• 제목/요약/키워드: biological algorithm

검색결과 849건 처리시간 0.019초

근전도 검사에서 나타나는 탈신경전위와 종판전위의 구별을 위한 알고리듬 (An Algorithm for Distinction between Denervation Potentials and Endplate Spikes on EMG Diagnosis)

  • 최현배;황윤성;박인선;임재중
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.383-386
    • /
    • 1997
  • In the EMG evaluation, the neuropathy may be diagnosed by a detection of denervation potentials in the group of muscles. These abnomal potentials might be confused with normal endplate spikes. In this paper we present the software algorithm in C, which automatically detects spontaneous activity such as denervation potentials and endplate potentials and distingushes between those potentials. Parameters with statistically significant differences were used for this automated algorithm. It was concluded that the algorithm established in this study will improve accuracy in EMG diagnosis.

  • PDF

Identification and Determination of Oil Pollutants Based on 3-D Fluorescence Spectrum Combined with Self-weighted Alternating Trilinear Decomposition Algorithm

  • Cheng, Pengfei;Wang, Yutian;Chen, Zhikun;Yang, Zhe
    • Journal of the Optical Society of Korea
    • /
    • 제20권1호
    • /
    • pp.204-211
    • /
    • 2016
  • Oil pollution seriously endangers the biological environment and human health. Due to the diversity of oils and the complexity of oil composition, it is of great significance to identify the oil contaminants. The 3-D fluorescence spectrum combined with a second order correction algorithm was adopted to measure an oil mixture with overlapped fluorescence spectra. The self-weighted alternating trilinear decomposition (SWATLD) is a kind of second order correction, which has developed rapidly in recent years. Micellar solutions of #0 diesel, #93 gasoline and ordinary kerosene in different concentrations were made up. The 3-D fluorescence spectra of the mixed oil solutions were measured by a FLS920 fluorescence spectrometer. The SWATLD algorithm was applied to decompose the spectrum data. The predict concentration and recovery rate obtained by the experiment show that the SWATLD algorithm has advantages of insensitivity to component number and high resolution for mixed oils.

256-Channel Trans-Admittance Scanner with Lesion Estimation Algorithm for Breast Cancer Detection

  • Oh, Tong-In;Kim, Kyu-Sik;Lee, Jae-Sang;Woo, Eung-Je;Park, Chun-Jae
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권4호
    • /
    • pp.207-214
    • /
    • 2005
  • Breast cancer detection using electrical impedance techniques is based on numerous experimental findings that cancerous tissues have higher electrical conductivity values than normal tissues. Lately, by taking advantage of the structure of current flows underneath a planar probe of array electrodes, a mathematical formula to find lesions from a measured trans­admittance map has been derived. In order to experimentally validate its mathematical analysis and the suggested lesion estimation algorithm, we developed a 256-channel trans-admittance scanner (TAS) for probing anomalies underneath a planar array of electrodes. In this paper, we describe the design and implementation of the TAS. Its performance together with the lesion estimation algorithm was evaluated using saline phantoms. Further studies are proposed to validate the system on human subjects.

새로운 맥파 인식 알고리즘을 적용한 자동 맥파 시스템에 관한 연구 (A Study on the Auto-diagnosis Plethysmograph by Novel Algorithm for Radial Pulse Detection)

  • 박승환;홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권2호
    • /
    • pp.241-246
    • /
    • 1996
  • This paper describes a new system that detects radial pulse wave and allows the diagnosis of malfunctions of cardiovascular system by analyzing the waveforms with the newly proposed algorithm. The system consists of a sensor part and a data processing part within which a new detection algorithm is incorporated In acquiring radial pulse signal noninvasively, the sensor used in this system is a new combinational fiber-optic sensor which has a detecting Part and a transmitting Part. Also, In order to analyze the characteristics of pulsation quantitatively, the algorithm proposed in this paper is a method that runs in parallel with both the data of ECG and differential pulse simultaneously. these concepts are based upon the idea that thfee Q points of ECG give obious discrimination of one entire period of pulse in any abnormal cases, and newly defined feature lines at the differential counterpart can be used to recogrlize sDme significant points in one period of pulses.

  • PDF

퍼지 Hough 변환에 의한 2-D 심초음파도에서의 좌심실 윤곽 자동검출 (Automatic Detection of Left Ventricular Contour from 2-D Echocardiograms using Fuzzy Hough Transform)

  • 조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권2호
    • /
    • pp.115-124
    • /
    • 1992
  • An algorithm has been proposed for the automatic detection of optimal epiand endocardial left ventricular borders from 2-D short axis echocardiogram which is degraded by noise and echo drop out. For the implementation of the algorithm, we modified Ballard's Generalized Hough Transform which can be applicable only for deterministic object border, and newly proposed Fuzzy Hough Transform method. The algorithm presented here allows detection of object whose exact shapes are unknown. The algorithm only requires an approximate model of target object based on anatomical data. To detect the approximate epicardial contour of left ventricle, Fuzzy Hough Transform was applied to the echocardiogram. The optimal epicardial contour was founded by using graph searching method which contains cost function analysis process. Using this optimal epicardial contour and average thickness imformation of left ventricular wall, the approximate endocardial line was founded, and graph searching method was also used to detect optimal endocardial contour.

  • PDF

24시간 HOLTER ECG에서 QT interval 분석을 위한 새로운 Algorithm에 관한 연구 (A New algorithm for at interval analysis in 24 hour Holter BCG)

  • 윤형로;이윤선;이경중
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.13-14
    • /
    • 1989
  • Prolongation in QT corrected interval (QTc), measured in surface ECG, has been shown in the majority af patients to be marker of bad prognosis in postmyocardial infarction patients (PMIP). Hence it would seem logical that dynamic QTc interval measurement can be a very usefull indicator to stratify prognosis in PMIP. We present a new algorithm for QT as well as for QTP (distance value from Q wave onset to T wave peak) intervals measurement in 24 hour ECG Holter tapes. Validation of the algorithm by hand measurement has been done on first beats of 18 Holter tapes, resulting in a magnitude of deviations between 10 and 15 ms. Application on 24 hour Holter ECG signal has also been done.

  • PDF

미네소타 분류방식에 의한 부정맥 진단 알고리즘에 관한 연구 (A Study on Diagnosis Algorithm of Arrhythmia using Minnesota Code Criteria)

  • 정기삼;신건수;이명호
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권1호
    • /
    • pp.171-178
    • /
    • 1990
  • This paper describes a software algorithm for automatic diagnosis of arrhythmia using the criteria of Minnesota code manual. This algorithm provides more accurate and more objective information to medical doctor by standardizing the criteria of diagnosis of arrhythmia. Because this algorithm doesn't need complicated mathematic processing, it carries out the real-time automatic diagnosis that is very important in clinic. The Decision-Table technology suggests the proper results for the given conditions. So it can express clearly the complicated medical problems those are not solved by the mathematical methods. The Decision-Tables have very simple structure. Therefore, it is very easy to correct or expand the system by adding or correcting some rules.

  • PDF

신경회로망을 이용한 다중 전극 와우각 이식 시스템용 음성처리 알고리즘 (A Neural Speech Processing Algorithm for Multielectrode Cochlear Implant System)

  • 최진영;조진호;이건일
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권1호
    • /
    • pp.83-88
    • /
    • 1990
  • A New speech processing algorithm using neural networks is proposed. We transform input data into frequency domain and process them by neural networks of 22 output neurons which have Bark scale on the ground that the Bark scale is similiar with that of the characteristics of human cochlea. An utilized neural network is multilayer perceptron, and the characteristics of cochlea have it trained by error back propagation learning algorithm. The trained neural networks suffices functions of human cochlea including the effects of automatic gain control, compression and equalization. Simulation results show that the proposed speech processing algorithm has good performance in automatic gain control, compression and equalization.

  • PDF

심전도 신호 P파 검출 알고리즘에 관한 연구 (A New Algorithm for P_wave Detection in the ECG signal)

  • 정희교;김광근;황선철;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.15-18
    • /
    • 1989
  • This paper presents a new algorithm for P-wave detection in the ECG signal. We detect the peak and valley point using significant point extraction algorithm with 9-point derivative. Because P-wave duration is changed according to heart-rates, we search for the R-peak and calculate the R-R interval time prior to the determination of P-wave duration threshold values in order to actively adapt to the change of P duration. We determine the parameters for P-wave detection and then P-peak, P-onset and P-offset are detected by these parameters. The results obtained from the proposed algorithm have detected successively P-wave almost more than 90%.

  • PDF

Snakes를 이용한 흉부 연속영상의 외부윤곽검출 (Locating Chest Boundary in Sequential Images by Snakes)

  • 황용호;최우영
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.236-239
    • /
    • 1997
  • Snakes is an active contour model or representing image contours. To detect chest boundary on thoracic MRI sequences, we proposed a method based on modified greedy algorithm. Because thoracic MRI sequences have a spatial correlation, we added energy term related with spatial correlation to Snakes energy formulation. A measure of shape similarity called the BMD was used to evaluate the accuracy of the algorithm. The average BMD value or the modified algorithm's result is higher than greedy algorithm's.

  • PDF