• Title/Summary/Keyword: biofilter

Search Result 363, Processing Time 0.022 seconds

Utilization of biofilter/photo-catalytic reactor system for the simultaneous treatment of hydrogen sulfide and toluene from waste-air

  • Lim, Kwang-Hee;Ping, Wang Zhi;Lim, Dong-Joon;Lee, Eun-Ju
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.287-292
    • /
    • 2005
  • Transient behavior of biofilter/photo-catalytic reactor system was observed to eliminate both hydrogen sulfide and toluene from waste air at its four sampling ports. The biofilter was packed with a equivolume mixture of granular activated carbon(GAC) and compost as packing media on which Thiobacillus sp. IW and Burkholderia cepacia G4 were inoculated and were fixed. The biofilter/photo-catalytic reactor system was run for eight stages of operation under various operating conditions. As a result the removal efficiencies of hydrogen sulfide and toluene began to decrease from 100% after the inlet loads of hydrogen sulfide and toluene surpassed ca. 100 $S-g/m^{3}/h$ and $161g/m^{3}/h$, respectively, and were rapidly decreased to 60% after the inlet loads of hydrogen sulfide and toluene were increased to 200 $S-g/m^{3}/h$ and $644g/m^{3}/h$, respectively.

  • PDF

Styrene Degradation in a Polyurethane Biofilter Inoculated with Pseudomonas sp. IS-3

  • KIM JAISOO;RYU HEE WOOK;JUNG DONG JIN;LEE TAE HO;CHO KYUNG-SUK
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.6
    • /
    • pp.1207-1213
    • /
    • 2005
  • In a search for bacteria capable of degrading styrene better than previously isolated strains, bacterium IS-3 was isolated from activated sludge and found to be most closely related to Pseudomonas sp. Styrene degradation by this strain was tested in liquid cultures and polyurethane-packed biofilters. In liquid cultures, the rate of styrene degradation by this bacterium increased from 24.93 to $76.53\;{\mu}mol\;g^{-1}\;DCW\;H^{-1}$ for an initial mass range from 8.7 to $34.8{\mu}mol$. The maximum styrene elimination capacity was 580-635 $g/m^{3}\cdot$h at a space velocity (SV) of 50-200/h. The critical elimination capacities guaranteeing $95\%$ removal of the input styrene were determined to be 635, 170, and 38 $g/m^{3}\cdot$h, respectively, at SVs of 50, 100, and 200/h. Kinetic analysis revealed that the maximum styrene elimination velocity ($V_{m}$) for this biofilter was 1,000 g/m$\cdot$h, and the saturation constant ($K_{m}$) was 454 ppmv. Together, these results suggest that a polyurethane biofilter containing Pseudomonas sp. IS-3 could have potential practical applications for the effective removal of styrene gas.

Enhancement of Sewage Treatment Efficiencies by Recirculation in Absorbent Biofilter System (재순환에 의한 흡수성 바이오필터 시스템의 오수처리효율 향상)

  • Kwun, Soon-Kuk;Cheon, Gi-Seol;Kim, Song-Bae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.3
    • /
    • pp.69-76
    • /
    • 2005
  • An Absorbent Biofilter System (ABS) combined with the recirculation process was investigated for the feasible application in additional removing of organics (BOD, SS) as well as nutrients (TN, TP) from small Community wastewater in Korea. Polyurethane biofilter media with high porosity and large surface area were /used for the aerobic system. A part of treated wastewater was recirculated into the anoxic septic tank to promote removal of nutrients. The concentrations of BOD and SS of treated wastewater satisfied the regulations for small on-site wastewater treatment facility (10 mg/L) during the overall experimental period. The effluent concentrations of BOD and SS were decreased with enhancement of removal efficiencies of 95.7 and $96.7\%$. The nitrogen and phosphorus removal efficiencies by the recirculation increased to $52.9\%\;and\;43.2\%$ in average during the overall experimental period, respectively. With the improvement, these values were increased as much as additional 42 and $18\%$ compared with those of non-recirculation. The rates of nitrification and denitrification were enhanced showing $65\~77\%\;and\;42\~92\%$, respectively. The described process modification is a low cost and effective method of enhancing nitrogen and phosphorus removal, especially on existing systems without changing major design components of a treatment facility.

Papermill Wastewater Treatment by Indirect Aerated Submerged Biofilter (호기성 침지여상에 의한 제지폐수처리)

  • Won, Chan-Hee;Kwon, Young-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.1
    • /
    • pp.44-52
    • /
    • 1994
  • The purpose of this experimental research was focused to improve the quality of the effluent and the yielded sludge when the papermill wastewater was treated by the indirect aerated submerged biofilter as a second treatment method of papermill wastewater. Changing the various experimental factors(Nutrient additions or not, HRT, F/M ratio, recirculation ratio, etc) with indirect aerated biofilter, the results obtained are as follows. 1. Because of the microbes concentration could be sustained to $9,000mg/l$ in submerged biofilter and then the volumetric organic loads could be increased to $2.7kg-BOD/m^3/day$(that of activated sludge is $0.8kg-BOD/m^3/day$), the reactor volume can be reduced to one third of the activated sludge treatment. 2. Because of the yield coefficient(Y) and the endogenous decay coefficient(kd) were revealed 0.4 and 0.07/d, the yielded sludge volume was reduced by for compared with that of the activated sludgg process. 3. The concentration of the sloughed sludge in the reactor was 2.62~4.01%, so the thickener could be omitted in the papermill wastewater sludge treatment process. 4. When the operating was conducted at HRT of 4hrs, the treatment efficiencies of BOD and COD were obtained 80% and 70%, Therefore operating time can be reduced to one half of the activated sludge treatment.

  • PDF

Removal Characteristics of H2S in the Biofilter Packed with Activated Carbon/Polyurethane Composite Media (활성탄/폴리우레탄 복합담체를 충전한 바이오필터에서 H2S의 제거특성)

  • Gam, Sang Gyu;Gang, Gyeong Ho;Im, Jin Gwan;Lee, Min Gyu
    • Journal of Environmental Science International
    • /
    • v.13 no.1
    • /
    • pp.47-53
    • /
    • 2004
  • A biofiltration system using activated carbon/polyurethane composite as solid support inoculated with Bacillus sp. was developed for treating a gaseous stream containing high concentrations of H$_2$S. The effects of operating condition such as the influent H$_2$S concentration and the empty bed contact time (EBCT) on the removal efficiency of H$_2$S were investigated. The biofilter showed the stable removal efficiencies of over 99 % under the EBCT range from 15 to 60 sec at the 300 ppmv of H$_2$S inlet concentration. When the inlet concentration of H$_2$S was increased, the removal efficiencies decreased, reaching 95 and 74%, at EBCTs of 10 and 7.5 sec, respectively. The maximum elimination capacity in the biofilter packed with activated carbon/polyurethane composite media was 157 g/m$^3$/hr.

Complex odor removal in pilot-scale biofilter with microorganisms immobilized on polymer gel media (미생물 포괄고정화 담체를 적용한 파일럿 스케일 바이오필터에서의 복합악취 제거)

  • Kim, Sun-Jin;Kim, Tae-Hyeong;Lee, Yun-Hee;Jang, Hyun-Sup;Song, Ji-Hyeon;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.741-750
    • /
    • 2011
  • A pilot-scale biofilter was constructed to discover degradation characteristics of the complex odor discharged from Ansan wastewater treatment plant. Candida tropicalis for volatile organic compounds, sulfur oxidizing bacteria(SOB) for hydrogen sulfide, and bacteria extracted from feces soil were immobilized on a polymer gel media. According to this study, the EBCT was varied from 36 sec to 18 sec. Toluene was removed as 80% along the variations, but it was recovered as 100% within 1 week. All benzene and xylene were removed during the operation while the efficiency of hydrogen sulfur was temporary decreased at 18 sec of EBCT, thereafter it was recovered to 100% within a week. The maximum elimination capacities of the benzene, toluene, xylene, and hydrogen sulfur were 6.6 g/$m^{3}$/hr, 31.7 g/$m^{3}$/hr, 7.8 g/$m^{3}$/hr, and 133.6 g/$m^{3}$/hr, respectively. There were merits on removal both organic and inorganic complex odor using the pilot-scale biofilter embedded with microorganisms immobilized on polymer gel media.

Macro-Kinetics of Biofiltration for Odor Control:Dimethyl Disulfide

  • Kim, Jo-Chun;Bora C. Arpacioglu;Eric R. Allen
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E3
    • /
    • pp.165-174
    • /
    • 2002
  • A dual -column biofilter system with two different composts was used to investigate the macro-kinetics of dim-ethyl disulfide (DMDS) degradation. The biofilter columns were filled with compost mixtures up to one meter, The gas How rate and DMDS concentration to the biofilters were varied to study their effect on the removal characteris-tics of DMDS. It was found that the biodegradation of DMDS was governed by zero-order reaction -limited macro-kinetics for inlet DMDS concentrations between 10 and 55 ppmv. The overall average zero-order kinetic coeffi-cient for DMDS removal by compost was 0.50 ($\pm$0.1) ppm/sec for both compost mixtures studied. Variations in individual kinetic coefficients were observed due to varying environmental conditions, such as pH and temperature. The kinetic coefficients determined are specific to the system discussed in this work. During high acidity conditions in the filter beds, methyl mercaptan (MM) was observed in the gas samples collected. Appearance of MM was pro-bably due to decreased microbial activity in the lower portions of the biofilter. Considering the neutral pH range required and the presence of methyl mercaptan, it is likely that the microorganisms present in the biofilters used in this research are similar to the T. thioparus (strain E6) species.

Control of Odor Emissions Using Biofiltration: A Case Study of Dimethyl Disulfide

  • Kim, Jo-Chun;Bora C. Arpacioglu;Eric R. Allen
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E3
    • /
    • pp.153-163
    • /
    • 2002
  • A laboratory- scale dual-column biofilter system was used to study the biofiltration of dimethyl disulfide (DMDS). The gas flow rate and DMDS concentration to the biofilter were varied to study their effect on the remov-al of dimethyl disulfide. Operating parameters such as pH, temperature, and water content were monitored during the biofilter operation and necessary precautions were taken to keep these parameters within the acceptable limits. It was observed that the removal efficiency of DMDS was optimal at neutral pH values. After five month op-eration, the neutralization of the filter beds with sodium carbonate became necessary for the optimum operation of the biofilters. The microbial population already present in the compost mixtures was found to be adequate in treat-ing DMDS. The compost mixtures were found to be similar in terms of biofiltration efficiency of DMDS. However, pressure drops observed in the first column compost mixture (compost/ peat mulch) was extremely high, making this compost economically not feasible. The second mixture (compost/bark) provided pressure drops within accept-able limits. A minimum residence time of 30 seconds at the optimal operating conditions appeared to be adequate for achieving high removal efficiencies (>90%).

Removal of Hydrogen Sulfide using Reticulated Polyurethan Carrier in Biofilter (망상구조 폴리우레탄 담체를 이용한 황화수소 제거)

  • Jeong, Gwi-Taek;Lee, Gwang-Yeon;Cha, Jin-Myoung;Park, Don-Hee
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.372-377
    • /
    • 2007
  • In order to assess its capability as biofilter bed material under variable conditions of two parameters (inlet gas concentration and inlet gas flow rate), reticulated polyurethan was applied to remove hydrogen sulfide via a biological process. We detected a maximal elimination capacity (critical loading rate) of $488.3(330.1)g-H_2S/m^3{\cdot}hr$, when reticulated polyurethane was employed as supporting material of biofilter. This study show that the application of reticulated polyurethane carrier might be a favorable choice as a packing material in biofilter for the biological removal of hydrogen sulfide.

Removal of Hydrogen Sulfide by Biofilter Media (담체 종류에 따른 황화수소의 제거특성)

  • Cha, Gyusuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.4
    • /
    • pp.41-45
    • /
    • 2007
  • It is very important that selection of packing media with large surface area, high limited back pressure in biofilter. The object of this study is the isolation of sulfur-oxidizing bacteria and the removal of hydrogen sulfide in biofilter by media. This investigation led to the following results: 1) we isolated Thiobacillus sp. IW. at an abandoned coal mine in Hwasun, Jeonnam Province. 2) The inorganic media showed better results than the organic media from experiments looking at removal characteristics and changes in pressure drop using various media. 3) Among the inorganic media, fibril and PU media showed best performance.

  • PDF