• Title/Summary/Keyword: body surface change

Search Result 295, Processing Time 0.028 seconds

Effect of Deoxynivalenol on Immunoglobulin in the Mouse (Mouse에서의 Deoxynivalenol이 면역글로브린에 미치는 영향)

  • 이국천;이주홍;손성기;주영국
    • Korean Journal of Veterinary Service
    • /
    • v.15 no.2
    • /
    • pp.166-173
    • /
    • 1992
  • Mice were fed semi-purified diets containing 0, 2, 10 and 25 ppm(mg/kg) deoxynivalenol over 8 weeks and were assessed for effects on bodyweight gain, serum immunolglobulin levels and surface immunoglobulin bearing lymphocyte ratio. 1. The rate of body-weight gain was significantly reduced (p<0.05) at the 10 and 25 ppm of DON, whereas the mice ingesting the diet containing 2 ppm DON was not. 2. IgA in serum immunolglobulin was significantly increased (P<0.05) at the 10 and 25 ppm of DON, but IgG, IgM were decreased, whereas exposure to 2 ppm DON was not change. 3. Concentration of IgA from Peyer's patch of mice fed DON exhibited increased at 10, 25 ppm. 4. Lymphocytes surface marker studies revealed that IgA, IgG and IgM were 2.2%, 0.4% and 1.5% respectively. These results suggest that dietary exposure to DON alters regulation of IgA production

  • PDF

The Relationship between Clothing Microclimate and Physiological Responses at $15^{\circ}C$ Environment ($15^{\circ}C$ 환경에서 의복기후와 인체생리반응과의 관련성)

  • Park, Joon-Hee;Choi, Jeong-Wha
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.4
    • /
    • pp.97-105
    • /
    • 2008
  • The objective of this study is to investigate the relationship between clothing microclimate and physiological responses, including subjective sensations, when, in a $15^{\circ}C$ environment, a range of temperatures inside clothing is broadly produced from using various combinations of upper and lower garments. Six male subjects participated in the investigation and the results were as follows. For all types of inside garments, the temperature of the clothing was lower than the skin temperature for the whole body in each case. The mean temperature for inside clothing ($\bar{T}_{cl}$) significantly showed the highest correlation with mean weighted skin temperature (r = 0.816) and was less positively correlated with the temperature of the inside clothing at the chest (r = 0.326) (p < .01). Values for both the energy expenditure and the heart rate were less positively correlated with the clothing microclimate (p < .01). The change of body heat content showed a negative correlation with the surface temperature of the innermost clothing (r = -0.519) and there was a difference between the innermost surface temperature and the outermost surface temperature of the clothing at the chest (r = -0.577). As td increased, the increase of body heat content declined (p < .01). There was a negative correlation between body fat and some of the temperatures inside the clothing (p < .01) and body fat had no significant correlation with the humidity inside the clothing. Subjective sensations were more highly correlated with $\bar{T}_{cl}$ than with the temperature of the inside clothing at the chest and had not significantly correlation with the humidity of the inside clothing. In conclusion, through these results, it can be seen that the temperature inside the clothing was related to various physiological responses and subjective sensations, and that the mean temperature of the inside clothing ($\bar{T}_{cl}$) showed a higher relationship with the temperature of the inside clothing at the abdomen than that at the chest.

A Comparative Analysis of the Lower Body Trunk for Men's Slacks Pattern Design according to by Age-groups - Focused on Ningbo City, Zhejiang Province - (중국 남성의 슬랙스 패턴설계를 위한 연령층별 하반신 체간부 비교 분석 - 절강성 영파 지역을 중심으로 -)

  • Suh, Chu-Yeon;Lee, So-Young;Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.13 no.4
    • /
    • pp.124-136
    • /
    • 2009
  • This study was focused on classifying lower-body trunk and revealing the lower-body characteristics of the Chinese males in their 20s through 40s for their slacks pattern design. Compared with the 20s, the subjects in their 30s and 40s had small vertical and big horizontal sizes and showed a somatotype difference through a horizontal change. According to the size of absolute values, the lower body of Chinese men was "tall and normal trunk"(43.9%). Based on the shape of index values, Type 3(40.3%) was representative with average hip-surface length, waist-hip width difference and long upper hip. While Type 3 was seen a lot in the 20s(51.8%), 30s and 40s were each represented by Type 2(47.1%) with the smallest waist-hip width difference, average upper hip, and long hip-surface length and Type 1(45.9%) with small waist-hip width difference, average upper hip, and short hip-surface length. As this study is confined to Ningbo City of Zhejiang Province and has a small number of subjects, the generalization of the findings should be more serious. Further research will be centered on the development of slacks patterns in consideration of the body type changes.

Effect of Specific urface Area on the Gas Sensitive Properties (${\gamma}$-$Fe_2O_3$ 세라믹 가스감지소자;비표면이 가스감응성에 미치는 영향)

  • 신장욱;박순자
    • Journal of the Korean Ceramic Society
    • /
    • v.23 no.5
    • /
    • pp.1-8
    • /
    • 1986
  • This paper is concerned with a gas sensor composed of semi-conducting ${\gamma}$-$Fe_2O_3$ ceramics made by oxidizing $Fe_2O_3$ sintered body. Acicular $\alpha$-FeOOH powder prepared by precipitation of $FeSO_4$.$7H_2O$ solution was transformed to $FeSO_4$ sintered at 700$^{\circ}$-850$^{\circ}$C for 1 hr. and then oxidized to ${\gamma}$-$Fe_2O_3$ The gas sensitive properties of ${\gamma}$-$Fe_2O_3$ ceramic bodies based on the lectrical resistance change was measured in 0.5-2 vol% $H_2$ and $C_2$ $H_2$ gas at 35$0^{\circ}C$ The specific surface area of sintered specimen largely dependent on the sintering temperature and grain shape directly affected the gas sensitive pro-perties of ${\gamma}$-$Fe_2O_3$gas sensor. Specimens having larger specific surface area showed better sensitivity which means the electrical resistance change due to oxidation and reduction process occurs on ly at the surface of grains microscopically in the ${\gamma}$-$Fe_2O_3$ceramics. Micropores made in $Fe_2O_3$ powder during dehydration of $\alpha$-FeOOH can not prompt the gas sensitive properties of sintered ${\gamma}$-$Fe_2O_3$ because they are sintered or closed in the grains during sintering process and dose not affect the specific surface area of sintered body.

  • PDF

Thermo-sensitive Clothing Development by Consumer Investigation and Wearing Test (소비자 조사와 착의 실험을 통한 온도감응형 기능성 의류개발을 위한 기초연구)

  • Sang, Jeong-Seon;Chung, Kyunghwa;Park, Juhyun;Oh, Kyung Wha
    • Fashion & Textile Research Journal
    • /
    • v.19 no.1
    • /
    • pp.90-100
    • /
    • 2017
  • In this research, consumer awareness investigation and wearing test were carried out for obtaining useful data on the development of thermo-sensitive functional clothing material. A survey involved 216 people in Seoul and Kyeonggi-do, and 200 questionnaires data were analyzed by descriptive statistics and frequency using SPSS 17.0. Four healthy men in twenties were participated for wearing test. Subjects in normal loungewear were exposed to temperature change from the initial temperature $30^{\circ}C$ down to $5^{\circ}C$ for an hour in a climate chamber. The environmental temperature, surface temperature of garment and skin were measured. As a result, most of respondents have all season clothing products such as underwear, hosiery, and jogging suit for loungewear. Also, thermo regulator y functional clothes are frequently used as underwear and sweat shirt. The consumer awareness investigation on thermo regulatory functional clothing showed that the most important key buying factor is quick climate temperature response, easy maintenance, design and cost, in that order. Surface temperature of garment went down with the cooling down of environmental temperature. The lower environmental temperature, the greater temperature difference by body part showed. Skin temperature change by environmental temperature showed similar tendency of garment surface temperature. In comparison between garment surface and body skin, temperature difference became larger under the lower environmental temperature.

Quantitative Monitoring of Body Pressure Distribution Using Built-in Optical Sensors

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Seo, Jihyeon;Lee, Byunghun;Lee, Dongkyu;Kwon, Ohwon
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.279-282
    • /
    • 2020
  • In this study, body pressure was quantitatively detected using built-in optical sensors, inside an air cushion seat. The proposed system visualizes the effect of the body pressure distribution on the air cushion seat. The built-in sensor is based on the time-of-flight (ToF) optical method, instead of the conventional electrical sensor. A ToF optical sensors is attached to the bottom surface of the air-filled cells in the air cushion. Therefore, ToF sensors are durable, as they do not come in physical contact with the body even after repeated use. A ToF sensor indirectly expresses the body pressure by measuring the change in the height of the air-filled cell, after being subjected to the weight of the body. An array of such sensors can measure the body pressure distribution when the user sits on the air cushion seat. We implemented a prototype of the air cushion seat equipped with 7 ToF optical sensors and investigated its characteristics. In this experiment, the ToF optical pressure sensor successfully identified the pressure distribution corresponding to a sitting position. The data were accessed through a mobile device.

Clinical expeerience of funnel chest corrected by ravitch method -5 cases report- (Ravitch 술식으로 교정한 누두흉 치험 5예)

  • 정황규
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.699-706
    • /
    • 1986
  • We have experienced 5 cases of Pectus excavatum corrected by Ravitch method without use of K-wire or metal bar from Jan. 1985 to Apr. 1986. All cases were male. The symmetric depression was in 4 cases, asymmetric one was in one case. The chief complaints were dyspnea on exertion, frequent U.R.I. and inferiority. The flail chest was developed in all cases, but it was insignificant in all cases except one who needed assist ventilation. Mediastinitis was developed in one case one week postoperatively but well managed with drainage. A distance from the posterior surface of sternum to the anterior surface of vertebral body was estimated preoperatively and postoperatively. Postoperative result was evaluated as the change of distance postoperatively. The change was 1.5cm minimally to 3.5cm maximally. Late results were "Excellent" in 3 cases and "Good" in 2 cases.uot; in 2 cases.

  • PDF

Variation of Human Thermal Radiation Characteristics Applying Different Clothing Materials (의복 소재 변경에 따른 인체 열상신호 변화 특성)

  • Chang, Injoong;Bae, Ji-Yeul;Lee, Namkyu;Kwak, Hwykuen;Cho, Hyung Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.644-653
    • /
    • 2019
  • With the development of themal observatory device(TOD), thermal camouflage system has been applied not only to the weapon system but also to the combat suit for soldiers. In this paper, the characteristic of thermal radiation of human body depending on the clothing material properties was analyzed through numerical simulations. The bioheat equation with thermoregulatory model was solved to obtain the realistic surface temperature of human body and these results are combined with the emissivity of human skin and clothing in order to calculate the thermal signature from the human body. According to each thermal resistance of clothing, the optimal background radiance which makes contrast radiance intensity(CRI) be lowest is different. Also, the average CRI variation per thermal resistance change is about twice as much as the case of evaporative resistance change.

The Basic Studies of Thermal Physiology for Summer Wears (하복의 온열생리학적 기초연구)

  • Sung Su Kwang;Jeong Hyun Ok
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.9 no.2
    • /
    • pp.57-65
    • /
    • 1985
  • In the experiment with a basic material for the design of summer wear that comfort can be obtained in temperature, to get individual differences, clothing styles (slacks, skirt), material differences(T/C, cotton), and the contrast between when naked and dressed, when two healthy females were dressed four kinds of summer wear as an object of experiment under the regular warm temperature environmental condition (24, 28, 32, $36^{\circ}C$, $60\pm10\%$ RH), the measurement of physiological, phychological change was taken and the result goes as follow; 1. Mean skin temperature rose by clothing, body weight loss decreased below $32^{\circ}C$, thermal sensation changed toward low temperature by $2\~3^{\circ}C$. 2. Mean skin temperature, body weight loss, the lowest blood pressure above $32^{\circ}C$, under-clothing temperature, and thermal sensation increased when in slacks to be compared with when in skirt. 3. Ambient temperature had a great effect on mean skin temperature, body weight loss, respiration, clothing surface temperature, under-clothing temperature and humidity, thermal sensation, etc. 4. It was admitted that pulse, thermal sensation, comfort show different individuality. 5. It was recognized that the lowest blood pressure, clothing surface temperature, under. clothing humidity differ according to the kinds of clothing. 6. A comfortable ambient temperature in clothing summer wear was about $27\~28^{\circ}C$.

  • PDF

Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta (위상대조도 MRI에서 숙임각에 따른 상행대동맥의 혈류 측정)

  • Kim, Moon Sun;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.142-148
    • /
    • 2016
  • To evaluate the effect of flip angle on flow rate measurements obtained with phase contrast MRI according to the flip angle degree in ascending aorta and velocity encoding (VENC) was (150 m/s). 1.5T MRI in patients 17 (female: 8, male: 9, mean age $57.9{\pm}15.4$) as a target by applying a non-breath holding techniques to flip angle VENC (150 cm/s) in each of the ascending aorta was measured by changing $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$. Blood was obtained a peak velocity, average velocity, net forward volume, net forward volume/body surface area. Ascending aorta from average velocity (AV) measured the average value of the flip angle $20^{\circ}$ (9.87 cm/s), $30^{\circ}$ (9.6 cm/s) and $40^{\circ}$ (10.05 cm/s). Blood flow VENC in was blood flow change in flip angle change was high most blood flow measurement when the flip angle $30^{\circ}$ in VENC, crouching each blood flow is also proportional to the increases in the $20^{\circ}$ to $40^{\circ}$ and was increased, the deviation of the peak velocity and the average velocity is the smallest deviation from the flip angle $30^{\circ}$. Flip angle $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$ in peak velocity, average velocity, net forward volume, net forward volume/body surface area was no statistically significant difference (p > .05). Blood flow velocity and blood flow is measured by applying to adjust the flip angle accurately calculate the blood flow is important information for diagnosis and treatment of cardiovascular diseases, and can help in the examination on the blood flow measurement.