• 제목/요약/키워드: boiling effect

검색결과 555건 처리시간 0.027초

An Improved Mechanistic Model to Predict Critical Heat Flux in Subcooled and Low Quality Convective Boiling

  • Kwon, Young-Min;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • 제31권2호
    • /
    • pp.236-255
    • /
    • 1999
  • An improved mechanistic model was developed to predict a convective boiling critical heat flux (CHF) in the vertical round tubes with uniform heat fluxes. The CHF formula for subcooled and low quality boiling was derived from the local conservation equations of mass, energy and momentum, together with appropriate constitutive relations. The model is characterized by the momentum balance equation to determine the limiting transverse interchange of mass flux crossing the interface of wall bubbly layer and core by taking account of the convective shear effect due to the frictional drag on the wall-attached bubbles. Comparison between the present model predictions and experimental CHF data from several sources shows good agreement over a wide range of How conditions. The present model shows comparable prediction accuracy with the CHF look-up table of Groeneveld et al. Also the model correctly accounts for the effects of flow variables as well as geometry parameters.

  • PDF

삼차원 조도를 가진 성형가공관의 R-134a 풀비등 열전달 촉진에 관한 실험적 연구 (An Experimental Study on Pool Boiling Heat Transfer Enhancement of Structured Tubes Having Three-Dimensional Roughness)

  • 김내현
    • 설비공학논문집
    • /
    • 제28권5호
    • /
    • pp.195-201
    • /
    • 2016
  • Enhanced tubes are widely used in air-conditioning and process industries. Structural tubes having three-dimensional roughness are well known to be able to significantly enhance pool boiling heat transfer of refrigerants. In this study, five structural enhanced tubes having different fin density, fin height, and fin gap width were tested using R-134a. Results showed that the heat transfer coefficient was increased with increased fin density. Within test range, the effect of fin height on pool boiling heat transfer coefficient was insignificant. The heat transfer coefficients of the optimum configuration (2047 fpm, 0.21 mm gap width) tube were lower than those of other commercial enhanced tubes. This might be due to the larger fin gap width of the present enhanced tube.

An Improved Mechanistic Critical Heat Flux Model for Subcooled Flow Boiling

  • Young Min Kwon;Soon Heung Chang
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.552-557
    • /
    • 1997
  • Based on the bubble coalescence adjacent to the heated wall as a flow structure for CHF condition, Chang and Lee developed a mechanistic critical heat flux (CHF) model for subcooled flow boiling. In this paper, improvements of Chang-Lee model are implemented with more solid theoretical bases for subcooled and low-quality flow boiling in tubes. Nedderman-Shearer's equations for the skin friction factor and universal velocity profile models are employed. Slip effect of movable bubbly layer is implemented to improve the predictability of low mass flow. Also, mechanistic subcooled flow boiling model is used to predict the flow quality and void fraction. The performance of the present model is verified using the KAIST CHF database of water in uniformly heated tubes. It is found that the present model can give a satisfactory agreement with experimental data within less than 9% RMS error.

  • PDF

물-$TiO_2$ 나노유체 풀비등에서의 임계열유속 (Critical heat flux behavior in pool boiling of $water-TiO_2$ nanofluids)

  • 김형대;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1470-1474
    • /
    • 2004
  • 'Nanofluids' means suspension of common fluids with particles of the order of nanometers in size. The present research is an experimental study of critical heat flux (CHF) behavior in pool boiling of $water-TiO_2$ nanofluids under atmospheric pressure. CHF for pure water and $water-TiO_2$ nanofluids were respectively measured using disk-type copper block heater with 10mm diameter, and CHF of water with surfactant was also measured to consider the effect of surfactant used to disperse nanoparticle. The results show a large increase in CHF for $water-TiO_2$ nanofluids compared to pure water. After CHF occurred, heat flux in pool boiling for $water-TiO_2$ nanofluids was maintained in considerable value, but not for pure water.

  • PDF

열전달 향상을 위한 나노물질 코팅재료의 영향에 대한 연구 (Effect of nanoparticle material for heat transfer enhancement)

  • 전용한;김남진
    • Design & Manufacturing
    • /
    • 제13권1호
    • /
    • pp.42-47
    • /
    • 2019
  • Nucleate boiling heat transfer is one of the most important phenomenon in the various industries. Especially, critical heat flux (CHF) refers to the upper limit of the pool boiling heat transfer region. Therefore, many researchers have found that CHF can be significantly increased by adding very small amounts of nanoparticles. In this study, the CHF and heat transfer coefficient were tested under the pool boiling state using copper and multi wall carbon nanotube nanoparticles. The results showed that two different types of nanoparticles deposited on the surface of two specimens made of the same material increased the heat flux in the nanoparticles with high conductivity, and there was no difference in the critical heat flux when the same material nanoparticles were deposited on the two different specimen surfaces.

인젝터 압력이 단공노즐 감압비등 분무에 미치는 영향 (Effect of Injection Pressure on the Flash Boiling Spray from Simple Orifice Nozzle)

  • 이현창;차현우;강동현
    • 한국분무공학회지
    • /
    • 제27권1호
    • /
    • pp.42-49
    • /
    • 2022
  • Flash boiling occurs in a couple of modern engineering systems and understanding its mechanism is important. In this experimental study, discharge coefficient of flash boiling spray from simple orifice nozzle was measured, and backlight imaging was acquired at injection pressure to 6.0 bar and temperature to 163℃ for the purpose. Pressurized water by pump was used for working fluid and was heated by electric heater and ejected through simple orifice nozzle diameter of 0.5 mm. High speed camera with long distance microscope was used for backlight imaging in two FoV having magnification of 3.3 and 0.64. The decrease of discharge coefficient according to degree of superheating and evolution of flash boiling spray imaged at various pressure and temperature were explained by the pressure field inside the injector.

국내 젖병소독법의 실태조사 (A Survey of Disinfection Methods for Formula Bottle)

  • 이인혜;신영희;이은실
    • Child Health Nursing Research
    • /
    • 제10권1호
    • /
    • pp.108-116
    • /
    • 2004
  • Purpose: There has been a number of reports on elution of bisphenol-A, an endocrine disrupting chemical, from milk bottles, all concerning the potential health effect of the substance. In this study, we measured the elution of bisphenol-A from milk bottles during boiling-water sterilization, to suggest a safe sterilization method. Method: Through the survey of 200 mothers, 78.5% of them expressed their concern on the possible harmful effect of bisphenol-A, which might be eluted from the bottles. And it was found that most mothers use boiling-water to sterilize bottles; duration of boiling bottles could be divided into three groups of 3, 5, and 10 minutes. We measured the elution of bisphenol- A from three different brands of bottles, subject to various mode of sterilization found in the survey. Result: In all the measurements, the concentration of the eluted bisphenol-A was in the range of 0.3 - 0.7 ppb, far below 2.5ppm, the level set up by Korea Food %amp; Drug Administration(KFDA) for a potential harmful effect. Conclusion: Although trace amount of bisphenol -A can be eluted from polycarbonate milk bottles during sterilization, and bottle feeding, the amount is found to be too small to cause any health related impact for infants.

  • PDF

Convective Boiling of R-l34a in a Bundle of Smooth Tubes

  • Kim, Jung-Oh;Cho, Jin-Pyo;Kim, Nae-Hyun;Choi, Kuk-Kwang
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권2호
    • /
    • pp.79-87
    • /
    • 2002
  • In this study, flow boiling experiments were performed using R-134a on a plain tube bundle. Tests were conducted for the following range of variables; quality from 0.1 to 0.9, mass flux from 8kg/$m^2$s to 26 kg/$m^2$s and heat flux from 10kW/$m^2$ to 40kW/$m^2$. The heat transfer coefficients were strongly dependent on the heat flux. However, they were almost independent on the mass flux or quality. The data are compared with the modified Chen model, which predicted satisfactorily ($\pm$30%) the data. The Original Chen model, however, did not adequately predict the effect of quality. The reason may be attributed to the flow pattern of the present test, where the bubbly flow prevailed for the entire test range. The heat transfer coefficients of the tube bundle were 6~40% higher than those of the single tube pool boiling.

수평 원형전열관의 핀효과에 의한 응축 및 비등 열전달촉진에 관한 연구 (1)-튜브외부 비등- (A Study on the Improvement of Condensation and Boiling Heat Transfer on Horizntal Tube by Fin Effect(l)-Shellside Boiling-)

  • 한규일;조동현
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1264-1274
    • /
    • 1994
  • Heat transfer performance of integral-fin tube which is used in recipro turbo refrigerator or high compact heat exchangers is studied. Eight tubes with trapezoidal shaped integral-fins having fin densities from 748 to 1654 fpm and 10, 30 internal grooves are tested. A plain tube having the same(inner and outer) diameter as the fin tubes is also tested for comparison. Pool boiling heat transfer of R-11 is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at saturation state of 1 bar on the outside tube surface and heat is supplied by not water which circulates inside of the tube. From the result of eight fin tubes and one plain tube tested, a tube having 1299 fpm-30 grooves shows the best performance. A maximum overall heat transfer coefficient of this tube is about 4000 $W/m^{2}K$ at 2.8m/s of water velocity. The maximum heat transfer enhancement (i.e., the ratio of overall heat transfer coefficients of finned to plain tubes)is about 2.1.

가열시간이 소 사골과 갈비뼈의 영양성분 용출에 미치는 영향 (The Effect on the Nutritional Value of Beef Leg and Rib Bone Soup by Boiling Time)

  • 김명선
    • 한국식생활문화학회지
    • /
    • 제21권2호
    • /
    • pp.161-165
    • /
    • 2006
  • 소뼈의 효과적인 이용을 위하여 사골뼈와 갈비뼈의 가열시간에 따른 칼슘, 인, 마그네슘, 단백질, 총 유리 아미노산, 콜라겐 등의 영양성분 측정과 관능검사를 실시한 결과는 다음과 같다. 12시간 까지 가열할 경우, 조리시간이 경과할수록 고형물, 칼슘, 인, 마그네슘, 단백질, 총 유리아미노산, 콜라겐 함량은 점점 증가하였으며 12시간 가열에서 가장 높았으며, 이와 같은 영양성분이 사골뼈 보다 갈비뼈에서 조금 높게 용출되었다. 12시간 끓인 시료에 식염 0.8%를 첨가하여 관능 검사를 실시한 결과 색, 향기, 맛, 종합적인 맛에서 갈비뼈 시료가 사골뼈 시료보다 높은 기호도를 나타냈다. 이상의 결과들로부터 사골뼈와 갈비뼈를 12시간 가열함으로써 칼슘과 마그네슘 등 영양성분이 가용화되기 쉬우며, 사골뼈와 갈비뼈의 영양성분과 맛이 우수하므로 다양한 이용과 개발을 시사하였다.