• 제목/요약/키워드: blood velocity

검색결과 393건 처리시간 0.025초

천마추출물이 정상인의 뇌혈류에 미치는 영향 (Effect of Gastrodia Elata BL Water Extract on Human Cerebral Blood Flow using Transcranial Doppler)

  • 문상관;김영석;박성욱;정우상;고창남;조기호;배형섭
    • 대한한의학회지
    • /
    • 제26권1호
    • /
    • pp.115-122
    • /
    • 2005
  • Background and objective: Gastrodiae Rhizoma (GR), the rhizoma of Gastrodia elata BL., is one of the popular drugs to treat headache, dizziness, blackout, numbness of limbs, hemiplegia, facial paralysis, dysphrasia, and infantile convulsions. It has been reported that it provides an antihypertensive effect and lowers cerebrovascular resistance in animal experiments. However, there has been no data about these effects with human subjects. In this study, the author examined the effect of Gastrodiae water extracts on blood pressure and cerebrovascular reactivity in human subjects. Methods: We selected 16 normal volunteers, who were divided into 2 groups: Gastrodiae extract administration group and placebo (creamy powder) group. Using transcranial Doppler ultrasound, we monitored changes of mean flow velocity and breath-holding induced CO2 reactivity of middle cerebral artery in both groups. Mean blood pressure, heart rate and PETCO2 were measured using Compact Anesthesia Monitor. In both groups, all evaluation was performed during basal condition, and repeated at 30, 60, and 90 min after administration. Results: Gastrodiae extract decreased CO2 reactivity after administration, reaching the lowest level at 90 minutes $(-29.1\%\;vs.\;basal\;level)$, which showed significant difference compared with the placebo group (p = 0.004). In the placebo group, the pulse rates tended to decrease over time (at 90 minute, $-5.2\%$ vs. basal level) while in the Gastrodiae group the values showed nearly no change, which showed significant difference between both groups (p = 0.036). However, the changes of mean blood pressure and mean flow velocity did not show significant difference between both groups. Conclusion : This study demonstrated that Gastrodiae extract significantly decreased breath-holding induced CO2 reactivity. This result suggests that the clinical effect of Gastrodiae extract might be caused by increasing cerebral blood flow via dilation of cerebral resistant vessels instead of antihypertensive effect.

  • PDF

정상 청소년에서 맥파 속도와 발목 상완 동맥압 지수에 대한 연구 (Pulse wave velocity and ankle brachial index in normal adolescents)

  • 김지혜;길태영;이희우;홍영미
    • Clinical and Experimental Pediatrics
    • /
    • 제50권6호
    • /
    • pp.549-555
    • /
    • 2007
  • 목 적 : 성인에서 맥파 속도와 발목 상완 동맥압 지수는 동맥 경직도를 측정할 수 있는 비침습적 방법이며 혈압, 고지혈증 등의 심혈관계 위험 인자와 연관성이 있어 심혈관계 질환과 관련이 있음이 알려져 있다. 본 연구는 우리나라 청소년에서 신장, 체중, 체질량 지수와 혈압, 맥파 속도, 발목 상완 동맥압 지수를 측정하였고 이들 사이의 상관성을 알아보고 정상 기준값를 확립하고자 하였다. 방 법 : 서울 시내 3개 고등학교에 재학 중인 15-16세 사이의 청소년 392명(남자 213명, 여자 179명)을 대상으로 신장, 체중, 체질량지수, 좌우 상완 및 발목의 수축기, 이완기, 평균 혈압과 양측 맥파 속도, 발목 상완 동맥압 지수, 박출 시간, 전구출기를 VP-1000(Colin사, Komaki, Japan)을 이용하여 측정하였다. 결 과 : 사지의 수축기, 이완기 평균 혈압은 남자에서 여자보다 유의하게 높은 값을 보였다(P<0.05). 우측 상완-발목 맥파 속도는 남자에서 $1,015.4{\pm}130.0cm/sec$, 여자에서 $947.6{\pm}105.1cm/sec$로서 남자에서 유의하게 높은 값을 보였다. 좌측 상완 발목 맥파 속도도 마찬가지로 남자에서 $1,023.4{\pm}132.5cm/sec$, 여자에서 $954.6{\pm}102.4cm/sec$로 남자에서 유의하게(P<0.05) 높은 값을 보였다. 발목 상완 동맥압 지수는 남녀 간에 유의한 차이를 보이지 않았다. 우측 상완-발목 맥파 속도의 기준값는 남자에서 1,032.4 cm/sec, 여자에서 963.1 cm/sec이었고, 좌측 상완-발목 맥파 속도는 남자에서 1,041.3 cm/sec, 여자에서 969.7 cm/sec이었다. 우측 발목 상완 동맥압 지수의 기준값은 남자에서 1.06, 여자에서 1.06이었으며, 좌측 발목 상완 동맥압지수의 기준값은 남자에서 1.05, 여자에서 1.06이었다. 맥파 속도는 사지 모두에서 혈압이 높아질수록, 유의한 양의 상관관계를 보였다. 또한 신장이 커질수록, 체중이 증가할수록, 체질량지수가 커질수록 사지의 혈압이 증가하는 유의한 양의 상관관계를 보였다. 반면, 발목 상완 동맥압 지수는 남녀 사이에 유의한 차이가 없었으며, 체중, 신장, 체질량지수 어느 것과도 유의한 상관관계가 없었다. 결 론 : 혈압은 신장, 체중, 체질량지수에 따라 높아지며 맥파 속도와 혈압 사이에도 유의한 양의 상관관계가 있다. 정상 청소년에서 측정한 맥파 속도의 기준값을 바탕으로 심혈관계 질환의 위험도를 조기 발견하고 예측하는데 유용하게 사용할 수 있을 것으로 생각한다.

인삼, 홍삼 및 발효 홍삼이 정상인의 뇌혈류, 평균혈압, 맥박수에 미치는 영향 (Effects of Korean Ginseng, Korean Red Ginseng and Fermented Korean Red Ginseng on Cerebral Blood Flow, Cerebrovascular Reactivity, Systemic Blood Pressure and Pulse Rate in Humans)

  • 정동원;홍진우;신원준;박영민;정재한;김창현;민인규;박성욱;정우상;박정미;고창남;조기호;문상관
    • 대한한의학회지
    • /
    • 제27권3호
    • /
    • pp.38-50
    • /
    • 2006
  • Objectives: The aim of this study was to evaluate the effects of Korean ginseng (KG), Korean red ginseng (KRG) and fermented Korean red ginseng (FKRG) extracts on cerebral hemodynamics and to compare distinction of each extract. Methods: Ten healthy male volunteers $(26.0{\pm}1.8yrs)$ participated in the study according to double-blind and cross-over protocols. Each volunteer was blindly administered 500mg of KG, KRG, FKRG extract or placebo (Dextrin). Blinded researchers measured changes of hyperventilation-induced cerebrovascular reactivity (CVR), mean blood flow velocity (MBFV) of middle cerebral arteries (MCAs) and corrected blood flow velocity at $P_{ETCO2}=40mmHg$ (CV40) using transcranial Doppler ultrasound (DWL Co., Germany). Researchers also observed changes of mean blood pressure (MBP), pulse rate (PR) and expiratory $CO_2$ using S/5 Collector (Datex-Ohmeda Co., Finland). The evaluation was performed at basal condition, and repeated at 1, 2, 3, 4 and 5 hours after administration. Results: MBFV and CV40 in the KRG group tended to rise at I hour after administration, while those of the FKRG group tended to rise at 2 hours after administration. CVR increased significantly after 1 hour in the KRG group (p=0.009) and after 2 hours in the FKRG group (p=0.035), respectively. The KG group showed increasing tendency at 4 hours after administration. No group showed significant difference from the placebo in changes of MBP and PR. Conclusions: It is suggested that KG, KRG and FKRG extracts have effects of enhancing CVR and thus of increasing cerebral blood flow in human subjects.

  • PDF

APPLICATION OF DOUBLE DECOMPOSITION TO PULSATILE FLOW

  • Mamaloukas, C.;Haldar, K.;Mazumdar, H.P.
    • Journal of applied mathematics & informatics
    • /
    • 제10권1_2호
    • /
    • pp.193-207
    • /
    • 2002
  • The present investigation deals with the pulsatile flow of incompressible viscous fluid through a circular rigid tube provided with constriction. The method applied here is the Decomposition Method, which has been developed by George Adomian [3]. The advantages of this method are the avoidance of simplifications and restrictions, which change the non-linear problem to mathematically tractable one, whose solution is not consistent with physical solution. Theoretically results, such as, wall shear stress and axial velocity component, have been obtained and the graphical solutions of these theoretical results have been shown in the figures.

임상 경두개 도플러 검사 (Clinical Transcranial Doppler)

  • 김종순;류재관
    • 대한물리치료과학회지
    • /
    • 제6권4호
    • /
    • pp.153-165
    • /
    • 1999
  • The transcranial Doppler(TCD) is a technique for measuring blood flow velocity of intracranial and extarcranial arteries. This examination based on Doppler effect which was first formulated in 1842 by the Austrian physicist Christian Doppler. In 1982, Rune Aaslid first maked 2MHz pulsed probe and recording intracranial vessels with transcranially. There are six criteria utilized in gaining positive identification of the intracranial vessels. The six criteria are as follows l)acoustical windows 2)depth of sample volume 3)direction of flow 4)spatial relationship of ACA and MCA bifurcation 5)mean velocity and 6)response common carotid artery compression and/or oscillation test. The affected factors for TCD examination are angle of insonation, posture of subject, age, gender, hematocrit, metabolic factors, and cardiac output. Clinical application of TCD are detection of stenosis, occlusion, emboli, thrombsis in intracranial and extracranial arteries and evaluation of cerebral arterovenous malformation, collateral capacity in the circle of Willis, ischemia cerebrovascular disease, stroke patient and vertebrobasilar system.

  • PDF

혈류 진단을 위하여 직렬데이터 처리를 하는 다중(128) 채널 초음파 펄스 도플러 시스템에 관한 연구 (A Study on a Multichannel(128) Ultrasound Pulsed Doppler System with Serial Data Processing for Sensing the Blood Flow)

  • Kim, Young-Kil
    • 대한전자공학회논문지
    • /
    • 제23권3호
    • /
    • pp.389-396
    • /
    • 1986
  • A pulsed ultrasonic doppler flowmeter for mesurements of velocity profils in man is described. The device projects a beam of ultrasound in burst of 570 ns duration at 3.5 MHz. The back-scattered signals are processed to produce a signal oxrresponding to the mean velocity over a small region of the flowing stream. The observation range of 112mm is divided into 128 depth channels. The size of this sample volume determines the flowmeter sensitivity and accuracy. The device uses a quadrature detector to detect the direction of the moving target(hemoglobin). The main feature of the novel instrumnet is its simple hardware structure due to sequential signal processing.

  • PDF

A HEART MODEL IN THE CIRCULATORY SYSTEM

  • Jung, E.;Kim, Y.;Lee, W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.266-268
    • /
    • 2011
  • We present a mathematical model of left heart governed by the partial differential equations. This heart is coupled with a lumped model of the whole circulatory system governed by the ordinary differential equations. The immersed boundary method is used to investigate the intracardiac blood flow and the cardiac valve motions of the normal circulation in humans. We investigate the intraventricular velocity field and the velocity curves over the mitral ring and across outflow tract. The pressure and flow are also measured in the left and right heart and the systemic and pulmonary arteries. The simulation results are comparable to the existing measurements.

  • PDF

CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석 (Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images)

  • 홍이송;김민철;강현민;이종선;김찬중;이종민;김대수;이건
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.497-503
    • /
    • 2004
  • 건강한 정상인의 복부대동맥과 장골동맥 분기관의 다이콤 의료 영상으로부터 구성된 혈관 모델을 대상으로 전산혈류해석을 수행하였다. 본 연구에서는 CT로 촬영한 혈관영상으로부터 단면영상을 읽고 각 단면의 경계 좌표를 매끄럽게 추출하는 프로그램을 개발하여 적응하였다. 해석용 3차원 메쉬 생성과 혈류해석은 상용프로그램을 사용하였다. 해석을 통해 얻어진 압력, 속도 및 유량 분포는 정상인의 생리학적 범위 내에 있었다. 초음파로 측정된 장골동맥 중심부의 심장 수축기 속도는 해석에 비해 20% 정도 작은 값을 보였으며 한 주기 동안 속도 변화의 경향은 유사하였다. 본 연구의 접근방법은 환자 개인의 실제 혈관 형상에 기반한 혈류해석으로서 좁아진 동맥 또는 시술 될 동맥에서의 압력, 속도값, 속도분포에 대한 정보를 제공한다. 이 결과는 의사로 하여금 환자의 혈류역학적 변수의 변화를 파악하게 하여 환자의 상태를 더 잘 이해하고 수술의 필요성을 판단하도록 도움을 줄 수 있으며 나아가 혈관 수술의 기초자료로 사용될 수 있을 것이다. 이 연구는 향후 동맥경화와 밀접히 연관된 혈류역학적 변수의 분포를 혈관 내에 보여줌으로서 동맥경화를 조기 진단하는 프로그램으로 발전할 것으로 기대된다.

Cross-Correlation법에 의한 피부 혈류속도 측정 (Measurement of the Skin Blood Flow using Cross-Correlation)

  • 이정택;임춘성;류점수;이종수;공성배;김영길
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권4호
    • /
    • pp.379-384
    • /
    • 1998
  • 본 연구에서는 초음파를 이용하여 피부 혈관에서 그 위치에 대한 혈류 신호정보를 얻을 수 있는 펄스파(pulsed wave) 시스템을 이 분야에 응용하기 위한 가능성을 고찰하였다. 20MHz의 변환자로 수신된 신호들은 시간 영역에서 서로 비교하여 편이량을 cross-correlation방법을 사용하여 혈류속도를 구하였다. 피부의 매우 작은 혈관에서 혈류속도 거출시 발생되는 문제점에 대해 in-vitro와 in-vivo 실험을 통해서 이 방법의 효용성을 보이고 그 문제점에 대한 해결 방법을 제시한다. 시간 편이량 측정은 cross-correlation방법에 의해 정규화된 계수에서 최대점을 찾는 것이며 송신주기에 따라 반사된 수신 신호에서부터 cross-correlation방법을 사용하여 속도를 구한다. In-패패 실험을 통해 작은 튜브 내의 깊이에 대한 속도 정보를 주는 속도 profile과 이론적으로 계산된 속도 rpofile을 비교하였으며 토끼 귀 부분의 auriculares caudales에서 소동맥과 소정맥에 대한 혈류속도 profile을 구하였다. 수신 신호에서 진동에 의한 오차는 DFT를 사용하여 보정하였고 클루터 신호는 전체 수신 신호를 평균하여 하나의 기준 수신 신호를 정하여 이것에서 다른 수신 신호 값을 뺌으로써 감소시켰다.

  • PDF

대사증후군 환자군과 정상군의 뇌혈류 측정 비교를 통한 뇌졸중 위험인자에 대한 TCD의 진단적 가치 고찰 (Comparison of Cerebral Blood Flow between Patients with Metabolic Syndrome and Normal Group to Evaluate Diagnostic Value of Transcranial Doppler Ultrasound)

  • 엄은진;박우람;김주성;이범준;나병조
    • 대한한의진단학회지
    • /
    • 제14권2호
    • /
    • pp.85-100
    • /
    • 2010
  • Objectives: The purpose of this study was to evaluate diagnostic value of Transcranial Doppler Ultrasound about risk factor of stroke by comparing blood flow between patients with metabolic syndrome(MS group) and Normal group. Methods: 62 metabolic syndrome patients and 106 healthy adults were selected who had no cerebrovascular diseases, cardiovascular diseases and other systemic diseases. We measured the mean velocity(Vm), peak systolic velocity(Vs) and pulsatility index(PI) of MCA, ACA, PCA, VA, ICA in two groups using TCD. All subjects were divided by gender and age. Results: In comparing Ms group with normal group, Vm in the MCA, ACA, PCA, ICA and Vs in the MCA, ICA were lower in MS group. In all vessels, PI of MS group were higher than that of Normal group. In all vessels, Vm and Vs revealed negative correlation with age and PI revealed positive correlation with age. In 20-39 year olds, there was decrease in the Vs and Vm and increase of PI of MS group in comparison with normal group. There was significant difference in the Vm of PCA, ICA, Vs of MCA, PCA, ICA and PI of MCA, ACA. In 40-59 year olds, Vm in the MCA, ACA, ICA and Vs in the MCA, ACA were lower in MS group. PI in the MCA, ACA, PCA, ICA were higher in MS group. In 60-79 year olds, Vm of MCA, PCA, ICA was decreased in MS group than Normal group with no statistical signification. Vs in the MCA was lower and PI in the PCA was higher in MS group. In male, Vm of PCA and Vs of MCA were lower and PI of MCA, ACA, PCA, ICA were higher in MS group. In female, Vm of MCA, PCA, ICA and Vs of MCA, ICA were lower and PI of ACA, PCA, VA, ICA were higher in MS group. Conclusions: The significant difference in Vm, Vs, PI between MS group and normal group suggests hemodynamic disorder. Screening and prognosing high risk group can be done through TCD and this can be used to prevent stroke. More detailed study will be needed.