• 제목/요약/키워드: biomechanics

검색결과 1,638건 처리시간 0.036초

Impact of Screw Type on Kyphotic Deformity Correction after Spine Fracture Fixation: Cannulated versus Solid Pedicle Screw

  • Arbash, Mahmood Ali;Parambathkandi, Ashik Mohsin;Baco, Abdul Moeen;Alhammoud, Abduljabbar
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.1053-1059
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To detect the effect of cannulated (poly-axial head) and solid (mono-axial head) screws on the local kyphotic angle, vertebral body height, and superior and inferior angles between the screw and the rod in the surgical management of thoracolumbar fractures. Overview of Literature: Biomechanics studies showed that the ultimate load, yield strength, and cycles to failure were significantly lower with cannulated (poly-axial head) pedicle comparing to solid core (mono-axial head). Methods: The medical charts of patients with thoracolumbar fractures who underwent pedicle screw fixation with cannulated or solid pedicle screws were retrospectively reviewed; the subjects were followed up from January 2011 to December 2015. Results: Total 178 patients (average age, $36.1{\pm}12.4years$; men, 142 [84.3%]; women, 28 [15.7%]) with thoracolumbar fractures who underwent surgery and were followed up at Hamad Medical Corporation were classified, based on the screw type as those with cannulated screws and those with solid screws. The most commonly affected level was L1, followed by L2 and D12. Surgical correction of the local kyphotic angle was significantly different in the groups; however, there was no significant difference in the loss of correction of the local kyphotic angle of the groups. Surgical correction of the reduction in the vertebral body height showed statistical significance, while the average loss of correction in the reduction of the vertebral body height was not significantly different. The measurement of the angles made by the screws on the rods was not significantly different between the cannulated (poly-axial head) and solid (mono-axial head) screw groups. Conclusions: Solid screws were superior in terms of providing increased correction of the kyphotic angle and height of the fractured vertebra than the cannulated screws; however, no difference was noted between the screws in the maintenance of the superior and inferior angles of the screw with the rod.

Biomechanical Study of Posterior Pelvic Fixations in Vertically Unstable Sacral Fractures: An Alternative to Triangular Osteosynthesis

  • Chaiyamongkol, Weera;Kritsaneephaiboon, Apipop;Bintachitt, Piyawat;Suwannaphisit, Sitthiphong;Tangtrakulwanich, Boonsin
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.967-972
    • /
    • 2018
  • Study Design: Biomechanical study. Purpose: To investigate the relative stiffness of a new posterior pelvic fixation for unstable vertical fractures of the sacrum. Overview of Literature: The reported operative fixation techniques for vertical sacral fractures include iliosacral screw, sacral bar fixations, transiliac plating, and local plate osteosynthesis. Clinical as well as biomechanical studies have demonstrated that these conventional techniques are insufficient to stabilize the vertically unstable sacral fractures. Methods: To simulate a vertically unstable fractured sacrum, 12 synthetic pelvic models were prepared. In each model, a 5-mm gap was created through the left transforaminal zone (Denis zone II). The pubic symphysis was completely separated and then stabilized using a 3.5-mm reconstruction plate. Four each of the unstable pelvic models were then fixed with two iliosacral screws, a tension band plate, or a transiliac fixation plus one iliosacral screw. The left hemipelvis of these specimens was docked to a rigid base plate and loaded on an S1 endplate by using the Zwick Roell z010 material testing machine. Then, the vertical displacement and coronal tilt of the right hemipelves and the applied force were measured. Results: The transiliac fixation plus one iliosacral screw constructions could withstand a force at 5 mm of vertical displacement greater than the two iliosacral screw constructions (p=0.012) and the tension band plate constructions (p=0.003). The tension band plate constructions could withstand a force at $5^{\circ}$ of coronal tilt less than the two iliosacral screw constructions (p=0.027) and the transiliac fixation plus one iliosacral screw constructions (p=0.049). Conclusions: This study proposes the use of transiliac fixation in addition to an iliosacral screw to stabilize vertically unstable sacral fractures. Our biomechanical data demonstrated the superiority of adding transiliac fixation to withstand vertical displacement forces.

Hydroxyapatite prepared from eggshell and mulberry leaf extract by precipitation method

  • Wu, Shih-Ching;Hsu, Hsueh-Chuan;Hsu, Shih-Kuang;Liu, Mei-Yi;Ho, Wen-Fu
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제4권1호
    • /
    • pp.21-32
    • /
    • 2019
  • Eggshell is a waste material after the usage of egg. In this work, biowaste chicken eggshells were used for preparing carbonated hydroxyapatite (HA) nanoparticles of high purity through aqueous precipitation method at room temperature. The eggshell-derived HA will be a cost-effective bioceramics for biomedical applications and an effective material-recycling technology. Additionally, mulberry leaf extract was used as a template to regulate the morphology, size and crystallinity of HA, and the effects of pH value were also examined. Characterization of the samples was performed by X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy. Scanning electron microscopy (SEM) was used to determine the size, shape and morphology of HA. The results indicate that only one phase of HA were synthesized in the both absence and presence of mulberry leaf extract at pH of 7 and above, while DCPD or DCPA/DCPD phase was observed at pH 4 condition. The crystallite sizes of the HA samples obviously decreased when adding mulberry leaf extract as a template, while they decreased gradually as the solution pH levels increased. With increasing pH level from 7 to 14, the rod-like HA nanoparticles gradually changed to spherical shape at pH 14. Note that, the obtained product is Mg and Sr containing A- and B-type carbonate HA at alkaline pH and it can be a potential material for biomedical applications.

Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro study

  • Bilhan, Selda Arat;Geckili, Onur;Cilingir, Altug;Bozdag, Ergun;Bilhan, Hakan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권4호
    • /
    • pp.199-206
    • /
    • 2019
  • Objectives: In mandibular edentulism, the treatment option with a two-interforaminal implant-retained bridge and a removable partial denture is rarely evaluated in literature. The aim of this in vitro study was to evaluate the stress distribution of this treatment option by comparing it with traditional treatment options with interforaminal implants in the edentulous mandible. Materials and Methods: Two interforaminal implants were placed in a formalin-fixed cadaver mandible, and overdentures with three different types of attachments were fabricated: (1) two ball attachments and an overdenture, (2) a Dolder bar and an overdenture, and (3) screw-retained two-implant inter-canine porcelain fused to a metal bridge and an implant-assisted removable denture (IARD) with precision attachments. Three biting conditions were generated for each denture type, and the strains were documented under vertical loading of 100 N. Results: The calculated strain values from measured strains in all measurement sites and loading conditions for the screw-retained two-implant intercanine porcelain fused to a metal bridge and a cast framework partial denture with precision attachments situation were lower than in the other scenarios (P<0.05). Conclusion: Within the limitations of the present study, it can be concluded that an IARD may be a reasonable and valuable alternative to ball attachments or a bar in two interforaminal implants, especially when the patients prefer to be able to show their teeth even when they take out their removable dentures.

Load response of the natural tooth and dental implant: A comparative biomechanics study

  • Robinson, Dale;Aguilar, Luis;Gatti, Andrea;Abduo, Jaafar;Lee, Peter Vee Sin;Ackland, David
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권3호
    • /
    • pp.169-178
    • /
    • 2019
  • PURPOSE. While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. MATERIALS AND METHODS. A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. RESULTS. For the natural tooth, the maximum vonMises stress (6.4 MPa) and maximal principal strains at the mandible ($1.8m{\varepsilon}$, $-1.7m{\varepsilon}$) were lower than those observed at the prosthetic tooth (12.5 MPa, $3.2m{\varepsilon}$, and $-4.4m{\varepsilon}$, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. CONCLUSION. Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.

Bone Microarchitecture at the Femoral Attachment of the Posterior Cruciate Ligament (PCL) by Texture Analysis of Magnetic Resonance Imaging (MRI) in Patients with PCL Injury: an Indirect Reflection of Ligament Integrity

  • Kim, Hwan;Shin, YiRang;Kim, Sung-Hwan;Lee, Young Han
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권2호
    • /
    • pp.93-100
    • /
    • 2021
  • Purpose: (1) To evaluate the trabecular pattern at the femoral attachment of the posterior cruciate ligament (PCL) in patients with a PCL injury; (2) to analyze bone microarchitecture by applying gray level co-occurrence matrix (GLCM)-based texture analysis; and (3) to determine if there is a significant relationship between bone microarchitecture and posterior instability. Materials and Methods: The study included 96 patients with PCL tears. Trabecular patterns were evaluated on T2-weighted MRI qualitatively, and were evaluated by GLCM texture analysis quantitatively. The grades of posterior drawer test (PDT) and the degrees of posterior displacement on stress radiographs were recorded. The 96 patients were classified into two groups: acute and chronic injury. And 27 patients with no PCL injury were enrolled for control. Pearson's correlation coefficient and one-way ANOVA with Bonferroni test were conducted for statistical analyses. This protocol was approved by the Institutional Review Board. Results: A thick and anisotropic trabecular bone pattern was apparent in normal or acute injury (n = 57/61;93.4%), but was not prominent in chronic injury and posterior instability (n = 31/35;88.6%). Grades of PDT and degrees of posterior displacement on stress radiograph were not correlated with texture parameters. However, the texture analysis parameters of chronic injury were significantly different from those of acute injury and control groups (P < 0.05). Conclusion: The trabecular pattern and texture analysis parameters are useful in predicting posterior instability in patients with PCL injury. Evaluation of the bone microarchitecture resulting from altered biomechanics could advance the understanding of PCL function and improve the detection of PCL injury.

전방십자인대 견열 골절의 관절경적 치료: 성장판을 보존한 All-Inside 교량형 봉합술 (Arthroscopic Treatment of an Anterior Cruciate Ligament Avulsion Fracture: Physeal-Sparing, All-Inside Suture Bridge Repair)

  • 박병문;이승환;양봉석;김지현
    • 대한정형외과학회지
    • /
    • 제55권5호
    • /
    • pp.444-449
    • /
    • 2020
  • 전방십자인대 견열 골절은 주로 소아 및 청소년기에 발생하는 드문 손상으로 전방십자인대의 길이를 유지하여 정상적인 슬관절의 기능을 보존하기 위해서 견열 골편의 정복 및 고정이 필요하다. 이에 다양한 술기가 보고되었으나 성장판이 열려있는 소아에서의 성장판 손상의 위험으로 인해 치료 방법에 논란의 여지가 있다. 저자들은 성장판이 열려있는 소아의 전방십자인대 견열 골절에 봉합 나사못을 이용한 관절경적 교량형 봉합술을 시행하여 성장판의 손상 없이 견고한 고정 및 좋은 임상 결과를 얻어 이를 보고하고자 한다.

Comparative Effects of Novel Modified Sleeper and Cross-body Stretching on Scapular Anterior Tilting and Shoulder Internal Rotation in Subjects With Anterior Tilted Scapular and Shoulder Internal Rotation Deficits

  • Yeonghun Han;Chung-hwi Yi;Woochol Joseph Choi;Oh-yun Kwon
    • 한국전문물리치료학회지
    • /
    • 제30권1호
    • /
    • pp.59-67
    • /
    • 2023
  • Background: Posterior capsule tightness (PCT), commonly seen in overhead athletes, is a soft tissue adaptation that is also noted in non-throwers. PCT is associated with scapular and humeral kinematic alterations, significant restriction of shoulder internal rotation (IR) range of motion (ROM), and significant scapular anterior tilting. Sleeper and cross-body stretches (CBS) are suggested for PCT and IR deficits, and have been modified since introduction. A novel modified sleeper stretch (NMSS) was designed in this study to prevent the risk of anterior translation of the humeral head. Though the effects of posterior shoulder stretching exercise have been widely studies, to the best of our knowledge, no previous studies have investigated the effectiveness of posterior shoulder exercises in decreasing scapular anterior tilting. Objects: To compare the immediate effects of two posterior shoulder stretching exercises (NMSS and CBS) on scapular anterior tilting and shoulder IR ROM. Methods: Thirty-two subjects with anteriorly tilted scapula and IR deficits [mean age: 24.3 ± 2.5 years; 15 males and 17 females] participated in this study. Subjects were randomly assigned to either the NMSS or CBS groups. Scapular anterior tilting (at rest and at shoulder 60° active IR) and shoulder IR ROM were measured before and immediately after intervention. Results: Scapular anterior tilting significantly decreased, while the shoulder IR ROM significantly increased in both groups. However, there was no significant group-by-time interaction effect or significant difference between the groups. Conclusion: Both stretching exercises were effective in restoring shoulder IR ROM and decreasing scapular anterior tilting.

다리근력운동과 유산소운동을 결합한 복합운동이 젊은 성인의 폐활량 및 다리근 활성도에 미치는 영향 (Effects of Combining Lower Extremity Strength Exercise With Aerobic Exercise on Lung Capacity and Lower Extremity Muscle Activity in Young Adults)

  • 이양진;김동우
    • 대한통합의학회지
    • /
    • 제11권2호
    • /
    • pp.69-76
    • /
    • 2023
  • Purpose : This study aimed to compare lung capacity measures (forced vital capacity; FVC, forced expiratory volume at 1 second; FEV1, and FEV1/FVC) and the activities of rectus femoris (RF) and gastrocnemius (GCM) muscles between young adults prescribed aerobic exercise combined with lower limb strength exercise (complex exercise) and those prescribed only aerobic exercise. Methods : We randomly divided 22 young adults into 2 groups: the complex exercise group that combined the leg strengthening and aerobic exercises (n = 11) and the aerobic-exercise-only group (n=11). Before the intervention, the FVC, FEV1, and FEV1/FVC values and the activities of RF and GCM muscles were measured. Measurements were in triplicates, and the average of the 3 measurements was used. The complex exercise group performed the treadmill exercise followed by squats and lunges, and the group performed only the treadmill exercise. Both groups were allocated the same time. Both groups performed the assigned exercise thrice a week for 3 weeks. After the intervention, the FVC, FEV1, and FEV1/FVC values and the activities of RF and GCM muscles were measured again. Results : The FVC and FEV1 values increased significantly in both groups after the intervention (p<.05). RF activity increased significantly after the intervention in the complex exercise group (p<.05), and the magnitude of change in RF activity after the intervention was significantly higher in the complex exercise group than in the aerobic-exercise-only group (p<.05). GCM activity also significantly increased after the intervention in both groups (p<.05). Conclusion : On the basis of our results, we recommend combining leg strengthening and aerobic exercise to improve leg muscle activity along with lung function.

The Effect of Posteroanterior Joint Mobilization Applied to The 3rd Lumbar Vertebra Movement of Adjacent Segmental in Healthy Individuals

  • Kang-O Oh;Sang-Yeol Lee
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권3호
    • /
    • pp.240-250
    • /
    • 2023
  • Objective: The purpose of this study was to characterize the movement of adjacent segments that occurred when posteroanterior joint mobilization was applied to the 3rd lumbar and thereby to provide basic clinical data. Design: Randomized controlled trial design. Methods: While the subjects were receiving posteroanterior joint mobilization of the 3rd lumbar vertebra, LD (lumbar displacement), LID (lumbar intervertebral distance), LIA (lumbar intervertebral angle), and LLA (lumbar lordosis angle) were measured using X-ray, and the data were then analyzed. Changes before and after posteroanterior joint mobilization were analyzed using a paired-sample t-test, and a one-way ANOVA of variance was performed to determine the difference between segmental movements. In addition, Pearson's correlation analysis was performed to determine the correlation between segmental movements. Results: The results revealed that there was a significant change in LD before and after the application of joint mobilization of the 3rd lumbar in all lumbar vertebrae (p<0.000), among which the 2nd lumbar vertebra, an adjacent segment, showed the most significant change. A significant change in LIA angle was observed in all segments (p<0.000), with the most significant change observed between the 2nd and 3rd lumbar vertebrae. There was a significant change in LLA before and after the application of posteroanterior joint mobilization (p<0.000). The correlation analysis showed a high correlation between displacement of the 3rd lumbar vertebra and displacement of all the other lumbar vertebrae. Conclusions: The presence of kinematic movements of the lumbar vertebrae when segmental movements were generated through the application of posteroanterior joint mobilization of the 3rd lumbar vertebra.