• Title/Summary/Keyword: boil

Search Result 256, Processing Time 0.025 seconds

Breakdown Characteristics of Liquid Nitrogen in the Environment to Restrain Vapor Bubbles (비등 기포를 억제한 환경에서 액체 질소의 절연파괴 특성)

  • 백승명;정종만;김영석;곽동순;한철수;김상현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.228-231
    • /
    • 2003
  • Experimental investigations of AC breakdown characteristics of liquid nitrogen in the environment to restrain boil bubbles are presented in this paper. The environment to restrain vapor bubble in the liquid nitrogen is both increasing pressure and decreasing temperature. Measurements of the breakdown voltage of liquid nitrogen in the environment to restrain vapor bubbles are investigated under AC high voltage in a quasi-uniform and non-uniform electrical field for pressures and temperatures ranging from 0 to 0.5 MPa and 77 K to 65 K respectively.

  • PDF

Manufacturing and Tests of Cryostat for SMES (초전도에너지저장장치용 Cryostat 제작 및 특성시험)

  • Cho, J.W.;Sim, K.D.;Ha, H.S.;Kim, H.J.;Seong, K.C.;Kwon, Y.K.;Ryu, K.S.;Koh, D.Y.;Ryoo, C.S.;Kim, S.R.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.15-18
    • /
    • 2001
  • SMES consists of superconducting magnet, power converter and cryostat and HTS current lead. The prototype cryostat with HTS current leads and refrigerators was designed and manufactured for micro-SMES. HTS current lead with cryocooler was measured the temperature rise under dc current. The cryostat was evaluated the helium boil-off and mechanical stress during transfer and vibration test. These results will be applied to develope the micro-SMES system.

  • PDF

LNG운반선의 증발기체 재액화 장치의 사이클 해석

  • Jin, Yeong-Uk
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.04a
    • /
    • pp.221-232
    • /
    • 2012
  • Cycle analysis has been performed to find out the optimum design point of the BOG re-liquefaction plant. The cycle state, defined by three cycle variables, was mainly described by the three cold temperatures of the three-pass heat exchanger, on which the constraints by the heat exchanger are imposed. The cycle states which are confined within a domain limited by the temperature constraints were the primary issue of this study. The BOG mass within the domain was analyzed first and then the cycle performance was related to the BOG mass afterwards, which enabled us to explain the observed behavior of the cycle performance under the temperature constraints by the heat exchanger. A good cycle performance could be ensured if the two cold Nitrogen temperatures of the three temperatures were placed close together near $-140^{\circ}C$ while the BOG temperature is kept far above enough, but not too far, from $-140^{\circ}C$ such that it does not interfere in their optimum temperature range.

  • PDF

Containment Closure Time Following Loss of Cooling Under Shutdown Conditions of YGN Units 3&4

  • Seul, Kwang-Won;Bang, Toung-Seok;Kim, Se-Won;Kim, Hho-Jung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.647-652
    • /
    • 1998
  • The YGN Units 3&4 plant conditions during shutdown operation were reviewed to identified the possible even scenarios following the loss of shutdown cooling. The Thermal hydraulic analyses were performed for the five cases of RCS configurations under the worst event scenario, unavailable secondary cooling and no RCS inventory makeup, using the RELAP5/MOD3.2 code to investigate the plant behavior, From the analyses results, times to boil, times to core uncovery and times to core heat up were estimated to determined the containment closure time to prevent the uncontrolled released of fission products to atmosphere, These data provide useful information to the abnormal procedure to cope with event.

  • PDF

Experiment on Heat Loads Invaded into HTS Cable Cryostat under Cryogenic Insulation System (고온초전도 케이블용 cryostat의 단열조건에 대한 열침입량 측정)

  • Kim, Do-Hyeong;Jung, Won-Moog;Kim, Dong-Lak;Yang, Hyung-Suk;Cho, Seung-Yon;Hwang, Si-Dole
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1564-1569
    • /
    • 2004
  • Insulating a heat from the environment is the most important in cryogenic applications like HTS cable system. Vacuum and MLI(Multi-Layer Insulation) have been widely used to get highly efficient cryogenic insulation. In this study, experiment on annular cylinder regarded as basic model of HTS cable cryostat has been performed to measure the heat loads. To investigate the effectiveness of radiation shields in cryogenic insulation system, the experiments are carried out to various number of the shields. The measured values are compared with the results estimated theoretically. The heat loads invaded from the environment was determined by liquid nitrogen boil-off calorimetry.

  • PDF

A Study on the Centrifuge Fabrication for a Nano Size Particle Having a Central Supply Tube (중앙 투입 형식의 나노급 입자 원심분리기 제작에 관한 연구)

  • Hwang, Gyo-Seon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.4
    • /
    • pp.576-581
    • /
    • 2010
  • As a super high speed small-sized centrifugal separator which is operated by the center inputting method has solved two difficulty problems, it can be made use of developing the new composition through the making of Nano particle (50~100nm) by high speed revolution and alleviation of unbalanced shapes inside the disk continuously throwing slurry in the central part. Uses the air spindle and the centrifugal machine production will be able to manufacture the Roh class fine particle under boil.

Studies on Flavonoid Glycoside of the leaves of Viola diamantica (금강제비꽃 잎의 Flavonoid 배당체(II))

  • Yook, Chang-Soo;Lee, Woo-Tchul;Moon, Chang-Kiu
    • YAKHAK HOEJI
    • /
    • v.33 no.2
    • /
    • pp.124-128
    • /
    • 1989
  • The drug consists of the dried entire plant of Viola diamantica (family Violaceae). It is used for the treatment of acute pyogenic diseases such as boil and carbuncles; also as tumor, high fever, tuberculosis and astringent hemostatic. Two flavonol glycosides have been isolated from the aerial parts of Viola diamantica and could be identifed as kaempferol 7-rhamnoside and kaempferol 3,7-dirhamnoside (bright yellow needle crystal, mp $225^{\circ}$, $C_{27}\;H_{30}\;O_4\;4H_2O$). Kaempferol 7-rhamnoside and kaempferol 3,7-dirhamnoside were first isolated from Viola diamantica.

  • PDF

Thermal Design and Heat Load Measurement of PSICS (적외선 우주망원경 냉각시스템 열설계 및 열침입량 측정)

  • Yang H. S.;Kim D. L.;Lee B. S.;Choi Y. S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.43-46
    • /
    • 2005
  • A Protomodel Space Infrared Cryogenic System (PSICS) cooled by a stirling cryocooler was designed. The PSICS has an IR sensor inside a cold box which is cooled by a stilting cryocooler with refrigeration capacity of 500mw at 80K in a vacuum vessel. It is important to minimize heat load for reducing background thermal noise. In order to design the cryogenic system of low heat load and to reduce heat load, we did several numerical analyses and tested using boil-off calorimetry with liquid nitrogen to measure the heat leak of the system. In this paper, we present the results obtained by thermal analysis and heat load measurement for designing the PSICS.

Optimal Process Design of Onboard BOG Re-liquefaction System for LNG Carrier (LNG 운반선을 위한 BOG 재액화시스템 최적 설계)

  • Hwang, Chulmin;Lim, Youngsub
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.372-379
    • /
    • 2018
  • High-pressure gas injection engines (HPGI) took center stage in LNG carrier propulsion systems after their advent. The HPGI engine system can be easily modified to include a re-liquefaction system by adding several devices, which can significantly increase the economic feasibility of the total system. This paper suggests the optimal operating conditions and capacity for a re-liquefaction system for an LNG carrier, which can minimize increases in the total annualized cost. The installation of a re-liquefaction system can save 0.23 million USD per year when the cost of LNG is 5 USD/Mscf. A sensitivity analysis with different LNG costs showed that the re-liquefaction system is profitable when the LNG cost is higher than 3.5 USD/Mscf.

Nitric Oxide Production Inhibitory and Anti-Oxidative Activities of Phenolic Compounds from the Barks of Ulmus davidiana

  • Lee, Jae-Hee;Yeom, Seung-Hwan;Kim, Min-Kee;Kim, Hyun-Jung;Sim, Jae-Geul;Lee, Min-Won
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.196.2-196.2
    • /
    • 2003
  • The Barks of Ulmus davidiana (Ulmaceae) have been used for the treatment of insecticide, anti-boil and anti-fungi in Korean traditional medicine. Four phenolic compounds were isolated from 80% Acetone extracts. The structures of these compounds were elucidated as (+)-catechin, (+)-catechin 7-O-${\beta}$-D-glucopyranoside, (+)-catechin 7-O-${\beta}$-D-xylopyranoside and procyanidin B-1. These phenolic compounds showed significant nitrogen monoxide(NO) production inhibitory activity in IFN-${\gamma}$, LPS stimulated RAW 264.7 cell and also showed significant antioxidative activity on DPPH radical. (omitted)

  • PDF