• 제목/요약/키워드: biomedical implant devices

검색결과 16건 처리시간 0.01초

이식형 전자의료기 연구동향과 기술개발의 과제 (Research Trends and Challenges in Technology Development of Medical Electronic Implant Devices)

  • 조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권6호
    • /
    • pp.415-430
    • /
    • 2008
  • The technologies in medical electronic implant(MEI) devices are developing rapidly, and already, there are various kinds of the MEI devices in the current medical equipments market. Recently, the global market scale of MEI devices have been increased about 13% year by year, and the import amount of MEI devices in Korea is increasing rapidly. In the near future, the demands of MEI devices will be magnificently increasing by the continuous development of the biomedical electronics devices which coupled with neural, brain and other organs will bring us to tremendous effects, such as providing new therapeutic solutions to patients, extension and saving human life, and an important clue of medical development. However, the investment of the research and the activity of developments in this field are still very weak in the Korea. Consequently, this paper introduces about the research trends of MEI devices, and technological problems those must be solved, and then concludes with the suggestions in order to be the leading country in this field.

바이오응용 무선전력전달을 위한 13.56 MHz CMOS 다단 정류기 (A 13.56 MHz CMOS Multi-Stage Rectifier for Wireless Power Transfer in Biomedical Applications)

  • 차혁규
    • 전자공학회논문지
    • /
    • 제50권3호
    • /
    • pp.35-41
    • /
    • 2013
  • $0.18-{\mu}m$ CMOS 반도체 공정을 이용하여 신체에 깊이 이식되어 있는 deep implant 의료 전자기기에서의 무선전력전달을 위한 고효율의 다단 정류기 (multi-stage rectifier)를 구현하였다. 세 개의 단계로 이루어진 정류기는 cross-coupled 된 구조를 이용하여 외부에서 전달되는 작은 AC 입력 신호를 boost하여 1.2-1.5 V의 DC 출력 신호를 implant 전자기기로 전달한다. 설계 된 정류기는 13.56 MHz에서 0.6-Vpp의 작은 RF 입력 신호와 $10-k{\Omega}$의 load 저항이 연결 된 측정 환경에서 최대 70 %의 전력 변환 효율을 달성하였다.

치과용 임플란트에 대한 ISO 14971 기반의 리스크관리 (Application of Risk Management for Dental Implants Based on ISO 14971)

  • 윤지훈;김영진;전계록;정창모
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.92-97
    • /
    • 2012
  • Risk management is the process that helps to identify hazards, analyze them, and then to create an action plan to avoid and mitigate these hazards. The main objective of risk management in product development and manufacturing is to provide safe and efficient products without spending too many resources. Medical device manufacturers also face enormous risks - regulatory, legal, and financial - based on their products and processes, and the concepts of risk management are particularly important because any single failure may result in serious damages to body or loss of life. In this regard, a set of guidelines for the application of risk management to medical devices has been issued by ISO and specified in the document ISO 14971 Medical devices - Application of risk management to medical devices. The main objective of this study is to investigate the application of risk management to dental implant development and manufacturing processes based on ISO 14971. A general risk management process is first introduced, and the application of ISO 14971 to dental implants is further investigated.

Nanowire Patterning for Biomedical Applications

  • Yun, Young-Sik;Lee, Jun-Young;Yeo, Jong-Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.382-382
    • /
    • 2012
  • Nanostructures have a larger surface/volume ratio as well as unique mechanical, physical, chemical properties compared to existing bulk materials. Materials for biomedical implants require a good biocompatibility to provide a rapid recovery following surgical procedure and a stabilization of the region where the implants have been inserted. The biocompatibility is evaluated by the degree of the interaction between the implant materials and the cells around the implants. Recent researches on this topic focus on utilizing the characteristics of the nanostructures to improve the biocompatibility. Several studies suggest that the degree of the interaction is varied by the relative size of the nanostructures and cells, and the morphology of the surface of the implant [1, 2]. In this paper, we fabricate the nanowires on the Ti substrate for better biocompatible implants and other biomedical applications such as artificial internal organ, tissue engineered biomaterials, or implantable nano-medical devices. Nanowires are fabricated with two methods: first, nanowire arrays are patterned on the surface using e-beam lithography. Then, the nanowires are further defined with deep reactive ion etching (RIE). The other method is self-assembly based on vapor-liquid-solid (VLS) mechanism using Sn as metal-catalyst. Sn nanoparticle solutions are used in various concentrations to fabricate the nanowires with different pitches. Fabricated nanowries are characterized using scanning electron microscopy (SEM), x-ray diffraction (XRD), and high resolution transmission electron microscopy (TEM). Tthe biocompatibility of the nanowires will further be investigated.

  • PDF

2채널 마이크로폰을 이용한 청각 기기에서의 빔포밍에 대한 객관적 검증 (Objective Evaluation of Beamforming Techniques for Hearing Devices with Two-channel Microphone)

  • 조경원;한종희;홍성화;이상민;김동욱;김인영;김선일
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.198-206
    • /
    • 2011
  • Hearing devices like cochlear implant, vibrant soundbridge, etc. try to offer better sound for people. In hearing devices, several beamformers including conventional directional microphone are applicable to noise reduction. Each beamformer has different directional response and it could change sound intelligibility or quality for listeners. Therefore, we investigated the performance of three beamformers, which are first and second order directional microphone, and broadband beamformer(BBF) with a computer simulation assuming hearing device microphone configuration. We also calculated objective measurements which have been used to evaluate speech enhancement algorithms. In the simulation, a single speech and a single babble noisewere propagated from the front and $135^{\circ}$ azimuth degrees respectively. Microphones were configured in an end-fire array and the spacing was varied in comparison. With 3 cm spacing, BBF had about 3 dB higher enhanced SNR than that of directional microphones. However, enhancement of segmental SNR and frequency weighted segmental SNR were similar between the first order directional microphone and broadband beamformer. In addition when steady state noise was used, broadband beamformer showed the increased performance and had the highest enhanced SNR, and segmental SNR.

완전 이식형 인공중이를 위한 자동 충전종료형 무선 충전장치의 구현 (Implementation of Wireless Charger with the Function of Auto-Shutdown for fully Implantable Middle Ear Hearing Devices)

  • 이장우;임형규;정의성;한지훈;이승현;박일용;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권4호
    • /
    • pp.539-548
    • /
    • 2007
  • In the paper, a wireless charger with the function of auto-shutdown for fully implantale middle ear hearing devices (F-IMEHD) has been designed. The wireless charger can communicate with an implant module to be turned off automatically shutdown after an internal rechargeable battery has been fully-charged by electromagnetic coupling using two coils. For the communication with an implant module, the wireless charger uses the load shift keying (LSK) method. But, the variation of the mutual inductance due to the different distance between two coils can cause the communication error in receiving the fully-charged signal from an implant module. To solve the problem, the implemented wireless charger has a variable reference generator for LSK communication. The wireless charger generates proper level of the reference voltage for a comparator using an ADC (analog-to-digital converter) and a DAC (digital-to-analog converter). Through the result of experiment, it has been confirmed that the presented wireless charger can detect signals from implantable module. And wireless charger can stop generating electromagnetic flux after an implanted battery has been fully charged in spite of variable coil distance according to different skin thickness.

Maxillary resection for cancer, zygomatic implants insertion, and palatal repair as single-stage procedure: report of three cases

  • Salvatori, Pietro;Mincione, Antonio;Rizzi, Lucio;Costantini, Fabrizio;Bianchi, Alessandro;Grecchi, Emma;Garagiola, Umberto;Grecchi, Francesco
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제39권
    • /
    • pp.13.1-13.8
    • /
    • 2017
  • Background: Oronasal/antral communication, loss of teeth and/or tooth-supporting bone, and facial contour deformity may occur as a consequence of maxillectomy for cancer. As a result, speaking, chewing, swallowing, and appearance are variably affected. The restoration is focused on rebuilding the oronasal wall, using either flaps (local or free) for primary closure, either prosthetic obturator. Postoperative radiotherapy surely postpones every dental procedure aimed to set fixed devices, often makes it difficult and risky, even unfeasible. Regular prosthesis, tooth-bearing obturator, and endosseous implants (in native and/or transplanted bone) are used in order to complete dental rehabilitation. Zygomatic implantology (ZI) is a valid, usually delayed, multi-staged procedure, either after having primarily closed the oronasal/antral communication or after left it untreated or amended with obturator. The present paper is an early report of a relatively new, one-stage approach for rehabilitation of patients after tumour resection, with palatal repair with loco-regional flaps and zygomatic implant insertion: supposed advantages are concentration of surgical procedures, reduced time of rehabilitation, and lowered patient discomfort. Cases presentation: We report three patients who underwent alveolo-maxillary resection for cancer and had the resulting oroantral communication directly closed with loco-regional flaps. Simultaneous zygomatic implant insertion was added, in view of granting the optimal dental rehabilitation. Conclusions: All surgical procedures were successful in terms of oroantral separation and implant survival. One patient had the fixed dental restoration just after 3 months, and the others had to receive postoperative radiotherapy; thus, rehabilitation timing was longer, as expected. We think this approach could improve the outcome in selected patients.

MICS 표준에 기반한 무선 텔레메트리 시스템 개발 (Development of a wireless telemetry system based on MICS standard)

  • 이승하;박일용
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.

Fabrication and Characterization of the Ti-TCP Composite Biomaterials by Spark Plasma Sintering

  • Mondal, Dibakar;Park, Hyun-Kuk;Oh, Ik-Hyun;Lee, Byong-Taek
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.53.2-53.2
    • /
    • 2011
  • Ti metal has superior mechanical properties along with biocompatibility, but it still has the problem of bio-inertness thus forming weaker bond in bone/implant interface and long term clinical performance as orthopaedic and dental devices are restricted for stress shielding effect. On the other hand, despite the excellent biodegradable behavior as being an integral constituent of the natural bone, the mechanical properties of ${\beta}$-tricalcium phosphate $(Ca_3(PO_4)_2;\;{\beta}-TCP)$ ceramics are not reliable enough for post operative load bearing application in human hard tissue defect site. One reasonable approach would be to mediate the features of the two by making a composite. In this study, ${\beta}$-TCP/Ti ceramic-metal composites were fabricated by spark plasma sintering in inert atmosphere to inhibit the formation of $TiO_2$. Composites of 30 vol%, 50 vol% and 70 vol% ${\beta}$-TCP with Ti were fabricated. Detailed microstructural and phase characteristics were investigated by FE-SEM, EDS and XRD. Material properties like relative density, hardness, compressive strength, elastic modulus etc. were characterized. Cell viability and biocompatibility were investigated using the MTT assay and by examining cell proliferation behavior.

  • PDF

심부 조직 인체 삽입용 세 가지 밴드 안테나 (A Triple Band Deep-Tissue Antenna for Biomedical Implants)

  • 유형석
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.383-386
    • /
    • 2017
  • In this study, we introduce a triple-band flexible implantable antenna that is tuned by using a ground slot in three specific bands, namely Medical Implanted Communication Service (MICS: 402-405 MHz) for telemetry, the midfield band (lower gigahertz: 1.45-1.6 GHz) for Wireless Power Transfer (WPT), and the Industrial, Scientific and Medical band (ISM: 2.4-2.45 GHz) for power conservation. This antenna is wrapped inside a printed 3D capsule prototype to show its applicability in different implantable or ingestible devices. The telemetry performance of the proposed antenna was simulated and measured by using a porcine heart. From the simulation and measurement, we found that use of a ground slot in the implantable antenna can improve the antenna performance and can also reduce the Specific Absorption Rate (SAR).