• Title/Summary/Keyword: blood exchange

Search Result 170, Processing Time 0.023 seconds

Effect of Ionic Polymers on Sodium Intake Reduction (이온성 고분자를 이용한 나트륨 섭취 감소 효과)

  • Park, Sehyun;Lee, YoungJoo;Lee, Jonghwi
    • Polymer(Korea)
    • /
    • v.37 no.4
    • /
    • pp.533-538
    • /
    • 2013
  • Sodium chloride is present in our body fluids, and the blood contains approximately 0.9 wt% salt, which plays an important role in maintaining the osmotic pressure. However, the amount of salt intake has consistently increased, and an excessive intake can be the cause of high blood pressure, etc. In this study, it was investigated in vivo and in vitro whether biocompatible ionic polymers with K or Ca ions can be replaced by Na ions through an ion exchange process to be excreted. Among the polymers, Ca-polystyrene sulfonate, K-polystyrene sulfonate, Ca-carrageenan, and Ca-tamarind had an excellent Na exchange ability in the body temperature, simulated gastric fluid and also simulated intestinal fluid. The mechanism of Na removal by absorption and excretion without changing food taste in the mouth through the insolubility properties of these polymers is expected to be a solution for the current problems related with excess sodium intake.

Development of an Ubiquitous Healthcare System based on Health Information Exchange Standards (건강정보 교환 표준에 기반한 유비쿼터스 헬스케어 시스템 개발)

  • Lee, In-Keun;Kim, Hwa-Sun;Cho, Hune
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.273-280
    • /
    • 2012
  • As changed the clinical environment, the interest on u-Healthcare service and systems has been increased. The ubiquitous healthcare(u-Healthcare) systems are constructed at the integrated environment that consists of various devices and systems basically such as personal health devices(PHDs) measuring body signals, information aggregators gathering the data transmitted from PHDs through wireless technology, and health information systems storing and managing personal health information transmitted from the information aggregators. International standards such as IEEE 11073 and HL7 have been specified for the interoperability of PHDs and health information systems, but the research on u-Healthcare systems that were developed and applied in the real clinical environment by adopting the standards was rarely conducted. Therefore, we developed an u-Healthcare system which can manage personal health information, such as blood glucose, blood pressure, and body composition, based on health information exchange standards. Moreover, we verified the stability of the developed system through clinical trial in patients with endocrine disease at the Kyungpook National University Hospital, and listed problems occurred during clinical trial and found their solutions.

Relationships between arterial and urinary $P_CO_2}, P{O_2}$ and acid-base balances (동맥혈 및 뇨 $P_CO_2}, P{O_2}$ 의 산-염기 균형 및 뇨량과의 관계)

  • Kim, Yong-Jin;Lee, Yeong-Gyun
    • Journal of Chest Surgery
    • /
    • v.16 no.2
    • /
    • pp.213-220
    • /
    • 1983
  • Pulmonary function is the determinant of blood gas tension. However, Acid-Base disturbances can also alter partial pressures of oxygen and carbon dioxide in arterial blood. During respiratory acidosis $PO_2$ will be lowered and reverse changes will be produced during respiratory alkalosis. On the other hand, in metabolic acidosis $PO_2$ will be elevated and $PCO_2$ will be lowered by the respiratory compensation, and reverse response will be induced in metabolic alkalosis. Urinary gas tension has many influencing factors than arterial blood and difficult to estimate the tendency of its alterations. Urinary $PO_2$ and $PCO_2$ are not always identical level as venous blood. It is to be altered by blood gas tension, flow rate of urine, metabolic rate of kidney, and Acid-Base status of blood. Particularly countercurrent exchange of oxygen and carbon dioxide in the renal medulla will make larger alteration of gas tension than venous blood. After induction of Acid-Base disturbances [disturbances] arterial and urinary $PCO_2$, $PO_2$, urinary volume, and osmolarity were determined in dogs, and the relationships between arterial and urinary $PCO_2$ , $PO_2$ Acid-Base disturbances, urinary volume, and osmolarity were investigated. 1. During the acute Metabolic and Respiratory disturbances urinary pH did not respond on respiratory origin. However, there were immediate urinary response in pH on metabolic origin. 2. Urinary $PO_2$, $PCO_2$, did not always follow arterial or venous gas tension and Acid-Base disturbance. Urinary $PCO_2$, correlate well with the urinary volume. The larger the urinary volume, $PCO_2$ lowered to the venous level. The smaller the urinary volume, urinary $PCO_2$ tends to be higher. However urinary $PO_2$ did not have any particular correlation with urinary volume. 3. Correlation between urinary $PCO_2$ and $PO_2$ were inversely proportional to arterial blood. Differences of $PCO_2$ between arterial blood and urine also did not have any particular correlation with urinary volume. This may suggest that changes on blood gas tensions can influence on urinary $PCO_2$. 4. There were eminent clear inverse correlation between urinary $PCO_2$ and osmolar concentrations of urine. Above results strongly suggest that partial pressure of gas in urine primarily depend upon counter-current exchanges in renal medullary tissues.

  • PDF

Concentration of PFOA and PFOS in Whole Blood and Factors Controlling Their Exposure Among Koreans (한국인의 혈 중 PFOA와 PFOS 농도와 노출요인)

  • Suh, Chun-Hui;Lee, Chae-Kwan;Lee, So-Ryong;Park, Mi-Hee;Lee, Jong-Tae;Son, Byung-Chul;Kim, Jeong-Ho;Kim, Kun-Hyung
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.105-117
    • /
    • 2012
  • Objectives: This study aimed to assess the concentration of perfluorooctanoic acid (PFOA) and perfluorooctanesulfonate (PFOS) in blood and factors controlling their exposure among Koreans. Methods: Study subjects were selected to include 718 members of the general population residing in five metropolitan cities and the Gangwon Province area from August 2008 to January 2009. A questionnaire was administered to investigate lifestyle, socio-demographic characteristics, and other related factors. Blood samples were collected and extracted using solid-phase extraction and anion-exchange methods, and quantified by high-performance liquid chromatograph (HPLC, Agilent 1200 Series) coupled with a Triple Quad LC-MS/MS system (Agilent 6410). Results: Geometric mean concentrations of PFOA and PFOS in the blood were measured as 1.82 and 6.06 ng/ml, respectively. Mean PFOA and PFOS concentrations generally increased with age in both genders. Blood PFOA concentration was significantly different according to such variables as age, family income, residential district, and province. Blood PFOS concentration was significantly different by such variables as gender, age, lifestyle factors such as regular exercise, alcohol consumption, and smoking status. Also, family income, hazardous facilities, job classification, and province contributed significantly to differences in blood PFOS concentration levels. Conclusions: Blood PFOA and PFOS concentrations in Koreans were similar with those found in Japan, the USA, and Germany, but less than those in Australia. PFOA and PFOS exposure seems to be affected by a variety of factors in Korea. Therefore, investigation is required for each factor to assess the relative contribution of different variables.

A Novel Anticoagulant Protein with High Affinity to Blood Coagulation Factor Va from Tegillarca granosa

  • Jung, Won-Kyo;Jo, Hee-Yeon;Qian, Zhong-Ji;Jeong, Young-Ju;Park, Sae-Gwang;Choi, Il-Whan;Kim, Se-Kwon
    • BMB Reports
    • /
    • v.40 no.5
    • /
    • pp.832-838
    • /
    • 2007
  • A novel inhibitory protein against blood coagulation factor Va (FVa) was purified from muscle protein of granulated ark (Tegillarca granosa, order Arcoida, marine bivalvia) by consecutive FPLC method using anion exchange and gel permeation chromatography. In the results of ESI-QTOF tandem mass analysis and database research, it was revealed that the purified T. granosa anticoagulant protein (TGAP) has 7.7 kDa of molecular mass and its partial sequence, HTHLQRAPHPNALGYHGK, has a high identity (64%) with serine/threonine kinase derived from Rhodopirellula baltica (order Planctomycetales, marine bacteria). TGAP could potently prolong thrombin time (TT), corresponding to inhibition of thrombin (FIIa) formation. Specific factor inhibitory assay showed that TGAP inhibits FVa among the major components of prothrombinase complex. In vitro assay for direct-binding affinity using surface plasmon resonance (SPR) spectrometer indicated that TGAP could be directly bound with FVa. In addition, the binding affinity of FVa to FII was decreased by addition of TGAP in dose-dependant manner ($IC_{50}$ value = 77.9 nM). These results illustrated that TGAP might interact with a heavy chain of FVa ($FVa_H$) bound to FII in prothrombin complex. The present study elucidated that non-cytotoxic T. granosa anticoagulant protein (TGAP) bound to FVa can prolong blood coagulation time by inhibiting conversion of FII to FIIa in blood coagulation cascade. In addition, TGAP did not significantly (P < 0.05) show fibrinolytic activity and cytotoxicity on venous endothelial cell line (ECV 304).

Changes in Physiological Responses by the Pressure of Non-Elastic Corset (비신축성 코르셋의 의복압으로 인한 생리적 반응의 변화)

  • Na, Young-Joo;Kim, Yang-Hee
    • Fashion & Textile Research Journal
    • /
    • v.13 no.6
    • /
    • pp.943-951
    • /
    • 2011
  • The purpose of this study is to analyze the physiological effects of non-elastic corset on women's health and pain through measuring the clothing pressure, subjective pressure sensation, blood velocity and metabolism. 5 women in their twenties were picked as our subjects, their average size being 85cm at bust girth, 69 cm at waist girth. With the subjects each wearing a corset, we are testing in artificial environment with a treadmill according to the planned exercise procedures. The average pressure of the corset is 0.938 kPa (maximum 3.006 kPa at 45 degree front bowing), which is 10.2 times higher than the control group, averaging from 9.3 times higher at resting, 11.4 times at walking, 11.1 times at running. The effect of corset pressure on the physiological responses of the body is increased more when exercise than when resting. Clothing pressure increased in the order of the postures: sitting > standing with 45 degree bowing > standing. They experienced a high level of tighten discomfort of 5.6 in the scale of 1.0 to 7.0 due to the high pressure of the corset when resting, after intense exercise the level increased to 6.0, while without corset the level increased 1.7 to 2.2. With corset on, the blood circulation did not increase even though when the body exercised and blood flow became unbalanced making great gaps between both at the right and left finger tips. Perspiration of chest and back decreased 37.3% when wearing corset; 27.5% at resting, 56.7% at walking, 25.8% at running, and 39.0% at recovery. With corset on oxygen consume and metabolism increased 9.0%, 7.9%, respectively, which means the corset makes the body uncomfortable. Lung volume exchange VE decreased almost 4.1~7.3% with corset on and $VCO_2/VO_2$, RER and total volume in lung, VT also decreased too, which means the digestion of stomach and lung function are inhibited due to the high corset pressure.

Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion (상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF

Purification of hemolysin in mosquitocidal delta-endotoxin from Bacillus thuringiensis subsp. darmstadiensis 73E10-2 (모기유충에 살충력이 있는 Bacillus thuringiensis subsp. darmstadiensis 73E10-2의 내독소의 용혈성 인자의 정제)

  • 김광현;이기희;홍용기
    • Microbiology and Biotechnology Letters
    • /
    • v.19 no.3
    • /
    • pp.303-307
    • /
    • 1991
  • The hemolyic polypeptide in delta-endotoxin from Bacillus thun'ngiensis subsp. darmstadiensis 73ElO-2 was purified by Sephadex G-IOO gel filtration and DEAE-cellulose ion exchange column chromatography. The purity of hemolysin was confirmed by ouchterlony test and SDS-PAGE. The molecular weight of the purified hemolysin was approximately 64 KDa by SDS-PAGE. The purified hemolysin has not mosquitocidal activity against larvae of Aedes agypti, but hemolytic activity on red blood cells of rat. There is no serological relationship between delta-endotoxin from B. thuringiensis subsp. israelensis and the purified hemolysin from the . strain 73ElO-2.

  • PDF

Engineering Education by Elliptical Trainers(ET) - Cardiorespiratory Responses by the Mean Free Path (Elliptical Trainers(ET)를 이용한 공학교육 - 평균자유거리에 의한 심폐기능의 반응)

  • Hwang, Un Hak
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.3 no.2
    • /
    • pp.53-62
    • /
    • 2011
  • The elliptical trainers(ET) can be a good tool for educating engineers by analyzing physical responses in terms of Respiratory Exchange Ratio (RER, epm) and Heart Rate (HR, bpm). For the various energy expenditure, exercise speed, and weight loss both RER and HR are studied in order to study the blood circulations based on the health training cardiorespiratory. As the results, (1) RER increases gradually as the energy expenditure, however, HR increases gradually up to a critical value and then increases rapidly. The critical value of the energy expenditure in our studies was 275 Cal. (2) RER increases gradually as the ET speed increases, however, HR increases gradually up to a critical value and then increases rapidly. The critical value of the ET speed in our studies was about 6.7km/h. (3) RER increases gradually as the weight loss increases (or, the metabolic cost increases), however, HR is almost nothing to do with the increase of the weight loss.

  • PDF

Analysis of selenoaminoacids and selenoproteins in blood serum of sows fed by selenium fortified feed (셀레늄강화 사료를 먹인 모돈 혈청에서의 셀레노아미노산 및 셀레노단백질 분석)

  • Park, Myungsoon;Lee, Sung Hoon;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.196-203
    • /
    • 2015
  • Selenium species (inorganic selenium, selenoaminoacids, and selenoproteins) were analyzed using anion exchange and affinity chromatography, which were connected to ICP/MS for the blood serum of sows fed by seleniumfortified feed. The Anion Exchange PRP X-100 column was used for the analysis of inorganic selenium (Se4+ and Se6+) and selenoaminoacids. The HEP column was used to separate SelP from GPx+SeAlb in selenoproteins. A quantitative analysis was performed using the post-column isotope dilution technique. The lactating sows were divided into three groups and fed by selenium fortified feed (organic 0.3 mg/kg, 0.6 mg/kg and inorganic 0.6 mg/kg) for four weeks. The test groups showed increases in selenoaminoacids compared with the control group, except the inorganic feed group. There was no significant difference between the organic feed groups. All test groups showed increases in selenoproteins. In particular, SelP showed a large increase that was 1.5 times higher than the other proteins.