• Title/Summary/Keyword: bolt distance

Search Result 65, Processing Time 0.024 seconds

Reliabilities of distances describing bolt placement for high strength steel connections

  • Oztekin, Ertekin
    • Structural Engineering and Mechanics
    • /
    • v.54 no.1
    • /
    • pp.149-168
    • /
    • 2015
  • In the bolted connections, bolt placements are generally described and are generally made in the direction of design effects and in the perpendicular direction to design effects. In these both directions, the reliability of the distance of bolts to the edges of connection plate and the distance of bolts to each other is investigated for high strength steel connections built up with high strength bolts in this study. For this purpose, simple SL (bearing type shear connection) and SLP (bearing type shear connection for body-fit bolts) type steel connections with St 52 grade steel plates with 8 different thicknesses and with 8.8D grade high strength bolts (HV) were constituted and analyzed under H (Dead Loads+Live Loads+Snow Loads+Roof Loads) and HZ (H Loads+Wind Loads+Earthquake Loads) loadings. Geometric properties, material properties and design actions were taken as random variables. Monte Carlo Simulation method was used to compute failure risk and the first order second moment method was used to determine the reliability indexes of those different distances describing the placement of bolts. Results obtained from computations have been presented in graphics and in a Table. Then, they were compared with some values proposed by some structural codes. Finally, new equations were constituted for minimum and maximum values of distances describing bolt placement by regression analyses performed on those results.

Change of Strength of High-Strength Bolted Connection Depending on Standard and Over Bolt Hole (표준공과 과대공을 갖는 고장력볼트 접합부의 강도변화)

  • Yang, Seung-Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.5
    • /
    • pp.605-612
    • /
    • 2012
  • A tension member that has a high-strength bolt fastened to a standard bolt hole increases structural resistance but causes problems from workability or economic perspectives. In this research, a total of 28 samples that have standard and over bolt holes as the tension member's high-strength bolted connection were made and a tension test was conducted. The change of strength of the connection has been confirmed by comparing the tension load of standard and over bolt hole samples obtained from the test results with the design strength due to net section and end distance. Samples made with over bolt holes had a lighter tension load than that of samples made with standard bolt holes, exceeded the design strength of present design standards, and although decrease in strength was inevitable due to the over bolt hole, their safety was satisfactory.

Shearing Strength Properties of Bolted, Drift-Pinned Joints of the Larix Glulam - Effects of Fastener Diameter, Slenderness and End-distance on Strength Properties - (낙엽송 집성재의 Bolt, Drift Pin 접합부의 전단강도 성능 평가 - 접합구 직경, 세장비, 끝면거리가 강도에 미치는 영향 -)

  • Kim, Keon-Ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.69-78
    • /
    • 2008
  • Shearing strength test in tension type was investigated to determine the shear resistance of bolt and drift-pin connection of domestic larix glulam. The specimen was connected with bolt and drift-pin in the inserted plate type, and only bolt in the side plate type. The diameter of bolt and drift-pin used in the experiment are 12, 16 and 20 mm. The hole of bolt was drilled at the end-distance 5 d and 7 d. Tension load was loaded in the direction parallel to grain. The shear resistance was evaluated according to end-distance through this, the yield load was compared with the experimental yield load, using Larsen's formula. The prototype design strength is based on the yield load of end-distance 7 d and the reduction factor of end-distance 5 d was calculated. The results were as follows. 1. The average of maximum load of drift-pin connection was higher by 3~30% at the inserted type than at bolt connection with increasing diameter. In bolt connection, the average of maximum load of the side type was 1.54~2.07 times higher than that of the inserted type. In the same diameter, the average of maximum load of end-distance 7 d was higher by 8~44% than that of 5 d. 2. The bearing stress was 1.16~1.41 times higher at the inserted connection than at drift-pin connection, and 1.37~1.86 times higher at 7 d than at 5 d. Also, when the slenderness ratio was below 7.5 at drift-pin connection and below 6.0 at inserted connection, the lateral capacity was good. 3. The ratio of the experimental yield load and the predicted yield load calculated by Larsen's formula proposed by Larsen was 0.80~1.10 at inserted connection, and 0.75~1.46 at side connection. 4. When the inserted bolt connection was based on the yield load of end-distance 7 d, the reduction factor was 0.89 at 12 mm connection, 0.93 at 16 mm and 0.85 at 20 mm. The reduction factor was 0.89 at 12 mm the inserted drift-pin connection, 0.93 at 16 mm, 0.93 at 20 mm. The reduction factor was 0.79 at the side connection of the 12 mm bolt connection and 0.80 at 16 mm.

Investigations on the bearing strength of stainless steel bolted plates under in-plane tension

  • Kiymaz, G.
    • Steel and Composite Structures
    • /
    • v.9 no.2
    • /
    • pp.173-189
    • /
    • 2009
  • This paper presents a study on the behavior and design of bolted stainless steel plates under in-plane tension. Using an experimentally validated finite element (FE) program strength of stainless steel bolted plates under tension is examined with an emphasis on plate bearing mode of failure. A numerical parametric study was carried out which includes examining the behavior of stainless steel plate models with various proportions, bolt locations and in two different material grades. The models were designed to fail particularly in bolt tear-out and material piling-up modes. In the numerical simulation of the models, non-linear stress-strain material behavior of stainless steel was considered by using expressions which represent the full range of strains up to the ultimate tensile strain. Using the results of the parametric study, the effect of variations in bolt positions, such as end and edge distance and bolt pitch distance on bearing resistance of stainless steel bolted plates under in-plane tension has been investigated. Finally, the results obtained are critically examined using design estimations of the currently available international design guidance.

Strengthening of bolted shear joints in industrialized ferrocement construction

  • Ismail, M.;Shariati, M.;Abdul Awal, A.S.M.;Chiong, C.E.;Chahnasir, E. Sadeghipour;Porbar, A.;Heydari, A.;Khorami, M.
    • Steel and Composite Structures
    • /
    • v.28 no.6
    • /
    • pp.681-690
    • /
    • 2018
  • This paper highlights results of some experimental work that deals with strengthening of bolted shear joints in thin-walled ferrocement structure where steel wires, bent into U-shape are considered as simple inserts around the bolt hole. The parameters investigated include the number of layers of wire mesh, edge distance of bolt hole, size and location of the inserts. Test results have shown that for small edge distance, failure occurred either in cleavage or shearing mode, and the strength of the joint increased with an increase in the edge distance. This continued up to an upper limit set by either tension or bearing failure. The experimental study further revealed that for a given edge distance the strength of a joint can significantly be enhanced by using U-inserts. The equations developed for predicting joint strength in ferrocement composites can also be modified to include the effects of the inserts with a good level of accuracy.

An Analysis of Plastic Deformation Developed During Interference Fitting of Disk Brake Hub Bolt (디스크 브레이크 허브 볼트의 억지 끼워 맞춤에서 발생하는 소성변형의 해석)

  • Lee, J.S.;Kwak, S.Y.;Kang, S.
    • Transactions of Materials Processing
    • /
    • v.17 no.6
    • /
    • pp.407-411
    • /
    • 2008
  • A brake system in automobile is one of the important parts that directly affect the safety of passengers. Particularly, disk brake module is applied to almost all kinds of automobile brake system due to its remarkable braking power and braking distance. In the disk brake module of an automobile, the bolt for tire wheel is assembled to the disk brake hub by interference fit(bolt pressing process). The process induces small deformation whose range is within tens of ${\mu}m$ and this deformation may cause the runout badness of the whole disk brake module, and even braking problems such as judder or squeal phenomena which makes the loss of braking efficiency. In this study, bolt pressing fit into hub was simulated by $ANSYS^{TM}$, a commercial structure analysis program. Also, the aspect and the cause of hub displacement were analyzed and the solution for decreasing runout of hub was proposed.

A Study on Serviceability of Oversized Bolt Hole in High-Tension Bolt Joint Subjected to Bending (휨을 받는 고장력볼트 체결부에서 과대공에 따른 사용성에 관한 연구)

  • Park, Jeong-Ung;Yang, Seung-Hyun;Jang, Suk-In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2831-2836
    • /
    • 2009
  • If a design load exceeding the frictional force of the contact surface is applied to the connection of steel members using a high-tension bolt friction joint, sliding occurs and the connection of the steel members bears the design load through the shear strength and bearing strength of the bolt and the base plate. The sliding distance can be determined by the tensile force of the bolt, the friction coefficient of the contact surface, and the position of the bolt in the base plate hole. This study measured and analyzed sliding according to standard bolt hole and oversize bolt hole when pure bending moment and tensile force were applied to high-tension bolt joints with different sizes of bolt holes made in the base plate and the cover plate. In a high-tension bolt joint receiving pure bending moment and tensile force, the load causing sliding in an oversize bolt hole was $74\sim94%$ of that in a standard bolt hole. In a member receiving tensile force, the sliding load ratio was lower when the size of oversize bolt holes in the base plate and the cover plate was large. In addition, the size of the oversize bolt hole in the base plate was more closely correlated with the change of sliding loadthan the size of the oversize bolt hole in the base plate.

The Static Strength Analysis of Prying Action for T-flange Shape Structure Using F10T High Strength Bolt (F10T 고장력 볼트를 이용한 T-형 플랜지형 구조물의 Prying Action에 따른 정적강도 해석)

  • Park, Myung-Kyun;Lee, Joong-Won;Koo, Bon-Sung
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.19-24
    • /
    • 2008
  • This paper presents and discusses the experimental results on the F10T high strength bolts used in the T-flange joint structure. The experimental works were carried out for the parameters which are flange web thickness, the distance between bolts, prying ratio. The results show that the working stress imposed to bolts decreases as the flange web thickness increases on the other hand the imposed stress to the bolts increases as the distance between two bolts increases. In other words the strength of the T-flange joint increased as the web flange thickness increases and the distance between two bolts decreases. The prying ratio is increased as the distance between two bolts increases and as the flange web thickness decreases However, the degree of stress decrease in flange thickness variation is not that high as the distance variation between two bolts. Finally the equation for predicting the failure stress in T-flange joint structure using F10T high strength bolts was suggested.

A Study on Shear Capacity and Behavior of Large Sized Concrete Anchorage System (대형 콘크리트 앵커시스템의 전단성능 및 거동특성에 관한 연구)

  • Kim, Kang Sik;Shin, Sung Woo;Lee, Kwang Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.82-91
    • /
    • 2011
  • In this study, 24 prototype specimens were tested to find out the shear behavior and strength of large anchorage system exceeding 50mm(2") in anchor bolt diameter($d_0$) and 635mm(25") in effective embedment depth($h_{ef}$) not addressed by ACI349-06 Appendix B. Test variables are anchor bolt diameter($d_0$ = 63.5, 76.2, 88.9mm), effective embedment depth($h_{ef}$=635, 762mm), and edge distance($c_1$=381, 508, 762mm). Concrete compressive strength is constant($f_{ck}$=38MPa). Test results ($V_{test}$) were overestimated by $V_{aci06}$(shear strength by ACI 349-06) and $V_{ccd}$(shear strength by CCD method). In large anchorage system exceeding 50mm(2") of anchor bolt diameter($d_0$) and 635mm(25") of anchor bolt effective embedment depth($h_{ef}$), the bolt diameter variation and effective embedment depth($h_{ef}$) has no influence on the shear strenth, But, according to the analysis results of the feature ratio on edge distance($c_1$) and anchor bolt diameter, the feature ratio become smaller, which means anchor bolt diameter is bigger, predicted ratio of test results and predicted equation is larger. It was found that anchor bolt diameter is immediate cause of deterioration in the shear capacity of large anchorage system. To improve and extend the validity of current design recommendations further theoretical and numerical work is needed.

Experimental study on standard and innovative bolted end-plate beam-to-beam joints under bending

  • Katula, Levente;Dunai, Laszlo
    • Steel and Composite Structures
    • /
    • v.18 no.6
    • /
    • pp.1423-1450
    • /
    • 2015
  • The paper presents the details and results of an experimental study on bolted end-plate joints of industrial type steel building frames. The investigated joints are commonly used in Lindab-Astron industrial buildings and are optimized for manufacturing, erection and durability. The aim of the research was to provide an experimental background for the design model development by studying load-bearing capacity of joints, bolt force distribution, and end-plate deformations. Because of the special joint details, (i.e., joints with four bolts in one bolt-row and HammerHead arrangements), the Eurocode 3 standardized component model had to be improved and extended. The experimental programme included six different end-plate and bolt arrangements and covered sixteen specimens. The steel grade of test specimens was S355, the bolt diameter M20, whereas the bolt grade was 8.8 and 10.9 for the two series. The end-plate thickness varied between 12 mm and 24 mm. The specimens were investigated under pure bending conditions using a four-point-bending test arrangement. In all tests the typical displacements and the bolt force distribution were measured. The end-plate plastic deformations were measured after the tests by an automatic measuring device. The measured data were presented and evaluated by the moment-bolt-row force and moment-distance from centre of compression diagrams and by the deformed end-plate surfaces. From the results the typical failure modes and the joint behaviour were specified and presented. Furthermore the influence of the end-plate thickness and the pretension of the bolts on the behaviour of bolted joints were analysed.