FEM), and experimental studies. The results showed that the EP-HSS allowed the development of inelastic action on the beam only, avoiding stress concentrations in the column and developing significant energy dissipation. The experiments followed the qualification protocols established in the ANSI/AISC 341-10 Specification satisfying the required performance for highly ductile connections in seismic zones, thereby ensuring satisfactory performance under seismic actions without brittle failure mechanisms.

3D Finite element analysis of end - plate steel joints

  • Drosopoulos, G.A.;Stavroulakis, G.E.;Abdalla, K.M.
    • Steel and Composite Structures
    • /
    • 제12권2호
    • /
    • pp.93-115
    • /
    • 2012
  • This paper presents a numerical investigation of the mechanical behaviour of extended end - plate steel connections including comparison with full size experiments. Contact and friction laws have been taken into account with nonlinear, three dimensional finite element analysis. Material and geometric nonlinearities have been implemented to the model, as well. Results are then compared with experimental tests conducted at the Jordan University of Science and Technology. According to the most significant observation of the analysis, a separation of the column flange from the extended end - plate occurs. Other important structural parameters of the connection, like the impact of some column stiffeners on the overall response, local buckling of the column and friction of the beam to column interface, have been examined as well.

Cyclic tests of steel frames with composite lightweight infill walls

  • Hou, Hetao;Chou, Chung-Che;Zhou, Jian;Wu, Minglei;Qu, Bing;Ye, Haideng;Liu, Haining;Li, Jingjing
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.163-178
    • /
    • 2016
  • Composite Lightweight (CL) insulated walls have gained wide adoption recently because the exterior claddings of steel building frames have their cost effectiveness, good thermal and structural efficiency. To investigate the seismic behavior, lateral stiffness, ductility and energy dissipation of steel frames with the CL infill walls, five one-story one-bay steel frames were fabricated and tested under cyclic loads. Test results showed that the bolted connections allow relative movement between CL infill walls and steel frames, enabling the system to exhibit satisfactory performance under lateral loads. Additionally, it is found that the addition of diagonal steel straps to the CL infill wall significantly increases the initial lateral stiffness, load-carrying capacity, ductility and energy dissipation capacity of the system. Furthermore, the test results indicate that the lateral stiffness values of the frames with the CL infill wall are similar to those of the bare steel frames in large lateral displacement.