• Title/Summary/Keyword: blood velocity

Search Result 393, Processing Time 0.031 seconds

Effects of DaeSiHo-Tang extract on Hypertension and Arterial Contraction (대시호탕(大柴胡湯)이 고혈압과 수축혈관에 미치는 영향)

  • Yeo Un-Hong;Jo Hak-Jun;Kim Ho-Hyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.6
    • /
    • pp.1573-1579
    • /
    • 2005
  • This study was undertaken to define the effect of DaeSiHo-Tang extract on the hypertension in spontaneous hypertensive rat and norepinephrine-induced arterial contraction in rabbit. Systolic blood pressure and blood velocity were significantly attenuated by administration of DaeSiHo-Tang extract. but blood flow and renin-angiotensin-aldosterone system unaffected by DaeSiHo-Tang extract. The relaxation effect of DaeSiHo-Tang extract was dependent on the presence of endothelium, showing that DaeSiHo-Tang extract-induced relaxation was not observed in the strips without endothelium. The endothelium-dependent relaxation induced by DaeSiHo-Tang extract was decreased by the pretreatment of $N{\omega}$-nitro-L-arginine or methylene blue, but it was not observed in the strips pretreated with indomethacin or tetraethylammonium chloride. When $Ca^{2+}$ was applied, the strips which were contracted by norepinephrine in a $Ca^{2+}$-free solution, arterial contraction was increased. But pre-treatment of DaeSiHo-Tang extract inhibited contractile response to $Ca^{2+}$. These results indicate that antihypertensive effect of DaeSiHo-Tang extract is due to descend arterial resistance by the arterial relaxation through the formation of nitric oxide in the vascular endothelial cells.

Flow Visualization of Arteriovenous Grafting Using PIV Technique (PIV 기법을 이용한 동정맥루 문합에 대한 유동가시화)

  • Jeon, Min-Gyu;Kim, Hyoung-Ho;Suh, Sang-Ho;Choi, Young Ho;Lee, Hyun-Jin;Doh, Deog-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.985-990
    • /
    • 2013
  • An arteriovenous fistula is artificially produced using a graft for hemodialysis in patients. In an arteriovenous graft (AVG), the angle of its arterial or venous anastomosis play an important role in producing flows inside blood vessels, through which a stenosis may occur. Most studies thus far have focused on CFD results. In this study, a PIV technique is used to analyze the hemodynamic characteristics at the arterial or venous anastomosis of an AVG having an angle of $30^{\circ}C$. For flow dynamic similarity, the Reynolds number is set to be the same for real and simulated flows. A PIV experiment is performed with a control valve in the arterial part. In conclusion, the recirculation flow appeared in the bifurcation area and the total blood velocity changed according to the extent of valve opening.

A preliminary simulation for the development of an implantable pulsatile blood pump

  • Di Paolo, Jose;Insfran, Jordan F.;Fries, Exequiel R.;Campana, Diego M.;Berli, Marcelo E.;Ubal, Sebastian
    • Advances in biomechanics and applications
    • /
    • v.1 no.2
    • /
    • pp.127-141
    • /
    • 2014
  • A preliminary study of a new pulsatile pump that will work to a frequency greater than 1 Hz, is presented. The fluid-structure interaction between a Newtonian blood flow and a piston drive that moves with periodic speed is simulated. The mechanism is of double effect and has four valves, two at the input flow and two at the output flow; the valves are simulated with specified velocity of closing and reopening. The simulation is made with finite elements software named COMSOL Multiphysics 3.3 to resolve the flow in a preliminary planar configuration. The geometry is 2D to determine areas of high speeds and high shear stresses that can cause hemolysis and platelet aggregation. The opening and closing valves are modelled by solid structure interacting with flow, the rhythmic opening and closing are synchronized with the piston harmonic movement. The boundary conditions at the input and output areas are only normal traction with reference pressure. On the other hand, the fluid structure interactions are manifested due to the non-slip boundary conditions over the piston moving surfaces, moving valve contours and fix pump walls. The non-physiologic frequency pulsatile pump, from the viewpoint of fluid flow analysis, is predicted feasible and with characteristic of low hemolysis and low thrombogenesis, because the stress tension and resident time are smaller than the limit and the vortices are destroyed for the periodic flow.

Pulse wave velocity and ankle brachial index in adolescents with essential hypertension (본태성 고혈압 청소년에서 pulse wave velocity와 ankle brachial index에 대한 연구)

  • Joo, Sun Young;Cho, Ki Young;Cho, Su Jin;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.7
    • /
    • pp.769-776
    • /
    • 2006
  • Purpose : Pulse wave velocity(PWV) and ankle brachial index(ABI) are not only noninvasive methods used to assess arterial stiffness in adults, but also useful, simple ways to estimate the severity of hypertension, end stage renal disease and atherosclerosis in adults. But there are few studies on PWV and ABI in adolescents and children. In this study, hypertensive adolescents were compared to normal individuals to find out the usefulness of PWV as the index of progress in the disease. Methods : 413 teenagers were divided into three groups. The first group consisted of adolescents that only had hypertension(Group 1 : 23 teenagers). The second group consisted of the adolescents who had hypertension with obesity(Group 2 : 17 teenagers), and the last group was the normal subjects(Group 3 : 328 teenagers). Weight, height and body mass index were measured. Simultaneous measurements of systolic, diastolic and average blood pressure were obtained from the four extremities. PWV, ABI, ejection time and preejection period were also measured. Results : Right brachial-ankle PWV was significantly higher in both group 1 and group 2 compared with group 3, and significantly higher in group 2 compared with group 1. Likewise, left brachial-ankle PWV also showed significantly higher values in both group 1 and group 2 compared with group 3, and also higher values in group 2 compared with group 1. Positive correlations were found between the systolic, diastolic, average blood pressure and PWV. There were also positive correlations between the blood pressure and weight, body mass index. Conclusion : Higher PWV was demonstrated in adolescents with essential hypertension compared to normal subjects. Follow-up study is needed to evaluate the progress.

Quantitative Flow Field Visualization of a Flow inside an Opaque Tube Using Angiographic PIV Method (X선관을 이용한 불투명한 물체 내부 유동의 정량적 가시화 연구)

  • Kim, Guk-Bae;Lim, Nam-Yun;Ryu, Jae-Chun;Yim, Dae-Hyun;Lee, Hyung-Koo;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2935-2940
    • /
    • 2007
  • To diagnose circulatory diseases in the viewpoint of hemodynamics, we need to get quantitative hemodynamic information of blood flows related with the vascular diseases with high spatial resolution of tens micrometer and high temporal resolution in the order of millisecond. For investigating in-vivo hemodynamic phenomena, a new diagnosing technique combining medical radiography and PIV method was newly proposed and developed. This angiographic PIV technique consists of a medical X-ray tube, an X-ray CCD camera, a shutter module for double pulses of X-ray, and a synchronizer. The feasibility of the angiographic PIV technique was tested and quantitative flow velocity field distribution of a flow inside an opaque conduit was acquired by the developed system. It can be used for measuring flow phenomena of nontransparent fluids inside opaque conduits.

  • PDF

CFD ANALYSIS FOR THE DRAG OF AN INTERIOR BODY IN A PULSATILE FLOW WITH VARIOUS SHAPE DESIGN (맥동류 내 물체 형상에 따른 항력에 대한 CFD 계산)

  • Hwang, D.Y.;Han, Byeong-Yun;Yu, Seong-Su;Lee, Myeong-Su;Park, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.38-43
    • /
    • 2009
  • The objective of this study is to get a fundamental data for the shape of a robot which operates in blood vessels. The overall analysis was calculated with a CFD code. The flow was idealized as a pulsatile flow, and first the robot was assumed as a simple capsule model. Then a drag of the body in the flow was calculated, and this process was repeated, varying the shape. To validate all the result, the pulastile velocity simulation was compared with the theoretical data, and the drag of a body was compared with the existing data of the other papers first. Then with the next calculation the guideline for the design of robot shape was presented.

  • PDF

The Technique and Normal Values of Transcranial Doppler Ultrasonography(TCD) (Transcranial Doppler Ultrasonography (TCD)의 시행 방법 및 정상치)

  • Sohn, Young Ho
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 1999
  • Transcranial doppler ultrasonography (TCD) is a new, non-invasive and easily applicable method to evaluate cerebral hemodynamics. Last 10 years, its use in Korea has been dramatically expanded, but the qualification of TCD laboratory has yet to be settled. Since duplex sonography is seldom used in Korea, we have to depend totally on TCD to evaluate cerebral hemodynamic changes. Thus, all of the available data from every detectabler cerebral arteries has to be obtained for accurate interpretation of TCD measurements. Moreover, flow direction and wave form should be concerned in addition to the flow velocity. In this article, I present technique to measure the anterior, meddle and posterior cerebral arteries, the internal carotid artery siphon and at cervical level, and the vertebral and the basilar artery, and normal values for these measurements which is essential for the adequate interpretation.

  • PDF

Subclinical Neuropathy at 'Safe' Levels of Lead Exposure

  • Seppalanen Anna Maria;Tola Sakari;Hernberg Sven;Kock Boria
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02a
    • /
    • pp.545-548
    • /
    • 1994
  • Eletrophysiological methods revealed subclinical neuropathy in 26 workers, exposed from 1 to 17 years to lead and whose blood lead (PbB) values had never exceeded $70{\mu}g/100\;ml$, as ascertained by checking the monitor reports of the factory and by careful exposure history. The PbB determinations had been tested repostedly and had been found valid. The main findings were slowing of the maximal motor conduction velocities of the median and ulnar nerves and particularly the conduction velocity of the slower fibers of the ulnar nerve. Eletrophysiological abnormalities comprised fibriliations, diminution of the number of motor units on maximal contraction, and an abnormal. Thus, a dose-response relationship exlets on a group basis. Since the regular monitoring of PbBs in most workers during their entire period of exposure excludes the possibility of a body burden out of proportion to the PbBs silght neuro-logical damage is produced at exposures hitherto regarded as quite sale.

  • PDF

Artificial blood flow measurement using Ultrasound Time Domain Correlation (Ultrasound Time Domain Correlation을 이용한 가상 혈류 속도 측정)

  • 김의준
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1992.06a
    • /
    • pp.103-106
    • /
    • 1992
  • 기존의 혈류 속도 측정 방법으로는 인체내에 반사 물질을 투입하는 Fick technique과 electromagnetic flowmeter등을 이용한 invasive method와 Ultrasonic Doppler method에 의한 noninvasive method가 이용되고 있다. 이 방법들은 혈과의 모양이나 혈관에서의 flow velocity profile등에 관한 정확한 정보를 얻을 수 없다. 이와같은 문제점들을 해결하기 위한 혈류속도 측정 방법으로 실험실 조건하에서 인체에서와 유사한 혈류측정 장치를 제작하여, vessel의 표본 체적내의 산란체로부터 후방산란되는 초음파 신호의 correlation을 이용한 Ultrasound Time Domain Correlation (UTDC) technique을 연구하였다. UTDC technique을 이용하여 유속을 측정한 결과, 12% 이하의 정밀도로 평균 유체 유속이 측정되었고, Ultrasonic Doppler method에서 측정할 수 없는 혈과의 모양과 혈관의 각 위치에서의 유속 및 혈관벽에 이물질의 존재여부를 명확히 판단할 수 있었다.

  • PDF

The Characteristics os Water Quality of Tap water and Far-infrared rays mineral water (수돗물과 원적외선 기능수의 수질 특성의 비교)

  • 백우현
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.423-428
    • /
    • 2000
  • The characteristics of Far-infrared rays mineral water(FIR water) have been compared to the tap water by means of relationship between FIR water and Nuclear Magnetic Resonance spectroscopy(NMR), FIR water and thermography FIR water and velocity of blood FIR-water and pH, FIR water and dissolved oxygen(DO), FIR water and Oxidation-Reduction Potential(ORP) using the development FIR water purification of grand prix system. From the experimental result are quite satisfactory when compared with the tap water. Also the FIR water were evaluated to see if those are tasty and healthy using the Hashimoto's Mineral Balance Index. As a result FIR-water was found as tasty and healthy.

  • PDF