• 제목/요약/키워드: blood parameter

검색결과 310건 처리시간 0.036초

대사판정시험을 이용한 젖소의 우유증산 (Production Increase of Milk in Dairy Cow by Metabolic Profile Test)

  • 이창우;김본원;라정찬;신상태;김두;김종택;홍순일
    • 한국임상수의학회지
    • /
    • 제10권1호
    • /
    • pp.65-94
    • /
    • 1993
  • This study examined metabolic profiles of 1349 Holstein cows from 91 commercial herds. Thirteen parameters which are consisted of twelve blood components and body condition score were examined and their mean values. standard deviations and standard limits, which are 80% confidential limits, in each lactational stage were reported. The variations of each parameter affected by season, individual milk yield, adjusted corrected milk yield of herd. and lactation number were also reported. A model of metabolic profile test applicable to this country where the average number of cows in a herd is small as to be fifteen is designed. Metabolic profiles as reflected in each parameter were discussed in relation to adequacy of dietary intake for production, milk production, reproductive performance, and diseases, and the possible measure to improve productivity of dairy cows were proposed. Much of the variation in parameters was due to differences between herds, and less to differences between seasons, differences between individual milk yield, and differences between lactational stages. As the average herd size in this country is small, it is believed that all the cows in a herd must be sampled, and the individual result of each parameter was compared with the standard limit for each lactational stage, and the percentage of cows which are outside the standard limits in a herd was calculated to use as a criteria for evaluation of the herd. Data outside the 99% confidential limits were to be deleted at first, but when the trends of the data outside the 99% confidential limits are same as the trends of the data within 99% confidential limits, the deleted data must be reviewed again, otherwise some important informations would be missed. The mean concentration of blood urea nitrogen in this study was much higher than that was reported in England, U.S.A. and Japan, and it was similar to the upper limits reported in England, U.S.A. and Japan. So it was thought that the concentration of blood urea nitrogen is improper as a criteria for protein intake. The increase of serum total protein cocentration beyond standard limits was due to increase of serum globulin concentration in most of the cows. The correlation coefficient between serum and protein and serum globulin concentration was 0.83. Serum globulin concentration was negatively related to adjusted corrected milk of herd. Serum albumin, calcium and magnessium concentrations were negatively related to adjusted corrected milk of herd, which indicate that high-producing individual or high-producing herd have not taken sufficient protein/amino acids, calcium and magnessium. Packed cell volume was negatively related to adjusted corrected milk of the herd, and the trend was same In each lactational stage. The correlation coefficient between serum and packed cell volume was 0.16 and the correlation was very weak. Blood glucose concentration was lowest in early lactational stage, which indicates negative energy balance in early lactational stage. Blood glucose concentration was negatively related to adjusted corrected milk of herd from peak to late lactational stage, which indicates negative energy balance during the period in high-producing individuals or high-producing herds. Correlation coefficient between serum aspartate aminotransferase activity and serum ${\gamma}$-glutamyltransferase activity was 0.41, and this indicates that serum ${\gamma}$-glutamyltransferase should be included as a parameter of metabolic profile test to evaluate liver function. Body condition score of dairy cows in this country was lower than that of Japan in every lactational stages, and the magnitude of increase in body condition score during middle and late lactational stages was small. Metabolic profile can not be evaluated with solely nutritional intake. When an individual or large percentage of cows in a herd have adnormal values In parameters of metabolic profile test, veterinary clinician and nutritionist should cooperate so as to diagnose diseases and to calculate the e of no운ents simultaneously.

  • PDF

비선형 폐 가스 결합특성의 전기적 모델화 (Electrical Modelling of Nonlinear Blood-Gas Reaction)

  • 이준탁;정형환
    • 한국의학물리학회지:의학물리
    • /
    • 제2권2호
    • /
    • pp.175-182
    • /
    • 1991
  • 본 논문은 인공폐의 설계및 임상진단을 위한 허파기능의 연구 및 호흡생리의 요체인 폐모세 혈관내 혈액의 Hb와 가스상 산소의 비선형 결합특성을 규명할 수 있는 새로운 산소포화 모델을 전기적 등가회로에 기초하여 유도하였다. 새로이 유도된 산소포화 모텔은 종래의 모델에 비해 훨씬 간단하고, 광범위한 pH 및 각 생리 parameter 등의 변동에도 정확히 적용될 수 있었을 뿐 아니라, 결합반응과 등가인 2단 및 4단 RC 전기적 등가회로의 Simulation 결과로 부터, Hb 와 산소의 비선형 결합특성은 2단계의 복합 반응으로 취급하는 것이 타당함을 확인하였다.

  • PDF

Alteration in Erythrocyte Deformability in Diabetes Mellitus

  • Shin, Se-Hyun;Singh, Megha
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권1호
    • /
    • pp.17-26
    • /
    • 2006
  • Diabetes mellitus (DM) is a metabolic disorder, characterized by varying or persistent hyperglycemia, which induces several changes in the erythrocyte membrane and its cytoplasm, leading to alteration in the deformability. Techniques applied to measure this are based on filtration of erythrocyte suspension through a membrane and to obtain diffraction pattern under sheared conditions. Ektacytometry requiring less quantity of blood with disposable flow chamber used to measure the deformability of erythrocytes obtained from patients with diabetes and also associated with nephropathy and retinopathy. A decreasing trend of deformability in these patients is observed. The shape parameter form factor, as determined by image processing procedure, increases with the increased of blood glucose levels and shows a pattern similar to filtration time of erythrocyte suspensions through cellulose membranes. Further work is suggested to detect micro-level changes in cell membrane in diabetic patients

  • PDF

심장운동부하 모델링과 의료장비 개발 (Modeling for the Work of Heart and Development of the WOH Medical device)

  • 노형운;서상호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.501-504
    • /
    • 2006
  • The estimation of the work of heart can be treated as one of the most important parameters for determining the amount of circulating blood needed for harmonious metabolism in the human body. By monitoring the work of heart, one can detect increased work load of heart and start the treatment at the early stage of CHF. Thus it is necessary to estimate the work of heart. The contractility of the left ventricle, the second important parameter for representing the motion of heart, can be estimated through information on the work of heart. In this study, the modified Windkessel model, which has been used for a measure of vascular hemodynamic impedance parameters, was adapted to estimate the work of heart.

  • PDF

실시간 디지털 사지 혈류량 측정기 개발 (Development of Real Time Digital Peripheral Plethysmography)

  • 김수찬;김덕원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.424-427
    • /
    • 1997
  • Electrical impedance plethysmography is still be one of the simplest and most convenient methods or non-invasive measurement of blood low, but it has the weak point can not do real-time measurement because of using chart-record or processing after receiving data from analog plethysmography through A/D converter. In this study. we developed hardware system composed of analog part which include auto-balancing circuit and calibration register and digital part which include 80C196KC, keypad, and LCD. we studied the algorithms or extracting parameter to calculate blood low and implemented it using general purpose micro controller.

  • PDF

링거액 주입시의 부피팽창 효과에 대한 모델링 (Modeling of Volume Expansion Effects During Infusion of Ringer's Solution)

  • 이은호;최규택;여영구
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1191-1196
    • /
    • 2006
  • In this work the kinetics of volume changes of fluid spaces associated with infusion of Ringer's solution are analyzed using the body fluid space model. During infusion of Ringer's solution, the human body is assumed to be characterized by the fluid space model into which fluid is fed and from which fluid is left. Various infusion types were tested to accommodate different medical situations. Volunteers were given Ringer's solution and the changes in blood hemoglobin were detected. From the comparison with experimental data, the single- and two-fluid space models were found to represent adequately the kinetics of human volume expansion during infusion of Ringer's solution.

Estimation of baroreflex sensitivity using pulse arrival time rather than systolic blood pressure measurement

  • Lee, Jong-Shill;Chee, Young-Joon
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권1호
    • /
    • pp.14-19
    • /
    • 2010
  • Baroreflex sensitivity (BRS) is a parameter of the cardiovascular system that is reflected in changes in pulse interval (PD and systolic blood pressure (SBP). BRS contains information about how the autonomic nervous system regulates hemodynamic homeostasis. Normally the beat-to-beat SBP measurement and the pulse interval measured from the electrocardiogram (ECG) are required to estimate the BRS. We investigated the possibility of measuring BRS in the absence of a beat-to-beat SBP measurement device. Pulse arrival time (PAT), defined as the time between the R-peak of the ECG and a single characteristic point on the pulse wave recorded from any arterial location was measured by photoplethysmography. By comparing the BRS obtained from conventional measurements with our method during controlled breathing, we confirmed again that PAT and SBP are closely correlated, with a correlation coefficient of -0.82 to -0.95. The coherence between SBP and PI at a respiration frequency of 0.07-0.12 Hz was similar to the coherence between PAT and PI. Although the ranges and units of measurement are different (ms/mmHg vs. ms/ms) for BRS measured conventionally and by our method, the correlation is very strong. Following further investigation under various conditions, BRS can be reliably estimated without the inconvenient and expensive beat-to-beat SBP measurement.

Continuous Blood Pressure Monitoring using Pulse Wave Transit Time

  • Jeong, Gu-Young;Yu, Kee-Ho;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.834-837
    • /
    • 2005
  • In this paper, we describe the method of non-invasive blood pressure measurement using pulse wave transit time(PWTT). PWTT is a new parameter involved with a vascular that can indicate the change of BP. PWTT is measured by continuous monitoring of ECG and pulse wave. No additional sensors or modules are required. In many cases, the change of PWTT correlates with the change of BP. We measure pulse wave using the photo plethysmograph(PPG) sensor in an earlobe and we measure ECG using the ECG monitoring device our made in the chest. The measurement device for detecting pulse wave consists of infrared LED for transmitted light illumination, pin photodiode as light detector, amplifier and filter. We composed 0.5Hz high pass, 60Hz notch and 10Hz low pass filter. ECG measurement device consists of multiplexer, amplifier, filter, micro-controller and RF module. After amplification and filtering, ECG signal and pulse wave is fed through micro-controller. We performed the initial work towards the development of ambulatory BP monitoring system using PWTT. An earlobe is suitable place to measure PPG signal without the restraint in daily work. From the results, we can know that the dependence of PWTT on BP is almost linear and it is possible to monitoring an individual BP continuously after the individual calibration.

  • PDF

The correlation of blood pressure with height and weight in Korean adolescents aged 10-19 years; The Korean National Health and Nutrition Examination Surveys (2009-2011)

  • Song, Young-Hwan
    • Clinical and Experimental Pediatrics
    • /
    • 제57권1호
    • /
    • pp.35-40
    • /
    • 2014
  • Purpose: Height-specific blood pressure (BP) is the standard parameter used to diagnose childhood hypertension. However, there has been some argument that weight may be a better variable than height in the reference BP standards. Therefore, before assessing the BP status using the reference BP standards, a basic understanding of the fundamental association of weight and height with BP is required. Methods: In the present study, we analyzed the correlation of BP with height and weight in Korean adolescents (age, 10-19 years), using data from the Korean National Health and Nutrition Examination Surveys (2009-2011). Results: Systolic BP (SBP) was more closely correlated with weight than with height in the normal weight (body mass index [BMI], ${\leq}85th$ percentile) and overweight (BMI, >85th percentile) groups and in the normal waist circumference (WC, ${\leq}90th$ percentile) and high WC (>90th percentile) groups in both sexes. Diastolic BP (DBP) had a higher correlation with height than with weight in the normal weight and normal WC groups, whereas weight was more closely associated with DBP than height in the overweight and high WC groups in both boys and girls. Conclusion: In Korean adolescents, weight had a greater effect on SBP than height in both the normal weight and overweight groups. DBP was mainly affected by height in the normal weight group, whereas weight was the major determinant of DBP in the overweight group. Therefore, it may be necessary to consider weight in the establishment of reference BP standards.

STUDIES ON POTASSIUM-LYSINE INTERRELATIONSHIPS IN BROILER CHICKS 2. EFFECT OF POTASSIUM-LYSINE INTERRELATIONSHIPS ON BLOOD PARAMETER, SERUM AND BONE COMPOSITION

  • Shin, H.Y.;Han, I.K.;Choi, Y.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권1호
    • /
    • pp.145-150
    • /
    • 1992
  • To determine the effect of dietary potassium and lysine levels on blood parameters, serum and bone composition, 360 male broiler chicks of 3 days of age were used in a completely randomized $3{\times}3$ factorial experiment for 6 weeks. Experimental diets contained three supplemented levels of dietary potassium (0.3, 0.6 and 1.2%) and three supplemented levels of dietary lysine (0.6, 1.2 and 2.4%). Dietary levels of potassium and lysine did not influence blood pH, $pCO_2$, $pO_2$, $HCO_3$ and total $CO_2$ and interaction between potassium and lysine was not shown (p > 0.05). Serum lysine and arginine contents were significantly different by the levels of dietary lysine (p < 0.05). Lysine-arginine antagonism was observed in high lysine diet. But increasing dietary potassium did not alleviated the lysine-arginine antagonism. Serum sodium, potassium and chloride were not affected by dietary potassium and lysine levels (p > 0.05). Femur weight, length and P contents were affected by the levels of dietary lysine (p < 0.01). But no difference was observed in femur ash and Ca contents (p > 0.05). Interaction between potassium and lysine was shown in ash and P contents (p < 0.01).