• 제목/요약/키워드: body measurement

검색결과 2,438건 처리시간 0.033초

남자 고등학생의 드롭별 인체 특성에 관한 연구 (A Study on the Body Characteristics of High School Boys According to Their Drop Types)

  • 현은경;남윤자
    • 한국의류학회지
    • /
    • 제34권8호
    • /
    • pp.1233-1241
    • /
    • 2010
  • This study analyzes the body characteristics of high school boys according to 3 different body types in order to improve the fit of upper garments. First, among the lateral body types, the straight body type was selected from the SizeKorea 3D scanned data and 2D measurement data. Second, high school boys (classified as straight lateral body type) were grouped into type B, A, and Y drop groups. The percentages of type B, type A, type Y are 17.8%, 48.1%, 32.1% respectively. The characteristics of the body types were analyzed. While the bust circumference were the same among the three body types (chest width, back width, back across shoulder, and bust width did not show a significant difference); however, waist and hip measurements showed a significant difference among the three body types. Third, the height of the high school boys ranged between 165cm and 180cm and the bust circumference between 85cm and 97cm. For the bust size categories, type B and type Y are distributed similarly; however, type A is distributed in the smaller bust size categories.

남성 재킷 패턴 설계를 위한 30-44세 남성의 상반신 체형 및 유형별 사이즈 연구 (A study on the upper body type and size of men aged 30-44 for men jacket pattern design)

  • 권동국
    • 복식문화연구
    • /
    • 제29권6호
    • /
    • pp.881-903
    • /
    • 2021
  • This study aimed to analyze adult men's body sizes and shapes and suggest size specifications to provide preliminary data to academia and industries. A total of 814 adult men aged 30-44 were selected from the 7th Size Korea data, and 55 direct upper body measurement and calculation items were analyzed using SPSS 25.0. In individual Individual differences, thickness, circumference, and width were high, and height and length were low. Height above the waist base line and shoulder dimension decreased in early 40s age group, while height below the waist base line declined as age increased. In addition, buttocks shape changes were found in early 40s age group. According to factor analysis, 'upper body and upper-extremity horizontal size', 'torso height and upper extremity length', 'shoulder dimension', 'upper body length' and 'shoulder angle' were derived. Using clustering analysis, four different body types were classified: i) big abdomen with flat chest, ii) slender with big, raised shoulders, iii) dwarfish with small, droopy shoulders, and iv) obese with large shoulders. 'Slender with big, raised shoulders' was a typical body shape among men aged 30-44. In older participants, the 'big abdomen with flat chest' ratio was low, while 'obese with large shoulders' was more common. This study proposed size specifications by body type considering the above characteristics.

중국(中國) 성인여성(成人女性)의 Bodice원형 연구(硏究) - 북경(北京).상해지역(上海地域) 거주자(居住者)를 중심(中心)으로 - (A Study on the Basic Bodice Block for Adult Women in China - Focusing on Resident in Beijing and Sanghai -)

  • 손희순;위혜정
    • 패션비즈니스
    • /
    • 제7권4호
    • /
    • pp.129-141
    • /
    • 2003
  • The aim of this study was to improve the fitness of Korean made apparel products being exported to China by developed the standard bodice block for the standard body of chinese women. For study, 139 adult Chinese women(aged between 19 and 24) in Beijing and Shanghai were sampled to be measured for there body sizes. In order to develope the standard bodice block, 3 women was selected closely the standard body measurement and the fitting was tested. The results of this study were as follows. As compared with the means measurement of chinese women in Beijing and Shanghai, there were difference between the two. Especially, width, thickness, girth and hight items. The standard bodice block drafted and tested. It showed unfit problems. and were adjusted. The application measurements of standard body was selected. As based on item, it has finally developed the standard bodice block of tight-fitting shape.

IBS-2000보정기기를 이용한 체형측정방법에 따른 사상체질 진단정확률 비교연구 (Comparative Study of Sasang Constitutions Diagnostic Accuracy Rate on Measurement Method of Body Shape by IBS-2000 Compensator)

  • 설유경;이의주;김규곤;김종원
    • 사상체질의학회지
    • /
    • 제19권1호
    • /
    • pp.78-89
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method & Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated width 5 places and hand-operated circumference 8 places, Automatic width 5 places) and analyzed the anthropometric data dividing into sex, age, BMI. 1057 patients's data are used in the analysis. 3. Results and Conclusions 1) 5th Width variable which was measured during lying down was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement by Width which was measured during lying down and Width which IBS standing was 40-60%. 3) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

Research on Subcutaneous Pulse Shape Measurement by Near-infrared Moiré Technique

  • Chen, Ying-Yun;Liu, Zhizhen;Du, Jian;Chang, Rong-Seng
    • Journal of the Optical Society of Korea
    • /
    • 제19권2호
    • /
    • pp.123-129
    • /
    • 2015
  • A pulse is generated when the heart pumps blood into the arterial system. The heart pumps blood only when it contracts, not when it relaxes; therefore, blood enters the arterial system in a cyclical form. Artery beating is visible in some parts of the body surface, such as the radial artery of the wrist. This paper mainly uses the feature in which near-infrared spectroscopy penetrates skin to construct a non-invasive measurement system that can measure small vibration in the subcutaneous tissue of the human body, and then uses it for the pulse measurement. This measurement system uses the optical moir$\acute{e}$ principle, together with the fringe displacement made by small vibration in the subcutaneous tissue, and an image analysis program to calculate the height variation from small vibrations in the subcutaneous tissue. It completes a measurement system that records height variation with time, and that together with a fast Fourier transform (FFT) program, they can convert the pulse waveform generated by vibration (time-amplitude) to heartbeat frequency (frequency-amplitude). This is a new and non-invasive medical assistance system for measuring the pulse of the human body, with the advantages of being simple, fast, safe and objective.

Brassiere 착용조건에 따른 신체의 형태적, 생리적 변화에 관한 심리적 연구 (A Experimental Study on the Formal and Physiological Change of Body according to the Wearing-Brassiere Condition.)

  • 박영득
    • 대한가정학회지
    • /
    • 제29권1호
    • /
    • pp.27-35
    • /
    • 1991
  • This study was carried out to investigate the influence of the various physiological function caused by brassiere wearing. The four experimental methods used in this study are as follows. For example, the Roentgen photographing, Body measurement by Sliding Gauge, the measurement of the Electrocardiogram and Blood Pressure. The results of the Electrocardiogram and Blood Pressure. The results of the investigation were as follows: 1. In experimental change by Sliding Gauge and Body measurement, The bust point was rised in order AB1>B2. The width of right and left bust point was decreased in order of A>B1>B2. According to, The supplementary effect of brassiere wearing was excellent in B2. 2. In the change of various organs by Roentgen photographing, The width of the chest and size of the heart were decreased in regular order of A>B1>B2. The diaphragm and the others were not showed change. 3. In the experimental result by measurement of the electrocardiogram, The interval of heart palpitation was decreased in order A>B1>B2 and the pulse frequency was similar. 4. In the experimental result by the blood pressure measurement, A had the highest blood pressure and B2 had the lowest pressure in all variables.

  • PDF

Assessment of Gradient-based Digital Speckle Correlation Measurement Errors

  • Jian, Zhao;Dong, Zhao;Zhe, Zhang
    • Journal of the Optical Society of Korea
    • /
    • 제16권4호
    • /
    • pp.372-380
    • /
    • 2012
  • The optical method Digital Speckle Correlation Measurement (DSCM) has been extensively applied due its capability to measure the entire displacement field over a body surface. A formula of displacement measurement errors by the gradient-based DSCM method was derived. The errors were found to explicitly relate to the image grayscale errors consisting of sub-pixel interpolation algorithm errors, image noise, and subset deformation mismatch at each point of the subset. A power-law dependence of the standard deviation of displacement measurement errors on the subset size was established when the subset deformation was rigid body translation and random image noise was dominant and it was confirmed by both the numerical and experimental results. In a gradient-based algorithm the basic assumption is rigid body translation of the interrogated subsets, however, this is in contradiction to the real circumstances where strains exist. Numerical and experimental results also indicated that, subset shape function mismatch was dominant when the order of the assumed subset shape function was lower than that of the actual subset deformation field and the power-law dependence clearly broke down. The power-law relationship further leads to a simple criterion for choosing a suitable subset size, image quality, sub-pixel algorithm, and subset shape function for DSCM.

열감지인광온도계를 이용한 물에 잠긴 물체 표면 온도장의 비접촉식 측정에 관한 연구 (A Study on Non-contact Surface Temperature Field Measurement of a Body Immerged in Water Using Thermographic Phosphor Thermometry)

  • 박윤성;차이타오;김경천
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.61-68
    • /
    • 2020
  • Thermographic phosphor (TP) thermometry is a noncontact optical measurement method and has been applied in many fields such as combustion and heat transfer. However, due to the limitation of bonding technology and measurement method, most TP thermometry studies were conducted only on the air environment with water-soluble binders. In this paper, a temperature measurement technology in water using TP is proposed by coatings of manganese activated magnesium fluorogermanate (Mg4FGeO6:Mn4+, MFG) with Polydimethylsiloxane (PDMS). Four MFG-PDMS coatings with different thicknesses were prepared. The lifetime of MFG was not affected by the thickness of the coating as a result of the experiment and analysis of phosphor intensity using a photomultiplier tube. To measure the surface temperature field of an immerged body in water, a cylinder-type cartridge heater was coated with MFG doped PDMS. Transient surface temperature field was successfully measured even the initial temperature is higher than the boiling point of water.

신체부위별 측정변인에 따른 경신강지환16의 비만 개선효과 평가 (Clinical efficacy of Gyeongshingangjeehwan16 according to obeisty related to measurement variables.)

  • 정양삼;윤기현;최승배;윤미정;신순식
    • 대한한의학방제학회지
    • /
    • 제16권1호
    • /
    • pp.169-183
    • /
    • 2008
  • In this study, we measured body mass index, visceral fat ratio and 6 parts of body, neck circumference, circumference of upper arm, chest circumference, abdomen circumference, hip circumference, and thigh circumference by bioimpedence analysis system, after taking Gyeongshingangjeehwan16 (GGEx16) in five months except the first period before taking GGEx16 on 49 women who are obesity or high-level obesity. In order to examine the significance test for the effect of obesity improvement of GGEx16, we practices repeated measure ANOVA with values of measurement variables in 6 monthly times. As a result of all measurement variables, there were significant difference (P-value=0.001). Therefore, we can say that GGEx16 is effective about obesity improvement. As it dramatically decreased between second measure period and first measure period for all measure variables, we can see that there were the most effect of GGEx16 in the first time after taking GGEx16. It is known that a important measurement variable to have a effect for obesity improvement about two variable which are body mass index and visceral fat ratio is waist circumference through correlation analysis. The result of whether there are differences to effect of obesity improvement for GGEx16 around the climacteric, there were significant difference for the effect of obesity improvement for GGEx16 around the climacteric about all parts of body (P-value=0.001). There were also powerfully difference in effect of obesity improvement for GGEx16 around the climacteric about all parts of body (P-value=0.001). Especially, the climacteric before is more effective than the climacteric after in the aspect of the effect of GGEx16.

  • PDF

성별 및 연령에 따른 3차원 인체측정에 대한 태도 비교 (Gender and Age Differences in Attitude toward 3-D Body Scanning)

  • 박재경;최경미;남윤자;이유리
    • 한국의류학회지
    • /
    • 제32권8호
    • /
    • pp.1244-1254
    • /
    • 2008
  • The purpose of this research is to compare the people’s attitude toward 3-D body scanning by their gender and age in order to provide the application of 3-D body scanning data for new services or products. This study collected questionnaire data from 442 Korean females and 258 Korean males who participated in the 3-D body scanning. The result of this study were as follows: 1. Most people had good feelings for 3-D body scanning. Male respondents were more dissatisfied than female, and teenagers had higher dissatisfaction rate than other age groups for the measurement garment. 2. 80.5% of all respondents had the intention for re-measurement of 3-D body scanning. Male respondents and teenagers had low intention for re-measurement. 3. For the use of 3-D body scanning data, 79.6% said "yes" for making avatar, and 88.3% agreed with the custom made clothes. There was no difference between gender and age for this question. The results of the study will demonstrate how clothing retailers and marketers can use the 3-D body scanning data.