• 제목/요약/키워드: body temperature measuring

검색결과 145건 처리시간 0.026초

홀로그램 광학계의 초점영역을 이용한 투명 물체의 형상 측정에 관한 연구 (A Study on Measuring the Shape of Transparent Objects using the Focal Area of Hologram Optical System)

  • 변종환;유영기;오춘석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.600-602
    • /
    • 2005
  • Recently image display devices have become large and high quality. To control the qualities of the component, measurements of the shape and thickness of a plate glass has been required. In order to measure the shape of the specular objects, Non-Contact Optical Sensor using Hologram laser unit was proposed. The sensor has a optical system that is composed of a Hologram laser and objective lens used for CD Player, and the sensor showed high performance for measuring the shape and thickness of transparent plates. In the sensor, the temperature of the sensor body is controlled by TEC(Thermoelectric Cooler). In this paper, we proposed the measuring method to make better performance of sensor using focus error signal of a hologram laser unit. It can measure the shape and the thickness of transparent objects with the s-type focus error signal which is generated by the sensor while it goes to the object.

  • PDF

무선센서네트워크 기반의 u-헬스케어 모니터링 및 계측시스템 (Ubiquitous Healthcare Monitoring and Measuring System based on Wireless Sensor Network)

  • 이영동;이대석;;;정완영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.821-822
    • /
    • 2006
  • Ubiquitous healthcare monitoring and measuring system based on wireless sensor network was implemented and tested. The system can measure the ECG and body temperature of patients or elderly persons and transfer the data wirelessly in ad-hoc network to remote base-station connected to doctor's PDA/PC or hospital server, using wireless sensor motes. The data obtained can be analyzed by doctors and care providers to monitor a health status of patient in real time environment. To prove the capabilities of the wireless sensor network platform for ubiquitous healthcare applications, the performance of our monitoring and measuring system was tested with positive results.

  • PDF

군락상태에 있는 초본식물의 엽온의 일조변화 (On the Diurnal Change of Leaf Temperature of Herbaceous Plants in Plant Community)

  • 임양재
    • Journal of Plant Biology
    • /
    • 제17권3호
    • /
    • pp.107-112
    • /
    • 1974
  • Leaf temperature is complicated with the microclimate and the dry matter production in a plant community. But a daily change of leaf temperature varying by the locality in plant body or plant community is not yet clear. To resolve such a question, following experiment was designed; Helianthus tuberosus L., Glycine max L., Zea mays L., Impomoea batatas Lam., and Cucurbita moschata var. toonas Makino were planted in the different sandy loam, $2m{\times}2m-quadrat$, which has a eastern, southern, western and northern edge. In each plot 17-25 plants were planted and the distances between individuals spaced uniformly. And leaf temperature were measured by MR3-C type thermistor from 14th May through 20th August. It is seems that the upper leaf is affected by solar radiation, the lower leaf by released heat from the earth and the middle leaf by the conditions of both zones. Measuring the temperature of a leaf that is on terminal, central, left and right margins and base part, temperature of control plant in a leaf was sloped during about two hours from noon. It is noticeable as a "noon sleeping" phenomenon.henomenon.

  • PDF

Infrared Imaging for Screening Breast Cancer Metastasis Based on Abnormal Temperature Distribution

  • Ovechkin Aleck M.;Yoon Gilwon
    • Journal of the Optical Society of Korea
    • /
    • 제9권4호
    • /
    • pp.157-161
    • /
    • 2005
  • Medical infrared imaging is obtained by measuring the self-emitted infrared radiance from the human body. Infrared emission is related to surface temperature and temperature is one of the most important physiological parameters related to health. Though recent applications such as security identification and oriental medicine have provided new fields of biomedical applications, infrared thermography has had ups and downs in its usages in cancer detection. Some of the main difficulties include finding proper applications and efficient diagnostic algorithms. In this study, infrared thermal imaging was used to detect regional metastasis of breast cancer. Our measurements were done for 110 women. From 63 individuals of a Healthy Group and a Benign Breast Disease Group, we developed algorithms for differentiating malignant regional metastasis based on temperature difference and asymmetry of temperature distribution. Testing with 47 cancer patients, we achieved a positive predictive value of $87.5\%$ and a negative predictive value of $95.6\%$. The results were better than for mammogram examination. A proper analysis of infrared imaging proved to be a highly informative and sensitive method for differentiating regional cancer metastasis from normal regions.

정전 용량을 이용한 비접촉식 엘리베이터 버튼 (The contactless elevator button using the electrostatic capacity)

  • 방걸원
    • 산업융합연구
    • /
    • 제19권6호
    • /
    • pp.67-72
    • /
    • 2021
  • 건물에 설치된 엘리베이터는 승강기 호출 버튼과 목적층으로의 선택을 위한 입력 버튼으로 구성되어 있다. 엘리베이터 버튼은 승강기를 이용하는 사람이 직접 눌러야 입력이 된다. 이러한 승객의 입력은 버튼의 오염으로 인해 전염병에 감염될 수 있다. 이러한 문제점을 해결하기 위한 수단으로 비접촉식 버튼이 요구되고, 이는 정전용량 방식을 적용하여 물체의 근접을 감지한다. 적외선 열감지 센서를 부착하여 인체의 체온을 측정하는 기능을 구현하고 UV-LED를 부착하여 버튼의 살균 기능을 제공한다. 물체가 없을 때의 출력파형을 측정하고 물체가 근접할 때의 출력 파형을 측정하여 버튼이 선택되고 적외선온도측정 센서를 통해 체온이 측정되며, 사용자가 없을 때 UV-LED를 점등하여 살균하였다. 비접촉식 엘리베이터 버튼은 전염병을 옮기는 바이러스의 감염을 방지할 수 있는 효과가 있고, 체온을 감지하여 CIVID 19의 양성 확진자를 선별할 수 있어 감염병 예방에도 효과가 있을 것으로 기대된다.

열적외선 영상분석을 이용한 기능성 스포츠 팬티 개발 (Developing of Functional Sport Underpants using Infrared Thermal Image Analysis)

  • 이중숙;양정옥;이범진
    • 한국운동역학회지
    • /
    • 제25권2호
    • /
    • pp.231-240
    • /
    • 2015
  • Objective : This study is for providing data about men's functional sport underpants. It provides the fundamental data of biomechanics by measuring and analyzing the functionality of various underpants using infrared thermal image camera. Method : Then author drew a conclusion based on the final analysis of 965 questionnaire survey results about issues on men's functional sport underpants after discarding invalid questionnaires, as following. Change in body temperature while wearing functional underpants compared to general briefs or boxer pants showed lower temperature by approximately 1~2 degrees Celsius. In the case of general underpants, wearer sweats and feels hotter due to the friction of penis, scrotum and thigh. However functional sport functional underpants improved this issue with ergonomic 3D design by putting penis towards the lower part of the abdomen(below the navel) while putting the scrotum comfortably on the testicles, which enables to make room between the penis, scrotum and thigh of a wearer. Results : This was analyzed to lower the temperature of penis and scrotum. The survey results about the quality of functional underpants showed that 78% of the respondents felt comfortable while driving; 68.5% replied that frictional heat decreased while working out; 78.7% felt less sweat and humidity; 81.7% replied as highly wearable and comfortable; 77.1% replied functional sport underpants were the most comfortable in routine lives or in workout times. Putting all such results together, it is possible to conclude that functional sport is an excellent product. Conclusion : This can be evaluated as an excellent functional sport underpants, towards the penis abdomen (under the navel) in 3D human engineering design, by the scrotum to wearing to be easier to scrotum of pocket, the penis and scrotum and thighs were separated and analyzed with a function that will lower the body temperature of the penis and scrotum.

산화물 환원공정에 의해 제조된 Bi2Te2.7Se0.3 분말의 열전특성 (Thermoelectric Properties of Bi2Te2.7Se0.3 Powder Synthesized by an Oxide-Reduction Process)

  • 박배건;이길근;김우열;하국현
    • 한국분말재료학회지
    • /
    • 제18권5호
    • /
    • pp.437-442
    • /
    • 2011
  • The present study focused on the synthesis of Bi-Te-Se-based powder by an oxide-reduction process, and analysis of the thermoelectric properties of the synthesized powder. The phase structure, chemical composition, and morphology of the synthesized powder were analyzed by XRD, EPMA and SEM. The synthesized powder was sintered by spark plasma sintering. The thermoelectric properties of the sintered body were evaluated by measuring its Seebeck coefficient, electrical resistivity, and thermal conductivity. $Bi_2Te_{2.7}Se_{0.3}$ powder was synthesized from a mixture of $Bi_2O_3$, $TeO_2$, and $SeO_2$ powders by mechanical milling, calcination, and reduction. The sintered body of the synthesized powder exhibited n-type thermoelectric characteristics. The thermoelectric properties of the sintered bodies depend on the reduction temperature. The Seebeck coefficient and electrical resistivity of the sintered body were increased with increasing reduction temperature. The sintered body of the $Bi_2Te_{2.7}Se_{0.3}$ powder synthesized at $360^{\circ}C$ showed about 0.5 of the figure of merit (ZT) at room temperature.

The Analysis of Variation on the Area of Shoes with EMG and Thermography of Lower Extremity

  • Lee, Cu-Rie;Kim, Keun-Jo;Lee, Jin
    • 대한물리치료과학회지
    • /
    • 제24권3호
    • /
    • pp.30-38
    • /
    • 2017
  • Purpose: The purpose of this study was to find out changes in muscle activity and body heat of tibialis anterior and gastrocnemius muscles according to the area touching the ground through the areas of different heel heights using electromyography and infrared thermography. Method: This study was carried out for 15 healthy women. After walking for 30 minutes, the body temperature was measured in a standing state in front of the measuring instrument, and the distance between the treadmill and the thermography was about 50M, which may cause an error in measurement. Result: The results of the comparison of changes in muscle activity and body heat showed significant differences all in tibialis anterior, medial gastrocnemius muscle an lateral gastrocnemius muscle. The changes in body heat of tibialis anterior and medial gastrocnemius muscles according to the shape of the heel were lower as the area of the heel touching the ground was wider. Conclusion: This study was conducted to find out changes in muscle activity and body heat of tibialis anterior and gastrocnemius muscle depending on the area touching the ground through different heel areas.

농약방제복 개발에 관한 연구 (A Study on the Comfortable Pesticide-Proof Clothes)

  • 최정화;김현식;정영옥
    • 한국의류학회지
    • /
    • 제11권2호
    • /
    • pp.91-100
    • /
    • 1987
  • To develop the comfortable pesticid-proof clothes, wearing trials for 7 types of existing pesticide-proof clothes were done measuring skin temperature, pulse rate, humidity and temperature of inside clothing and subjective feeling such as thermal, humid and comfort sensations at $28{\pm}1^{\circ}C$, $75{\pm}5\%$ RH, 2.3 m/sec wind speed. (Experiment 1). On the base of above results, wearing trials of 6 types of new pesticide-proof clothes and 3 types of pesticide-proof clothes as control group were done with the same method as experiment 1. (Experiment 2). The results obtained were as follows 1. Heat stress was lower in newly designed pesticide-proof clothes with mesh running shirts. 2. For the body temperature regulation, it was confirmed that 6 types of new pesticide-proof clothes made of microporous fabric were better than the others.

  • PDF

평판 투명 물체의 형상측정을 위한 비접촉식 광센서 개발 (Development of a noncontact optical sensor for measuring the shape of transparent plates)

  • 윤상필;유영기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.214-214
    • /
    • 2000
  • This paper deals with the non contact optical sensor to measure the shape of transparent plates such as glass panel of LCD(Liquid Crystal Display). The conventional methods to obtain the shape or thickness of a transparent plates are contact type sensor such as LVOT(Linear Variable Differential Transformer). Due to the contact between the tip of the sensor and the surface of objects, the tip is abraded. In addition, the high temperature glass casting makes the size of sensor body changed. These reasons makes the sensor degraded. In this paper, to overcome these problem, we proposed a low cost noncontact optical sensor this is composed of the Hologram laser unit of a CD-Pickup and a plastic lens. To evaluate the performance of the proposed optical sensor, a series of experiments were performed for various measurement condition. Based upon observation of the experimental result, the developed sensor shows good result for measuring the shape of transparent plates.

  • PDF