• Title/Summary/Keyword: biological informations

Search Result 71, Processing Time 0.022 seconds

Development of Order Communication System - laboratory application - (처방 전달 시스템의 개발 - 검사 처방 시스템의 개발 -)

  • Kim, Jong-Won;Whang, Yoo-Sung;Cha, Eun-Jong;Lee, Tae-Soo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.118-120
    • /
    • 1992
  • We have developed and been using laboratory order communication system which is a computerized laboratory request and reception system wi th bar code between inpatient or outpatient and the clinical laboratory in Chungbuk National Unversity Hospital. Work flows are as follows: Tests are requested by the physicians through hospital information system without issuing request forms. Bar code stickers containing demographics of patient and other informations such as sample number, slip code and specimen code are printed and attached to smaple tubes. At the department of clinical pathology, smaples are received through the bar code reader. Area numbers are automatically created and laboratory work numbers are determined. Worklists can be issued by each section of laboratory when needed. Our order communication system alleviates the human labor such as specimen labelling and making worklist and reduces clerical errors that occur from sample collection to laboratory analysis.

  • PDF

Studies on the Fungal Isolates of Mucorales Collected from Korean Home Made Mejus and Nuluks (한국전통 식품의 원료인 메주와 누룩에서 분리된 접합균에 대한 연구)

  • Yu, Kee-Won;Seoung, Chang-Kun;Lee, Sang-Sun;Yoo, Jin-Young
    • The Korean Journal of Mycology
    • /
    • v.24 no.4 s.79
    • /
    • pp.280-292
    • /
    • 1996
  • The fungal isolates of Mucorales, directly collected from Korean traditional raw materials of Nuruk (raw material for Korean rice wine) and Meju (raw material for Korean soysauces), were compared with those of Rhizopus oryzae purchased. The fungal isolates of Rhizopus, Mucor, and Absidia mostly identified as based on the morphological observations, were evaluated with the PCR-polymorphic bands. The PCR-polymorphic bands of the genomic DNA reacted with the primers of OPD series tenmer were various, but showed averaged 4 to 6 in the agarose-electrophoresis. The dissimilarity coefficient (DC) between two isolates were compared by the cluster analyses, dendrogams and polar ordinations. The isolates of R. oryzae known. showed several groupings within the lower value of DC and were divided to two groups of amylo-process and other fungi with other purposes. The isolates unidentified were identified by the DC made of this results. Taxonomy of these isolates made by the morphological observations were consistent with those resulted above in most case but not in all aspects. More works were needed with the isolates known for detail informations of Mucorales.

  • PDF

Measurements of Auditory Evoked Neuromagnetic Fields using Superconducting Quantum Interference Devices (SQUID를 이용한 뇌 청각유발 자장의 측정)

  • 이용호;권혁찬;김진목;박용기
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.421-428
    • /
    • 1997
  • Magnetic field sensors made from superconducting quantum interference device (SQUID) are the most sensitive low-frequency sensors available, enabling measurements of extremely weak magnetic fields from the brain. Neuromagnetic measurements allow superior spatial resolution, compared with the present electric measurements, and superior temporal resolution, compared with the fMRl and PET, providing useful informations for the functional diagnoses of the brain. We developed a 4-channel SQUID system for neuromagnetic applications. The main features of the system are its simple readout electronics and compact pickup coil structure. A magnetically shielded room has been constructed for the reduction of environmental magnetic noises. The developed SQUID system has noise level lower than the magnetic noise from the brain. Magnetic field signals of the spontaneous r-rhythm activity and auditory evoked magnetic fields have been measured.

  • PDF

Roles of Estrogen in the Reproductive Organs of Male Rodents : Focus on ERKO Mice Model (설치류 수컷 생식기관에서의 에스트로겐 기능 : 에스트로겐 수용체 녹아웃(ERKO) 생쥐 모델을 중심으로)

  • Lee, Sung-Ho;Choi, Don-Chan
    • Development and Reproduction
    • /
    • v.8 no.2
    • /
    • pp.69-75
    • /
    • 2004
  • It has been known for many years that administration of estrogen, a so-called female hormone, has harmful effects on male fertility. However, studies employing transgenic mice deficient in estrogen receptors reveal substantial roles for estrogen in male fertility. The aim of this article is to review and summarize the current knowledge on the estrogen receptor localization in male reproductive organs including male germ cells of rodents. Also, informations about the mice models with disrupted estrogen signaling and associated phenotypes will be provided.

  • PDF

Evaluation of Skin Furrows using Stereo image (Stereo image를 이용한 Skin furrows에 대한 연구)

  • Ahn, H.J.;Kim, M.G.;Moon, J.S.;Oh, Ch.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.36-40
    • /
    • 1996
  • There are two prevailing techniques, mechanical and optical profilometers, to measure 3-dimensional configurations of the human skin furrows. The methods have some limitations such as, accuracies or resolutions of the acquired 3-dimensional data and consistencies according to the repeated experiments. We devised an optical profilometer that is called stereo image optical profilometer (SOP) based on stereo image processing techniques. A stereo image is a pair of images that obtained from two cameras which have different angles. From the digital stereo images, the clinical informations for skin can be obtained by some signal processing techniques. In this paper, we focused on the 3-dimensional graphical visualizations of the structures and state of the skin furrows by solving the corresponding problem from the left and right pairs of the stereo images.

  • PDF

Implementation of Urinary Incontinence Therapy Device with Wireless Bluetooth Communication (무선 요실금 치료기의 구현)

  • Lee, Seung-Jik;Kim, Kyung-Ah;Lee, Tae-Soo;Kim, Wun-Jae;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.197-202
    • /
    • 2006
  • Devices in current market to perform electrical stimulation therapy of the urinary incontinence frequent in aging women are very much impractical to us ε due to the wired configuration. The present study implemented new wireless device to enhance self as well as in-hospital therapy with the easiest and the most convenient application. The therapy system consisted of two modules, called 'master' and 'slave', communicating with each other by the wireless Bluetooth protocol. The patient controls therapy processes on the master module in hand, transmitting the required informations to operate the slave module placed within her pants with the viginal electrode connected, delivering appropriate electrical stimulation. Wireless communication enabled self therapy with clothes on, leading to a great convenience for the patient. The stimulation output signal was comparable to commercialized products in both waveform and stimulation capacity.

Dental implant failures and complications - Retrospective study (치과 임플란트 실패와 합병증의 후향적 연구)

  • Park, Ju-Hee;Jo, Chan Woo;Woo, Jae-Man;Kahm, Se Hoon
    • The Journal of the Korean dental association
    • /
    • v.57 no.7
    • /
    • pp.372-378
    • /
    • 2019
  • The dental implants in modern dentistry brought out a new era in everyday dental practice. Increasing of dental implants usage, various failures and complications has occurred. Failures and complications of dental implant treatments that can happen in implant surgery, in mechanical or prosthetic problem and in biological aspect. The aim of this study was to assess implant failures for 6 years as well as find out how to overcome implant failure. In Jeju National University hospital, 26 dental implants in 17 patients were removed by implant failure through 2013.1.1.-2018.12.31. Each implant failure case was analyzed in report form with various informations about failure retrospectively. The present study showed 26 failed dental implants of 17 patients were removed. 13 implants(50%) of 8 patients(47.06%) were failed before functional loading and 13 implants(50%) of 9 patients(52.94%) were failed after functional loading. 11 implants(42.31%) of 7 patients(41.18%) with medical disease were extracted. 6 implants(23.08%) of 5 patients(29.41%) with additive bone graft were failed. We discuss with 26 failed dental implants of 17 patients about their causes, solutions and prevention retrospectively for 6 past years. Precise diagnosis and treatment planning are needed. Medically compromised patients and patients with implants and additive bone grafts should be cautiously treated with high failing possibilities.

  • PDF

Integrated Network System of Milk Cow Stock-Farming Facilities for Stockbreeding Management (사양관리를 위한 젖소 목장 시설 통합 네트웍 시스템)

  • 김지홍;이수영;김용준;한병성;김동원
    • Journal of Animal Environmental Science
    • /
    • v.8 no.3
    • /
    • pp.199-208
    • /
    • 2002
  • This paper introduces the method to make management network about milking cow farm tasks. The object of this research was to design of biological measuring system and managing network system in a livestock farm. This auto-management system provides informations about individual cows' temperature, conductivity of milk and weight for efficient management of feeding, and milking works by a micro-processor and RS -485 type serial COM. ports. And measured bio-data which are basic informations for remote raising management are saved to user PC by serial communication between the PLC and user PC. Milking cow farm is divided into three working place to each measurement work and feed. The first working place is milking station which has two thermometers, a conduct meter and a scale set. The second working place is feeding station, and the third place is cattle cage. These are combined by network system and the PLC which is used to drive network and sub-modules. Sub-modules have a micro-process to control the sensor and to interface with network. The PLC which drive network and control sequence has two serial communication port to be linked with user PC for sending the measured data and for receiving data. Above all, in this study tells the sequence operating method by the driving scenario of breeding milk cow for livestock auto-management using the PLC and network system.

  • PDF

Effects of Molecular Weights on the Physico-pharmaceutical Properties of Poly-L-glutamic acid-cytarabine Conjugates

  • Kim, Chong-Kook;Kwon, Kyoung-Ae;Jeong, Eun-Ju;Lee, Myung-Gull
    • Archives of Pharmacal Research
    • /
    • v.12 no.2
    • /
    • pp.88-93
    • /
    • 1989
  • In order to obtain some informations about the effect of molecular weight on the release rate of drug from drug carrier, two types of poly-L-glutamic acid (PLGA)-cytarabine (ara-C) conjugates, PLGA-ara-C:I and PLGA-ara-C:II, were synthesized using two types of PLGA having different average molecular weight, 43,000 and 77,800, respectively. The PLGA-ara-C conjugates were synthesized by mixed anhydride method and found to be covalently linked. Both types of conjugates charged negatively at biological pH. The pH-dependent release rate of ara-C was observed in both cases, and the release rate was accelerated in basic, acidic conditions (the k values were 0.015 $day^{-1}$ at pH 7.0, 0.024 $day^{-1}$ at pH 5.0, and 0.059 $day^{-1}$ at pH 9.0 in the case of PLGA-ara-C:I) and in the presence of pretense. The time required for the release of 16.5% of ara-C from PLGA-ara-C:I were 8 hr and 144 hr in the presence and absence of protease, respectively. Although both types of conjugates showed similar drug substitution ratio, they showed different release rates. Between the two types of conjugates, PLGA-ara-C:II showed the faster release rate (0.030 vs 0.042 $day^{-1}$ in pH 7.4 phosphate buffer solution at $37^{\circ}C$) and the smaller activation energy for the release of drug (12.5 vs 7.7 Kcal/mol) than PLGA-ara-C:I. The characteristic effect of molecular weight on the release rates of PLGA-ara-C conjugates suggests that the drug release rate might be effectively controlled over a prolonged period of time by the combined use of the different types of PLGA-ara-C conjugates having different molecular weights.

  • PDF

Dynamic Characteristic Change of the Cerebral Blood Volume in Cats Using Perfusion MR Imaging (MR 관류영상을 이용한 고양이 대뇌 혈류량의 동적특성 변화)

  • 박병래;김학진;전계록
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.243-251
    • /
    • 2004
  • This study was to quantitative analysis compare to dynamic characteristic change of the regional cerebral blood volume (rCBV) after development of cerebral fat embolism in cats using perfusion MR Imaging. Forty-four adult rats were used. Triolein (n = 15), oleic acid (n = 9) and linoleic acid (n = 11) were injected into the internal carotid artery using microcatheter through the transfemoral approach. Polyvinyl alcohol (Ivalon) (n = 9) was injected as a control group. Perfusion MR images were obtained at 30 minutes and 2 hours after embolization, based on T2 and diffusion-weighted images. The data was time-to-signal intensity curve and ΔR$_2$* curve were obtained continuously with the aid of home-maid image proc in.leased significantly at 2 hours compared with those of 30 minutes (P<0.005). In conclusion, cerebral blood flow decreased in cerebral fat embolism immediately after embolization and recovered remarkably in time course. It is thought that clinically informations to dynamic characteristic change of the cerebral hemodynamics to the early finding in cerebral infarction by DWI and PWI