• Title/Summary/Keyword: biomechanical factor

Search Result 47, Processing Time 0.025 seconds

Influence of Different Slope Analysis during Pitching Wedge Swing on Plantar Pressure Distribution Pattern (경사면에서 골프스윙 동작시 족저압력 분석)

  • Son, Dong-Ju;Yang, Jeong-Ok;Lee, Joong-Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.297-309
    • /
    • 2009
  • The study analyzed the mechanism of plantar foot pressure distribution during pitching wedge swinging on a flat, an up hill lie and a down hill lie to provide the fundamental information regarding biomechanical motion data by using plantar foot pressure measuring instrument. In the results, time factor spanning according to slope differences, plantar foot pressure factor and swing motion on the slope could have negative effect on the coiling of lower limbs during back swing, as well as the blocking of the lower limbs to minimize the dispersion of the weight and the release of the lower limbs after the impact during the down swing process. Moreover, since slope is one of many external factors affecting swing motion, address motion on an up hill lie limits the lower limbs movement, therefore, a relatively narrow stance is better on a down hill lie. It is estimated that a relatively wide stance would be better in order to limit the bigger activation of the lower limbs. Not only for the address motion but also during the down swing on an up hill lie it is concluded that the weight should be on the left foot in order to keep the body balance.

EXPRESSION OF OSTEOGENESIS RELATED FACTORS ACCORDING TO DISTRACTION RATE IN THE DISTRACTION OSTEOGENESIS (신연 골형성술시 신연속도에 따른 골형성 관여 인자의 발현)

  • Jee, Yu-Jin;Kim, Yeo-Gab
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.250-265
    • /
    • 2008
  • Distraction osteogenesis is a well-established clinical treatment for limb length discrepancy and skeletal deformities. Appropriate mechanical tension-stress is believed not to break the callus but rather to stimulate osteogenesis. In contrast to fracture healing, the mode of bone formation in distraction osteogenesis is primarily intramembranous ossification. Although the biomechanical, histological, and ultrastructural changes associated with distraction osteogenesis have been widely described, the basic biology of the process is still not well known. Moreover, the molecular mechanisms in distraction osteogenesis remain largely unclear. Recent studies have implicated the growth factor cascade is likely to play an important role in distraction. And current reserch suggested that mechanical tension-stress modulates cell shape and phenotype, and stimulates the expression of the mRNA for bone matrix proteins. The purpose of this study is to examine the pattern of expression of growth factors($TGF-{\beta}1$, IGF-I, bFGF) and extracellular matrix proteins(osteoclacin, osteonectin) related to osteogenesis by osteodistraction of the mandible in rabbits. 24 rabbits is used for this experiment. Experimental group are gradual distraction(0.7mm, twice/day), acute distraction(1.4mm, twice/day) and control group is only osteotomized. After 5 days latency, osteotomic site is distracted for each 7 days and 3.5 days. Consolidation period is 28 days. The animal is sacrificed at the 3th, 7th, 14th, 28th. The distracted bone is examined by immunohistochemical analysis and RT-PCR analysis. The results obtained from this study were as follow : No significant difference was found on clinical examination according to distraction rate, but gradual distraction was shown to improve regenerate bone formation on radiographic and histologic examination. Growth factors and extracelluar matrix proteins expression increased in distraction group than control group. From these results, it could be stated that graudal distraction is shown to improve and accelerate bone formation and mechanical stress like distraction has considerable effects on osteogenesis related factors. And rabbit is the most appropriate animal model for further reseach on the molecular mechanisms that mediate osteodistraction. It is believed that understanding the biomolecular mechanisms that mediate distraction osteogenesis may guide the development of targeted strategies designed to improve distraction osteogenesis and accelerate bone healing.

A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE (호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구)

  • Cho, Su-Mi;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

Effect of Whole Body Vibration Training in Drop Landing Jump (전신진동운동이 드랍랜딩점프 동작에 미치는 영향)

  • Hong, Su-Yeon;Jang, Young-Kwan;Kim, Jin-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.423-429
    • /
    • 2018
  • Objective: This study was conducted to investigate the effects of WBVE on biomechanical factor analysis of drop landing jumps before and after a four week training program. Methods: Participants were divided into two group: VEG (n=5, age: $25.7{\pm}2.3yrs$, height: $170{\pm}7.6cm$, weight: $69.3{\pm}8.3kg$) and OEG (n=5, age: $24.6{\pm}3.4yrs$, height: $164{\pm}4.9cm$, weight: $58.8{\pm}9.2kg$). Ten infrared cameras (Vicon, UK) with a sampling rate of 100 Hz were used in two GRF measurement systems (AMTI, USA). Results: The variability of the center of mass was largest at the falling phase, and there was a great risk of injury when landing after the jump. Second, the jumping heights of the VEG (vibration exercise group) were higher than those of the OEG (only exercise group), regardless of training period. Third, there were significant differences in the hip joint P1 (flexion) and knee joint P2 (extension) between the exercise groups after 4 weeks of training. However, there were no significant differences among training periods or phases. Conclusion: regardless of training periods, the VEG showed increased jump height compared with the OEG, but the consistency between the jump height and the lower joint power could not be determined.

A literature review on cementation of implant prosthesis (임플란트 보철물의 합착에 대한 문헌고찰)

  • Lee, Eun-Suk;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.458-467
    • /
    • 2016
  • Cement-retained implant prosthesis has several advantages in the esthetic and occlusal aspects. However, the difficulty of the retrievability and the possibility of peri-implantitis induced by the cement excess would be a threatening factor to the implant prognosis. Peri-implantitis resulting from the remaining cement could occur later on to the patients with periodontitis history. Retention can be controlled by selecting the right cement type. Retention of the cement was the strongest in the resin cement, followed by resin modified glass ionomer cement, poIycarboxylate cement, zinc phosphate cement and glass ionomer cement. Retention of the provisional cement weakened after thermocycling. Other factors such as the abutment number, abutment alignment, height and taper of the abutment can also affect the total retention. To the success of the cement-retained prosthesis, it's important to select the right cement for the clinical purpose. The prosthesis should be fabricated in accordance with the biomechanical requirements. The prosthesis should be cemented with the techniques to reduce the excess cement as much as possible. In addition, the excess cement should be identified using the radiography and carefully removed.

Biomechanical Effectiveness and Anthropometric Design Aspects of 3-dimensional Contoured Pillow

  • Kim, Jong Hyun;Won, Byeong Hee;Sim, Woo Sang;Jang, Kyung Seok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.503-517
    • /
    • 2016
  • Objective: The aim of this study was to evaluate the effectiveness of 3 dimensional contoured pillow through analyzing contact pressure and to suggest its design guidelines through analyzing the posture of head and neck area. Background: The quality of sleep is a very important factor closely related with human's health. To improve the quality of sleep, the verification of design factors affecting the posture of the head and neck is needed, and a pillow design that can induce proper posture is required. Method: This study measured the contact pressures of the two reference groups (bead and cotton pillows) as a method to evaluate the design effectiveness of the contoured pillow. This study proposed 3-dimensional design guidelines by drawing anthropometry (head length) affecting cervical curvature angle (CCA) through the measurement of the participants' cervical curvature angles. Results: In the design effectiveness evaluation, the contact pressure of cervical region was higher than that of a reference group (cotton pillow), and contract area increased, and contract pressure decreased in the shape distributing the occipital region's body pressure. This study proposed pillow's cervical supporting height by percentile of a head length [head length (%tile) (cervical supporting height) affecting the posture of the head and neck: 14.6cm (5%tile) (6.2cm), 15.5cm (25%tile) (6.7cm), 16.4cm (50%tile) (7.1cm), and 19.3cm (75%tile) (8.9cm)]. Conclusion: This study confirmed the contoured pillow's design effectiveness maintaining cervical angle comfortable to sleep with the shape supporting the cervical vertebrae and by reducing the contact load of the occipital region. Also, this study proposed pillow design guidelines based on the 3-dimensional contoured pillow design effectiveness, through which the study laid the foundation for pillow design in a systematic method. Application: The results of this study are expected to be utilized as the basis data by which the optimum pillow type and pillow design according to main percentile can be standardized.

Effect of Knee Joint Injury on Biomechanical Factors during the Uchi-mata (허벅다리걸기 시 무릎 관절 부상이 운동역학적 요인들에 미치는 영향)

  • Hyun Yoon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.4
    • /
    • pp.642-649
    • /
    • 2023
  • The purpose of this study was to analyze the effects of knee joint injury experiences of judo players on kinematic factors and center of pressure factors during uchimata. Among right-handed male college judo players specializing in uchimata, 13 people who had a knee joint injury experience(age, 20.69.1±0.75 years; height, 172.85±4.81 cm; body mass, 74.92±5.51 kg; and career, 8.92±0.95 years) and 13 people who did not have a knee joint injury experience(age, 21.08.1±0.76 years; height, 172.54±6.32 cm; body mass, 76.62±9.09 kg; and career, 9.46±0.94 years) within the last 2 years were divided into two groups and participated as subjects. The two groups were evaluated for differences in ankle, knee, and hip joint angle variables, COP range, and velocity components during uchimata. As a result of the study, the EIG group showed smaller values in the knee joint flexion angle at E3 and the hip joint extension angle at E4 during uchimata than the NIG group. In addition, the EIG group showed lower values in the range of motion of the COP and forward movement velocity of the COP in the one-leg support phase than the NIG group.