• 제목/요약/키워드: body movement monitoring

검색결과 37건 처리시간 0.023초

Wireless RF Sensor Structure for Non-Contact Vital Sign Monitoring

  • Kim, Sang-Gyu;Yun, Gi-Ho;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • 제12권1호
    • /
    • pp.37-44
    • /
    • 2012
  • This paper describes a compact and novel wireless vital sign sensor at 2.4 GHz that can detect heartbeat and respiration signals. The oscillator circuit incorporates a planar resonator, which functions as a series feedback element as well as a near-field radiator. The periodic movement of a human body during aerobic exercise could cause an input impedance variation of the radiator within near-field range. This variation results in a corresponding change in the oscillation frequency and this change has been utilized for the sensing of human vital signs. In addition, a surface acoustic wave (SAW) filter and power detector have been used to increase the system sensitivity and to transform the frequency variation into a voltage waveform. The experimental results show that the proposed sensor placed 20 mm away from a human body can detect the vital signs very accurately.

근골격계 안전관리를 위한 모니터링 기법에 관한 연구 및 시스템 구현 (A Study on the Monitoring Technique for Musculoskeletal Safety Management and Implementation of the System)

  • 신영주;주하영;양진홍
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권3호
    • /
    • pp.267-276
    • /
    • 2020
  • 제조업 근로자는 근무 환경에서 반복 작업에 의한 근골격계 질환의 위험에 쉽게 노출되어 있다. 이는 신체를 반복적으로 이용하는 직업 특성상의 문제에 기인한다. 하지만 현재 감시 및 예방을 위한 모니터링 시스템이 제공되지 않아 매년 위험에 대한 근로자의 노출도가 증가하고 있다. 본 논문에서는 IMU 센서를 사용한 웨어러블 장치 제작을 통해 실제 작업 환경에서의 이러한 문제를 해결하는 방법에 대해 제시한다. 웨어러블 형태의 장치를 착용 후, 근골격계 움직임에 따른 회전 값을 받아와 데이터 분석을 통해 사용자의 움직임을 판단해낸다. 이때, 바이어스 제거와 누적 오차를 제거해 정교한 데이터 취득하여 이를 동적 임곗값 형식으로 분석하여 사용자의 회전 운동 횟수를 측정해내어 위험도를 판단한다. 본 논문에서 제안한 웨어러블 장치를 이용 팔꿈치 근골격계 질환에 대한 회전 횟수를 측정하는 웹 페이지를 통해 본 방법의 효과를 확인할 수 있었다.

Simultaneous monitoring of motion ECG of two subjects using Bluetooth Piconet and baseline drift

  • Dave, Tejal;Pandya, Utpal
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.365-371
    • /
    • 2018
  • Uninterrupted monitoring of multiple subjects is required for mass causality events, in hospital environment or for sports by medical technicians or physicians. Movement of subjects under monitoring requires such system to be wireless, sometimes demands multiple transmitters and a receiver as a base station and monitored parameter must not be corrupted by any noise before further diagnosis. A Bluetooth Piconet network is visualized, where each subject carries a Bluetooth transmitter module that acquires vital sign continuously and relays to Bluetooth enabled device where, further signal processing is done. In this paper, a wireless network is realized to capture ECG of two subjects performing different activities like cycling, jogging, staircase climbing at 100 Hz frequency using prototyped Bluetooth module. The paper demonstrates removal of baseline drift using Fast Fourier Transform and Inverse Fast Fourier Transform and removal of high frequency noise using moving average and S-Golay algorithm. Experimental results highlight the efficacy of the proposed work to monitor any vital sign parameters of multiple subjects simultaneously. The importance of removing baseline drift before high frequency noise removal is shown using experimental results. It is possible to use Bluetooth Piconet frame work to capture ECG simultaneously for more than two subjects. For the applications where there will be larger body movement, baseline drift removal is a major concern and hence along with wireless transmission issues, baseline drift removal before high frequency noise removal is necessary for further feature extraction.

Implementation of Extended Kalman Filter for Real-Time Noncontact ECG Signal Acquisition in Android-Based Mobile Monitoring System

  • Rachim, Vega Pradana;Kang, Sung-Chul;Chung, Wan-Young;Kwon, Tae-Ha
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.7-14
    • /
    • 2014
  • Noncontact electrocardiogram (ECG) measurement using capacitive-coupled technique is a very reliable long-term noninvasive health-care remote monitoring system. It can be used continuously without interrupting the daily activities of the user and is one of the most promising developments in health-care technology. However, ECG signal is a very small electric signal. A robust system is needed to separate the clean ECG signal from noise in the measurement environment. Noise may come from many sources around the system, for example, bad contact between the sensor and body, common-mode electrical noise, movement artifacts, and triboelectric effect. Thus, in this paper, the extended Kalman filter (EKF) is applied to denoise a real-time ECG signal in capacitive-coupled sensors. The ECG signal becomes highly stable and noise-free by combining the common analog signal processing and the digital EKF in the processing step. Furthermore, to achieve ubiquitous monitoring, android-based application is developed to process the heart rate in a realtime ECG measurement.

신체 변화량을 이용한 웹 기반 비만관리 시스템 (A web-based Obesity Management system using Body variations)

  • 강희범;이종원;장재명;김경환;정회경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.722-724
    • /
    • 2016
  • 오늘날 비만인구가 증가함에 따라서 비만을 관리하고 모니터링하는 시스템 개발의 필요성이 증대되고 있다. 그러나 대부분의 모니터링 시스템은 사용자의 신장이나 체중의 정보만을 가지고 계산하여 보여주는 역할만 하기 때문에 사용자가 운동에 대한 계획을 설계할 시에 효율성이 낮은 문제점이 있었다. 본 논문에서는 사용자의 BMI의 수치를 그래프로 나타내고, BMR수치의 등급을 나누어 사용자가 자신에 대해 이해하기 쉽게 하였다. 또한 사용자가 사용한 운동기구의 사용한 회수와 일간 소모한 Kcal를 보여줌으로써 운동 계획을 설계하는데 효율적인 웹 기반 모니터링 시스템을 연구한다.

  • PDF

IR-UWB 레이더와 Lomb-Scargle Periodogram을 이용한 비접촉 심박 탐지 (Non-contact Heart Rate Monitoring using IR-UWB Radar and Lomb-Scargle Periodogram)

  • 변상선
    • 대한임베디드공학회논문지
    • /
    • 제17권1호
    • /
    • pp.25-32
    • /
    • 2022
  • IR-UWB radar has been regarded as the most promising technology for non-contact respiration and heartbeat monitoring because of its ability of detecting slight motion even in submillimeter range. Measuring heart rate is most challenging since the chest movement by heartbeat is quite subtle and easily interfered with by a random body motion or background noise. Additionally, periodic sampling can be limited by the performance of computer that handles the radar signals. In this paper, we deploy Lomb-Scargle periodogram method that estimates heart rate even with irregularly sampled data and uneven signal amplitude. Lomb-Scargle periodogram is known as a method for finding periodicity in irregularly-sampled and noisy data set. We also implement a motion detection scheme in order to make the heart rate estimation pause when a random motion is detected. Our scheme is implemented using Novelda's X4M03 radar development kit and its corresponding drivers and Python packages. Experimental results show that the estimation with Lomb-Scargle periodogram yield more accurate heart rate than the method of measuring peak-to-peak distance.

광섬유 브래그 격자 센서를 이용한 근육 상태 감시 시스템 (Muscular Condition Monitoring System Using Fiber Bragg Grating Sensors)

  • 김헌영;이진혁;김대현
    • 비파괴검사학회지
    • /
    • 제34권5호
    • /
    • pp.362-368
    • /
    • 2014
  • 광섬유센서는 전자파 무간섭, 부식 방지, 다중화 등의 장점들을 갖고 있어 다양한 상태 감시 시스템을 위한 연구에 많이 활용되고 있다. 본 논문에서는 광섬유센서 기반의 인체 근육 상태 감시 시스템을 제안한다. 상용화되어 있는 인체 상태 감시 센서는 전자기 기반의 센서가 대부분이다. 이는 전자기 간섭 및 왜곡의 우려가 있어, 이를 보완하고 장치의 간소화 및 사용자 편의성을 위해 광섬유 브래그 격자센서를 사용하였다. 근육 상태의 지표가 되는 근육 수축 및 이완을 측정하기 위해 원주방향으로의 운동 감시가 가능한 밴드형태의 광섬유 브래그 격자센서 모듈을 제작하였다. 그리고 광섬유 브래그 격자센서 모듈의 적용성 평가를 위해 단축 인장시험을 수행하였다. 실험 결과 인장 크기에 따른 브래그 파장 변화가 상호 연관성을 보였으며, 이를 통해 브래그 격자센서 기반의 근육 상태 감시 시스템 개발의 가능성을 확인하였다.

스마트 실버 헬스케어를 위한 비접촉 인체감지 IOT 센서 개발 (A Development of Non-Invasive Body Monitoring IOT Sensor for Smart Silver Healthcare)

  • 강병욱;김상희
    • 융합신호처리학회논문지
    • /
    • 제19권1호
    • /
    • pp.28-34
    • /
    • 2018
  • 본 논문은 적외선 온도센서를 이용한 재실인원 측정을 통한 출입자 관리 시스템, 방 내부의 움직임 파악하기 위한 PIR센서 모듈, 그리고 취침 상태를 판별하기 위한 스마트 호흡감지 모듈로 구성된다. 센싱부와 알고리즘 구동 부를 일체화 한 임베디드 형태의 센서 모듈과 통신 시스템으로 구성하였다. 고령화 사회가 가속화, 고급화됨에 따라 실버케어에 대한 사회적 비용이 증가하고 프라이버시를 보호하기 위해선 효율적인 실버케어기기 개발을 통하여 비용 감소가 필요하다. 제안된 비 영상 인체감지 IOT 센서 시스템은 하드웨어와 소프트웨어로 구현하였고 기존의 영상에 의한 감시 방법과 비교하여 우수한 성능을 확인하였다.

지렁이 움직임 감지 시스템을 이용한 중금속 오염 토양의 생태독성 발현 메커니즘에 대한 연구 (Study on the Mechanism of Manifestation of Ecological Toxicity in Heavy Metal Contaminated Soil Using the Sensing System of Earthworm Movement)

  • 이우춘;이상훈;전지훈;이상우;김순오
    • 자원환경지질
    • /
    • 제54권3호
    • /
    • pp.399-408
    • /
    • 2021
  • 배경토양에 카드뮴(Cd), 납(Pb), 아연(Zn) 등의 중금속 오염물질을 인위적으로 오염시킨 후 진동센서 등으로 구성된 시스템(ViSSET)을 이용하여 지렁이 움직임 특성을 실시간으로 모니터링하였다. 이로부터 얻어진 지렁이 움직임의 누적 횟수와 전통적인 지렁이 행태지표(실험 전후의 체중 변화, 생체축적농도) 등을 이용하여 중금속 오염물질의 토양 내 생태독성 발현 기작을 규명하였다. 중금속별 농도 증가에 따른 지렁이 움직임을 살펴보면, Cd는 농도가 증가함에 따라 지렁이 움직임은 감소하다가 증가하는 경향을 보였고, Pb는 농도 증가에 따라 지렁이 움직임이 급증하였으며, Zn의 경우는 농도가 증가함에 따라 지렁이 움직임은 지속적으로 감소하는 것으로 나타났다. 지렁이의 체중은 Zn 오염 토양에서 가장 크게 감소하였으며, Cd와 Pb에서는 지렁이 체중 변화가 유사한 것으로 조사되었다. 생물축적농도는 Cd, Zn, Pb의 순으로 높게 조사되었고, 특히 Pb의 경우에는 토양 내 농도에 따른 생체축적농도의 변화가 뚜렷하게 나타나지 않았다. Cd는 metallothionein-bound 형태로 결합되어 지렁이 생체 내에 장기간 축적되며, 특히 고농도에서는 임계효과(critical effect)에 의해 지렁이 움직임에 악영향을 주는 것으로 판단된다. Pb는 섭취에 의하여 생태독성이 발현되는 것이 아니고 피부를 자극시키거나 감각기관을 손상시킴으로서 독성을 발현시키는 것으로 생각된다. Zn은 소화기관의 세포막을 손상시키거나 물질대사를 과도하게 증가시킴으로써 지렁이 움직임과 체중이 감소하는 것과 같은 생태독성을 발현시킨다. 지렁이 움직임에 대한 실시간 모니터링 결과를 분석하여 도출한 Pb의 50% 최대 영향농도(half maximal effective concentration, EC50)는 751.2 mg/kg로 기존 연구와 유사한 것으로 나타났다. 본 연구를 통하여 기존에 이용되어온 지렁이 행태 지표와 새롭게 제시한 지렁이의 움직임을 실시간으로 모니터링하여 얻어진 결과를 통합적으로 해석함으로써 중금속 오염물질의 생태독성 발현 기작을 규명하는 것이 효과적임을 확인할 수 있었다.

신체자세 안정도의 정량분석에 관한 연구 (Quantitative analysis of body postural stability)

  • 차은종;김경아;이태수;이경무;김남균;김연희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.39-43
    • /
    • 1997
  • Posturography stands or quantitative assessment of body postural stability analysis. The present study developed a balance plate system to monitor patient's center of pressure (COP) movement and to analyze its stability. An equilateral triangular shaped plate was made of duralumin and forces were measured on the three vertices of the plate using industrial load cells. Specially designed electronic circuit picked up force signals ed into data acquisition system to calculate the cartesian coordinates of COP. COP calculation error was less than 2%. The force signals enabled to compute stability measures, which consisted of a variety of clinical parameters related to postural stability. Clinical experiments were carefully designed and performed on 40 normal subjects. The results were that 1) postural stability decreased with age and 2) the best parameters were those of posture deviation measures. A customized PC-based software package was developed to apply the present technique with a great convenience to monitoring and analyzing postural stability in an accurate and quantitative way.

  • PDF