• 제목/요약/키워드: blood velocity

검색결과 393건 처리시간 0.027초

The fruit of Acanthopanax senticosus Harms improves arterial stiffness and blood pressure: a randomized, placebo-controlled trial

  • Oh, Eunkyoung;Kim, Youjin;Park, Soo-yeon;Lim, Yeni;Shin, Ji-yoon;Kim, Ji Yeon;Kim, Ji-Hyun;Rhee, Moo-Yong;Kwon, Oran
    • Nutrition Research and Practice
    • /
    • 제14권4호
    • /
    • pp.322-333
    • /
    • 2020
  • BACKGROUND/OBJECTIVES: Arterial stiffness and endothelial dysfunction are 2 of the independent predictors for cardiovascular disease, while Acanthopanax senticosus Harms (ASH) is a traditional medicinal plant that can improve cardiovascular health. This study aimed to investigate the efficacy of the fruit of ASH on vascular function in apparently healthy subjects. SUBJECTS/METHODS: A 12-week, randomized, double-blind, placebo-controlled design, consisting of healthy adults with at least 2 of the following 3 conditions: borderline high blood pressure (BP; 120 mmHg ≤ systolic BP ≤ 160 mmHg or 80 mmHg ≤ diastolic BP ≤ 100 mmHg), smoking (≥10 cigarettes/day), and borderline blood lipid levels (220 ≤ total cholesterol ≤ 240, 130 ≤ low density lipoprotein cholesterol ≤ 165, or 150 ≤ triglyceride ≤ 220 mg/dL). Randomly assigned 76 subjects who received a placebo or 2 doses of ASH fruit (low, 500 mg/day; high, 1,000 mg/day) completed the intervention. Brachial-ankle pulse wave velocity (baPWV), flow-mediated dilation, carotid intima-media thickness, and BP were measured both at baseline and following the 12-week intervention. Endothelial nitric oxide synthase (eNOS) phosphorylation was assessed by western blotting. RESULTS: Compared with the placebo group, the low-dose group showed more significant changes after the 12-week intervention period in terms of systolic BP (0.1 vs. -7.7 mmHg; P = 0.044), baPWV (31.3 vs. -98.7 cm/s; P = 0.007), and the ratio of phospho-eNOS/eNOS (0.8 vs. 1.22; P = 0.037). CONCLUSIONS: These results suggest that ASH fruit extract at 500 mg/day has the potential to improve BP and arterial stiffness via endothelial eNOS activation in healthy adults with smoking and the tendency of having elevated BP or blood lipid parameters.

반복적인 실신 및 실신전환자의 기립경사 검사시 경두개 초음파 감시 (Transcranial Doppler Ultrasonography Monitoring during Head-up Tilt Test in Patients with Recurrent Syncope and Presyncope)

  • 조수진;이광호;정진상
    • Annals of Clinical Neurophysiology
    • /
    • 제1권1호
    • /
    • pp.64-69
    • /
    • 1999
  • Background : Syncope was defined as transient loss of consciousness and postural tone. The mechanisms of changes in cerebral hemodynamics during syncope have not been fully evaluated. Transcranial Doppler Ultrasonography can continuously monitor the changes in cerebral hemodynamics during head-up tilt (HUT). TCD could reveal the different patterns of changes in cerebral hemodynamics during syncope. Syncope without hypotension or bradycardia could be detected by TCD. We investigated the changes in cerebral blood flow velocity during HUT using TCD in 33 patients with a history of recurrent syncope or presyncope of unknown origin. Methods & Results : The positive responses were defined as presyncope or syncope with hypotension, bradycardia, or both. During HUT without isoproterenol infusion, there were a $86{\pm}23%$ drop in DV and a $41{\pm}34%$ drop in SV in 5 patients with positive reponses, and mean changes in those were less than 10% in patients with negative reponses (p=.00, p=.00). During HUT with isoproterenol infusion, TCD showed a $80{\pm}18%$ drop in diastolic velocity in 14 patients with positive reponses, and a $47{\pm}10%$ drop in that in patients with negative reponses (p=.00), however the change in systolic velocity did not differ. TCD showed three patterns during positive responses; loss of all flow, loss of end diastolic flow, and a decrease in diastolic velocity. Loss of consciousness occurred in the patients with loss of all flow or end-diastolic flow during positive reponses. Conclusions : TCD shows different patterns of changes in cerebral hemodynamics during HUT. TCD can be used to investigate the pathophysiology of neurocardiogenic syncope.

  • PDF

홀센서 집게형 맥진기와 심전도-용적맥파계를 이용한 한양방 융합용 환자감시장치 개발연구 (Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph)

  • 이대희;홍유식;이상석
    • 한국자기학회지
    • /
    • 제23권4호
    • /
    • pp.135-143
    • /
    • 2013
  • 요골 동맥의 중앙 부에 위치 한 "관"이란 곳에 영구자석 부착하여 맥의 움직임에 따라 발생하는 자기장의 변화를 홀센서로 정량화하여 맥진파형을 측정하는 집게형 맥진기를 개발하였다. 홀소자 맥진센서로 얻어진 전기적 신호로 심전도와 용적맥파계를 사용해 동시에 측정된 맥박수, 비침습적 혈압, 호흡수, 맥파전달속도와 공간맥파전달속도를 환자감시장치에 디스플레이하였다. 개발된 장치는 한방과 양방의 의료용 저장 매체와 새롭게 시도되거나 융합되어지고 있는 환자감시 장비 및 유비쿼터스 헬스케어 시스템 개발에 도움이 될 것이다.

시뮬레이션 복부 대동맥의 양방향 FSI 유속과 인체 4D flow MRI 유속의 상관계수, 급내상관계수 비교 (Comparison of Correlation Coefficients and Intraclass Correlation Coefficients Between Two-way FSI Flow Velocity of Simulated Abdominal Aorta and Human 4D Flow MRI Flow Velocity)

  • 안해남;김정훈;박지은;최현우;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제42권4호
    • /
    • pp.143-149
    • /
    • 2021
  • In order to predict and prevent the disease of the abdominal aorta, which is the largest artery in the human body and the most common aneurysm, the normal arterial blood flow operation should be considered. To this end, we are trying to solve problems that may arise in the future by executing FSI based on the data obtained from 4D flow MRI. However, to match the similarity between the 4D flow MRI flow and the FSI flow, correlation was used in previous papers, but the correlation did not show the degree of agreement. Therefore, in this paper, we analyzed the correlation between the 4D flow MRI flow velocity of the human abdominal aorta and the two-way FSI flow velocity in which the three physical properties used for the aortic FSI were added to the CT abdominal aorta 3D model and the interclass correlation coefficient. As a result, the physical property M2 showed the highest similarity in correlation and intraclass correlation coefficient, and this property is intended to be helpful in the future study of the abdominal aortic two-way FSI flow rate.

FSI 기법을 적용한 인체 회전 시 협착 혈관에서의 혈류 특성 (Study of Blood Characteristics in Stenosed Artery under Human Body Rotation by Using FSI Method)

  • 조성욱;김승욱;노경철;유홍선
    • 대한기계학회논문집B
    • /
    • 제37권5호
    • /
    • pp.449-457
    • /
    • 2013
  • 본 논문에서는 FSI(Fluid-Structure Interaction)기법을 이용하여 인체 회전의 영향을 고려한 혈류와 혈관벽의 거동을 이해하기 위한 수치해석을 수행하였다. 혈관은 협착률이 50%이고 편심이 없는 형상이며 인체 회전 효과를 묘사하기 위하여 혈관 주축에 대해 2 ~ 6 rps 의 회전을 가하였다. 협착과 축 회전의 영향으로 나선형, 비대칭 유동이 강체와 FSI 모델에서 모두 나타났다. 그러나 FSI 모델에서 혈관벽 움직임의 영향으로 혈류의 주기적, 과도적 차이가 발생했다. 특히 혈관 내 경화반의 진전과 경화반 위험성을 나타내는 대표적인 인자로 알려진 유동 재순환 영역이 감소하였다. 혈관벽의 움직임은 협착과 회전효과와 마찬가지로 유동 재순환 영역의 생성에 영향을 미친다.

비신축성 코르셋의 의복압으로 인한 생리적 반응의 변화 (Changes in Physiological Responses by the Pressure of Non-Elastic Corset)

  • 나영주;김양희
    • 한국의류산업학회지
    • /
    • 제13권6호
    • /
    • pp.943-951
    • /
    • 2011
  • The purpose of this study is to analyze the physiological effects of non-elastic corset on women's health and pain through measuring the clothing pressure, subjective pressure sensation, blood velocity and metabolism. 5 women in their twenties were picked as our subjects, their average size being 85cm at bust girth, 69 cm at waist girth. With the subjects each wearing a corset, we are testing in artificial environment with a treadmill according to the planned exercise procedures. The average pressure of the corset is 0.938 kPa (maximum 3.006 kPa at 45 degree front bowing), which is 10.2 times higher than the control group, averaging from 9.3 times higher at resting, 11.4 times at walking, 11.1 times at running. The effect of corset pressure on the physiological responses of the body is increased more when exercise than when resting. Clothing pressure increased in the order of the postures: sitting > standing with 45 degree bowing > standing. They experienced a high level of tighten discomfort of 5.6 in the scale of 1.0 to 7.0 due to the high pressure of the corset when resting, after intense exercise the level increased to 6.0, while without corset the level increased 1.7 to 2.2. With corset on, the blood circulation did not increase even though when the body exercised and blood flow became unbalanced making great gaps between both at the right and left finger tips. Perspiration of chest and back decreased 37.3% when wearing corset; 27.5% at resting, 56.7% at walking, 25.8% at running, and 39.0% at recovery. With corset on oxygen consume and metabolism increased 9.0%, 7.9%, respectively, which means the corset makes the body uncomfortable. Lung volume exchange VE decreased almost 4.1~7.3% with corset on and $VCO_2/VO_2$, RER and total volume in lung, VT also decreased too, which means the digestion of stomach and lung function are inhibited due to the high corset pressure.

상지동맥 혈관계의 모델링과 혈유동의 전산수치해석 (Modeling of the Artery Tree in the Human Upper Extremity and Numerical Simulation of Blood Flow in the Artery Tree)

  • 김기원;김재욱;백현만;김성균
    • 대한기계학회논문집B
    • /
    • 제40권4호
    • /
    • pp.221-226
    • /
    • 2016
  • 하지혈관에 비해 상지혈관질환은 드물기 때문에 상지혈관계에 대한 실험적, 수치해석적 연구는 매우 드물다. 본 논문에서는 최초로 MRA 영상데이터로부터 한국 성인 왼팔의 혈관계, 상완동맥에서 1 mm 이상의 손가락동맥들에 이르는, 3차원 컴퓨터 모델을 제작하였다. 이 모델에 대해 수치해석을 수행하여 정상, 주기유동에 대한 속도장, 압력장을 계산하였고 주요 분지관에서의 유량분배와 벽전단응력 분포에 대해 분석하였다.

Correlation between the morning hypertension on ambulatory blood pressure monitoring and the left ventricular mass in children

  • Kim, Hyun Jung;Kim, Kyung Hee;Kil, Hong Ryang
    • Clinical and Experimental Pediatrics
    • /
    • 제57권9호
    • /
    • pp.403-409
    • /
    • 2014
  • Purpose: Although high morning blood pressure (BP) is known to be associated with the onset of cardiovascular events in adults, data on its effects in children with hypertension are limited. Our retrospective study aimed to define the clinical characteristics of children with morning hypertension (MH) and to determine its associated factors. Methods: We reviewed 31 consecutive patients with hypertension, confirmed by the ambulatory blood pressure monitoring (ABPM). We divided these patients into 2 groups: the MH group (n=21, 67.7%), morning BP above the 95th percentile for age and height (2 hours on average after waking up) and the normal morning BP group (n=10, 32.3%). We compared the clinical manifestations, laboratory results, and echocardiographic findings including left ventricular hypertrophy (LVH) between the groups. Results: The early/atrial (E/A) mitral flow velocity ratio in the MH group was significantly lower than that in the normal morning BP group. In addition, LV mass was higher in the MH group than in the normal morning BP group, although the difference was not statistically significant. The age at the time of hypertension diagnosis was significantly higher in the MH group than in the normal morning BP group (P =0.003). The incidence of hyperuricemia was significantly higher in the MH group than in the normal morning BP group. Conclusion: Older patients and those with hyperuricemia are at higher risk for MH. The rise in BP in the morning is an important factor influencing the development of abnormal relaxation, as assessed by echocardiography. Clinical trials with longer follow-up periods and larger sample sizes are needed to clarify the clinical significance of MH.

Korean Red Ginseng Improves Vascular Stiffness in Patients with Coronary Artery Disease

  • Chung, Ick-Mo;Lim, Joo-Weon;Pyun, Wook-Bum;Kim, Hye-Young
    • Journal of Ginseng Research
    • /
    • 제34권3호
    • /
    • pp.212-218
    • /
    • 2010
  • Korean red ginseng (KRG) has been shown to enhance endothelium-dependent vasorelaxation in experimental animals; however, little is known about its pharmacological effects on vascular stiffness in patients with coronary artery disease (CAD). This randomized, double-blind, placebo-controlled crossover trial was carried out to determine whether KRG has beneficial effects on arterial stiffness, cardiovascular risk factors such as plasma lipid profiles and blood pressure (BP), and Rho-associated kinase (ROCK) activity. Twenty patients (mean age, 62.5 years) with stable angina pectoris were given KRG (2.7 g/day) and a placebo alternatively for 10 weeks. Blood biochemical analysis and pulse wave velocity (PWV) recording were performed on day 0 and after the completion of each treatment. ROCK activity was assessed based on the level of phospho-$Thr^{853}$ in the myosin-binding subunit of myosin light chain phosphatase, determined by Western blot analysis of peripheral blood mononuclear cells. KRG significantly decreased the systolic BP, brachial ankle PWV, and heart femoral PWV in the patients (all p<0.05), but did not significantly alter the serum lipid profiles, including triglycerides and total, high-density lipoprotein, and low-density lipoprotein cholesterol levels. The ROCK activity tended to decrease (p=0.068) following KRG treatment. The placebo did not significantly alter any of the variables. In conclusion, KRG decreased systolic BP and arterial stiffness, probably via the inhibition of ROCK activity, in patients with CAD, but had a neutral effect on serum lipid profiles. Our data suggest that KRG has a therapeutic effect on CAD.

Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels

  • Lim, Jaekwan;Won, Jong Yun;Ahn, Chi Bum;Kim, Jieon;Kim, Hee Jung;Jung, Jae Seung
    • Journal of Chest Surgery
    • /
    • 제54권2호
    • /
    • pp.81-87
    • /
    • 2021
  • Background: Artificial grafts such as polyethylene terephthalate (Dacron) and expanded polytetrafluoroethylene (ePTFE) are used for various cardiovascular surgical procedures. The compliance properties of prosthetic grafts could affect hemodynamic energy, which can be measured using the energy-equivalent pressure (EEP) and surplus hemodynamic energy (SHE). We investigated changes in the hemodynamic energy of prosthetic grafts. Methods: In a simulation test, the changes in EEP for these grafts were estimated using COMSOL MULTIPHYSICS. The Young modulus, Poisson ratio, and density were used to analyze the grafts' material properties, and pre- and post-graft EEP values were obtained by computing the product of the pressure and velocity. In an in vivo study, Dacron and ePTFE grafts were anastomosed in an end-to-side fashion on the descending thoracic aorta of swine. The pulsatile pump flow was fixed at 2 L/min. Real-time flow and pressure were measured at the distal part of each graft, while clamping the other graft and the descending thoracic aorta. EEP and SHE were calculated and compared. Results: In the simulation test, the mean arterial pressure decreased by 39% for all simulations. EEP decreased by 42% for both grafts, and by around 55% for the native blood vessels after grafting. The in vivo test showed no significant difference between both grafts in terms of EEP and SHE. Conclusion: The post-graft hemodynamic energy was not different between the Dacron and ePTFE grafts. Artificial grafts are less compliant than native blood vessels; however, they can deliver pulsatile blood flow and hemodynamic energy without any significant energy loss.