• 제목/요약/키워드: body current

검색결과 2,033건 처리시간 0.029초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

우주조약의 국제법적 의미에 관한 연구 (A Study on the Meaning of Outer Space Treaty in International Law)

  • 김한택
    • 항공우주정책ㆍ법학회지
    • /
    • 제28권2호
    • /
    • pp.223-258
    • /
    • 2013
  • 필자는 우주조약의 국제법적 의미에 관하여 첫째, 우주활동의 법원칙선언조항, 둘째, 세부조약으로 발전한 조항 그리고 마지막으로 우주조약의 보완사항에 관한 최근 동향으로 분류하여 설명하였다. 1963년 12월 13일 UN총회의 '우주법선언'을 반영한 우주조약은 그 세부조약으로 1968년 구조협정, 1972년 책임협약, 1975년 등록협약을 제정하였다. 2013년 5월 기준으로 102개국이 가입하고 27개국이 서명한 우주조약은 그야말로 우주법의 '마그나 카르타'(Magna Carta) 내지는 우주의 헌법이라고 불릴 정도로 우주법의 가장 기본이 되는 원칙을 담고 있고, 특히 달과 다른 천체를 포함한 우주를 비전유원칙인 '국제공역'(res extra commercium)으로 선언함으로서 우주에 대한 영유권 문제를 종식시켰다는 점에서 큰 의미를 찾을 수 있다. 우주조약이 제정된지 반세기가 되어가는 시점에서 우주조약에서 규정하고 있는 조항 중 우주활동은 모든 국가들의 이익을 위한다는 원칙(제1조), 외기권 우주의 자유로운 탐사와 이용(제1조), 전유화금지(제2조)와 타국의 권리존중(제9조)은 조약법은 물론 모든 국가들을 구속하는 국제관습법과 '강행규범'(jus cogens)으로까지 발전된 조항이라고 할 수 있다. 특히 우주조약은 투명성과 개방성을 규범적으로 요구하고 있다. 이것은 우주활동이 '전세계적 공공 이익'(global public interest)과 관련되어 있음을 시사하고 있다. 이러한 우주에서의 '전세계적 공공이익'에 대한 원리는 국제공동체에게 '대세적 의무'(obligation erga omnes)를 부과하고 있는데, 우주를 모든 인류의 영역이라고 선언한 점, 우주에서의 협력의 의무, 우주비행사를 인류의 사절이라고 한 점, 우주활동에서 해로운 오염을 피하라고 한 점, 우주활동을 국가, 사적 실체 그리고 정부간 조직체(IGOs)로 제한한 점, 우주활동으로 인한 손해배상에 대한 절대책임원칙, 우주에서의 핵무기 및 대량파괴무기 배치 금지, 우주활동의 공개성과 투명성 그리고 국제우주제도의 보편적 적용 등이 이를 뒷받침 해주고 있다. 현재 우주조약의 해석을 두고 많은 논란이 있는 조항들이 있고 제정당시 예상 못했던 우주기술의 발달과 상업화로 인해 보충해야 할 주제도 많이 생겨나서 현재 COPUOS 내에서 1979년 달조약을 포함한 현행 우주관련 5개 조약의 지위검토를 법률소위원회에 의제로 포함시킬 것을 제의하여 1998년 제37차 법률소위원회부터 정식으로 승인받아 현재까지 논의되고 있다. 그러나 필자는 '우주법선언'의 내용들이 이미 국제관습법으로 굳어 졌으며, 이를 거의 반영한 우주조약의 상당부분 조항들이 이제는 국제관습법화 되었고, 심지어는 강행규범(jus cogens)이 된 조항들도 있다는 면에서 우주조약의 성과는 국제법상 매우 큰 의미를 지녔다고 평가하고 싶다. 앞으로 우주조약 이외에 우주관련세부조약들로도 해결하지 못하는 분야들은 COPUOS나 UN을 통하여 보완적인 결의와 선언들로 계속 반영되어야 할 것이며 만일 별도의 조약제정이 불가능하다면 적당한 시기에 우주조약을 포함하여 세부조약의 개정을 통하여 또는 추가의정서를 만들어 보완하면 좋을 것이라고 생각한다. 우주조약은 그 개념들의 모호성 때문에 수많은 학자들로부터 비난을 받아왔지만 그럼에도 불구하고 계속 존속해 왔다는 사실을 간과해서는 안 될 것이다. 현재 우주폐기물과 관련하여 "IADC 우주폐기물 경감 가이드라인", COPUOS의 "우주폐기물감축 가이드라인", 세계국제법협회(ILA)의 "우주폐기물로 인한 피해로부터 환경을 보호하기 위한 국제협약 초안" 등이 우주조약을 보완하고 있고, 분쟁해결에 관하여 세계국제법협회(ILA)가 1998년 타이페이(Taipei) 회의에서 채택한 "우주법분쟁해결에 관한 협약안"을 제시한 바 있고, 2011년 중재재판소(PCA)가 "우주활동관련 분쟁의 중재재판에 관한 선택규칙"을 제정하고, 2012년 우주활동관련 분쟁의 중재재판관을 새롭게 임명하였다는 점은 우주법이 계속 발전되어 가고 있다는 모습을 보여주고 있다. 한편 UNIDROIT(국제사법통일기구)에서는 우주자산의 구입 및 조달에 필요한 담보금 거래시 국제적으로 통일된 담보거래 규칙을 위한 "이동장비국제담보권협약에 대한 우주자산의정서"는 우주조약이 해결하지 못하고 있는 분야는 별도의 조약체결을 통하여도 보완되고 있다는 가능성을 보여주고 있는 것이다.

  • PDF

조선시대 회격·회곽묘 출토 삽(翣)에 대한 고찰 (A Study on the Excavated Sab(a funeral fan) from Lime-filled Tomb and Lime-layered Tomb during the Joseon Dynasty)

  • 이승해;안보연
    • 헤리티지:역사와 과학
    • /
    • 제41권2호
    • /
    • pp.43-59
    • /
    • 2008
  • 삽(?)은 유교 예법에 따른 상장례(喪葬禮) 도구로 나무로 틀을 만들고 그 위에 백포(白布)나 두꺼운 종이를 붙여 그림을 그린 후, 자루를 달아 들 수 있도록 한 것이다. "례기(禮記)"에 따르면 삽은 주대(周代)부터 사용되었던 것으로 기록되어 있는데, 우리나라의 "조선왕조실록(朝鮮王朝實錄)"이나 "국조오례의(國朝五禮儀)", "사례편람(四禮便覽)"에 나타난 삽의 용례와 크게 차이가 나지 않는다. 본고에서는 현존하는 조선시대 사대부가의 회격 회곽묘에서 발견되는 삽의 발굴 사례 및 문헌 기록을 통해 그 용례와 제작방식, 시기에 따른 유물의 특징에 대해 고찰하고자 한다. 삽은 신분에 따라 사용하는 개수와 그리는 문양이 다른데, 사대부가에서는 주로 '아(亞)'형의 불삽 1쌍과 구름 문양을 그린 화삽 1쌍을 사용하였다. 삽의 크기는 너비가 2자[척(尺)], 높이 2자[척(尺] 4치[촌(寸)]로 만들었는데 초주지나, 저주지로 두 번 싸고, 세 번째는 연창지로 쌌다. 그리고 나서 백저포, 마포, 무명, 공단 등으로 덮었다. 그 양면에 보불을 그리고 구름 변아(邊兒)에 운기를 그리는데 대개 주사 또는 진사를 사용하였다. 사대부가 회격 회곽묘에서 출토되는 삽은 광중에 부장된 것으로, 삽자루와 분리된 형태이다. 즉, 출토되는 삽은 발인행렬시 삽을 매달았던 5자 길이의 삽자루는 태워 없애고, 관의 좌우에 세워 넣은 것이다. 출토 유물의 검토를 통해서도 제작과정을 유추할 수 있다. 출토된 유물은 각(角)의 개수에 따라 각이 3개 달린 것과 2개 달린 것으로 대별된다. 먼저 각이 3개 달린 것(유형 I) 중에는 나무 통판을 사용하거나 대나무를 납작하게 갈라, 바구니처럼 엮은 것도 있다. 각이 3개인 삽은 비교적 조선 전기에 집중되어 있으며, 전체적인 형태에 비해 그 제작방식이 다양한 편으로 생각된다. 반면 각이 2개 달린 삽의 경우에는 비교적 정형화된 제작방식이 보인다. 직사각형이나 역사다리꼴로 몸통부분을 만든 후, 2개의 각이 달린 삽의 윗부분을 연결한 형태이다. 다만 상단면을 곡선(유형 II) 또는 직선(유형 III)으로 처리하는 것이 다르다. 이러한 제작방식은 각이 3개 달린 것에 비해 간단하며, 제작기법 상의 차이는 크지 않다. 특히 상단면을 직선으로 처리하는 방식은 오늘날까지도 사용되고 있다. 분석에 사용된 30건 중 묘주의 몰년, 즉 삽의 제작 연대가 명확한 것만 선택하여 분석한 결과, 유형 I은 16세기 전반에 집중되어 있음을 알 수 있다. 이어 유형 II는 16세기 후반부터 17세기 후반, 유형 III은 17세기 전반부터 18세기 전반까지 고르게 분포하고 있다. 요컨대 삽의 형태는 유형 I에서 유형 II로, 다시 유형 II에서 유형 III으로 변화하고 있는 것으로 생각된다. 17세기는 변화의 시기로 유형 II III이 혼재되어 있다. 유형을 크게 3가지로 구분하였으나 유형 II III은 각이 2개인 측면에서 그 형태가 유사하다고 볼 때 주목할 만한 전환기는 16세기 중반이라고 볼 수 있다. 아마도 유형 I은 유형 II III에 비해 제작 과정상 공이 더 많이 들어갈 것으로 생각되며, 후대로 내려올수록 경제성의 원리에 따라 삽의 형태 및 제작방법도 간소해진 것으로 보인다. 상장례의 간소화 경향은 "선조실록(宣祖實錄)"에 예장(禮葬)이 몇 차례 중지되는 사건들을 통해 임진왜란 이후에 가속화된 변화로 볼 수 있다. 삽의 경우 이미 16세기 후반부터 간소화되고 있었으며, 심지어 18세기에는 삽을 따로 제작하지 않고 구의(柩衣) 및 관(棺)에 직접 그리는 현상까지 초래하였다. 그러나 형태적으로 단순화 되는 과정에도 "례기(禮記)"의 삽 사용 규정은 지켜지고 있어, 그 의례의 형식은 합리적으로 간소화되었음을 알 수 있다.