• Title/Summary/Keyword: blood flow velocity

Search Result 286, Processing Time 0.029 seconds

Changes of Blood Flow Characteristics due to Catheter Obstruction during the Coronary Angioplasty

  • Suh, Sang-Ho;Roh, Hyung-Woon;Kwon, Hyuck-Moon;Lee, Byoung-Kwon
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.1
    • /
    • pp.25-30
    • /
    • 2004
  • Catheters are used to measure translesional pressure gradients in the stenosed coronary arteries. Uses of catheters during coronary angioplasty cause flow obstructions. A narrowed flow cross section with catheter effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angiplasty. Catheters in blood vessels cause pressure gradient rise and blood flow drop during the measurements. In this study, three dimensional computer simulations are conducted to investigate the flow blockage effects due to the catheter obstructions during the coronary angioplasty. The computer simulation models are generated by the data, which are measured by coronary angiogram, and the blood is treated as non-Newtonian fluid. The velocity, pressure, and wall shear stress variations are observed for the estimate of damages of blood vessel. This study is also extended to investigate the effects of stenotic vessel size, and shape and catheter size and location.

  • PDF

Effects of Pressurization on Finger's Blood Velocity of Tendon and Muscle Areas in Forearm of 20's male (20대 남성의 아래팔 손목 건영역과 근육영역 가압이 손가락 혈류속도에 미치는 효과)

  • Kim, Nam Yim;Hong, Kyunghi
    • Fashion & Textile Research Journal
    • /
    • v.21 no.4
    • /
    • pp.488-496
    • /
    • 2019
  • This study investigated if the proper pressure level on the wrist tendon area and muscle area of the lower arm are within the same range by examining the responses of blood flow and subjective evaluation. Subjects consisted of 18 males in their 20s, and the experimental bands were custom-made by applying size measurements of each subject. In the experiment, a total of 5 steps were selected by reducing 10 (Step 1) to 50 (Step 5)% from the original body size in the circumferential direction. Blood flow was measured with a sensor attached to the tip of the finger inside the right hand while sitting in a chair for 15 minutes. Blood velocity began to increase (0.82 kPa) when the wrist circumference around tendon area was reduced by 20% (Step 2) and reached its maximum (1.72 kPa) at Step 4. However, the preferred subjective pressure was 1.36 kPa, which was less than the maximum pressure value of 1.72 kPa for Step 4. Blood velocity began to increase when pressure on the muscle area was 1.38 kPa and reached its maximum at 2.16 kPa; however, the most preferred clothing pressure was 1.71 kPa. The results of this study showed that the appropriate pressure level was higher in the muscle area than in the wrist tendon of the lower arm and indicated that graduated compression is favorable.

Effect of body acceleration on pulsatile flow of Casson fluid through a mild stenosed artery

  • Nagarani, P.;Sarojamma, G.
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.4
    • /
    • pp.189-196
    • /
    • 2008
  • The pulsatile flow of blood through a stenosed artery under the influence of external periodic body acceleration is studied. The effect of non-Newtonian nature of blood in small blood vessels has been taken into account by modeling blood as a Casson fluid. The non-linear coupled equations governing the flow are solved using perturbation analysis assuming that the Womersley frequency parameter is small which is valid for physiological situations in small blood vessels. The effect of pulsatility, stenosis, body acceleration, yield stress of the fluid and pressure gradient on the yield plane locations, velocity distribution, flow rate, shear stress and frictional resistance are investigated. It is noticed that the effect of yield stress and stenosis is to reduce flow rate and increase flow resistance. The impact of body acceleration is to enhance the flow rate and reduces resistance to flow.

Evaluation of Cerebrovascular Reactivity According to Age Using Transcranial Doppler (Transcranial Doppler를 이용한 연령에 따른 뇌혈관 반응성 평가)

  • Lee, Gyu Taek;Kim, Jong Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.43-48
    • /
    • 2004
  • Cerebral vasoreactivity is an index of autoregulation of cerebral perfusion, and can be measured using functional images such as Xe CT, SPECT and PET in reponse to hypercapneic stimulus. In order to measure cerebral $CO_2$ vasoreactivity in routine TCD study conveniently and reliably, we devised a method of rebreathing into closed volume of reservoir bag as a hypercapneic stimulus, and applied it to 44 healthy volunteers. As a hypercapneic stimulus, we applied fitting mask connected with closed reservoir bag for about 90 seconds, and mean blood flow velocity(MBFV) and pulsatility index(PI) were evaluated at proximal middle cerebral arteries(MCA) of 50-55 mm depth, before and after the hypercapneic stimulus. Age affected the MFV and PI value showed significant and the MFV was 56.45(SD=9.75)cm/sec, while PI was 0.406(SD=0.089). As age increases the flow velocity decreased significantly whereas PI value increased(P<0.05). The vasoreactvity significantly decreased with age(P<0.05). The decrease of cerebral blood flow quantity and cerebral blood flow velocity is not only because of increase of diameter of cerebrovascular resulting from aging, but the resistance increase of small blood vessel resulting from the increase of PI & RI value is regarded. We suppose that the rebreathing method is a reliable and convenient technique as a hypercapneic stimulus in determining cerebral $CO_2$ vasoreactivity. The rebreathing method could be non-invasive and useful methods in estimation of the cerebrovascular reactivity and could be applied to the basal and follow-up evaluation of the cerebrovascular reserve of the ischemic stroke patients.

  • PDF

A Study on the Multigate Pulsed Doppler System. (다중 채널 펄스 도플러 장치에 관한 연구)

  • 김병철;박세현
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.75-79
    • /
    • 1986
  • In this paper, a multigate pulsed doppler system with parallel signal processing which enables the transcutaneous assesment of the blood-flow velocities of five adjacent sample volumes is developed. The outputs of the system are audio signals, velocity curves and velocity profiles of 5 adjacent sample volumes. We have applied to the major superficial arteries and obtained the detailed information about the time dependent blood-flow behavior.

  • PDF

Experimental research on blood sucking phenomena of a female mosquito (암모기 흡혈과정에 대한 실험적 연구)

  • Kim, Bo-Heum;Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.105-106
    • /
    • 2008
  • As a carrier of malaria and sneak of blood, mosquitoes are an unpleasant insect. However, there are several unknown natural secretes related with mosquitoes. Among them, we focused on the blood sucking process of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism that can be used to resolve the problem encountered in the injection or transport of infinitesimal biological fluids in a micro-chip. At first, the velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) technique. The velocity signals of flow in the proboscis show periodic variation. This seems to be resulted from the beating of the pharyngeal pump which works as driving power. To analyze the pumping mechanism, the temporal variation of the pharyngeal pump was visualized using the synchrotron X-ray micro-imaging technique. The volume variation was estimated by the help of digital image processing techniques. Once the main mechanism of blood sucking process was found, a effective micro-pumping system with high efficiency would be developed in near future.

  • PDF

A NUMERICAL ANALYSIS ON BLOOD FLOOD FLOW INSIDE A CAROTID ARTERY WITH THE PATIENT SPECIFIC ARTERIAL GEOMETRY AND BLOOD RHEOLOGY DATA (실제 혈관 형상 및 혈액 특성을 고려한 경동맥 내 혈액 유동에 대한 수치해석 연구)

  • Lee, Sang-Hyuk;Jeong, Seul-Ki;Hur, Nahm-Keon;Cho, Young-Il
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.224-227
    • /
    • 2010
  • In the present study, the characteristics of blood flow inside a carotid artery numerically investigated with shear rate specific blood viscosity. To simulate the blood flow with a patient-specific arterial geometry, the geometry of a carotid artery was constructed from 2D rain MRA data. The measured data of blood flow velocity at the common carotid artery were used as boundary conditions of the simulation. For the blood rheology data to be used in the simulation, the patient specific blood viscosity over the whole ranges of shear rate was obtained using $BioVisco^{TM}$. From the numerical results of the blood flow in the carotid artery, the increase of blood viscosity and the decrease of wall shear stress could be found in the carotid bifurcated region, more specifically at the post-plaque dilated region. These characteristics of blood viscosity and wall shear stress can be used more precisely and efficiently to predict the region vulnerable to plaque growht or thrombosis on top of the plaque.

  • PDF

Comparison of Steady and Physiological Blood Flow Characteristics in the Left Coronary Artery Bifurcation (좌관상동맥 분지부내의 정상혈류와 박동성혈류의 유동특성비교)

  • Suh, S.;Yoo, S.S.;Kwon, H.M.;Roh, H.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.57-60
    • /
    • 1995
  • The objective of this investigation is to understand the role of hemodynamics in the formation and development of atherosclerosis lesions in the human left coronary artery This study also aims to compare the blood flow characteristics of steady and physiological flows. Three dimensional, steady and physiological flows of blood in the left coronary artery are simulated using the Finite Volume Method. Apparent viscosity of blood is represented as a function of shear rate by the Carreau model. Distributions of velocity, pressure and shear stress in tile left coronary artery bifurcation are presented to compare tile steady and physiological flow characteristics.

  • PDF

Effect of Paekoe(GV20) Acupuncture on Cerebral Blood Flow (백회혈 자침이 뇌혈류에 미치는 영향)

  • Lee Hong-Min;Cheong Byung-Shik;Yun Hyoung-Seok;Cho Seong-Gyu;Lee Sang-Hoon;Jun Hyung-Joon;Nam Sang-Soo;Kim Yong-Suk;Lee Joo-Hyung
    • Journal of Acupuncture Research
    • /
    • v.18 no.6
    • /
    • pp.105-113
    • /
    • 2001
  • Objective : This study was performed to evaluate the effect of acupuncture on cerebral blood flow by Transcranial Doppler Ultrasonography(TCD) Method : Monitoring of TCD was examined in 11 healthy women volunteer(mean $age:\;24.5{\pm}2.9\;\;years$) before, during and after acupuncture on Paekoe(GV20). Mean velocity, pulsatility index, systolic velocity and diastolic velocity values are analyzed from DWL. MDX4 at different depths of both middle cerebral artery. Results : The results showed a significant(p<0.05; Friedman test & Wilcoxon signed ranks test) increase in mean velocity, systolic velocity and diastolic velocity decrease in pulsatility index, which was measured at different depths of both middle cerebral artery. Conclusion : These results suggest that acupuncture could have a specific effect on cerebral blood flow.

  • PDF

Visualization of blood sucking phenomena of a female mosquito (암 모기 흡혈과정 가시화)

  • Kim, Bo-Heum;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.114-115
    • /
    • 2007
  • As a carrier of malaria and sneak of blood, mosquitoes are regarded as an unpleasant insect. However, there are novel phenomena that happen inside a mosquito. Among them, we focused on the blood sucking function of a female mosquito. The main objective of this study was to investigate the mosquito's pumping mechanism in order to resolve the problem encountered when we inject or transport biologic fluids into a micro-chip. To analyze the pumping mechanism, we visualized the blood sucking process inside a female mosquito. Flow characteristics of blood flow in a proboscis were investigated experimentally using a micro-PIV velocity field measurement technique. The anatomical variation of head, thorax, abdomen which work as pumps and valves, was visualized using the syncrotron X-ray micro-imaging technique.

  • PDF