• Title/Summary/Keyword: blood flow velocity

Search Result 288, Processing Time 0.034 seconds

Changes of Blood Flow Characteristics for different Coil Locations after the Embolisation of Lateral Aneurysms (측방 동맥류 색전술 후 코일 위치에 따른 혈류 유동의 변화)

  • 이계한;송계웅;변홍식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.124-127
    • /
    • 2002
  • Ceil embolisation technique has been used to treat the intracranial aneurysms. Microcoils inserted into the aneurysm sac induce the blood flow stagnation inside the aneurysm sac, which causes the thrombus formation and embolisation of aneurysm. Since the intraaneurysmal flow patterns affect the embolisation process, we want to measure the flow field for different locations of coil inside the aneurysm sac . Lateral aneurysm models are manufactured using rapid prototyping, and the velocity fields are measured using particle image velocitimeter. Distally blocked models showed less flow into the aneurysm sac comparing to proximally blocked models. Also blocking the neck of aneurysm showed better inflow blocking comparing to blocking the dome of aneurysm. These results suggest that distal neck should be the preferred locations of coil for aneurysm embolisation.

  • PDF

Comparison of Correlation Coefficients and Intraclass Correlation Coefficients Between Two-way FSI Flow Velocity of Simulated Abdominal Aorta and Human 4D Flow MRI Flow Velocity (시뮬레이션 복부 대동맥의 양방향 FSI 유속과 인체 4D flow MRI 유속의 상관계수, 급내상관계수 비교)

  • Ahn, Hae Nam;Kim, Jung Hun;Park, Ji eun;Choi, Hyeun Woo;Lee, Jong Min
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.143-149
    • /
    • 2021
  • In order to predict and prevent the disease of the abdominal aorta, which is the largest artery in the human body and the most common aneurysm, the normal arterial blood flow operation should be considered. To this end, we are trying to solve problems that may arise in the future by executing FSI based on the data obtained from 4D flow MRI. However, to match the similarity between the 4D flow MRI flow and the FSI flow, correlation was used in previous papers, but the correlation did not show the degree of agreement. Therefore, in this paper, we analyzed the correlation between the 4D flow MRI flow velocity of the human abdominal aorta and the two-way FSI flow velocity in which the three physical properties used for the aortic FSI were added to the CT abdominal aorta 3D model and the interclass correlation coefficient. As a result, the physical property M2 showed the highest similarity in correlation and intraclass correlation coefficient, and this property is intended to be helpful in the future study of the abdominal aortic two-way FSI flow rate.

The Effects of Panax ginseng and P. quinquefolium on Hemodynamics and Body Temperature in Healthy Young Men (II)

  • Lee, Jee-Hwan;Cho, Jung-Ah;Ki, Chan-Young;Son, Yeon-Kyoung;Park, Jeong-Hill;Park, Man-Ki;Han, Yong-Nam
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.318-318
    • /
    • 2003
  • The current study was performed to observe the effects of Panax ginseng (PG) and P. quinquefolium (PQ) on hemodynamics such as blood flow rate (BF), blood flow velocity (BV), heart rate (HR), systolic blood pressure (SBP), and diastolic blood pressure (DBP) and body temperature (BT) in healthy young men. This is a randomized, single-blind study observed during 6 hrs after orally single administration of PG and PQ groups. (omitted)

  • PDF

APPLICATION OF ADOMIAN'S APPROXIMATION TO BLOOD FLOW THROUGH ARTERIES IN THE PRESENCE OF A MAGNETIC FIELD

  • Haldar, K.
    • Journal of applied mathematics & informatics
    • /
    • v.12 no.1_2
    • /
    • pp.267-279
    • /
    • 2003
  • The present investigation deals with the application of Adomian's decomposition method to blood flow through a constricted artery in the presence of an external transverse magnetic field which is applied uniformly. The blood flowing through the tube is assumed to be Newtonian in character. The expressions for the two-term approximation to the solution of stream function, axial velocity component and wall shear stress are obtained in this analysis. The numerical solutions of the wall shear stress for different values of Reynold number and Hartmann number are shown graphically. The solution of this theoretical result for a particular Hart-mann number is compared with the integral method solution of Morgan and Young[17].

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

A New Scale(NS) Score System to Predict Outcome of Intracranial Aneurysm Using TCD (TCD를 이용한 두개강내 동맥류의 예후 예측 가능한 New Scale(NS) Score System)

  • Park, Sang Hoon;Park, Chong Oon;Park, Hyeon Seon;Hyun, Dong Keun;Ha, Young Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.8
    • /
    • pp.970-975
    • /
    • 2001
  • Objective : By conducing a review of clinical outcomes for patients with aneurysm treated using current microneurosurgical techniques and intensive care unit management, we speculated that grading systems based only on clinical condition or CT finding after admission failed to provide a significant stratification of outcome between individual grades of patients, because these systems did not include the factor for postoperative vasospasm. We hypothesized that postoperative blood flow velocity could have a significant impact on outcome prediction for patients surgically treated for intracranial aneurysms. Methods : We conducted a analysis on patient- and lesion-specific factors that might have been associated with outcome in a series of 55 aneurysm operations performed with measurements of blood-flow velocity with transcranial Doppler ultrasonography(TCD). In the new scale(NS) score system, 1 point is assigned additionally for the case with Hunt and Hess(H-H)/World Federation of Neurological Surgeons(WFNS) Grade IV or V, Fisher Scale(FS) score 3 or 4, aneurysm size greater than 10mm, patient age older than 60 years, blood-flow velocity higher than 120cm/sec, and posterior circulation lesion. By adding the total points, a 6-point scale score(score 0-6) is obtained. Results : Age of patient, size of aneurysm, clinical condition(H-H grade and WFNS), FS score, and blood flow velocity(TCD 1day after operation) were independently and strongly associated with long-term outcome. When NS scores were applied to 55 patients with at least 6 months follow-up, the correlation of individual scores with outcome was strongly validated the retrospective findings. Conclusion : It was speculated that TCD could be used to assess postoperative vasospasm and to monitor noninvasively the patients with aneurysmal SAH. This NS score system is easy to apply, divide patients into groups with different outcome, and is comprehensive, allowing for more accurate prediction of surgical outcome.

  • PDF

Analysis of Changes in Carotid Intima-media Thicknesses according to Metabolic Syndrome-inducing Factors (대사증후군 유발 인자에 따른 경동맥 내중막 두께의 변화 분석)

  • Nan-Hee An;Tae-Jeong Ji;Hyeon-Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.597-606
    • /
    • 2023
  • This study retrospectively analyzed the test results of 235 patients who visited a medical institution in Busan from May 2022 and February 2023 and conducted both carotid ultrasonography and blood tests. The purpose of this study was to investigate the effect on intima-media thickness and blood flow velocity by measuring the intima-media thickness and blood flow velocity through carotid ultrasonography and analyzing the factors influencing the subject's body mass index and metabolic syndrome. Correlation analysis between carotid intima-media thickness and body mass showed (p=0.000) confirming that there is a correlation. As a result Correlation analysis between blood flow velocity and body mass index (p=0.015) was found, comfirming that there was a correlation. Age (p= 0.000), fasting blood glucose (p=0.002) and alcohol consumption (p=0.006) were found to be correlated with carotid intima-media thickness. An increase in Carotid intima-media thicknesses causes an increase in events caused by cardiovascular disease. Therefore, efforts must be made to exclude factors that increase Carotid intima-media thicknesses, and it will be most important to prevent cardiovascular disease through research on various prediction methods and regular checkups.

Flow Analysis of Resin in an Extrusion Die for the Production of Medical Catheter Tubes (의료용 카테타 튜빙의 압출을 위한 다이내의 수지 흐름해석)

  • Lee, M.A.;Lyu, M.-Y.;Shin, D.J.;Kim, T.K.
    • Transactions of Materials Processing
    • /
    • v.24 no.2
    • /
    • pp.89-94
    • /
    • 2015
  • Medical catheter tubes are disposable devices that are inserted into the body cavities such as the pleura, trachea, esophagus, stomach, urinary bladder, ureter, or blood vessels for surgical procedures. Each hole of the inner tube is called a lumen, which is used as a passage for drug injections, waste discharge, polypus removal, blood transport, or injection of a camera or sensor. The catheter tube is manufactured by extrusion. The flow in the inner extrusion die affects the thickness and diameter of the tube. In the current study computer simulation of flow in an extrusion die for catheter tubing was performed. Velocity, pressure, shear rate, and shear stress were investigated and the die design was examined.

Manual of Transcranial Doppler Ultrasonography (경두개 도플러 초음파 검사 지침서)

  • Ho Tae JEONG;Soo Na JEON;Sol HAN
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.3
    • /
    • pp.277-287
    • /
    • 2024
  • Transcranial Doppler (TCD) ultrasound is a crucial non-invasive tool for assessing cerebral blood flow and is widely used to diagnose and monitor cerebrovascular diseases. This paper reaffirms the importance of TCD, details examination methods and precautions, and provides a guide for practitioners. TCD evaluates the blood flow velocity to assess stenosis, occlusion, and hemodynamic changes. Distinguishing between increased blood flow volume and decreased vessel diameter based solely on velocity is challenging, necessitating a comprehensive approach to integrating clinical findings and hemodynamic changes. The reliability of TCD results depends on the skill of the examiner and requires standardized procedures and continuous training. Advances in automation and artificial intelligence promise enhanced accuracy and reliability. Future research should focus on validating and clinically applying these technologies. This paper is a review of the clinical significance of TCD, methods, and precautions, offering a valuable guide for practitioners and highlighting the potential benefits of ongoing advancements in TCD for the diagnosis and treatment of cerebrovascular diseases.

Clothing Pressure, Blood Flow, and Subjective Sensations of Women in Their 50s and 60s When Wearing a Commercial Yoga Bra Top (시판 요가용 브라탑 착용 시 50~60대 여성의 의복압 및 혈류와 주관적 반응)

  • Park, Soyoung;Kim, Namyim;Hong, Kyunghi;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.4
    • /
    • pp.586-597
    • /
    • 2021
  • This study analyzed clothing pressure, blood flow, and subjective sensations among women in their 50s and 60s while wearing commercially available yoga bra tops (YBTs). These findings could then serve as basic data for designing YBT for women in this age range. Clothing pressure and blood flow reactions were measured in seven participants wearing four commercially available YBTs. Subjective sensations of pressure and comfort were also evaluated. The calculated data were analyzed using the SPSS 24.0 statistical program. The results suggested that YBT4 exerted the lowest clothing pressure, while YBT2 and YBT3 exerted relatively higher clothing pressures. Participants' blood flow decreased while wearing YBTs compared to the control garment. The decrease of 47.3% when the participants wore YBT2 was especially significant. The results confirmed that the blood velocity rate was physiologically lower while wearing all four YBTs than when wearing the control garment. Results for subjective pressure and overall comfort confirmed that YBT2 and YBT3 exerted relatively high pressure, while YBT4 did not exert pressure.