• Title/Summary/Keyword: body angles

Search Result 425, Processing Time 0.022 seconds

Evaluation on the Radiation Exposure of Radiation Workers in Proton Therapy (양성자 치료 시 방사선 작업 종사자에게 미치는 방사선 피폭에 대한 평가)

  • Lee, Seung-Hyun;Jang, Yo-Jong;Kim, Tae-Yoon;Jeong, Do-Hyung;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Purpose: Unlike the existing linear accelerator with photon, proton therapy produces a number of second radiation due to the kinds of nuclide including neutron that is produced from the interaction with matter, and more attention must be paid on the exposure level of radiation workers for this reason. Therefore, thermoluminescence dosimeter (TLD) that is being widely used to measure radiation was utilized to analyze the exposure level of the radiation workers and propose a basic data about the radiation exposure level during the proton therapy. Materials and Methods: The subjects were radiation workers who worked at the proton therapy center of National Cancer Center and TLD Badge was used to compare the measured data of exposure level. In order to check the dispersion of exposure dose on body parts from the second radiation coming out surrounding the beam line of proton, TLD (width and length: 3 mm each) was attached to on the body spots (lateral canthi, neck, nipples, umbilicus, back, wrists) and retained them for 8 working hours, and the average data was obtained after measuring them for 80 hours. Moreover, in order to look into the dispersion of spatial exposure in the treatment room, TLD was attached on the snout, PPS (Patient Positioning System), Pendant, block closet, DIPS (Digital Image Positioning System), Console, doors and measured its exposure dose level during the working hours per day. Results: As a result of measuring exposure level of TLD Badge of radiation workers, quarterly average was 0.174 mSv, yearly average was 0.543 mSv, and after measuring the exposure level of body spots, it showed that the highest exposed body spot was neck and the lowest exposed body spot was back (the middle point of a line connecting both scapula superior angles). Investigation into the spatial exposure according to the workers' movement revealed that the exposure level was highest near the snout and as the distance becomes distant, it went lower. Conclusion: Even a small amount of exposure will eventually increase cumulative dose and exposure dose on a specific body part can bring health risks if one works in a same location for a long period. Therefore, radiation workers must thoroughly manage exposure dose and try their best to minimize it according to ALARA (As Low As Reasonably Achievable) as the International Commission on Radiological Protection (ICRP) recommends.

  • PDF

Design of Power and Load Reduction Controller for a Medium-Capacity Wind Turbine (중형 풍력터빈의 출력 및 타워 하중저감 제어기 설계)

  • Kim, Kwansu;Paek, Insu;Kim, Cheol-Jin;Kim, Hyun-Gyu;Kim, Hyoung-Gil
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.1-12
    • /
    • 2016
  • A control algorithm for a 100 kW wind turbine is designed in this study. The wind turbine is operating as a variable speed variable pitch (VSVP) status. Also, this wind turbine is a permanent magnet synchronous generator (PMSG) Type. For the medium capacity wind turbine considered in this study, it was found that the optimum tip speed ratios to achieve the maximum power coefficients varied with wind speeds. Therefore a commercial blade element momentum theory and multi-body dynamics based program was implemented to consider the variation of aerodynamic coefficients with respect to Reynolds numbers and to find out the power and thrust coefficients with respect tip speed ratio and blade pitch angles. In the end a basic power controller was designed for below rated, transition and above rated regions, and a load reduction algorithm was designed to reduce tower vibration by the nacelle motion. As a result, damage equivalent Load (DEL) of tower fore-aft has been reduced by 32%. From dynamic simulations in the commercial program, the controller was found to work properly as designed. Experimental validation of the control algorithm will be done in the future.

The Biomechanical Analysis of a One-Legged Jump in Traditional Korean Dance According to Breathing Method (호흡 방법에 따른 한국무용 외발뛰기 동작의 운동역학적 분석)

  • An, Ju-Yeun;Yi, Kyung-Ock
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.199-206
    • /
    • 2015
  • Objective : The purpose of this study was to conduct a biomechanical analysis of a one-legged jump in a traditional Korean dance (Wae Bal Ddwigi) according to breathing method. Method : Participants for this study were 10 dancers with experience for at least 10 years in traditional Korean dance. Independent variables for this test were two different types of breathing methods. Dependent variables were ground reaction force and lower extremity kinematic variables. The jumping movement was divided into three separate stages, take off, flight, and landing. The subjects were asked a questionnaire regarding the degree of impact force and stability of landing posture after the experiment. The Kistler Force Plate (9281B, Switzerland) was used to measure ground reaction force. A digital camera was used to look into angles of each joint of the lower part of body. SPSS was used for statistical analysis via the dependent t-test(p<.05). Results : There were significant differences in jumping according to breathing method. The inhalation & exhalation method yielded significantly longer flight times combined with greater ground reaction force. The breath-holding method required more core flexion during landing, increasing movement at the hips and shoulders. Conclusion : Consequently, there was more flexion at the knee to compensate for this movement. As a result, landing time was significantly higher for breath-holding.

Numerical Analysis of Incompressible and Compressible Flow Around a Butterfly Valve (버터플라이 벨브 주위의 비압축성 및 압축성유동 특성에 대한 수치해석)

  • 이종욱;이두환;최윤호
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.26-33
    • /
    • 2002
  • In this paper, incompressible and compressible flow characteristics around the butterfly valve have been investigated. In order to simplify the problem, a flat disk valve with various valve disk angles and pressure ratios is considered in the present calculations. It was found that as the disk angle increases, the stagnation point on the front surface of the disk moves to the center of the surface and the inflow velocity decreases. The maximum flow velocity occurs at the downstream of throat because of the formation of vents contracta. As the pressure ratio decreases, compressibility effects increase and the jet formed between the throttle body wall and the disk edge becomes supersonic. This flow also builds up as a shock cell structure. The increase of disk angle and pressure ratio makes the mass flow at the inlet decrease, while the increase of disk angle and the decrease of pressure ratio make the pressure loss coefficient increase.

Is All Anterior Oblique Fracture Orientation Really a Contraindication to Anterior Screw Fixation of Type II and Rostral Shallow Type III Odontoid Fractures?

  • Cho, Dae-Chul;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.345-350
    • /
    • 2011
  • Objective : It is debatable whether an anterior oblique fracture orientation is really a contraindication to anterior odontoid screw fixation. The purpose of this study was to investigate the feasibility of anterior odontoid screw fixation of type II and rostral shallow type III fracture with an anterior oblique fracture orientation. Methods : The authors evaluated 16 patients with type II and rostral shallow type III odontoid fracture with an anterior oblique fracture orientation. Of these 16 patients, 8 (group 1) were treated by anterior odontoid screw fixation, and 8 (group 2) by a posterior C1-2 arthrodesis. Results : Of the 8 patients in group 1, seven patients achieved solid bone fusion (87.5%), and one experienced screw back-out of the C-2 body two months after anterior screw fixation. All patients treated by posterior C1-C2 fusion in group 2 achieved successful bone fusion. Mean fracture displacements and fracture gaps were not significantly different in two groups. (p=0.075 and 0.782). However, mean fracture orientation angles were $15.3{\pm}3.2$ degrees in group 1, and $28.6{\pm}8.1$ degrees in group 2 (p=0.002), and mean fragment angulations were $3.2{\pm}2.1$ degrees in group 1, and $14.8{\pm}3.7$ degrees in group 2 (p=0.001). Conclusion : Even when the fracture lines of type II and rostral shallow type III fractures are oriented in an anterior oblique direction, anterior odontoid screw fixation can be feasible in carefully selected patients with a relatively small fracture orientation angle and relatively small fragment angulation.

Development of a Squat Angle Measurement System using an Inertial Sensor (관성 센서기반 스쿼트 각도 측정 융합 시스템 개발)

  • Joo, Hyo-Sung;Woo, Ji-Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.355-361
    • /
    • 2020
  • The squat is an exercise that can effectively improve the muscle strength of the lower body, which can be performed in a variety of places without restrictions on places including homes. However, injuries due to incorrect motion or excessive angles are frequently occurring. In this study, we developed a single sensor-based squat angle measurement system that can inform the squat angle according to the correct motion during the squat exercise. The sensor module, including the acceleration sensor and the gyro sensor, is attached to the user's thigh. The squat angle was calculated using the complementary filter complementing the pros and cons of acceleration and gyro sensor. It was found that the calculated squat angle showed the proper correlation compared to the squat angle measured by a goniometer, and the influence of the coefficient of the complementary filter on the accuracy was evaluated.

Analysis on the Walking Volumes of a Hexapod System with General 3R Link Legs (일반적 3R 링크를 갖는 6각 보행로봇 다리의 보행체적에 대한 해석)

  • Han, Gyu-Beom;Yang, Chang-Il;Baek, Yun-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.7
    • /
    • pp.2205-2212
    • /
    • 1996
  • In order to move the body of a walking robot translationally, and step over the obstacles, the walking robot must have at least 3 degrees of freedom for each leg. Therefore each leg of the general walking robots can be composed of 3-link system with 3 revolute joints. In this paper, the colsed form of inverse kinimatic solutions is shown for this general 3R linkage. Moreover, in order to have efficient walking volume in rough terrain, the workspace of each log is obtained considering the twist angles and the offsets in D-H parameters. When we design a walking robot, the information of the walking volume is needed for planning desired trajectories of the feet effectively. Appropriate knowledge of the walking volume can also be used to maximize linear or angular velocity of minimize power of stress. However, since it is impossible to obrain the information of walking volume in 3-D space directly from the kinematic equations, the walking volume can be searched through the edge detection algorithm using the triangle tracer with closed from inverse kinematic solutions. In this study, we present the closed form inverse kinematic solutions for 3R linkage model, and the walking volume of 6 legged walking robot which is modeled after the darking bettle, Eleodes obscura sulcipennis, through the method of edge detection for an arbitrary 2 dimensional shape using triangle tracer.

Design and Development of Virtual Reality Exergame using Smart mat and Camera Sensor (스마트매트와 카메라 센서를 이용한 가상현실 체험형 운동게임 시스템 설계 및 구현)

  • Seo, Duck Hee;Park, Kyung Shin;Kim, Dong Keun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.12
    • /
    • pp.2297-2304
    • /
    • 2016
  • In this study, we designed and developed the virtual reality Exergame using the smart mat and the camera sensor for exercises in indoor environments. For detecting the gestures of a upper body of users, the KINECT camera based the gesture recognition algorithm used angles between user's joint information system was adopted, and the smart mat system including a LED equipment and Bluetooth communication module was developed for user's stepping data during the exercises that requires the gestures and stepping of users. Finally, the integrated virtual reality Exergame system was implement along with the Unity 3D engine and different kinds of user' virtual avatar characters with entertainment game contents such as displaying gesture guideline and a scoring function. Therefore, the designed system will useful for elders who need to improve cognitive ability and sense of balance or general users want to improve exercise ability and the indoor circumstances such home or wellness centers.

Kinematic Comparative Analysis of Long Turns between Experienced and Inexperienced Ski Instructors

  • Jo, Hyun Dai
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.1
    • /
    • pp.17-25
    • /
    • 2020
  • Objective: The purpose of this study is to provide a better understanding of long turn mechanism by describing long turns after kinematic analysis and provide skiers and winter sports instructors with data through which they are able to analyze right postures for turns in skiing in a systematic, rational and scientific manner. Method: For this, a mean difference of kinematic variables (the center of gravity (CG) displacement of distance, trajectory, velocity, angle) was verified against a total of 12 skiers (skilled and unskilled, 6 persons each), regarding motions from the up-start to down-end points for long turns. Results: First, concerning the horizontal displacement of CG during a turn in skiing, skilled skiers were positioned on the right side at the upstart and edge-change points at a long turn. There was no difference in anteroposterior and vertical displacements. Second, in terms of CG-trajectory differences, skilled skiers revealed a significant difference during a long turn. Third, regarding skiing velocity, skilled skiers were fast at the edge-change and maximum inclination points in long turns. Fourth, there was no difference in a hip joint in terms of a lower limb joint angle. In a knee joint, a large angle was found at the up-start point among skilled skiers when they made a long turn. Conclusion: In overall, when skilled and unskilled skiers were compared, to make a good turn, it is required to turn according to the radius of turn by reducing weight, concerning the CG displacement. Regarding the CG-trajectory differences, the edge angle should be adjusted via proper inclination angulation. In addition, a skier should be more leaned toward the inside of a turn when they make a long turn. In terms of skiing velocity, it is needed to reduce friction on snow through the edging and pivoting of the radius or turn according to curvature and controlling ski pressure. Regarding a lower limb joint angle, it is important to make an up move by increasing ankle and knee angles instead of keeping the upper body straight during an up motion.

Kinematic Analysis between Three Groups according to Proficiency in Fencer's Fente Movement (펜싱 팡트 동작 숙련도에 따른 세 그룹간의 운동학적 비교분석)

  • Jo, Hyun Dai;Park, Ho Yeol
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.1
    • /
    • pp.51-61
    • /
    • 2020
  • Objective: The purpose of this study is to analyse and comparison the differences of kinematic variables for Fente skill in Fencing. Method: For this, 15 people were selected as 5 beginners with less than 2 years of experience, 5 intermediate-class people with more than 2 years and less than 4 years, and 5 experts-class people with more than 4 years. Through the comparison of Marche Fente motion according to proficiency, for the necessary time, travel distance, the kinematical factor of joint angle, oneway ANOVA was performed in order to identify differences according to variables by phase. Results: The time required for each phase was shown to be shorter for all phases experts than for beginners and intermediates. At the horizontal displacement of the foot, the right foot left out the last phase and the experts appeared long. The left foot showed short beginners in all phases. The angle of forward lean showed that the angle of forward lean was tilted forward by the experts of all phases. There was a difference between the left and right joint angles of the lower limb, both of the ankle, knee and hip joints. Conclusion: In overall, Beginners should quickly widen the distance of their feet when they make a Fente movement. The beginner shall tilt the upper body forward in order to increase the angle of forward lean. The beginner shall, in the last phase, have a smaller angle on the hip joint.