• Title/Summary/Keyword: blood velocity

Search Result 393, Processing Time 0.027 seconds

Effect of Gastrodia Elata BL Water Extract on Human Cerebral Blood Flow using Transcranial Doppler (천마추출물이 정상인의 뇌혈류에 미치는 영향)

  • Moon Sang-Kwan;Kim Young-Suk;Park Seong-Uk;Jung Woo-Sang;Ko Chang-Nam;Cho Ki-Ho;Bae Hyung-Sup
    • The Journal of Korean Medicine
    • /
    • v.26 no.1 s.61
    • /
    • pp.115-122
    • /
    • 2005
  • Background and objective: Gastrodiae Rhizoma (GR), the rhizoma of Gastrodia elata BL., is one of the popular drugs to treat headache, dizziness, blackout, numbness of limbs, hemiplegia, facial paralysis, dysphrasia, and infantile convulsions. It has been reported that it provides an antihypertensive effect and lowers cerebrovascular resistance in animal experiments. However, there has been no data about these effects with human subjects. In this study, the author examined the effect of Gastrodiae water extracts on blood pressure and cerebrovascular reactivity in human subjects. Methods: We selected 16 normal volunteers, who were divided into 2 groups: Gastrodiae extract administration group and placebo (creamy powder) group. Using transcranial Doppler ultrasound, we monitored changes of mean flow velocity and breath-holding induced CO2 reactivity of middle cerebral artery in both groups. Mean blood pressure, heart rate and PETCO2 were measured using Compact Anesthesia Monitor. In both groups, all evaluation was performed during basal condition, and repeated at 30, 60, and 90 min after administration. Results: Gastrodiae extract decreased CO2 reactivity after administration, reaching the lowest level at 90 minutes $(-29.1\%\;vs.\;basal\;level)$, which showed significant difference compared with the placebo group (p = 0.004). In the placebo group, the pulse rates tended to decrease over time (at 90 minute, $-5.2\%$ vs. basal level) while in the Gastrodiae group the values showed nearly no change, which showed significant difference between both groups (p = 0.036). However, the changes of mean blood pressure and mean flow velocity did not show significant difference between both groups. Conclusion : This study demonstrated that Gastrodiae extract significantly decreased breath-holding induced CO2 reactivity. This result suggests that the clinical effect of Gastrodiae extract might be caused by increasing cerebral blood flow via dilation of cerebral resistant vessels instead of antihypertensive effect.

  • PDF

Pulse wave velocity and ankle brachial index in normal adolescents (정상 청소년에서 맥파 속도와 발목 상완 동맥압 지수에 대한 연구)

  • Kim, Ji Hye;Gil, Tae Young;Lee, Hee Woo;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.6
    • /
    • pp.549-555
    • /
    • 2007
  • Purpose : Pulse wave velocity (PWV) and ankle brachial index (ABI) are simple, non-invasive methods to assess arterial stiffness. These parameters are also known to be closely related to cardiovascular risk factors and diseases. The purposes of this study were to measure blood pressure, PWV, ABI in healthy Korean adolescents, set up their normal values and assess their correlations. Methods : Three hundred ninety two healthy adolescents (213 boys and 179 girls) underwent measurement of brachial ankle pulse wave velocity (baPWV), ABI, body mass index(BMI) and blood pressure from four extremities. Linear regression analysis was performed to reveal the correlations between PWV, ABI and independent variables. Results : Blood pressure and PWV were significantly higher in all extremities in males compared to females. Blood pressure of both brachial and ankle showed positive correlation with body weight, height, and BMI, whereas ABI showed no correlation with any of these indices. Conclusion : Blood pressure increases as body weight, height and BMI increases. PWV shows positive correlation with blood pressure. It will be helpful to predict the risks of cardiovascular diseases in adolescents.

Effects of Korean Ginseng, Korean Red Ginseng and Fermented Korean Red Ginseng on Cerebral Blood Flow, Cerebrovascular Reactivity, Systemic Blood Pressure and Pulse Rate in Humans (인삼, 홍삼 및 발효 홍삼이 정상인의 뇌혈류, 평균혈압, 맥박수에 미치는 영향)

  • Jeong, Dong-Won;Hong, Jin-Woo;Shin, Won-Jun;Park, Young-Min;Jung, Jae-Han;Kim, Chang-Hyun;Min, In-Kyu;Park, Seong-Uk;Jung, Woo-Sang;Park, Jung-Mi;Go, Chang-Nam;Cho, Ki-Ho;Moon, Sang-Kwan
    • The Journal of Korean Medicine
    • /
    • v.27 no.3 s.67
    • /
    • pp.38-50
    • /
    • 2006
  • Objectives: The aim of this study was to evaluate the effects of Korean ginseng (KG), Korean red ginseng (KRG) and fermented Korean red ginseng (FKRG) extracts on cerebral hemodynamics and to compare distinction of each extract. Methods: Ten healthy male volunteers $(26.0{\pm}1.8yrs)$ participated in the study according to double-blind and cross-over protocols. Each volunteer was blindly administered 500mg of KG, KRG, FKRG extract or placebo (Dextrin). Blinded researchers measured changes of hyperventilation-induced cerebrovascular reactivity (CVR), mean blood flow velocity (MBFV) of middle cerebral arteries (MCAs) and corrected blood flow velocity at $P_{ETCO2}=40mmHg$ (CV40) using transcranial Doppler ultrasound (DWL Co., Germany). Researchers also observed changes of mean blood pressure (MBP), pulse rate (PR) and expiratory $CO_2$ using S/5 Collector (Datex-Ohmeda Co., Finland). The evaluation was performed at basal condition, and repeated at 1, 2, 3, 4 and 5 hours after administration. Results: MBFV and CV40 in the KRG group tended to rise at I hour after administration, while those of the FKRG group tended to rise at 2 hours after administration. CVR increased significantly after 1 hour in the KRG group (p=0.009) and after 2 hours in the FKRG group (p=0.035), respectively. The KG group showed increasing tendency at 4 hours after administration. No group showed significant difference from the placebo in changes of MBP and PR. Conclusions: It is suggested that KG, KRG and FKRG extracts have effects of enhancing CVR and thus of increasing cerebral blood flow in human subjects.

  • PDF

APPLICATION OF DOUBLE DECOMPOSITION TO PULSATILE FLOW

  • Mamaloukas, C.;Haldar, K.;Mazumdar, H.P.
    • Journal of applied mathematics & informatics
    • /
    • v.10 no.1_2
    • /
    • pp.193-207
    • /
    • 2002
  • The present investigation deals with the pulsatile flow of incompressible viscous fluid through a circular rigid tube provided with constriction. The method applied here is the Decomposition Method, which has been developed by George Adomian [3]. The advantages of this method are the avoidance of simplifications and restrictions, which change the non-linear problem to mathematically tractable one, whose solution is not consistent with physical solution. Theoretically results, such as, wall shear stress and axial velocity component, have been obtained and the graphical solutions of these theoretical results have been shown in the figures.

Clinical Transcranial Doppler (임상 경두개 도플러 검사)

  • Kim, Jong-Soon;Ryoo, Jae-Kwan
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.4
    • /
    • pp.153-165
    • /
    • 1999
  • The transcranial Doppler(TCD) is a technique for measuring blood flow velocity of intracranial and extarcranial arteries. This examination based on Doppler effect which was first formulated in 1842 by the Austrian physicist Christian Doppler. In 1982, Rune Aaslid first maked 2MHz pulsed probe and recording intracranial vessels with transcranially. There are six criteria utilized in gaining positive identification of the intracranial vessels. The six criteria are as follows l)acoustical windows 2)depth of sample volume 3)direction of flow 4)spatial relationship of ACA and MCA bifurcation 5)mean velocity and 6)response common carotid artery compression and/or oscillation test. The affected factors for TCD examination are angle of insonation, posture of subject, age, gender, hematocrit, metabolic factors, and cardiac output. Clinical application of TCD are detection of stenosis, occlusion, emboli, thrombsis in intracranial and extracranial arteries and evaluation of cerebral arterovenous malformation, collateral capacity in the circle of Willis, ischemia cerebrovascular disease, stroke patient and vertebrobasilar system.

  • PDF

A Study on a Multichannel(128) Ultrasound Pulsed Doppler System with Serial Data Processing for Sensing the Blood Flow (혈류 진단을 위하여 직렬데이터 처리를 하는 다중(128) 채널 초음파 펄스 도플러 시스템에 관한 연구)

  • Kim, Young-Kil
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.3
    • /
    • pp.389-396
    • /
    • 1986
  • A pulsed ultrasonic doppler flowmeter for mesurements of velocity profils in man is described. The device projects a beam of ultrasound in burst of 570 ns duration at 3.5 MHz. The back-scattered signals are processed to produce a signal oxrresponding to the mean velocity over a small region of the flowing stream. The observation range of 112mm is divided into 128 depth channels. The size of this sample volume determines the flowmeter sensitivity and accuracy. The device uses a quadrature detector to detect the direction of the moving target(hemoglobin). The main feature of the novel instrumnet is its simple hardware structure due to sequential signal processing.

  • PDF

A HEART MODEL IN THE CIRCULATORY SYSTEM

  • Jung, E.;Kim, Y.;Lee, W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.266-268
    • /
    • 2011
  • We present a mathematical model of left heart governed by the partial differential equations. This heart is coupled with a lumped model of the whole circulatory system governed by the ordinary differential equations. The immersed boundary method is used to investigate the intracardiac blood flow and the cardiac valve motions of the normal circulation in humans. We investigate the intraventricular velocity field and the velocity curves over the mitral ring and across outflow tract. The pressure and flow are also measured in the left and right heart and the systemic and pulmonary arteries. The simulation results are comparable to the existing measurements.

  • PDF

Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images (CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석)

  • Hong Y. S.;Kim M. C.;Kang H. M.;Lee C. S.;Kim C. J.;Lee J. M.;Kim D. S.;Lee K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • Numerical simulation of blood flow has been conducted based on real vessel geometries generated front DICOM medical images of abdominal and iliac bifurcated arteries of a healthy man. A program was developed to read cross sectional images of the three dimensional arteries and smoothly extract boundary coordinates of vessels. Commercial programs were employed for mesh generation and flow simulation. Pressures, velocities, and flow distributions were found to lie within normal physiological ranges. Peak velocity measured in the iliac artery by ultrasound was 20% smaller than that obtained by simulation. The trend of velocity variation in a cardiac cycle was fairly similar between the simulation and the ultrasonic measurements. Simulation based on real vessel geometry of individual patient provides information on pressure, velocity, and its distribution in the diseased arteries or arteries to be surgically treated. The results of simulation may help surgeons to better understand hemodynamic status and surgical need of the patient by revealing variation of the hemodynamic parameters. Futhermore, they may serve as basic data for surgical treatment of arteries. This research is expected to develop to a program in the future that early diagnose atherosclerosis by showing distribution of a hemodynamic index closely related to atherosclerosis in arteries.

Measurement of the Skin Blood Flow using Cross-Correlation (Cross-Correlation법에 의한 피부 혈류속도 측정)

  • Lee, Jeong-Taek;Im, Chun-Seong;Ryu, Jeom-Su;Lee, Jong-Su;Gong, Seong-Bae;Kim, Yeong-Gil
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.379-384
    • /
    • 1998
  • To measure precisely the blood velocity in the skin microcirculation, we have used time domain correlation (called Cross-Correlation) based on the processing of the backscattered RF signal obtained with a wideband echographic imaging transducer, although it is difficulties of adaptation of the pulsed wave system, because of the data processing in real time and the hardware problem. This dedicated technology based on a 20MHz echographic imaging system has been developed. We present how the experimental data, i.e. the backscattered RF signal, have to be analyzed. After RF lines realignment, stationary echo canceling procedure and correlation level control, a velocity profile has been obtained. In-vitro result show that velocity measurements as low as 0.1mm/sec attainable with a 80${\mu}m$ in axial resolution. We have also validated with in-vivo experimentation on the external ear of a rabbit using B-mode sector scanning image and M-mode image of a custom made 20MHz skin image system. The flow of the "auriculares caudales" vein, a microvessel of 600 m diameter, has been detected and studied. This technique will allow a more precise exploration of circulatory troubles in cutaneous pathologies.

  • PDF

Comparison of Cerebral Blood Flow between Patients with Metabolic Syndrome and Normal Group to Evaluate Diagnostic Value of Transcranial Doppler Ultrasound (대사증후군 환자군과 정상군의 뇌혈류 측정 비교를 통한 뇌졸중 위험인자에 대한 TCD의 진단적 가치 고찰)

  • Um, Eun-Jin;Park, Woo-Rham;Kim, Ju-Sung;Lee, Beom-Joon;Na, Byung-Jo
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.85-100
    • /
    • 2010
  • Objectives: The purpose of this study was to evaluate diagnostic value of Transcranial Doppler Ultrasound about risk factor of stroke by comparing blood flow between patients with metabolic syndrome(MS group) and Normal group. Methods: 62 metabolic syndrome patients and 106 healthy adults were selected who had no cerebrovascular diseases, cardiovascular diseases and other systemic diseases. We measured the mean velocity(Vm), peak systolic velocity(Vs) and pulsatility index(PI) of MCA, ACA, PCA, VA, ICA in two groups using TCD. All subjects were divided by gender and age. Results: In comparing Ms group with normal group, Vm in the MCA, ACA, PCA, ICA and Vs in the MCA, ICA were lower in MS group. In all vessels, PI of MS group were higher than that of Normal group. In all vessels, Vm and Vs revealed negative correlation with age and PI revealed positive correlation with age. In 20-39 year olds, there was decrease in the Vs and Vm and increase of PI of MS group in comparison with normal group. There was significant difference in the Vm of PCA, ICA, Vs of MCA, PCA, ICA and PI of MCA, ACA. In 40-59 year olds, Vm in the MCA, ACA, ICA and Vs in the MCA, ACA were lower in MS group. PI in the MCA, ACA, PCA, ICA were higher in MS group. In 60-79 year olds, Vm of MCA, PCA, ICA was decreased in MS group than Normal group with no statistical signification. Vs in the MCA was lower and PI in the PCA was higher in MS group. In male, Vm of PCA and Vs of MCA were lower and PI of MCA, ACA, PCA, ICA were higher in MS group. In female, Vm of MCA, PCA, ICA and Vs of MCA, ICA were lower and PI of ACA, PCA, VA, ICA were higher in MS group. Conclusions: The significant difference in Vm, Vs, PI between MS group and normal group suggests hemodynamic disorder. Screening and prognosing high risk group can be done through TCD and this can be used to prevent stroke. More detailed study will be needed.