• 제목/요약/키워드: boiling temperature

검색결과 696건 처리시간 0.024초

Numerical investigation of the critical heat flux in a 5 × 5 rod bundle with multi-grid

  • Liu, Wei;Shang, Zemin;Yang, Shihao;Yang, Lixin;Tian, Zihao;Liu, Yu;Chen, Xi;Peng, Qian
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1914-1928
    • /
    • 2022
  • To improve the heat transfer efficiency of the reactor fuel assembly, it is necessary to accurately calculate the two-phase flow boiling characteristics and the critical heat flux (CHF) in the fuel assembly. In this paper, a Eulerian two-fluid model combined with the extended wall boiling model was used to numerically simulate the 5 × 5 fuel rod bundle with spacer grids (four sets of mixing vane grids and four sets of simple support grids without mixing vanes). We calculated and analyzed 11 experimental conditions under different pressure, inlet temperature, and mass flux. After comparing the CHF and the location of departure from the nucleate boiling obtained by the numerical simulation with the experimental results, we confirmed the reliability of computational fluid dynamic analysis for the prediction of the CHF of the rod bundle and the boiling characteristics of the two-phase flow. Subsequently, we analyzed the influence of the spacer grid and mixing vanes on the void fraction, liquid temperature, and secondary flow distribution. The research in this article provides theoretical support for the design of fuel assemblies.

포화상태 풀비등시 단일기포의 성장에 관한 연구 (Study on the Single Bubble Growth During Nucleate Boiling at Saturated Pool)

  • 김정배;이한춘;오병도;김무환
    • 대한기계학회논문집B
    • /
    • 제29권2호
    • /
    • pp.169-179
    • /
    • 2005
  • Nucleate boiling experiments on heating surface of constant wall temperature were performed using R113 for almost saturated pool boiling conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain a constant wall temperature condition of heating surface and to measure the heat flow rate with high temporal and spatial resolutions. Bubble images during the bubble growth were taken as 5000 frames per second using a high-speed CCD camera synchronized with the heat flow rate measurements. The bubble growth behavior was analyzed using the new dimensionless parameters for each growth regions to permit comparisons with previous experimental results at the same scale. We found that the new dimensionless parameters can describe the whole growth region as initial and later (thermal) respectively. The comparisons showed good agreement in the initial and thermal growth regions. In the initial growth region including surface tension controlled, transition and inertia controlled regions as divided by Robinson and Judd, the bubble growth rate showed that the bubble radius was proportional to $t^{2/3}$ regardless of working fluids and heating conditions. And in the thermal growth region as also called asymptotic region, the bubble showed a growth rate that was proportional to $t^{1/5}$, also. Those growth rates were slower than the growth rates proposed in previous analytical analyses. The required heat flow rate for the volume change of the observed bubble was estimated to be larger than the heat flow rate measured at the wall. Heat, which is different from the instantaneous heat supplied through the heating wall, can be estimated as being transferred through the interface between bubble and liquid even with saturated pool condition. This phenomenon under a saturated pool condition needs to be analyzed and the data from this study can supply the good experimental data with the precise boundary condition (constant wall temperature).

포화상태 풀비등시 단일기포의 성장에 관한 연구 (Study on the single bubble growth at saturated pool boiling)

  • 김정배;이한춘;오병도;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1933-1938
    • /
    • 2004
  • Nucleate boiling experiments with constant wall temperature of heating surface were performed using R113 for almost saturated pool boiling conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain a constant wall temperature condition and to measure the heat flow rate with high temporal and spatial resolutions. Bubble images during the bubble growth were taken as 5000 frames a sec using a high-speed CCD camera synchronized with the heat flow rate measurements. The geometry of the bubble during growth time could be obtained from the captured bubble images. The bubble growth behavior was analyzed using the new dimensionless parameters for each growth regions to permit comparisons with previous results at the same scale. We found that the new dimensionless parameters can describe the whole growth region as initial and later respectively. The comparisons showed good agreement in the initial and thermal growth regions. The required heat flow rate for the volume change of the observed bubble was estimated to be larger than the instantaneous heat flow rate measured at the wall. Heat, which is different from the instantaneous heat supplied through the heating wall, can be estimated as being transferred through the interface between bubble and liquid even with saturated pool conditions. This phenomenon under a saturated pool condition needs to be analyzed and the data from this study can supply the good experimental data with the precise boundary condition (constant wall temperature).

  • PDF

수평미세관내 NH3 비등열전달 특성 (Boiling Heat Transfer of Ammonia inside Horizontal Smooth Small Tube)

  • 최광일;오종택
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.101-108
    • /
    • 2013
  • This paper is presented an experimental study of flow boiling heat transfer characteristics of ammonia, and is focused on pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal small tube with inner diameter of 3.0 mm and length of 2000 mm. The direct heating method is applied for supplying heat to the refrigerant, where the test tube is uniformly heated by electric current. The local heat transfer coefficients were obtained over a heat flux range of 20 to $80kW/m^2$, a mass flux range of 50 to $500kg/m^2s$, a saturation temperature range of 0 to $10^{\circ}C$, and quality up to 1.0. The pressure drops increase with increasing mass flux and heat flux, and with decreasing saturation temperature. The heat transfer coefficients increase with increasing mass flux and saturation temperature in middle and high quality region. And the local heat transfer coefficient increase with increasing heat flux in low quality region. The heat transfer coefficient of the experimental result was compared with six existing heat transfer coefficient correlation. A new boiling heat transfer coefficient correlation based on the superposition model for ammonia in small tubes is developed average deviation of -0.17% and mean deviation of 10.85%.

질소의 끓는점에서의 산업용 온도계 비교 교정과 불확도 평가 (Calibration by Comparison and Uncertainty Assessment of Industrial Thermometers at the Boiling Point of Nitrogen)

  • 양인석;감기술;정욱철;김용규
    • 센서학회지
    • /
    • 제22권6호
    • /
    • pp.404-409
    • /
    • 2013
  • We devised calibration procedure for industrial thermometers by a comparison method at the boiling point of nitrogen (${\sim}-196^{\circ}C$). The uncertainty of the calibration was 4 mK (k = 2). As experimentally demonstrated in this work, the effect of the atmospheric pressure on the boiling point of nitrogen can be easily detected by the thermometer. Therefore, when the boiling point of nitrogen is used for calibration of thermometer by comparison, either a reference thermometer must be used to provide the reference temperature or the effect of atmospheric pressure should be carefully considered. The use of a copper block with a large thermal mass soaked into the liquid nitrogen was proven to be more reliable, and the stability of the temperature immersed into the copper block was 1.4 mK. The temperatures at the thermometer wells, evaluated by the crossed-measurement method to compensate for the inaccuracy of the thermometers and the linear drift of the temperature of the copper block, were equivalent within 0.23 mK of standard uncertainty.

주행하는 고온 강재의 상하부 동시 냉각 과정 수치해석 (Numerical Analysis of Simultaneous Cooling Process of Upper and Lower Side of Running Hot Steel Strip)

  • 권면재;박일석
    • 대한기계학회논문집B
    • /
    • 제38권12호
    • /
    • pp.1051-1056
    • /
    • 2014
  • 열간 압연을 거친 $800^{\circ}C$ 이상의 고온 철강 판재는 일반적으로 다중 봉상 수분류(multiple circular water jets)에 의해서 급속 냉각된다. 이 과정은 소재의 온도가 냉각수의 끓는점보다 훨씬 높기 때문에 소재 표면과 냉각수 사이에 막비등 열전달 현상이 발생하며 소재 표면에 매우 얇은 증기층이 형성되며, 이 증기층은 소재와 냉각수의 열교환을 방해하는 중요한 열저항으로 작용한다. 본 문제에는 비등 열전달 이외에도 소재 표면에 쌓이는 체류수의 자유표면 유동, 소재의 고속 주행 등 복잡한 물리현상들이 복합적으로 작용하고 있다. 본 논문에서는 이 모든 물리현상들을 동시에 고려할 수 있는 해석 절차를 적용하여 일정한 속도로 주행하는 고온 철강 판재의 상하부 동시 냉각 과정을 3 차원 수치해석 하였으며, 소재 상부 및 하부 면의 냉각 특성을 비교하였다.

평활관 및 와이어코일을 삽입한 열전달촉진관에서 액체질소의 흐름비등열전달 특성 (Flow Boiling Heat Transfer Characteristics of Liquid Nitrogen in Plain and Wire Coil Inserted Tubes)

  • 황지상;윤린;김용찬;정진택
    • 대한기계학회논문집B
    • /
    • 제29권8호
    • /
    • pp.927-933
    • /
    • 2005
  • Boiling heat transfer characteristics of liquid nitrogen in a stainless steel plain tube and wire coil inserted tubes were investigated. The test tubes, which had an inner diameter of 10.6 m and a length of 1.65 m, were horizontally located. Five wire coils having different pitch and thickness were inserted into the plain tube. The pitches of the wire coils were 18.4, 27.6, and 36.8 m, and the thickness was 1.5, 2.0, and 2.5 mm respectively. Tests were conducted at a saturation temperature of $-191^{\circ}$, mass fluxes from 58 to 105 kg/$m^2s$, and heat fluxes from 22.5 to 32.7 kw/$m^2$. A direct heating method was used to apply heat to the test section. The boiling heat transfer coefficients of liquid nitrogen were represented as a function of vapor quality, which showed significant drop at the dryout vapor quality. The maximum heat transfer enhancement using the wire coil inserted tubes over the plain tube was $174\%$ for 'Wire 3' having a thickness of 2.5 mm and a pitch of 18.4 mm.

열전달 촉진 표면에서 R1234yf의 풀 비등 열전달계수 (Pool Boiling Heat Transfer Coefficients of R1234yf on Various Enhanced Surfaces)

  • 이요한;강동규;서훈;정동수
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.143-149
    • /
    • 2013
  • In this work, nucleate pool boiling heat transfer coefficients (HTCs) of R134a and R1234yf are measured, on flat plain, 26 fpi low fin, Turbo-B, Turbo-C and Thermoexcel-E surfaces. All data are taken at the liquid pool temperature of $7^{\circ}C$, on a small square copper plate ($9.53mm{\times}9.53mm$), at heat fluxes from $10kW/m^2$ to $200kW/m^2$, with an interval of $10kW/m^2$. Test results show that nucleate boiling HTCs of all enhanced surfaces are greatly improved, as compared to that of a plain surface. Nucleate pool boiling HTCs of R1234yf are very similar to those of R134a, for the five surfaces tested.

Evaporating Heat Transfer Characteristics of R-l34a in a Horizontal Smooth Channel

  • Pamitran, A.S.;Choi, Kwang-Il;Oh, Jong-Taek;Oh, Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권4호
    • /
    • pp.156-165
    • /
    • 2006
  • Convective boiling heat transfer coefficients were measured in a horizontal minichannel with R-l34a. The test section was made of stainless steel tube with an inner diameter of 3.0 mm and a length of 2m. It was uniformly heated by applying electric current directly to the tube. Local heat transfer coefficients were obtained for heat fluxes from 10 to $40kW/m^2$, mass fluxes from 200 to $600kgT/m^2s$, qualities up to 1.0, and the inlet saturation temperature of $10^{\circ}C$. The experimental results were mapped on Wojtan et $al.'s^(7)$ and Wang et $al.'s^(8)$ flow pattern maps. The nucleate boiling was predominant at low vapor quality whereas the convective boiling was predominant at high vapor quality. Laminar flow appeared in the flow with minichannel. The experimental results were compared with six existing two-phase heat transfer coefficient correlations. A new boiling heat transfer coefficient correlation based on the superposition model for refrigerants was developed with mean and average deviations of 10.39% and -3.66%, respectively.

터보 냉동기용 핀 튜브에 관한 연구(II) - 비등 열전달에 관하여 - (A Study on Finned Tube Used in Turbo Refrigerator(II) - on boiling heat transfer -)

  • 한규일;김시영;조동현
    • 수산해양교육연구
    • /
    • 제5권2호
    • /
    • pp.119-127
    • /
    • 1993
  • This work studies for heat transfer and pressure drop performance of integral inner and outer fin tubes, designed to enhance the heat transfer performance of smooth tubes for in recipro and turbo refrigerator or high performance compact heat exchangers. Eight different inner spiral fin copper tubes with integral fin at outside surfaces were employed to improve boiling heat transfer coeffcient. For comparison, tests were made using a plain tube having the inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Pool boiling heat transfer is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at a saturation state of 1 bar on the outside tube surface heated by hot water. The refrigerant R11 ($CFCl_3$) was used at a pressure of $P_s=1bar$ as a convenient test fluid with a boiling temperature of $T_s=23.6^{\circ}C$. The observed heat transfer enhancement of boiling for finned tubes significantly exceeded that to be expected on grounds of increased area. The maximum Vapor - side enhancement(i.e., vapor - side heat transfer coefficient of finned tube/vapor - side coefficient for plain tube) was found to be around 4 at 1299fpm - 30grooves tube.

  • PDF