• Title/Summary/Keyword: blood velocity

Search Result 393, Processing Time 0.026 seconds

Effects of Uwhangchungsimwon(牛黃淸心元) on Cerebral Blood Flow and Systemic Blood Pressure in Humans (우황청심원이 정상인의 뇌혈류 및 혈압에 미치는 영향)

  • Kim, Young-Suk
    • The Journal of Internal Korean Medicine
    • /
    • v.20 no.1
    • /
    • pp.222-231
    • /
    • 1999
  • Uwhangchungsimwon(UC) has been used in the treatment of a wide variety of conditions including stroke, hypertension, arteriosclerosis, autonomic imbalance, mental instablity, etc in Korean traditional hospitals, In particular it is often initialy chosen for emergency care of acute stroke. The aim of this study was to evaluate the effect of UC on cerebral hemodynamics. Using transcranial Doppler ultrasound, we studied changes of mean flow velocity and pulsatility index(PI) of middle cerebral arteries (MCAs) from 11 health young volunteers who were administrated with 1 pill UC and 11 health controls who were not. We obtained hypercapnia with breath-holding and evaluated cerebrovascular reactivity with breath-holding index(BHI). Systolic blood pressure, diastolic blood pressure, and heart rate were measured using ambulatory blood pressure monitoring(ABPM). In UC administration group, the evaluation was performed during basal condition. and repeated at 20, 40, and 60 min after administration. In controls, the evaluation was performed at corresponding time intervals. Mean flow velocity in middle cerebral artery, systolic blood pressure, diastolic blood pressure, and heart rate did not change during the observation period and were not different between these two groups. However, administration of UC was associated with decreases in PI by $3.6{\sim}12.4%$ in BHI by $17.9{\sim}24.8%$ compared with pre-administration period. Decreases in PI and BHI with UC were significantly different compared with control group (p<0.05). These results indicate that UC decreases PI and BHI in cerebral artery, which is due to a dilation of cerebral resistance vessels.

  • PDF

Modeling of Hemodynamics in Stenosed Artery (협착 동맥혈관의 혈류유동 모델링)

  • Kim, Seong-Jong;Park, Young-Ran;Kim, Shagn-Jin;Kang, Hyung-Sub;Kim, Jin-Shang;Oh, Sung-Hoon;Kang, Sung-Jun;Kim, Gi-Beum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2285-2290
    • /
    • 2012
  • This study is about atherosclerosis which occupies the highest rate in many diseases people have and we have studied about atherosclerosis for abdominal aorta. Atherosclerosis is the phenomenon which blood vessel gets narrower, harder and thicker due to the stenosis of colesterol in blood vessel. If it becomes worse, arteries will be hard and blood can't flow smoothly, and even it can reach to death. In this study, the geometric models of the considered stenotic blood flow are two different types of constriction of cross-sectional area of blood vessel; 20 and 45% of constriction in each elastic wall and rigid wall. We have modeled by using finite element method to observe the changes of velocity and pressure. In case of the diameter of blood vessel decreased 45% in elastic wall model, the values of velocity and pressure were higher than the case of 20% and in case of the diameter of blood vessel decreased 45% in rigid wall model, the values of velocity and pressure were higher than the case of 20%. In cases of elastic wall models of the diameters of blood vessels decreased each of 20% and 45%, recirculation zones appeared. This results show understanding of hemodynamic properties depending on stenosed blood vessels.

Blood flow velocity in the anterior humeral circumflex artery and tear size can predict synovitis severity in patients with rotator cuff tears

  • Takahiro Machida;Takahiko Hirooka;Akihisa Watanabe;Hinako Katayama;Yuki Matsukubo
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.11-17
    • /
    • 2024
  • Background: Rotator cuff tears are often associated with synovitis, but the ability of noninvasive ultrasonography to predict the severity of synovitis remains unclear. We investigated whether ultrasound parameters, namely peak systolic velocity in the anterior humeral circumflex artery and Doppler activity in the glenohumeral joint and subacromial space, reflect synovitis severity. Methods: A total of 54 patients undergoing arthroscopic rotator cuff repair were selected. Doppler ultrasound was used to measure peak systolic velocity in the anterior humeral circumflex artery and Doppler activity in the glenohumeral joint and subacromial space, and these values were compared with the intraoperative synovitis score in univariate and multivariate analyses. Results: Univariate analyses revealed that tear size, peak systolic velocity in the anterior humeral circumflex artery, and Doppler activity in the glenohumeral joint were associated with synovitis in the glenohumeral joint (P=0.02, P<0.001, P=0.02, respectively). In the subacromial space, tear size, peak systolic velocity in the anterior humeral circumflex artery, and Doppler activity in the subacromial space were associated with synovitis severity (P=0.02, P<0.001, P=0.02, respectively). Multivariate analyses indicated that tear size and peak systolic velocity in the anterior humeral circumflex artery were independently associated with synovitis scores in both the glenohumeral joint and the subacromial space (all P<0.05). Conclusions: These findings demonstrate that tear size and peak systolic velocity in the anterior humeral circumflex artery, which can both be measured noninvasively, are useful indicators of synovitis severity.

Clinical Study of Blood Flow Velocity Using Transcranial Doppler Ultrasound on Cerebral Arteries in Dizziness Patients (경두개 도플러 초음파를 이용한 현훈 환자의 뇌혈관 혈류 측정에 관한 임상적 연구 (중대뇌동맥, 추골동맥 및 기저동맥을 중심으로))

  • Kim, Bong-Suk;Oh, Jung-Han;Kim, Dong-Woo;Choi, Bin-Hye;Jang, Woo-Seok;Seo, Young-Ho;Son, Dae-Yong;Byun, Joon-Seok;Lim, Hee-Yong
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.418-426
    • /
    • 2004
  • Objectives : This study was designed to research whether transcranial doppler ultrasound(TCD) can yield a suitable diagnosis or prognosis for dizziness. Methods : To evaluate the blood flow, we measured the mean velocity(Vm), peak systolic velocity(Vs) and pulsatility index(PI) of the middle cerebral artery(MCA), vertebral artery(VA) and basilar artery(BA) in 54 dizziness patients and 44 normal subjects. To investigate the difference between dizziness patients and normal subjects, we selected 54 dizziness patients diagnosed normal by Brain MRI, and 44 normal subjects who did not have any symptoms of hyperlipemia, hypertension, diabetes melitus, heart disease, or smoking, diagnosed normal by Brain MRI. 30-69 year olds were divided into 30-49 year olds, 50-59 year olds and 60-69 year olds. Results : In normal subjects, there was a significantly higher Vm, Vs in the MCA and BA, and Vs in the VA of female subjects, and there was a significant difference in PI in the MCA and BA increasing with age. In comparison with normal subjects, dizziness patients had a significantly lower Vm in the BA. Male dizziness patients had significantly lower PI in the MCA. 30-49 year olds had significantly lower Vm in the BA. Conclusions : The significant difference in blood flow velocities in the BA between dizziness patients and normal subjects suggests that dizziness is related to blocking of blood flow in the BA and that diagnosis and prognosis can be made through TCD. More detailed study of dizziness patients will be needed.

  • PDF

The Effect of Electrical Stimulation Applied in Dominant Forearm on Autonomic Nervous System Response of Both Hands (우세측 전완에 적용한 전기자극이 양쪽 손 자율신경계 반응에 미치는 효과)

  • Lee, Dong-Geol;Seo, Sam-Ki;Lee, Jeong-Woo
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.7-10
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate the effect of electrical stimulation applied in dominant forearm on autonomic nervous system response of both hands. Methods : Fourteen healthy subjects (women) received low frequency-high intensity electrical stimulation to one forearm. The subjects assigned to two groups; a ipsilateral stimulation group (n=7) and a contralateral stimulation group (n=7). The electrode attachment was arranged on the forearm of the dominant arm and the electricity stimulus time was set as 15 minutes. Measuring items were the skin conduction velocity, the blood flow, and the pulse rate, which were measured total 3 times (pre, post, and post 10 min.). Results : The skin conduction velocity showed a significant difference according to the change of the time in both hands, but there was no significant difference according to time in the blood flow, and the change of the pulse frequency regardless of stimulus side. Conclusion : These results demonstrate that the low frequency-high intensity electrical stimulation applied dominant forearm can increase selectively only with the skin conduction velocity, which may be helpful for the activation of the sudomotor function of both hands by the activation of sympathetic nerve.

Development of X-ray PIV Technique and Its Applications (X-ray PIV 기법의 개발과 적용연구)

  • Lee Sang Joon;Kim Guk Bae;Kim Seok;Kim Yang-Min
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.20-25
    • /
    • 2005
  • An x-ray PIV (Particle Image Velocimetry) technique was developed fur measuring quantitative information on flows inside opaque conduits and/or opaque-fluid flows. To check the performance of the x-ray PIV technique developed, it was applied to a liquid flow in an opaque Teflon tube. To acquire x-ray images suitable for PIV velocity field measurements, the refraction-based edge enhancement mechanism was employed with seeding detectable tracer particles. The amassed velocity field data obtained were in a reasonable agreement with the theoretical prediction. The x-ray PIV technique was also applied to get velocity fields of blood flow and to measure size and velocity of micro-bubbles simultaneously, and to visualize the water refilling process in bamboo leaves. The x-ray PIV was found to be a powerful transmission-type flow imaging technique fur measuring quantitative information of flows inside opaque objects and various opaque-fluid flows.

  • PDF

Scan Time Analysis Using 4D Phase-Contrast MRI According to Scan Parameter: A Phantom Study (스캔 인자에 따른 4D 위상 대조 자기공명영상을 이용한 스캔 시간 분석: 팬텀 연구)

  • Park, Jieun;Kim, Junghun;Hwang, Moonjung;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.179-184
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effect according to the NEX, VENC, targeted cardiac phases on the velocity measurement of 4D phase-contrast MRI. Materials and Methods: The abdominal aortic phantom was made to experiment. The working fluid was mixed with water and glycerin to mimic the density and viscosity of human blood. The inlet velocity was Reynolds number 2000. The experimental conditions were NEX 1 and 4, VENC 102 cm/s and 200 cm/s, and 10 and 15 targeted cardiac phases, respectively. The average flow rate, average velocity, maximum velocity, and cross-section area were measured. Results: As a result of the case-by-case comparison, the error rate was less than 5%. There was no significant difference (p > 0.05). Conclusion: It is expected that this result will be useful for acquiring blood flow information in clinical practice.

Development and physiological assessments of multimedia avian esophageal catheter system

  • Nakada, Kaoru;Hata, Jun-ichi
    • Journal of Multimedia Information System
    • /
    • v.5 no.2
    • /
    • pp.121-130
    • /
    • 2018
  • We developed multimedia esophageal catheters for use with birds to measure and record ECG and angular velocity while anesthesized, at rest, and in flight. These catheters enable estimates of blood pressure based on readings given by an angular velocity sensor and by RR intervals of ECG affected by EMG. In our experiments, the catheters had the following characteristics: 1. Esophageal catheters offer a topological advantage with 8-dB SNR improvement due to elimination of electromyography (EMG). 2. We observed a very strong correlation between blood pressure and the angular velocity of esophageal catheter axial rotation. 3. The impulse conduction pathway (Purkinje fibers) of the cardiac ventricle has a direction opposite to that of the mammalian pathway. 4. Sympathetic nerves predominate in flight, and RR interval variations are strongly suppressed. The electrophysiological data obtained by this study provided especially the state of the avian autonomic nervous system activity, so we can suspect individual's health condition. If the change of the RR interval was small, we can perform an isolation or screening from the group that prevent the pandemics of avian influenza. This catheter shall be useful to analysis an avian autonomic system, to perform a screening, and to make a positive policy against the massive infected avian influenza.

The Effects of LI4, TE3, TE5 and LI11 Moxibustion on Radial Artery Blood Flow and Heart Rate Variability in Stoke Patients with Hemiplegia (합곡.중저.외관.곡지 뜸치료가 뇌졸중 편마비 환자의 환측 요골동맥 혈류 및 심박변이도에 미치는 영향)

  • Yoon, Seung-Kyou;Kwon, Seung-Won;Seo, Yu-Ri;Park, Joon-Young;Im, Jin-Wook;Park, Joo-Young;Cho, Seung-Yeon;Jung, Hwan-Yong;Park, Sung-Wook;Jung, Woo-Sang;Moon, Sang-Kwan;Park, Jung-Mi;Ko, Chang-Nam;Cho, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Sang-Hoon;Bae, Young-Min
    • The Journal of Korean Medicine
    • /
    • v.32 no.5
    • /
    • pp.50-65
    • /
    • 2011
  • Objectives: Moxibustion has been used for various post-stroke symptoms and has also been known to have effect on peripheral blood flow. This study investigated the effect of moxibustion on radial artery blood flow by Doppler ultrasound and on heart rate variability in post-stroke hemiplegia patients. Methods: Moxibustion was applied on the points of LI4, TE3, TE5 and LI11 on the affected side, and blood flow of the radial artery was measured using the Minimax-Doppler-K device. Blood flow velocity and pulsation index were analyzed before, during, and after moxibustion. Simultaneously LF, HF, and LF/HF as variables for HRV were measured by FM-150. Results: The mean value of blood flow velocity in all patients (n=23) showed significant increase between before and after moxibustion, but there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. In Yin (n=9) and Yang (n=14) groups, both showed significant increase of blood flow velocity between before and after moxibustion, but there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. In Deficiency (n=14) and Fullness (n=9) groups, only the Deficiency group showed significant increase of blood flow velocity between before and after moxibustion, while the Fullness group showed no significant difference in blood flow velocity between before and after moxibustion, and also there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. Conclusions: This study suggests that moxibustion on LI4, TE3, TE5 and LI11 on the affected side of stroke patients increase the peripheral blood flow in the affected arm, which was most remarkable in those with Yin and Deficiency pattern.