• Title/Summary/Keyword: bladder neck

Search Result 50, Processing Time 0.029 seconds

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.

Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor (토모테라피와 선형가속기를 이용한 동일 부위의 치료 시 종양 및 정상조직의 흡수선량 평가)

  • Cheon, Geum-Seong;Kim, Chang-Uk;Kim, Hoi-Nam;Heo, Gyeong-Hun;Song, Jin-Ho;Hong, Joo-Yeong;Jeong, Jae-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.97-103
    • /
    • 2010
  • Purpose: Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. Materials and Methods: After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two differents modalities. Results: The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head & neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. Conclusion: In case of comparing both simple summation absorbed dose and integration absorbed dose, the minimum dose are represented higher as well as the maximum dose come out lower and the average dose are revealed similar with our expected values data. It is able to evaluate tumor & normal tissue absorbed dose which could had been not realized by treatment plan system. The DVH of interesting region are prescribed lower dose than expected. From now on, it needs to develop the new modality which are able to realize exact dose distribution as well as integration absorbed dose evaluation in same treatment region with different modalities.

  • PDF

Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator (다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Kim, Woo Chul;Ji, Young Hoon;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • For evaluating the treatment planning accurately, the quality assurance for treatment planning is recommended when patients were treated with IMRT which is complex and delicate. To realize this purpose, treatment plan quality assurance software can be used to verify the delivered dose accurately before and after of treatment. The purpose of this study is to evaluate the accuracy of treatment plan quality assurance software for each IMRT plan according to MLC DLG (dosimetric leaf gap). Novalis Tx with a built-in HD120 MLC was used in this study to acquire the MLC dynalog file be imported in MobiusFx. To establish IMRT plan, Eclipse RTP system was used and target and organ structures (multi-target, mock prostate, mock head/neck, C-shape case) were contoured in I'mRT phantom. To verify the difference of dose distribution according to DLG, MLC dynalog files were imported to MobiusFx software and changed the DLG (0.5, 0.7, 1.0, 1.3, 1.6 mm) values in MobiusFx. For evaluation dose, dose distribution was evaluated by using 3D gamma index for the gamma criteria 3% and distance to agreement 3 mm, and the point dose was acquired by using the CC13 ionization chamber in isocenter of I'mRT phantom. In the result for point dose, the mock head/neck and multi-target had difference about 4% and 3% in DLG 0.5 and 0.7 mm respectively, and the other DLGs had difference less than 3%. The gamma index passing-rate of mock head/neck were below 81% for PTV and cord, and multi-target were below 30% for center and superior target in DLGs 0.5, 0.7 mm, however, inferior target of multi-target case and parotid of mock head/neck case had 100.0% passing rate in all DLGs. The point dose of mock prostate showed difference below 3.0% in all DLGs, however, the passing rate of PTV were below 95% in 0.5, 0.7 mm DLGs, and the other DLGs were above 98%. The rectum and bladder had 100.0% passing rate in all DLGs. As the difference of point dose in C-shape were 3~9% except for 1.3 mm DLG, the passing rate of PTV in 1.0 1.3 mm were 96.7, 93.0% respectively. However, passing rate of the other DLGs were below 86% and core was 100.0% passing rate in all DLGs. In this study, we verified that the accuracy of treatment planning QA system can be affected by DLG values. For precise quality assurance for treatment technique using the MLC motion like IMRT and VMAT, we should use appropriate DLG value in linear accelerator and RTP system.

Usability Assessment of Plan Transfer between TOMO HAD and Radixact : Planning Study (TOMO HDA와 Radixact 치료 계획 간 Transfer에 대한 유용성 평가 : Planning Study)

  • An, Ye Chan;Kim, Jong Sik;Kwon, Dong Yeol;Kim, Jin Man;Choi, Byeong Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.117-128
    • /
    • 2018
  • Purpose : To evaluate the usability of plan transfer between TOMO HD and Radixact, we compared the differences of dose in transferred plans by evaluating the dose of normal organ and target. TOMO HDA and Radixact. The completed plans were transferred each other and we compared the differences of dose by evaluating the DVH of each plans. Materials and Methods : We planned 4 different plans assuming the treatment of 2 cases in Head and Neck Cancer and 2 cases Prostate cancer. Each plan was designed so that 95 % of the prescription dose was irradiated over 99 % of the target volume, and the normal organ constraints dose was based on the SMC tolerance dose protocol. Each plan was transferred to each equipment and DVH(dose volume histogram) analysis of the transferred plans was compared and evaluated. Results : The Mean dose of CTV and GTV was increased and decreased in the transferred plans, but there was no significant differences. The target coverage of CTV and GTV was decreased in all cases of transferred plans from TOMO HAD to Radixact, and the change of CI and HI in CTV was within 0.1. Normal organ dose was increased in most cases when transferring from HAD to Radixact in both treatment plans. Conclusion : According to the results of this experiment, the target coverage was above the standard and the normal organ dose was almost same or decreased when transferring the plans from Radixact to HDA equipment. However the target coverage was reduced when transferring the plans from HDA to Radixact and there was an increase in dose in normal organs that could cause sever side effects such as Optic Chiasm ($D_{max}$1.38 Gy), Bladder ($D_{max}$3.07 Gy), Penile Bulb ($D_{max}$1.14 Gy). Therefore, it is necessary to pay attention to the dose change when transferring the plan and one-time transfer due to equipment inspection will be useful for efficient radiation therapy, but if the transferred treatment plans continue for several consecutive days, the treatment plan should be resumed.

  • PDF

Clinical Study for Conversion Disorder in 41 Admission Cases (전환장애(轉換障碍)로 입원(入院)한 환자(患者) 41례(例)에 대(對)한 임상적(臨床的) 고찰(考察))

  • Kim Myung-Jin;Choi Byung-Man;Lee Sang-Ryong
    • Journal of Oriental Neuropsychiatry
    • /
    • v.11 no.2
    • /
    • pp.131-140
    • /
    • 2000
  • The clinical study was carried out the 41 patients with conversion disorder who were treated in Dae Jeon University Oriental Hospital from 26 september 1998 to 21 september 2000.The results were summarized as follows.1. The ratio of male and female was 4:37 and in the age distribution, the highest frequence was 40s, in descending order over 50s, 30s, 20s, 10s and mental attack was the most inducing factor.2. In distribution of the period of the clinical history. within one day was the highest percentage and in admission period most of the patients were from four days to seven days.3. In symptoms and signs, physical symptoms were more than mental symptoms, physical symptoms had many muscle-skeleton-system symptoms and they were in descending order general body weakness. headache, anorexia, chest discomfort, dyspepsia, dizziness, four extremities numbness, insomnia, dysarthria, anxiety, four extremities tremor. palpitation. nausea, vomiting, facial numbness.4. In classification of Four Human coporeal constitution the number of patients, Sho-Eum-In(少陰人) was remarked mostly and most of female patients had no past history of the conversion disorder.5. In distribution of the prescription, drugs of regulating gi such as BUNSIMGIEUM(分心氣飮) were many, in descending order drugs of growing heart and warming gall bladder such as ONDAMTANGGAMI(溫膽湯加味), drugs of maintaining patency for the flow of gi such as CHUNGGANSOYOSAN(淸肝逍遙散), drugs of decomposing food and asending gi such as PYUNGJINGUNBITANG(平陳健脾湯), drugs of storing blood and relaxing the mind such as SAMULGUIBITANG(四物歸脾湯). drugs of removing sputum and cooling heart such as CHUNGSIMDODAMTANG 淸心導痰湯).6. In distribution of the treatments, the group of drug and acupuncture and aroma-therapy was many, in acup uncture TAEGUKCHIMBUP(太極針法) was mainly used. in therapy inhalation type of Lavender and Rosewood was many and the type of Peppermint and Rosemary massaging epigastric-chest, and neck was many.7. In distribution of the treatment result, in 15 patients(36.6%) symptoms were eliminated from four to seven days, in 13 patients(31.7%) symptoms were not changed. in 12 patients(29.3%) symptoms were eliminated from two to three days. in 1 patients(2.4%) symptoms were eliminated whin one day.

  • PDF

Analysis of Studies on Quality of Life according to Cancer Types and Symptoms (암의 종류 및 증상에 따른 삶의 질 평가 척도에 관한 연구 현황 분석)

  • Lee, Nam-Heon;Cho, Jung-Hyo;Son, Chang-Gue;Yoo, Hwa-Seung;Lee, Yeon-Weol;Yoon, Dam-Hee;Lee, Jong-Hoon;Bang, Sun-Hwi;Cho, Chong-Kwan
    • The Journal of Internal Korean Medicine
    • /
    • v.27 no.3
    • /
    • pp.555-560
    • /
    • 2006
  • Objectives : The objective of this study is to analyze what quality of life(QOL) scales are frequently used in cancer patients and lay a cornerstone to develop new QOL scales adequate for oriental medical anti-cancer treatment in the future. Methods : We searched 151 articles concerned with 'QOL and scale and cancer' from PubMed and classified them according to periods. nations. cancer types and symptoms. Results: 138 articles(91%) were published after 1996. 65 articles(43%) were published in USA. For breast. lung, prostate. esophageal cancer and melanoma. European Organization for Research and Treatment of Cancer-quiality of life questionaire(EORTC-QLQ) was used most frequently to evaluate quality of life. Functional Assessment of Cancer Treatment(FACT) for bladder cancer. Hospital Anxiety and Depression Scale(HADS) for colorectal cancer and of Washington Quality of Life questionnaire(UW-QOL) for Head & Neck cancer were used repeatedly. And for the patients with the symptoms such as bone marrow depression. depression. pain. dyspnea. nausea & vomiting and voice change. the investigators used EORTC-QLQ mainly to evaluate QOL. FACT-An(anemia) for anemia. FACT-BMT(bone marrow transplant) for bone marrow depression were applicated generally. Conclusions It is anticipated that further investigations will be performed to develop adequate QOL scales for oriental medical anti-cancer therapy.

  • PDF

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

Immunohistochemical and Immunogold Electron Microscopic Studies on Effects of Cis-platin on the Ciliogenesis of Rat Oviducts (Cis-Platin이 흰쥐 난관의 섬모형성에 미치는 영향에 대한 면역조직학적 및 면역도금법에 의한 전자현미경적 연구)

  • Kim, Jin-Kook;Kim, Won-Kyu;Paik, Doo-Jin;Chung, Ho-Sam
    • Applied Microscopy
    • /
    • v.30 no.1
    • /
    • pp.45-59
    • /
    • 2000
  • Cis-platin is a widely used anticancer drug against certain solid tumors such as malignant ovarian tumor, malignant carcinoma of head and neck, bladder cancer and cervical cancer of uterus, and its major mechanism of action is inhibition of DNA synthesis of the tumor cell. To investigate the inhibitory effects of cis-platin on the ciliogensis of the ciliated cells in the mucosa of oviduct, the author pursued the alterations of $\alpha-tubulin$, which is the main constituent of the microtubles in cilia, after cis-platin treatment. To eliminate the possible variations due to ovarian cycle, female Spargue-Dawley rats ($150\sim200gm$ in B.W.) were pretreated with estradiol benzoate (20 mg/kg, once a day, for 4 consecutive days). Animals were administrated with cis-platin (6 mg/kg, i.p.) and sacrificed at 1day, 3days, 5days and 7days after treatment, respectively. Immunohistochemistry for $\alpha-tubulin$ using mouse anti-rat $\alpha-tubulin$ monoclonal antibody as primary antibody was done. Immunogold electronmicroscopy for intracellular distributions of $\alpha-tubulin$ was also performed with same primary antibody and Goat anti- mouse IgM which is preconjugated with gold particles of 15 nm as secondary antibody. The results obtained were as follows; 1. Strong immunoreactivity of $\alpha-tubulin$ was observed in ciliated cells of oviducts at 1, 3 and 5 days after estradiol pretreatment. 2. Weak immunoreactivity of $\alpha-tubulin$ was observed in ciliated cells of oviducts at 1 and 3 days after cis-platin treatment but it was recovered to strong immunoreactivity in 5 days 3. In immunogold electronmicroscopy, density of gold particles for $\alpha-tubulin$ reactions was decreased in apical cytoplasm, but few changes were observed in basal body or cilia at 1 and 3 days after cis-platin treatment. From these above results, it is indicated that synthesis of $\alpha-tubulin$ in ciliated cells of rat oviduct is inhibited by cis-platin treatment.

  • PDF

Oxidative Pathway of $C^{14}-glucose$ in Various Human Cancer Tissues (각종 인체 암조직의 당의 산화경로 분석)

  • Lee, Bong-Kee;Lee, Sang-Don
    • The Korean Journal of Physiology
    • /
    • v.2 no.1
    • /
    • pp.23-30
    • /
    • 1968
  • Tissue homogenates of 12 kinds of human cancer tissues were incubated separately in medium containing $C^{14}-1-glucose$ and $C^{14}-6-glucose$ as a substrate in order to observe the oxidative pathway of glucose in the tumor tissues. At the end of 3 hours incubation in the Dubnuff metabolic shaking incubator, respiratory $CO_2$ samples trapped by alkaling which was placed in the center well of incubation flask were analysed for total $CO_2$ production rates and their radioactivities. The tissue homogenate samples after incubation were analyzed for their concentrations of glucose, lactate and pyruvate. Calculations were made on the glucose consumption rate and accumulation rates of lactate and pyruvate. Fractionation of oxidative pathway of glucose was carried out by calculating $C^{14}O_2 yields from C-1 and C-6 carbon of glucose. The following results were obtained. 1. In 12 kinds of human cancer, total $CO_2$ production rates were less than $8{\mu}M/gm$ except 2 cases. These lower values impressed that oxidative metabolism in the tumor tissues generally inhibited as compared with that in normal tissues. On the other hand, fractions of $CO_2$ derived from glucose to total $CO_2$ production rates (RSA) were less than 10% in every case. These facts showed that oxidation of glucose into $CO_2$ was remarkably inhibited in the tumor tissues. 2. Factions of glucose disappeared into $CO_2\;(RGD_{CO_2})$, lactate $(RGD_L)$, pyruvate $(RGD_P)$ to glucose consumption rates were as follows. $RGD_{CO_2}$ were less than 2% in cases of in this experiment and $RGD_L$ showed more than 5% except in 2 cases. These facts showed that anaerobic degradation of glucose into 3 carbon compounds was easily proceeded but further degradation into $CO_2$ via the TCA cycle was greatly inhibited resulting in accumulation of lactate. There are large variation in values of $RGD_P$ in different kinds of tumor tissue but relatively higher values in $RGD_{CO_2}$ were obtained in the tumor tissues as compared with those of normal tissues. 3. The oxidative pathway of glucose in tumor tissues were analyzed from the values of RSA which were obtained in $C^{14}-1\;and\;C^{14}-6-glucose$ incubation experiments. It was found that 3% of $CO_2$ derived from glucose were oxidized via the principal EMP-TCA cycle and the remainder were via alternate pathway such as HMP in the liver cancer and values in other cancer tissues were as follows; 4% in the tongue cancer, 6% in the colon cancer, 6% in the lung cancer, 9% in the stomach cancer, 11% in the ovarian cancer, 12% in the neck tumor, 22% in the uterine cancer, 22% in the bladder tumor, 32% in the spindle cell sarcoma and 65% in the brain tumor. These values except later 2 cases showed less than 30% which is the lowest value among the normal tissues. Even in the brain tumor in which showed highest value in the tumor group. It is reasonable to suppose that this fraction was remarkably decreased because values in normal brain tissue was more than 90%. From the above data, it was concluded that in tumor tissues, oxidation of glucose via TCA cycle was greatly inhibited but correlation between degree of inhibited oxidation of glucose via TCA cycle and malignancy of tumor were not clarified in this experiments.

  • PDF

Convolution-Superposition Based IMRT Plan Study for the PTV Containing the Air Region: A Prostate Cancer Case (Convolution-Superposition 알고리즘을 이용한 치료계획시스템에서 공기가 포함된 표적체적에 대한 IMRT 플랜: 전립선 케이스)

  • Kang, Sei-Kwon;Yoon, Jai-Woong;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.271-277
    • /
    • 2013
  • In prostate IMRT planning, the planning target volume (PTV), extended from a clinical target volume (CTV), often contains an overlap air volume from the rectum, which poses a problem inoptimization and prescription. This study was aimed to establish a planning method for such a case. There can be three options in which volume should be considered the target during optimization process; PTV including the air volume of air density ('airOpt'), PTV including the air volume of density value one, mimicking the tissue material ('density1Opt'), and PTV excluding the air volume ('noAirOpt'). Using 10 MV photon beams, seven field IMRT plans for each target were created with the same parameter condition. For these three cases, DVHs for the PTV, bladder and the rectum were compared. Also, the dose coverage for the CTV and the shifted CTV were evaluated in which the shifted CTV was a copied and translated virtual CTV toward the rectum inside the PTV, thus occupying the initial position of the overlap air volume, simulating the worst condition for the dose coverage in the target. Among the three options, only density1Opt plan gave clinically acceptable result in terms of target coverage and maximum dose. The airOpt plan gave exceedingly higher dose and excessive dose coverage for the target volume whereas noAirOpt plan gave underdose for the shifted CTV. Therefore, for prostate IMRT plan, having an air region in the PTV, density modification of the included air to the value of one, is suggested, prior to optimization and prescription for the PTV. This idea can be equally applied to any cases including the head and neck cancer with the PTV having the overlapped air region. Further study is being under process.