• 제목/요약/키워드: blockage ratio

검색결과 119건 처리시간 0.028초

축류송풍기 부착형 공냉식 열교환기의 진동 저감 (Vibration Reduction of an Air Cooled Heat Exchanger with Axial Flow Fan)

  • 정구충;최연선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.75-81
    • /
    • 2000
  • Vibration problems induced by an air cooled heat exchanger with axial flow fan were investigated during the operation of a petrochemical plant. Two different studies were done; one was experimental field test and the other was theoretical verification. To find main cause of the blade passing frequency of the fan after installing additional blockage board at the air inlet of the axial fan, the frequency spectrum was measured. The vibrations of the blade passing frequency became higher. The natural frequency of driving support of the heat exchanger was theoretically calculated. It was approximately equal to the blade passing frequency. During the normal operation of the plant, it was impossible to modify the structure of the driving support. Instead, the blade number was increased to reduce vibration level. It increased the ratio of the forcing frequency to the natural frequency of the driving support over the resonance region.

  • PDF

고속 전철에 의한 터널 출구에서의 충격성 소음(소닉붐)의 예측 및 실험적 연구 (Measurement and prediction of sonic boom by high speed train at the tunnel exit)

  • 이수갑;윤태석;정원태;이동호;김동현;강신재
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.369-378
    • /
    • 1998
  • When a high-speed train enters a tunnel, a compression wave is generated ahead of the train and propagates along the tunnel. This wave subsequently emerges form the exit portal of the tunnel, which causes an impulsive noise. In the present study, experimental investigation is carried out on the sonic boom noise with parameters of train speed, blockage ratio, nose shape of train and airshaft. These experimental results show that several countermeasures could be used to efficiently reduce the sonic boom. In addition, numerical analysis is performed to predict the sonic boom. The predicted sound waves are in a good agreement with the experimental results.

  • PDF

급축소관을 전파하는 압축파에 관한 실험적 연구 (Experimental study on compression wave propagating in a sudden reduction duct)

  • 김희동
    • 대한기계학회논문집B
    • /
    • 제21권9호
    • /
    • pp.1139-1148
    • /
    • 1997
  • Compression waves propagating in a high-speed railway tunnel develops large pressure fluctuations on the train body or tunnel structures. The pressure fluctuations would cause an ear discomfort for the passengers and increase the aerodynamic resistance of trains. As a fundamental research to resolve the pressure wave phenomenon in the tunnel, experiments were carried out by using a shock tube with an open end. A blockage to model trains inside the tunnel was installed on the lower wall of shock tube, thus forming a sudden cross-sectional area reduction. The compression waves were obtained by the fast opening gate valve instead of a conventional diaphragm of shock tube and measured by the flush mounted pressure transducers with a high sensitivity. The experimental results were compared with the previous theoretical analyses. The results show that the ratio of the reflected to the incident compression wave at the sudden cross-sectional area reduction increases but the ratio of the passing to the incident compression wave decreases, as the incident compression wave becomes stronger. This experimental results are in good agreements with the previous theoretical ones. The maximum pressure gradient of the compression wave abruptly increases but the width of the wave front does not vary, as it passes over the sudden cross-sectional area reduction.

Visualization of Turbulent Flow Fields Around a Circular Cylinder at Reynolds Number 1.4×105 Using PIV

  • Jun-Hee Lee;Bu-Geun Paik;Seok-Kyu Cho;Jae-Hwan Jung
    • 한국해양공학회지
    • /
    • 제37권4호
    • /
    • pp.137-144
    • /
    • 2023
  • This study investigates the experimental parameters of particle image velocimetry (PIV) to enhance the measurement technique for turbulent flow fields around a circular cylinder at a Reynolds number (Re) of 1.4×105. At the Korea Research Institute of Ships & Ocean Engineering (KRISO), we utilized the cavitation tunnel and PIV system to capture the instantaneous flow fields and statistically obtained the mean flow fields. An aspect ratio and blockage ratio of 16.7% and 6.0%, respectively, were considered to minimize the tunnel wall effect on the cylinder wakes. The optimal values of the pulse time and the number of flow fields were determined by comparing the contours of mean streamlines, velocities, Reynolds shear stresses, and turbulent kinetic energy under their different values to ensure accurate and converged results. Based on the findings, we recommend a pulse time of 45 ㎲ corresponding to a particle moving time of 3-4 pixels, and at least 3,000 instantaneous flow fields to accurately obtain the mean flow fields. The results of the present study agree well with those of previous studies that examined the end of the subcritical flow regime.

도로터널 화재시 차량의 항력계수가 제연용 제연팬에 미치는 영향에 대한 해석적 연구 (A numerical study on effects of drag coefficient of vehicle on jet fans in case of fire in road tunnels)

  • 유용호;유지오;김효규
    • 한국터널지하공간학회 논문집
    • /
    • 제16권6호
    • /
    • pp.553-560
    • /
    • 2014
  • 도로터널에서는 환기 및 제연을 목적으로 제연펜을 설치하고 있다. 제연펜 용량(제트팬 댓수)은 환기저항 및 승압력이 평형이 되는 상태에서 결정되게 된다. 터널에 운행중이거나 정지된 차량에 의한 승압력 및 저항력은 차량의 항력계수에 영향을 받게 된다. 터널에서의 항력계수는 슬립스트림 효과(또는 shadow effect)와 폐색효과에 영향을 받게 되며, 환기팬 및 제연팬 산정시 이와 같은 효과를 적절히 고려하지 못하고 있는 실정으로 교통 환기력를 과대평가하고 있다. 이에 본 연구에서는 화재시 차량의 차간간격을 반영한 항력계수와 등가저항면적을 산정하기 위해서 터널에 실제로 차량이 정차하는 조건으로 모델링하여 수치해석을 통해 항력계수를 검토하였다. 본 연구 결과, 항력계수에 대형차량 혼입률이 미치는 영향은 명확하지 않으며, 등가저항면적은 현행 도로설계편람기준에 대비 약 86%, 또 구 기준인 한국도로공사 환기설계기준 대비 62.2%수준으로 감소하는 것으로 분석되었다.

Pressure distribution on rectangular buildings with changes in aspect ratio and wind direction

  • Lee, Young Tae;Boo, Soo Ii;Lim, Hee Chang;Misutani, Kunio
    • Wind and Structures
    • /
    • 제23권5호
    • /
    • pp.465-483
    • /
    • 2016
  • This study aims to enhance the understanding of the surface pressure distribution around rectangular bodies, by considering aspects such as the suction pressure at the leading edge on the top and side faces when the body aspect ratio and wind direction are changed. We carried out wind tunnel measurements and numerical simulations of flow around a series of rectangular bodies (a cube and two rectangular bodies) that were placed in a deep turbulent boundary layer. Based on a modern numerical platform, the Navier-Stokes equations with the typical two-equation model (i.e., the standard $k-{\varepsilon}$ model) were solved, and the results were compared with the wind tunnel measurement data. Regarding the turbulence model, the results of the $k-{\varepsilon}$ model are in overall agreement with the experimental results, including the existing data. However, because of the blockage effects in the computational domain, the pressure recovery region is underpredicted compared to the experimental data. In addition, the $k-{\varepsilon}$ model sometimes will fail to capture the exact flow features. The primary emphasis in this study is on the flow characteristics around rectangular bodies with various aspect ratios and approaching wind directions. The aspect ratio and wind direction influence the type of wake that is generated and ultimately the structural loading and pressure, and in particular, the structural excitation. The results show that the surface pressure variation is highly dependent upon the approaching wind direction, especially on the top and side faces of the cube. In addition, the transverse width has a substantial effect on the variations in surface pressure around the bodies, while the longitudinal length has less influence compared to the transverse width.

국내 1.5 km CAPPI 자료 보완을 위한 Gap Filler Radar의 효용성 평가 (Evaluation of the Gap Filler Radar as an Implementation of the 1.5 km CAPPI Data in Korea)

  • 유철상;윤정수;김정호;노용훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.521-521
    • /
    • 2015
  • This study evaluated the gap filler radar as an implementation of the 1.5 km CAPPI data in Korea. The use of the 1.5 km CAPPI data was an inevitable choice, given the topography of the Korean Peninsula and the location of the radar. However, there still exists a significant portion of beam blockage, and thus there has been debate about the need to introduce the gap filler radar (or, the gap-filler). This study evaluated the possible benefits of introducing gap-fillers over the Korean Peninsula. As a first step, the error of the radar data was quantified by the G/R ratio and RMSE, and the radar data over the Korean Peninsula were evaluated. Then, the gap-fillers were located where the error was high, whose effect was then evaluated by the decrease in the G/R ratio and RMSE. The results show that the mean values of the G/R ratio and RMSE of the 1.5 m CAPPI data over the Korean Peninsula were estimated to be about 2.5 and 4.5 mm/hr, respectively. Even after the mean-field bias correction, the RMSE of the 1.5 km CAPPI data has not decreased much to be remained very high around 4.4 mm/hr. Unfortunately, the effect of the gap-filler on the 1.5 CAPPI data was also found very small, just 1 - 2%. However, the gap-filler could be beneficial, if the lowest elevation angle data were used instead of the 1.5 km CAPPI data. The effect of five gap-fillers could be up to 7% decrease in RMSE.

  • PDF

풍동실험을 통한 수평축 풍력터빈 모델의 공력성능 연구 (Aerodynamic Performance for Horizontal Axis Wind Turbine Model using Subsonic Wind Tunnel)

  • 유기완;윤성준;이창수;최성옥
    • 한국항공우주학회지
    • /
    • 제35권11호
    • /
    • pp.964-972
    • /
    • 2007
  • 공기역학적으로 최대동력계수를 얻을 수 있도록 최적화된 블레이드를 장착한 수평축 풍력터빈 모델을 아음속 풍동에 장착하여 공력특성을 실험하였다. Upwind 방식과 downwind방식의 풍력 터빈 로터의 공력 특성을 비교하였을 때, 후자가 전자에 비해 측정토크의 교란이 더 크게 나타났으며, 이는 지지대에서 발생된 후류와 블레이드의 상호간섭이 원인으로 작용한다고 여겨진다. 블레이드 설치각이 0o인 경우에 설계 속도비 6에 해당하는 위치에서 최대 동력계수를 보여주고 있어 설계 조건을 잘 만족함을 알 수 있었다. 또한 음의 피치각 변화가 같은 값의 양의 피치각 변화에 비해 더 커다란 동력 감소가 발생되는 결과를 보여주었다.

초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 원형핀이 설치된 유출면에서의 열/물질전달 특성 (Heat/Mass Transfer on Effusion Plate with Circular Pin Fins for Impingement/Effusion Cooling System with Intial Crossflow)

  • 홍성국;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제29권7호
    • /
    • pp.828-836
    • /
    • 2005
  • Impingement/effusion cooling technique is used for combustor liner or turbine parts cooling in gas turbine engine. In the impingement/effusion cooling system, the crossflow generated in the cooling channel induces an adverse effect on the cooling performance, which consequently affects the durability of the cooling system. In the present study, to reduce the adverse effect of the crossflow and improve the cooling performance, circular pin fins are installed in impingement/effusion cooling system and the heat transfer characteristics are investigated. The pin fins are installed between two perforated plates and the crossflow passes between these two plates. A blowing ratio is changed from 0.5 to 1.5 for the fixed jet Reynolds number of 10,000 and five circular pin fin arrangements are considered in this study. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The results show that local distributions of heat/mass transfer coefficient are changed due to the installation of pin fins. Due to the generation of vortex and wake by the pin fin, locally low heat/mass transfer regions are reduced. Moreover, the pin fin prevents the wall jet from being swept away, resulting in the increase of heat/mass transfer. When the pin fin is installed in front of the impinging let, the blockage effect on the crossflow enhances the heat/mass transfer. However, the pin fin installed just behind the impinging jet blocks up the wall jet, decreasing the heat/mass transfer. As the blowing ratio increases, the pin fins lead to the higher Sh value compared to the case without pin fins, inducing $16\%{\~}22\%$ enhancement of overall Sh value at high blowing ratio of M=1.5.

The effects of limestone powder and fly ash as an addition on fresh, elastic, inelastic and strength properties of self-compacting concrete

  • Hilmioglu, Hayati;Sengul, Cengiz;Ozkul, M. Hulusi
    • Advances in concrete construction
    • /
    • 제14권2호
    • /
    • pp.93-102
    • /
    • 2022
  • In this study, limestone powder (LS) and fly ash (FA) were used as powder materials in self-compacting concrete (SCC) in increasing quantities in addition to cement, so that the two powders commonly used in the production of SCC could be compared in the same study. Considering the reduction of the maximum aggregate size in SCC, 10 mm or 16 mm was selected as the coarse aggregate size. The properties of fresh concrete were determined by slump flow (including T500 time), V-funnel and J-ring experiments. The experimental results showed that as the amount of both LS and FA increased, the slump flow also increased. The increase in powder material had a negative effect on V-funnel flow times, causing it to increase; however, the increase in FA concretes was smaller compared to LS ones. The increase in the powder content reduced the amount of blockage in the J-ring test for both aggregate sizes. As the hardened concrete properties, the compressive and splitting strengths as well as the modulus of elasticity were determined. Longitudinal and transverse deformations were measured by attaching a special frame to the cylindrical specimens and the values of Poisson's ratio, initiation and critical stresses were obtained. Despite having a similar W/C ratio, all SCC exhibited higher compressive strength than NVC. Compressive strength increased with increasing powder content for both LS and FA; however, the increase of the FA was higher than the LS due to the pozzolanic effect. SCC with a coarse aggregate size of 16 mm showed higher strength than 10 mm for both powders. Similarly, the modulus of elasticity increased with the amount of powder material. Inelastic properties, which are rarely found in the literature for SCC, were determined by measuring the initial and critical stresses. Crack formation in SCC begins under lower stresses (corresponding to lower initial stresses) than in normal concretes, while critical stresses indicate a more brittle behavior by taking higher values.