• Title/Summary/Keyword: bipolar recording

Search Result 17, Processing Time 0.022 seconds

Influences of Inter-electrode Distance on Electrogastrography Measurements (위전도 측정을 위한 전극간 부착거리에 관한 연구)

  • Han, Wan-Taek;Song, In-Ho;Kim, In-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.341-346
    • /
    • 2009
  • Cutaneous electrogastrography is the measurement of electrical activity of the stomach on the abdominal surface. The validity of cutaneous electrogastrography is dependent upon the quality of the recording technique. The locations of electrodes are an important issue. We examined the influences of the inter-electrode distance of bipolar leads on electrogastrography measurements. The sensitivity distributions of EGG leads were calculated based on a 2D body fat model and evaluated according to the region of interest sensitivity ratio (ROISR). We simulated the ROISR of the inter-electrode distance in relation to various body fat thicknesses. The distance between the electrodes was proportional to the distance between the ROI and the surface of the abdomen. The results imply that inter-electrode distance can be applied in electrogastrography according to human body fat thickness.

The Influence of the Reference Electrode on Compound Muscle Action Potential Onset Latency and Amplitude (복합근육활동전위의 시작잠복기와 진폭에 대한 기준전극의 영향)

  • Lee, Sang-Moo;Choi, Heui-Chul;Son, Jong-Hee
    • Annals of Clinical Neurophysiology
    • /
    • v.12 no.1
    • /
    • pp.11-15
    • /
    • 2010
  • Background: In belly-tendon (bipolar) montage, reference (R2) electrode placed on muscle's tendon has traditionally been considered to be electrically inactive. However, recent studies have revealed that R2 electrode is not simply referential, but actively contributes to compound muscle action potential (CMAP) waveform morphology. These findings suggest that CMAP onset latency and amplitude may also be influenced by the position of R2 electrode. This study was performed in order to evaluate the effect of R2 electrode position on CMAP onset latency and amplitude. Methods: We performed motor nerve conduction studies of median, ulnar, tibial and peroneal nerves on bilateral limbs of 20 normal subjects. We used traditional bipolar and monopolar montage and compared their CMAP onset latencies and amplitudes. In bipolar montage, recording (R1) electrode was placed on mid-belly of muscle with R2 electrode on the tendon of the muscle. In monopolar montage, R1 electrode was placed on the same site of bipolar montage, while R2 electrode was placed on the contralateral limb. Results: The mean CMAP onset latencies of median and peroneal nerves in bipolar montage were significantly different (p<0.05) with those in monopolar montage. And those of ulnar and tibial nerves were not significantly different (p>0.05). The mean CMAP amplitudes of all the tested nerves except ulnar nerve were significantly different (p<0.05). Conclusions: This study shows that change in R2 electrode position can affect the CMAP onset latency and amplitude, and these differences seem to be related to the generation of far field potential by CMAP.

Design and Fabrication of VTR Audio Signal Processor IC (VTR 음성신호 처리용 집적회로의 설계 및 제작)

  • Shin, Myung-Chul
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.4
    • /
    • pp.618-624
    • /
    • 1987
  • This paper describes the design and fabrication of a signal processing integrated circuit required for the recording and playback of VTR audio signal. The integrated circuit was designed using 8\ulcorner design rule and its chip size is 2.5x2.5mm\ulcorner It was fabricated using SST bipolar standard process technology. The measurement analysis of the fabricated circuit proves the satisfactory DC characteristics and its proper audio signal processing funcstion.

  • PDF

Independent Component Analysis(ICA) of Sleep Waves (수면파형의 독립성분분석)

  • Lee, Il-Keun
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.1
    • /
    • pp.67-71
    • /
    • 2001
  • Independent Component Analysis (ICA) is a blind source separation method using unsupervised learning and mutual information theory created in the late eighties and developed in the nineties. It has already succeeded in separating eye movement artifacts from human scalp EEG recording. Several characteristic sleep waves such as sleep spindle, K-complex, and positive occipital sharp transient of sleep (POSTS) can be recorded during sleep EEG recording. They are used as stage determining factors of sleep staging and might be reflections of unknown neural sources during sleep. We applied the ICA method to sleep EEG for sleep waves separation. Eighteen channel scalp longitudinal bipolar montage was used for the EEG recording. With the sampling rate of 256Hz, digital EEG data were converted into 18 by n matrix which was used as a original data matrix X. Independent source matrix U (18 by n) was obtained by independent component analysis method ($U=W{\timex}X$, where W is an 18 by 18 matrix obtained by ICA procedures). ICA was applied to the original EEG containing sleep spindle, K-complex, and POSTS. Among the 18 independent components, those containing characteristic shape of sleep waves could be identified. Each independent component was reconstructed into original montage by the product of inverse matrix of W (inv(W)) and U. The reconstructed EEG might be a separation of sleep waves without other components of original EEG matrix X. This result (might) demonstrates that characteristic sleep waves may be separated from original EEG of unknown mixed neural origins by the Independent Component Analysis (ICA) method.

  • PDF

Statistics on Radiation Field Waveforms Associated with Multiple Intracloud Lightning Discharges

  • Lee, Bok-Hee;Lee, Dong-Moon;Ahn, Chang-Hwan;Kim, Young-Bong
    • Journal of KIEE
    • /
    • v.11 no.1
    • /
    • pp.32-40
    • /
    • 2001
  • This paper presents the detailed statistics on radiation field signatures associated with multiple-intracloud lightning discharges. A transient signal recording system was used to measure the electric and magnetic fields produced by lightning flashes. The measurements were made in th summers of 1995 through 1999, and the location of the observation station was in Inchon on the coast of the Yellow Sea in Korea(37$^{\circ}$25'N, 126$^{\circ}$ 39'E). Most of lightning flashes typically contains between two and five strokes. The individual intracloud stork radiation fields were the bipolar pulse. On the average, the ratio of the peak of the second stroke to the first stroke peak was 75.1$\pm$40.1% for the negative, and a fraction of the subsequent stroke peaks were higher than the first stroke peak. The greater the number of the subsequent stroke order, less time separations between strokes were produced. The mean of the depth of the dip was 81.2$\pm$27.9% for the positive polarity and 75.9$\pm$24.4% for the negative. The depth of the dip increased for the positive bipolar pulses and decreased for the negative as the number of the stroke order increased.

  • PDF

Glottic Closure Reflex in an Anesthetized and Awake Canine Model (개의 성문폐쇄반사에 미치는 중추조절의 영향에 관한 연구)

  • 강주완;김광문;김영호
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.14 no.2
    • /
    • pp.83-87
    • /
    • 2003
  • Background and Objectives : Sphincteric function of the larynx, essential to lower airway protection, is most efficiently achieved through strong reflex adduction by both vocal cords. We hypothesize that central facilitation is an essential component of a bilateral adductor reflex and that its disturbance could result in weakened sphincteric closure. Materials and Method : Seven adult 20kg dogs underwent evoked response laryngeal electromyoraphy under 0.5 to 1.0 MAC isoflurane anesthesia. The internal branch of superior laryngeal nerve was stimulated through bipolar platinum-iridium electrodes and recording electrodes were positioned in the ipsilateral and contralateral thyroaryteonoid muscles. Results : Consistent threshold responses were obtained ipsilaterally under all anesthetic levels. However, contralateral reflex responses disappeared as anesthetic levels approached 1.0 MAC. Additionally, at 0.5 MAC, late responses (R2) were detected in one animal. Conclusion : Alteration of central facilitation by deepening anesthesia abolishes the crossed adductor reflex, predisposing to a weakened glottic closure response. Precise understanding of this effect may improve the prevention of aspiration in patients emerging from prolonged sedation or under heavy psychotropic control.

  • PDF

Features and Statistics on the Magnetic Field Waveforms Radiated by Intracloud Discharges (운방전에 의해서 방사된 자계 파형의 특징과 통계)

  • Lee, Bok-Hee;Lee, Dong-Moon;Cho, Sung-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.59-66
    • /
    • 2005
  • This paper presents some features and statistics of electromagnetic pulses radiated from intracloud lightning discharges. The LabVIEW based-measurement system of time-dependent electromagnetic fields was constructed. The frequency bandwidth of the measuring system ranged from 300[Hz] to 1[MHz], and the response sensitivity was 2.78(mV/nT). The resolution and the maximum recording length of the data acquisition system were 12(bits) and 100[ms], respectively. In the electromagnetic pulses radiated from intracloud discharges, a pronounced bipolar pulse appeared with one or more fast pulses superimposed on the initial front part of the bipolar pulse. The mean duration of intracloud discharges was $1.05{\pm}0.32[ms]$, and an average of about 8 outburst pulses appeared for a period.

Common Practices in Clinical Electroencephalography (임상뇌파검사의 일반적인 관행)

  • Hyun, Soon-Chul;Kim, Dongyeop
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.4
    • /
    • pp.296-308
    • /
    • 2021
  • Electroencephalography (EEG) provides the most accurate and quickest diagnosis of epilepsy. It is also an important examination for the real-time evaluation of brain function and seizures, no matter where. In the field of epilepsy, it is appropriate for a clinical pathologist with considerable knowledge of EEG and clinical experience to perform the role of a Physician Assistant (PA). The electrode attachment method is based on the international 10-20 system. The EEG reading is mainly taken by longitudinal bipolar montage. However, a reading using only one montage may result in an error. Hence, two or more montages should be used for readings according to the clinical situation. In the EEG, electric potentials are seen as contour lines. The most important principle in EEG reading is under-reading, not over-reading. The higher the repetitions of the EEG recording, the greater the sensitivity of the reading. For a good reading, the EEG recording must be of good quality. So, the relationship between the neurologist and the EEG technician is very important. In the future, it is expected that the field of activities of the EEG technician with abundant EEG reading experience and clinical practical knowledge will be further expanded.

Triggered Electrooculography for Identification of Oculomotor and Abducens Nerves during Skull Base Surgery

  • Jeong, Ha-Neul;Ahn, Sang-Il;Na, Minkyun;Yoo, Jihwan;Kim, Woohyun;Jung, In-Ho;Kang, Soobin;Kim, Seung Min;Shin, Ha Young;Chang, Jong Hee;Kim, Eui Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.282-288
    • /
    • 2021
  • Objective : Electrooculography (EOG) records eyeball movements as changes in the potential difference between the negatively charged retina and the positively charged cornea. We aimed to investigate whether reliable EOG waveforms can be evoked by electrical stimulation of the oculomotor and abducens nerves during skull base surgery. Methods : We retrospectively reviewed the records of 18 patients who had undergone a skull base tumor surgery using EOG (11 craniotomies and seven endonasal endoscopic surgeries). Stimulation was performed at 5 Hz with a stimulus duration of 200 μs and an intensity of 0.1-5 mA using a concentric bipolar probe. Recording electrodes were placed on the upper (active) and lower (reference) eyelids, and on the outer corners of both eyes; the active electrode was placed on the contralateral side. Results : Reproducibly triggered EOG waveforms were observed in all cases. Electrical stimulation of cranial nerves (CNs) III and VI elicited positive waveforms and negative waveforms, respectively, in the horizontal recording. The median latencies were 3.1 and 0.5 ms for craniotomies and endonasal endoscopic surgeries, respectively (p=0.007). Additionally, the median amplitudes were 33.7 and 46.4 μV for craniotomies and endonasal endoscopic surgeries, respectively (p=0.40). Conclusion : This study showed reliably triggered EOG waveforms with stimulation of CNs III and VI during skull base surgery. The latency was different according to the point of stimulation and thus predictable. As EOG is noninvasive and relatively easy to perform, it can be used to identify the ocular motor nerves during surgeries as an alternative of electromyography.

Measurement and Statistical Analysis of Magnetic Fields Produced by Cloud Discharges (운방전에 의해 발생되는 자장의 계측과 통계적 분석)

  • Lee Bok-Hee;Gil Hyoung-.Jun;Cho Sung-Chul;Shim Eung-Bo;Woo Jung-Wook
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.6
    • /
    • pp.262-268
    • /
    • 2005
  • In this work, to obtain the detailed information about lightning electromagnetic field waveforms, the LabVIEW based-measurement system of time-changing magnetic fields was designed and constructed. The frequency bandwidth of the magnetic field measuring system ranges from 300 [Hz] to 1 [MHz], and the response sensitivity is 2.78 [mV/nT]. Data acquisition system with the resolution of 12 bits and memory capacity of 32 [Mbyte] was triggered by the magnetic field to be measured. The properties and parameters of the magnetic fields produced by cloud discharges were statistically investigated. The magnetic field waveforms radiated from cloud lighting discharges tend to be bipolar, with two or more narrow and several pulses superimposed on the initial front part. The recording length of the magnetic field measurement system is about 10 [ms]. The mean duration of cloud discharges is 1.3 [ms], and the number of outburst pulses for the period is 8 in average. The front times of the magnetic fields are 6.15 [$\mu$s] in average. The the zero-to-zero crossing times that is the initial half-cycle duration is widely dispersed and the mean value is 9.61 [$\mu$s], and the mean value of percentage depth of dip to opposite polarity is 41.1 [$\%$].