• Title/Summary/Keyword: biomedical diagnosis

Search Result 784, Processing Time 0.023 seconds

Potential role of ANGPTL4 in cancer progression, metastasis, and metabolism: a brief review

  • Min Seok Park;Sang Eun Kim;Pureunchowon Lee;Ju-Hee Lee;Kyung Hee Jung;Soon-Sun Hong
    • BMB Reports
    • /
    • v.57 no.8
    • /
    • pp.343-351
    • /
    • 2024
  • Angiopoietin-like 4 (ANGPTL4) has been identified as an adipokine involved in several non-metabolic and metabolic diseases, including angiogenesis, glucose homeostasis, and lipid metabolism. To date, the role of ANGPTL4 in cancer growth and progression, and metastasis, has been variable. Accumulating evidence suggests that proteolytic processing and posttranslational modifications of ANGPTL4 can significantly alter its function, and may contribute to the multiple and conflicting roles of ANGPTL4 in a tissue-dependent manner. With the growing interest in ANGPTL4 in cancer diagnosis and therapy, we aim to provide an up-to-date review of the implications of ANGPTL4 as a biomarker/oncogene in cancer metabolism, metastasis, and the tumor microenvironment (TME). In cancer cells, ANGPTL4 plays an important role in regulating metabolism by altering intracellular glucose, lipid, and amino acid metabolism. We also highlight the knowledge gaps and future prospect of ANGPTL4 in lymphatic metastasis and perineural invasion through various signaling pathways, underscoring its importance in cancer progression and prognosis. Through this review, a better understanding of the role of ANGPTL4 in cancer progression within the TME will provide new insights into other aspects of tumorigenesis and the potential therapeutic value of ANGPTL4.

Development of a Prediction Model for Fall Patients in the Main Diagnostic S Code Using Artificial Intelligence (인공지능을 이용한 주진단 S코드의 낙상환자 예측모델 개발)

  • Ye-Ji Park;Eun-Mee Choi;So-Hyeon Bang;Jin-Hyoung Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.526-532
    • /
    • 2023
  • Falls are fatal accidents that occur more than 420,000 times a year worldwide. Therefore, to study patients with falls, we found the association between extrinsic injury codes and principal diagnosis S-codes of patients with falls, and developed a prediction model to predict extrinsic injury codes based on the data of principal diagnosis S-codes of patients with falls. In this study, we received two years of data from 2020 and 2021 from Institution A, located in Gangneung City, Gangwon Special Self-Governing Province, and extracted only the data from W00 to W19 of the extrinsic injury codes related to falls, and developed a prediction model using W01, W10, W13, and W18 of the extrinsic injury codes of falls, which had enough principal diagnosis S-codes to develop a prediction model. 80% of the data were categorized as training data and 20% as testing data. The model was developed using MLP (Multi-Layer Perceptron) with 6 variables (gender, age, principal diagnosis S-code, surgery, hospitalization, and alcohol consumption) in the input layer, 2 hidden layers with 64 nodes, and an output layer with 4 nodes for W01, W10, W13, and W18 exogenous damage codes using the softmax activation function. As a result of the training, the first training had an accuracy of 31.2%, but the 30th training had an accuracy of 87.5%, which confirmed the association between the fall extrinsic code and the main diagnosis S code of the fall patient.

Intelligent Diagnosing Method Based on the Conditional Probability for the Pancreatic Cancer Early Detection (췌장암 조기진단을 위한 조건부 확률 기반 지능형 진단 방식)

  • JANG, IK GYU;JUNG, JOONHO;KO, JAE HO;MOON, HYUN SEOK;JO, YUNG HO
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.227-231
    • /
    • 2017
  • Early diagnosis of pancreatic cancer had been considered one of the important barrier for successful therapy since the five year survival rate after treatment of pancreatic cancer was critically low. Nonetheless, patients often miss the golden time of treatment because they rarely visit the hospital until their symptoms are severe. To overcome these problems, a lot of information about the patient's symptoms should be applied as biomarkers for early diagnosis. For this reason, a biomarker for early detection of pancreatic cancer (CA19-9) has been developed as a diagnostic kit. However, since the diagnosis is not accurate enough, pancreatic symptoms (abdominal pain, jaundice, anorexia, diabetes, etc.) and biomarkers (CA19-9) should be considered together. We develop an intelligent diagnostic system that considers CA19-9 and the incidence of pancreatic cancer for pancreatic symptoms that was determined by studying a large number of patient information. It shows a higher accuracy than one using CA19-9 alone. It may increase the survival rate of pancreatic cancer because it can diagnose pancreatic cancer early.

Preparation of IgG-$^{188}$Re Conjugate for Diagnosis of Abscess (농양진단을 위한 IgG-$^{188}$Re 표지화합물 제조)

  • 오옥두;최태현;임상무
    • Biomedical Science Letters
    • /
    • v.3 no.2
    • /
    • pp.131-138
    • /
    • 1997
  • IgG-$^{188}$Re conjugate was prepared for the diagnosis of abscess. The IgG molecules reduced by 2-mercaptoethanol contained 1.5 free sulfhydryl groups per IgG molecule. The reduced IgG molecule was labelled with $^{188}$Re through chelate to 99% of labelling yield. The radiochemical purity of IgG-$^{188}$Re conjugate was maintained at 90% in the presence of human serum for 1 hour. The IgG-$^{188}$Re was intravenously administered into staphylococcal abscess-bearing rats and their biodistribution was monitored at 4 and 24 hours post injection. The IgG-$^{188}$Re conjugate was moderately localized in the abscess tissue. This result implies that the IgG-$^{188}$Re conjugate can be a tool for abscess diagnosis. This technique can be applied for the preparation of various monoclonal antibody labelled with $^{188}$Re.

  • PDF

Establishment for Improving Productivity of Cattle by Fecal Steroid and Milk Urea Nitrogen analysis - II. Application of Early Pregnancy Diagnosis and Monitoring Postpartum Ovarian Activity

  • Kang, Chung-Boo;Ha, Woo-Song;Kwon, Ji-In;Yu, Young-Sang;Kim, Chul-Ho;Kwak, Soo-Dong
    • Biomedical Science Letters
    • /
    • v.9 no.1
    • /
    • pp.29-36
    • /
    • 2003
  • Progesterone levels in the blood plasma or skim milk of cows are considered to be very useful indicator fur the detection of estrus cycle and early pregnancy diagnosis. During 13 to 14 days after estrus the level of progesterone in plasma or skim milk were not different between the inseminated arid non-inseminated cows. In the pregnant cows the peak level of progesterone reached on 14th day after artificial insemination (AI), but in the absence of conceptus the level declines after the 14th day slowly, and then very rapidly towards the basal level after the 17th day. This low level persists about 4 days, including those of estrus and ovulation a highly characteristic pattern which differs so markedly from that in the pregnant cows. Progesterone levels in blood plasma or skim milk can provided a reliable diagnosis of early pregnancy and monitoring ovarian activity in cows. The mean $\pm$ standard deviation of milk urea nitrogen(MUN) and protein concentration in the cows at 9 herds were 17.7$\pm$2.35 mg/dL and 3.2$\pm$0.17%, respectively. The days of nonpregnant after parturition was shorter in the cows in which the lower level of MUN than higher level of MUN concentration.

  • PDF

A Rapid, Simple Determination of Sulfur-containing Compounds and Methylmalonic Acid on Plasma using GC-MS-SIM for the Diagnosis of Homocysteinemia (혈장 중 황함유 화합물과 메틸말론산의 신속 간편한 분석법 개발; GC-MS-SIM을 이용한 호모시스테인혈증의 진단)

  • Yoon, Hye-Ran;Thapa, Maheshwor
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.3
    • /
    • pp.138-146
    • /
    • 2015
  • Purpose: If early diagnosis is not made, patients with metabolic disorders as homocystinemia rapidly progress to physical defect or mental retardation resulted in storage of the toxic material into the brain. Therefore, it is necessary to develop an analytical method for a rapid screening and/or correct confirmation diagnosis. Methods: The standard solution of sulfur amino acids spiked plasma was subjected to protein precipitation with methanol, and then consecutively derivatized with trimethylsilyl (TMS) and trifluoroacyl (TFA) and determined by GC-MS. The formation of TMS derivative of the hydroxyl and TFA derivative of amino functional group was performed by BSTFA and MBTFA, respectively. Selective ion monitoring (SIM) mode was used for quantification with selected specific ions. Results: A calibration curve on standard spiked pooled plasma showed a linear relationship with correlation coefficient of 0.9936-0.9992 for all compounds over the range of 0.1-300 ng. The precision and accuracy were within S.D. of 1-15% and RSD of 1-15% for intra-day assay at 2 ng/mL, 15 ng/mL and 30 ng/mL. LOD and LOQ was 0.4 ng/mL and 4 ng/mL respectively. Conclusion: A rapid analytical method was developed to quantify sulfur amino acids and methyl malonic acid, after two-step derivatization procedure with good sensitivity and specificity on human plasma. Advantages of a new method are simplicity and rapidity. The method could be useful for routine analysis, diagnosis of homocysteinemia.

Evaluation of alveolar bone grafting in unilateral cleft lip and palate patients using a computer-aided diagnosis system

  • Sutthiprapaporn, Pipop;Tanimoto, Keiji;Nakamoto, Takashi;Kongsomboon, Supaporn;Limmonthol, Saowaluck;Pisek, Poonsak;Keinprasit, Chutimaporn
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.225-229
    • /
    • 2012
  • Purpose: This study aimed to evaluate the trabecular bone changes after alveolar bone grafting in unilateral cleft lip and palate (UCLP) patients using a computer-aided diagnosis (CAD) system. Materials and Methods: The occlusal radiographs taken from 50 UCLP patients were surveyed retrospectively. The images were categorized as: 50 images in group 0 (before bone grafting), 33 images in group 1 (one month after bone grafting), 24 images in group 2 (2-4 months after bone grafting), 15 images in group 3 (5-7 months after bone grafting), and 21 images in group 4 (8 or more months after bone grafting). Each image was grouped as either "non-cleft side" or "cleft side". The CAD system was used five times for each side to calculate the pixel area based on the mathematical morphology. Significant differences were found using a Wilcoxon signed ranks test or paired samples t test. Results: The pixel area showed a significant difference between the "non-cleft side" and "cleft side" in group 0 ($404.27{\pm}103.72/117.73{\pm}92.25$; p=0.00), group 1 ($434.29{\pm}86.70/388.31{\pm}109.51$; p=0.01), and group 4 ($430.98{\pm}98.11/366.71{\pm}154.59$; p=0.02). No significant differences were found in group 2 ($423.57{\pm}98.12/383.47{\pm}135.88$; p=0.06) or group 3 ($433.02{\pm}116.07/384.16{\pm}146.55$; p=0.19). Conclusion: Based on the design of this study, alveolar bone grafting was similar to normal bone within 2-7 months postoperatively.

Development of 68Ga-human serum albumin as a PET imaging agent for diagnosis of acute inflammation

  • Lee, Ji Youn;Kim, Hoyoung;Lee, Boeun;Kim, Young Ju;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.104-108
    • /
    • 2015
  • Human serum albumin (HSA) has potential for diagnosis and therapy in clinical setting. The purpose of experiments was to develop and evaluate $^{68}Ga$-HSA as a PET agent for diagnosis of acute inflammation. NOTA-HSA was synthesized by conjugating 2-(p-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid to HSA in 0.1 M sodium carbonate buffer (pH 9.5) and then purified using a PD-10 size-exclusion column. NOTA-HSA was labeled with $^{68}Ga$ at room temperature for 10 min, and 8.4% sodium hydrogen carbonate buffer was added for neutralization. $^{68}Ga$-NOTA-HSA was purified using alumina N plus light cartridge and $0.22{\mu}m$ syringe filter. Labeling efficiency and radiochemical purity were determined by ITLC-SG with 0.1 M citric acid. Biodistribution study was performed in a male BALB/c mice model of Carrageenan-induced acute inflammation. Animal PET study was performed in acute inflammation mice model after tail vein injection of $^{68}Ga$-HSA. This radiotracer showed high labeling efficiency (>99%) around pH 7. Biodistribution study showed higher inflamed footpad uptake than control footpad uptake. Animal PET study revealed 2 times higher uptake on inflamed footpad compared to control footpad. In these experiments, we developed $^{68}Ga$-HSA for acute inflammation PET imaging and evaluated it in a mouse disease model. The results demonstrated that $^{68}Ga$-HSA has potential as a PET imaging agent for diagnosis of acute inflammation.

A study on floating and sinking pulse by classification of pulse pattern through analysis of P-H volume-curve at 5 applied pressure levels (5단계 가압에 대한 맥파 변화 분석에 의한 맥 패턴 분류와 부침맥(浮沈脈) 연구)

  • Kown, Sun-Min;Kang, Hee-Jung;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.13-22
    • /
    • 2010
  • Objectives: The information on the depth where pulse wave appears is as important as pulse waveform. The aim of this study was to classify pulse pattern using pressure-height(P-H) volume-curve by 5 applied pressure levels to find out the information on the depth of pulse and interpret the floating & sinking pulse in oriental medical pulse diagnosis. Methods: We used 3 dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea), which measures radial pulse waveforms noninvasively by way of tonometric method at 5 applied pressure levels, and shows P-H volume-curves by applied pressure. 448 subjects were enrolled, pulse waveforms were measured and the P-H volume-curves were gained on the three locations of Chon, Kwan, and Cheok. Results: Gained P-H volume curves were classified into 3 types ; increase type, decrease type, and increase-decrease type. Increase-decrease type appeared more often on Chon and Kwan, while increase type appeared more often on Cheok. In a few cases, decrease-type appeared on Chon and Kawn, however it never appeared on Cheok. Conclusions: Through the classification of pulse by P-H volume-curve, we gained the information on the depth of pulse. We speculate the decrease type as floating pulse, the increase-decrease type as middle pulse, and the increase type as sinking pulse in oriental medical pulse diagnosis. After more researches on P-H volume-curve by applied pressure, the P-H volume-curve may be used as an important factor for pulse diagnosis.

Electrochemical Biosensors for Biomedical and Clinical Applications: A Review

  • Rahman Md. Aminur;Park Deog-Su;Shim Yoon-Bo
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.271-282
    • /
    • 2005
  • There are strong demands for accurate, fast, and inexpensive devices in the medical diagnostic laboratories, such as biosensors and chemical sensors. Biosensors can provide the reliable and accurate informations on the desired biochemical parameters, which is an essential prerequisite for a patient before going for a treatment. They can be used for continuous measurements of metabolites, blood cations, gases, etc. Of these, electrochemical biosensors play an important role in the improvement of public health, because rapid detection, high sensitivity, small size, and specificity are achievable for clinical diagnostics. In this paper, the clinical applications with electrochemical biosensors are reviewed. An attempt is also made to highlight some of the trends that govern the research and developments of the important biosensors that are associated to clinical diagnosis.