• Title/Summary/Keyword: bite system

Search Result 85, Processing Time 0.025 seconds

Development and application of the new ASC system in No.2 cold rolling mill (2 냉연 신형상제어 시스템 개발 및 적용)

  • 박남수;심민석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1068-1071
    • /
    • 1996
  • Good shape on flat rolled product is necessary to meet today's customer quality requirement. To meet the increasing demand in quality of strip shape from downstream customers, POSCO has replaced the Automatic Shape Control(ASC) system with the existing one that had used noncontact type measuring system at No.2 Cold Rolling Mill, Pohang works in October, 1995. The strip shape is influenced by the profile, roll crown, bending control, skew control system, as well as work roll cooling system. We have used ASC to adjust those factors in Cold Rolling Mill that could get a satisfactory result, almost less than .+-.5 1-unit deviation from the target shape. However, the downstream customer(i.e. Continuos Annealing Line) wants a good shape not only at the moment of exit of roll bite, but after rolling without tension. In this investigation, the difference will be discussed and how deal with this problem.

  • PDF

A Development of Noise Detection System Utilizing the Vibrating Accelerative Sensor for the Reduction Gear Box (진동가속도센서를 이용한 Reduction Gear Box Noise 검출시스템 개발)

  • Cheon, Jong-Pil;Pyun, Young-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.274-279
    • /
    • 2009
  • Reduction Gear Box where from productive site uses the gear with power delivery with high mechanical efficiency of power a deceleration and as the mechanical element union product which has the velocity ratio which is various together is produced with the power occurrence motor and leads gets a high driving force is plentifully used. The above occurs from gear drive issue sound Whine, Noise and Vibration as occurring from the rim process which the gear will bite mainly is delivered with the case etc. gear drive whole which leads the axis and the bearing. The productivity falls with the going straight rate decrease which with like this problem point is caused by with rework the problem point where the cost of production rises under improving boil many kinds analyzed the plan and investigates the resultant acceleration sensor which and a frequency analysis system and was made to apply.

  • PDF

Micro/Meso Cutting with Micro Turning Lathe (Micro 선반을 이용한 Micro/Meso 절삭에 관한 연구)

  • 고태조;김희술;배영호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1025-1028
    • /
    • 2002
  • In this paper, a micro-turning lathe is introduced for micro machining of aluminum rod. To give feed motion, stepwise motion[2] actuators are used instead of the conventional inchworm mechanism. These are consisted of two Piezoelectric ceramics; one is for feeding the slider, and the other is for clamping the slider in the guide way of the body. The guide is V-form. The linearity and positional accuracy of the actuators is good enough far high precision motion. Since the system is more compact than the conventional system using three Piezoelectric ceramics, it is applicable for the micro-machine or MEMS unit. To fabricate the lathe, a small spindle unit with ball bearings of diameter of 10 millimeter is built-up on the top the slider. The motion is feed backed with miniaturized linear encoder attached each axis slider. The diamond tool bite is used for cutting tool. The machining is tried to make small diameter rod. The possible diameter that can be machined in this machine is presented as well as chip formation, surface roughness, and machinability.

  • PDF

Development of Cutting Tool in Non-ferrous Metals at Turning (선삭에서 비철금속 절삭용 공구의 개발)

  • Chung, J.S.;Jun, J.U.;Ha, M.K.
    • Journal of Power System Engineering
    • /
    • v.6 no.1
    • /
    • pp.82-87
    • /
    • 2002
  • Not only ferrous but also non-ferrous materials such as aluminum, brass, plastic and woods need cutting operation in recent manufacturing industry. Over the past few years a considerable number of studies have been made on non-ferrous metal cutting. But more study is required to meet various engineering needs. The purpose of this paper is to preform an experiment on the influence of feed-rate adjustment and side rake angle in turning operations from non-ferrous metals. As a result, the surface roughness was reduced when a side-rake angle increases and feed-rate decreases in the case of the plastic, brass, aluminum, and paulownia. Therefore, this papers develop a new type bite that be used to adjust side-rake angle.

  • PDF

A STUDY OF THE OCCLUSAL CONTACT PATTERN DURING MANDIBULAR MOVEMENTS OF ADULT WITH NORMAL OCCLUSION (T-scan을 이용한 성인정상교합자의 하악운동시 치아접촉양상에 관한 연구)

  • Chai Young-Ah;Park Nam-Soo;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.565-579
    • /
    • 1993
  • This study was accomplished to analyse and compare the occlusal contact patterns during eccentric mandibular movements in adult with normal occlusion. 50 subjects(male 27, female 23), who had natural occlusion and no symptom of temporomandibular disorder, were selected. Teeth contact patterns during mandibular eccentric movements were recorded and the distribution of tooth contacts in maximum intercuspation analysed by T-scan system. And then, tooth contact numbers recored by T-scan and silicone bite registration at centric occlusion were analysed and compared. The results obtained were as follows : 1. Antero-posteriorly, the qualitative center of occlusal contacts in centric occlusion were in the first molar areas, but there was a slight deviation in left-right directions. Thus, distribution of occlusal contacts were not bilaterally symmetric. 2. During the mandibular movements from centric occlusal position to right lateral and left lateral directions, the frequency that maxillary canine joined in lateral guidance was relatively high, but pure canine protected occlusion or pure group function occlusion had small frequency. 3. During mandibular protrusive movement, one or more maxillary central incisors frequently joined in protrusive guidance. 4. During mandibular eccentric movements, working and balancing side premature contact was observered in relatively high frequency. 5. In centric occlusal position, the numbers of occlusal contacts recorded on T-scan were relatively smaller than on silicone bite registration.

  • PDF

The Association Between Masticatory Function Assessment and Masseter Muscle Thickness in the Elderly

  • Jung, Hyo-Jung;Min, Yong-Guang;Kim, Hyo-Jung;Lee, Joo-Young;Choi, Jong-Hoon;Kim, Baek-Il;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.45 no.3
    • /
    • pp.49-55
    • /
    • 2020
  • Purpose: This study investigated the association between the objective indicator of masticatory function assessment and the masseter muscle thickness (MMT) using ultrasound imaging. Methods: A total of 99 subjects (males: 24, females: 75, mean age: 76) were analyzed. The maximum bite force (MBF) was measured with a pressure-sensitive sheet and an image scanner. The mixing ability index (MAI) was calculated by image analysis after asking the subjects to chew a wax specimen. The MMT during rest and clenching were obtained with a diagnostic ultrasound system, and the difference in MMT during rest and MMT during clenching was defined as the difference in masseter muscle thickness (DMMT). Multiple regression analysis was performed to determine the independent variables affecting MBF and MAI. Results: The MBF showed correlation with the number of remaining teeth (β=0.346, p=0.002) and DMMT (β=0.251, p=0.011). The MAI correlated with only the number of remaining teeth (β=0.476, p<0.001). Conclusions: The DMMT reflects the state of masseter muscle contraction, and can be used as a predictor as well as the number of teeth when assessing masticatory function.

A case of full mouth rehabilitation in patient with loss of vertical dimension and deep bite due to tooth wear (치아 마모로 인한 수직고경감소와 과개교합을 가진 환자에서 전악 수복 증례)

  • Seo, Seong-Yong;Lee, Na-Young;Kang, Jeong-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • The collapse of the posterior occlusion destroys the normal occlusal plane and causes excessive wear reducing the vertical dimension. Reduced vertical dimension of occlusion causes not only aesthetic and functional problems but also overloading on the temporomandibular joints and abnormalities of muscle nerve system. In order to improve the collapsed occlusal relationship, it is necessary to consider the change of the vertical dimension. It is necessary to make a precise diagnosis and analysis before the treatment and to evaluate the adaption of patient to the new vertical dimension of occlusion. A patient with excessive overbite often has occlusal problems of tooth wear and tooth eruption. Considering these considerations, overall prosthodontic restoration is required to solve the problem. A patient of 68 year old man in this case who suffered major tooth wear and maxillary posterior teeth loss was treated with elevation of vertical dimension of occlusion by maxillary removable dental prosthesis and mandibular fixed prosthesis.

A STUDY OF OCCLUSAL CONTACT VARIATON DUE TO CHANGE IN EACH HEAD POSITION IN NORMAL OCCLUSION (정상교합인의 두부위치변화에 따른 교합접촉점의 변화에 관한 연구)

  • Choi, Hee-Cheol;Lee, Sung-Bok;Choi, Dae-Gyun;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.769-779
    • /
    • 1995
  • The understanding the nature of occlusal tooth contacts of natural dentition is important for correct diagnosis and treatment of diseases developed in stomatognatic system. Several investigator have studied the distribution of tooth contacts in maximum intercuspation and have repored contact locations with respect to the tooth position. However, there are few report the variation of the occlusal contact point with change in each head position. This study analysed the number of occlusal contact point with change in each head position. 30 subject(male 17, female 13), who ahad natural occlusion and no symptoms of temporomandibular disorder, were selected. The numbers and patterns of tooth contact were recorded by silicone bite registration on stone model at four different head positions with head anguration gauge(from the supine to the upright position). The results obtained were as follows : 1. The numbers of total occlusal contact point on teeth increased to average 25, 29, 35, 42 points as head angulation was changed from the supine to the upright position against the ala-tragus line, and there was significant difference(P<0.05). 2. In the 19 subject(65%)of total 30 subject, the perforated point of the silicone bite indicated that the locus for the prime contact point moved mesially as the head angulation was changed from the supine to the upright position. 3. On the basis of the fact that the anterior occlusal contact point increase as head angulation changed from the supine to the upright position, we could find that the mandibular position is moved anteriorly.

  • PDF

Implant treatment on anterior cross-bite of a patient who had orthognathic surgery 20 years ago (20년전 악교정수술을 받았던 환자의 심한 전치부 반대교합의 해결을 위한 임플란트 치료 증례)

  • Park, Kwang Man;Leesungbok, Richard;Lee, Suk Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.245-253
    • /
    • 2019
  • Orthognathic surgery of skeletal Class III malocclusion improves oral function and facial appearance. The greater amount of skeletal discrepancy, the greater amount of teeth movement required for decompensation, and this often causes pathological changes in periodontal tissue especially in lower anterior dentition. We made a Top-Down treatment plan with personalized analysis using Face Hunter, Plane System and ARCUS Digma II, in order to resolve severe mobility and cross-bite of lower anterior teeth for 49-year-old female patient who had undergone orthognathic surgery 20 years ago due to skeletal Class III malocclusion and mandibular prognathism. Lower anterior teeth were extracted and alveoloplasty was done. After healing of the wound, immediate loading was conducted immediately after implant placement. Final restorations were fabricated Zirconia using CAD/CAM, and inserted intraorally screw-retained type. During 6-month follow-up, no abnormal episodes of restorations were observed, and obtained satisfactorily both of functional and esthetic outcomes.

Film Image Transfer System (FITS): An Efficient Method for Proper Positioning of Orthodontic Mini-implants

  • Go, Taek-Su;Kim, Seong-Hun;Nelson, Gerald
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • Purpose: To describe the newly developed Film image transfer system (FITS) for proper positioning of the orthodontic mini-implant in the narrow interdental space and considerations for better application. Materials and Methods: A patient who was planning to have orthodontic mini-implant treatment on the posterior maxilla was recruited to assess the feasibility of FITS. Dental radiographic film and bite record was taken. And then the film image was transferred on the photographic emulsion coated model using transfer light through film projector (enlarger). After exposing the photo emulsion coating on the model, the image was developed with a working solution for a paper developer and fixed. The surgical guide for the mini-implant was fabricated from the transported FITS data. Results: The completed surgical guide was easily placed intraorally, and allowed a simple and rapid placement of the mini-implant. The site of the implant placement was accurate as planned position. Conclusion: In the reported case, The FITS technique represents an effort to minimize risk to the patient and produce consistently good results based upon accurate information about the anatomy of the implant site.