• Title/Summary/Keyword: blue laser

Search Result 220, Processing Time 0.026 seconds

On-Chip Fabrication of PDA Sensor Fiber Using Laser Polymerization and 3-D Hydrodynamic Focusing (3-D 유체집속효과와 레이저 중합반응을 이용한 PDA 센서 미세섬유 제작)

  • Yoo, Im-Sung;Song, Si-Mon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2692-2695
    • /
    • 2008
  • Polydiacetylene (PDA) is chemosensor materials that exhibit non-fluorescent-to-fluorescent transition as well as blue-to-red visible color change upon chemical or thermal stress. They have been studied in forms of film or microarray chip, so far. In this paper, we provide a novel technique to fabricate continuous micro-fiber PDA sensor using in-situ laser-polymerization technique and 3-D hydrodynamic focusing on a microfluidic chip. The flow of a monomer solution with diacetylene (DA) monomer is focused by a sheath flow on a 3-D microfluidic chip. The focused flow is exposed to 365 nm UV laser beam for in-situ polymerization which generates a continuous fiber containing DA monomers. Then, the fiber is exposed to 254 nm UV light to polymerize DA monomers to PDA. Preliminary results indicate that the fiber size can be controlled by the flow rates of the monomer solution and sheath flows and that a PDA sensor fiber successively responds to chemical and thermal stress.

  • PDF

Effects of Low Power Laser on Pain Response and Axonal Regeneration in Rat Models with Sciatic Nerve Crush Injury

  • Lee, Hong-Gyun;Kim, Yong-Eok;Min, Kyung-Ok;Yoo, Young-Dae;Kim, Kyung-Yoon;Kim, Gye-Yeop
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.3 no.1
    • /
    • pp.345-355
    • /
    • 2012
  • This study purposed to examine the effect of low power laser on pain response and axonal regeneration. In order to prepare peripheral nerve injury models, we crushed the sciatic nerve of Sprague-Dawley rats and treated them with low power laser for 21 days. The rats were divided into 4 groups: normal group(n=10); control group(n=10) without any treatment after the induction of sciatic nerve crush injury; experimental group I(n=10) treated with low power laser(0.21$mJ/mm^2$) after the induction of sciatic nerve crush injury; and experimental group II(n=10) treated with low power laser(5.25$mJ/mm^2$) after the induction of sciatic nerve crush injury. We measured spontaneous pain behavior(paw withdrawal latency test) and mechanical allodynia(von Frey filament test) for evaluating pain behavioral response, and measured the sciatic function index for evaluating the functional recovery of peripheral nerve before the induction of sciatic nerve crush injury and on day 1, 7, 14 and 21 after the induction. After the experiment was completed, changes in the H & E stain and toluidine blue stain were examined histopathologically, and changes in MAG(myelin associated glycoprotein) and c-fos were examined immunohistologically. According to the results of this study, when low power laser was applied to rat models with sciatic nerve crush injury for 21 days and the results were examined through pain behavior evaluation and neurobehavioral, histopathological and immunohistological analyses, low power laser was found to affect pain response and axonal regeneration in both experimental group I and experimental group II. Moreover, the effect on pain response and axonal regeneration was more positive in experimental group I to which output 0.21$mJ/mm^2$ was applied than in experimental group II to which 5.25$mJ/mm^2$ was applied.

The effects of low level laser radiation on bacterial growth

  • Chung, Wendy;Petrofsky, Jerrold S.;Laymon, Michael;Logoluso, Jason;Park, Joon;Lee, Judy;Lee, Haneul
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2014
  • Objective: The low level lasers currently in the market vary in wavelength, dosage, and frequency. These devices are used with much different clinical pathology. Most notably, some studies claim that wounds heal faster with low level laser therapy due to the fact that bacteria commonly found in wounds are killed by laser light. Systemic and meta-analysis studies found the difficulty of comparison of numerous research studies because of differences in the intensities and frequencies of low level laser treatment (LLLT). The purpose of this study was to determine the effectiveness of LLLT on controlling bacterial growth. Design: Cross-sectional study. Methods: Variables included LLLT dosage and wavelength on 3 bacteria commonly seen in wounds, strains of Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa were used on commercially available 5.0-cm agar plates. Blue, green, and red, ultraviolet (UV) and infrared laser light sources were adjusted to either low or high intensity settings. Five Petri dishes at a time were placed directly beneath laser light sources with the exception of UV which was placed six inches below the suspended light and infrared which was placed directly on top of the Petri dish lid. Each group of five Petri dishes was irradiated for 15 minutes. Results: The results showed no effect of any of 9 different LLLT intensities or colors on bacteria growth compared to sham light. Conclusions: At least for claims of bacterial growth inhibition with LLLT, no support for this claim can be found here.

Novel structure for a full-color AMOLED using a blue common layer (BCL)

  • Kim, Mu-Hyun;Chin, Byung-Doo;Suh, Min-Chul;Yang, Nam-Chul;Song, Myung-Won;Lee, Jae-Ho;Kang, Tae-Min;Lee, Seong-Taek;Kim, Hye-Dong;Park, Kang-Sung;Oh, Jun-Sik;Chung, Ho-Kyoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.797-798
    • /
    • 2005
  • We report a novel structure for a full-color AMOLED (Active Matrix Organic Light Emitting Diode) eliminating the patterning process of a blue emitting layer. The patterning of the three primary colors, RGB, is a key technology in the OLED fabrication process. Conventional full color AMOLED containing RGB layers includes the three opportunities of the defects to make an accurate position and fine resolution using various technologies such as fine metal mask, ink-jet printing and laser-induced transfer system. We can skip the blue patterning step by simply stacking the blue layer as a common layer to the whole active area after pixelizing two primary colors, RG, in the conventional small molecular OLED structure. The red and green pixel showed equivalent performances without any contribution of the blue emission.

  • PDF

Effect of Moisture Contant on The Printability of Domestic art paper in Korea Weather (우리나라 계절별 습도변화가 국산 아트지의 인쇄적성에 미치는 영향)

  • 이광석
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.16 no.2
    • /
    • pp.45-59
    • /
    • 1998
  • Halftonig is a technique to create the appearance of intermideate tone levels by controlling the spatial distribution of the binary pixel values. Recently, many printing devices such as image setter, inkjet printer, laser printer and facsimile, generate image, they require the technique. Ordered dither is achieved comparing the gray scale image to periodic array. This method is fast, but it occurs periodic patterns. Conentional error diffusion generates a good image. But processing speed is very slow and appeares worm artifacts in middle tone scale. To improve it, Bns(Blue noise Screen) is developed based on Gaussian distribution. In this paper, we discribe methods to design BNS based human visual characteristics and to improve blue appearing at edge area of image by USM(using unsharp mask).

  • PDF

Study on Dual-Lenses Actuator for HD-DVD System (차세대 DVD 시스템용 Actuator 연구)

  • Kim, Seok-Jung;Lee, Yong-Hoon;Ahn, Young-Man;Chung, Chong-Sam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.377.1-377
    • /
    • 2002
  • Recently, an optical disc system has been proposed using blue laser diode, high NA objective lens and groove only disc structure. A new method is needed to readout CD and DVD in the blue system. In order to readout CD and DVD in HD-DVD system, we adopted dual-lenses actuator in consideration of optical utilization efficiency, optical performance and insurance of sufficient W.D (working distance). (omitted)

  • PDF

Analysis of Homogenized Laser Beam Display by a Polymeric Stretchable Diffuser (스트레쳐블 폴리머 디퓨저를 이용한 균질 레이저 디스플레이 해석)

  • Lee, Jae-Won;Lee, Seon-Bong;Choi, Hae-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • A stretchable polymeric membrane shaped diffuser was used to homogenize the coherent laser beam. The developed RGB module was used to focus and defocus test by beam combiners. Average oscillation frequency was set at 180Hz~300Hz and it resulted in the best homogenization effect in visual range. The blue laser module turned out to be the worst case for the transmission and primary reason is believed to be the short length of irradiated laser beam. The developed system removed the speckling and the brightness was decreased by 10 ~ 20% for the RGB laser. Overall the brightness was decreased by 13% and homogenity with respect to the temporal axis was improved from 30fs to 110fs.

A Study of Weldability for Pure Titanium by Nd:YAG Laser(II) - Welding Properties of Butt Welding - (순티타늄판의 Nd:YAG 레이저 용접성에 관한 연구(II) - 맞대기 용접 특성 -)

  • Kim, Jong-Do;Kwak, Myung-Sub;Song, Moo-Keun;Park, Seung-Ha
    • Journal of Welding and Joining
    • /
    • v.27 no.6
    • /
    • pp.68-73
    • /
    • 2009
  • Recently, as titanium and titanium alloys are being increasingly used in wide areas, there are on-going researches to obtain high quality weld zone. In particular, growing interest is being drawn to laser welding, which involves low heat input and large aspect ratio in various welding processes and can facilitate shield in atmospheric condition compared with electron beam welding. The first report covered the analysis of embrittlement by the bead color of weld zone through quantitative analysis of oxygen and nitrogen and measurement of hardness as basic experiment to apply laser welding to titanium. Results indicated that the element that affect embrittlement the most was nitrogen, and as embrittlement and oxygenation go on, bead color changed to silver, gold, brown, blue and gray. This study performed butt welding of pure titanium and STS304 by using 1kW CW Nd:YAG laser, and to find out basic physical properties, evaluated welding performance by laser output, welding speed, root gap and misalignment etc, and examined mechanical properties through tensile stress and Erichsen test. The reason particles of pure titanium welded metal and HAZ are greater than STS304 is because they are pure metal and do not include many impure elements that work as nuclei in case of resolidification, thus becoming coarse columnar crystals eventually. In addition, the reason STS304 requires more energy during welding than pure titanium is because the particle size of base metal is smaller.

In Vitro Effect of 808-nm Diode Laser on Proliferation and Glycosaminoglycan Synthesis of Rabbit Articular Chondrocytes (토끼 관절 연골세포의 증식과 글리코스아미노글리칸 합성에 대한 808-nm 다이오드 레이저의 효능 평가)

  • Minar, Maruf;Hwang, Ya-won;Choi, Seok-hwa;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • The aim of the study was to assess the in vitro effect of 808-nm InGaAs diode laser on rabbit articular chondrocyte proliferation and sulphated glycosaminoglycan (sGAG) synthesis in alginate bead. Previous studies revealed either positive or negative stimulatory effects of laser on different types of cells. A 808-nm InGaAs diode laser at 1.0W power output was used to irradiate the rabbit chondrocytes in alginate beads with energy densities of $31J/cm^2$ (G 1) and $62J/cm^2$ (G 2) corresponding to the experimental groups for 10 seconds and 20 seconds, respectively at 24, 48, 72 and 96 hours after seeding. Control group was left untreated. MTT assay was performed at 1 week and 2 weeks after the $1^{st}$ laser irradiation in alginate beads. sGAG synthesis in alginate beads at 1 week and 2 weeks were determined by DMMB assay. Histological evaluation for cellular distribution and sGAG deposition around the cells were performed by alcian blue stain. MTT assay revealed no positive stimulatory effect in cell proliferation in alginate bead. DMMB assay results showed significantly increased sGAG production in G 2 chondrocytes at 2 weeks. Image analysis of alcian blue stained slides also showed significantly higher percentage of positive alcian blue stain in G 2 chondrocytes. This result suggests that 808-nm InGaAs diode laser with 1.0 W power output although cannot stimulate cell proliferation it can increase the cell secretion activity and sGAG deposition in alginate beads.

Stability Enhancement of Super-RENS Readout Signal

  • Kim, Joo-Ho;Lee, Yong-Woon;Hwang, Wook-Yeon;Shima, Takayuki;Chung, Chong-Sam
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.3
    • /
    • pp.123-125
    • /
    • 2007
  • We report the readout stability improvement results of super-resolution near field structure (Super-RENS) writeonce read-many (WORM) disk at a blue laser optical system. (Laser wavelength 405nm, numerical aperture 0.85) By using diffusion barrier structure (GeSbTe sandwiched by GeN) and high transition temperature recording material ($BaTiO_3$), material diffusion of phase change layer and recording mark degradation were greatly improved during high power (Pr=2.0mW) readout process up to $1{\times}10^5$ times.

  • PDF