• Title/Summary/Keyword: bioequivalence test

Search Result 200, Processing Time 0.027 seconds

Bioequivalence of LG Clarithromycin Tablet to Klaricid Tablet (Clarithromycin 250 mg) (클래리시드 정(클래리스로마이신 250mg)에 대한 LG클래리스로마이신 정의 생물학적 동등성)

  • Kim, Soo-Jin;Sim, Young-Sun;Lim, Dong-Koo;Oh, In-Joon;Shin, Sang-Chul;Suh, Soon-Pal;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.3
    • /
    • pp.235-240
    • /
    • 1999
  • Bioequivalence of two clarithromycin tablets, the $Klaricid^{TM}$ (Ciba-Geigy Korea Ltd., Seoul, Korea) and the LG clarithromycin (LG Chemical Co., Ltd., Seoul, Korea), was evaluated according to the Korean Guidelines for Bioequivalence Test (KGBT 1998). Sixteen normal male volunteers $(20{\sim}26\;years\;old)$ were randomly divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one tablet containing 250 mg of clarithromycin was orally administered, blood sample was taken at predetennined time intervals, and the concentrations of clarithromycin in serum were detennined using HPLC method with electrochemical detector. The pharmacokinetic parameters $(AUC_t,\;C_{max}\;and\; T_{max})$ were calculated and ANOVA was utilized for the statistical analysis of parameters. The results showed that the differences in $AUC_t$, $C_{max}$, and $T_{max}$ between two tablets based on $Klaricid^{TM}$ tablet were 4.06%,2.67% and -9.70%, respectively. The powers $(1-{\beta})$ for $AUC_t$, $C_{max}$ and $T_{max}$ were 83.53%, 92.34% and 96.64%, respectively. Detectable differences $({\Delta})$ and 90 % confidence intervals $(a=0.05) $were all less than ${\pm}20%$. All the parameters above met the criteria of KGBT 1998, indicating that LG clarithromycin tablet is bioequivalent to $Klaricid^{TM}$ tablet.

  • PDF

Bio-Equivalence Analysis using Linear Mixed Model (선형혼합모형을 활용한 생물학적 동등성 분석)

  • An, Hyungmi;Lee, Youngjo;Yu, Kyung-Sang
    • The Korean Journal of Applied Statistics
    • /
    • v.28 no.2
    • /
    • pp.289-294
    • /
    • 2015
  • Linear mixed models are commonly used in the clinical pharmaceutical studies to analyze repeated measures such as the crossover study data of bioequivalence studies. In these models, random effects describe the correlation between repeated outcomes and variance-covariance matrix explain within-subject variabilities. Bioequivalence analysis verifies whether a 90% confidence interval for geometric mean ratio of Cmax and AUC between reference drug and test drug is included in the bioequivalence margin [0.8, 1.25] performed using linear mixed models with period, sequence and treatment effects as fixed and sequence nested subject effects as random. A Levofloxacin study is referred to for an example of real data analysis.

Bioequivalence of Procezil Tablet 250 mg to $Cefzil^{(R)}$ Tablet 250 mg (Cefprozil 250 mg) (세프질$^{(R)}$ 정 250밀리그람 (세프프로질 250밀리그람)에 대한 프로세질 정 250밀리그람의 생물학적동등성)

  • Kim, Se-Mi;Kang, Min-Sun;Cho, Hea-Young;Lee, Yong-Bok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.255-261
    • /
    • 2010
  • Cefprozil is a broad-spectrum oral beta-lactam cephalosporin consisting of cis- and trans-isomeric mixture whose ratio is approximately 90:10. Cefprozil is used to treat certain infections caused by bacteria such as bronchitis and ear, skin, and throat infections. The purpose of the present study was to evaluate the bioequivalence of two cefprozil tablets, $Cefzil^{(R)}$ tablet 250 mg (BMS Pharmaceutical Korea., Ltd.) and Procezil tablet 250 mg (Hanmi Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The in vitro release of cefprozil from the two cefprozil formulations were tested using KP VIII Apparatus I method with water dissolution media. Thirty five healthy male subjects, $24.00{\pm}1.53$ years in age and $69.77{\pm}9.99$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After four tablets containing 1000 mg as cefprozil were orally administered, blood samples were taken at predetermined time intervals and the concentrations of cefprozil in serum were determined using HPLC/UV detector. The dissolution profiles of two formulations were similar in water tested dissolution media. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ on the basis of total-cefprozil were calculated, and computer program (K-BE Test 2002) was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Cefzil^{(R)}$ tablets, were -0.81%, -3.00% and -6.83% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., log 0.9515~log 1.0454 and log 0.9613~log 1.0465 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Procezil tablet was bioequivalent to $Cefzil^{(R)}$ tablet.

Development of BioEquiv, a Computer Program for the Analysis of Bioequivalence (생물학적동등성시험을 위한 통계처리 프로그램(BioEquiv)의 개발)

  • Yoon, Sang-Hoo;Hwang, Nan-A;Lim, Young-Chai;Lee, Yong-Bok;Park, Jeong-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • K-$BEtest^{(R)}$ is a well known program for bioequivalence test using a $2{\times}2$ design. Lee et al.(1998) and Park et al.(1999) suggested a $3{\times}3$ and $3{\times}2$ design, and also discussed their benefits. We developed a computer program, called BioEquiv, which can analyze some complex experimental designs such as, $3{\times}3$ design and $3{\times}2$ design including a standard $2{\times}2$ design. This program is a user-friendly one and overcomes the disadvantages of K-$BEtest^{(R)}$. The detailed statistical formula and structure of BioEquiv are presented with some examples. The comparison between K-$BEtest^{(R)}$ and BioEquiv are given with actual data analysis. BioEquiv is able to present a table of ANOVA test over some complex experimental designs. Moreover K-$BEtest^{(R)}$ and BioEquiv draw the same result when data consists of $2{\times}2$ design.

Bioequivalence and Pharmacokinetics of 70 mg Alendronate Sodium Tablets by Measuring Alendronate in Plasma

  • Yun Min-Hyuk;Woo Jong-Su;Kwon Kwang-Il
    • Archives of Pharmacal Research
    • /
    • v.29 no.4
    • /
    • pp.328-332
    • /
    • 2006
  • The bioequivalence and pharmacokinetics of alendronate sodium tablets were examined by determining the plasma concentration of alendronate. Two groups, consisting of 24 healthy volunteers, each received a 70 mg reference alendronate sodium tablet and a test tablet in a $2{\times}2$ crossover study. There was a 6-day washout period between doses. The plasma alendronate concentration was monitored for 7 h after the dose, using HPLC-Fluorescence Detector (FD). The area under the plasma concentration-time curve from time 0 to the last sampling time at 7 h $(AUC_{0-7h})$ was calculated using the linear-log trapezoidal rule. The maximum plasma drug concentration $(C_{max})$ and the time to reach $C_{max}(T_{max})$ were derived from the plasma concentration-time data. Analysis of variance was performed using logarithmically transformed $AUC_{0-7h}\;and\;C_{max}$, and untransformed $T_{max}$. For the test medication versus the reference medication, the $AUC_{0-7h}\;were\;87.63{\pm}29.27\;vs.\;102.44{\pm}69.96ng\;h\;mL^{-1}$ and the $C_{max}$ values were $34.29{\pm}13.77\;vs.\;38.47{\pm}24.39ng\;mL^{-1}$ respectively. The $90\%$ confidence intervals of the mean differences of the logarithmic transformed $AUC_{0-7h}$ and $C_{max}$ values were log 0.8234-log 1.1597 and log 0.8222-log 1.1409, respectively, satisfying the bioequivalence criteria guidelines of both the US Food and Drug Administration and the Korea Food and Drug Administration. The other pharmacokinetic parameters for the test drug versus reference drug, respectively, were: $t_{1/2},\;1.87{\pm}0.62\;vs.\;1.77{\pm}0.54\;h;\;V/F,\;2061.30{\pm}986.49\;vs.\;2576.45{\pm}1826.05\;L;\;CL/F,\;835.32{\pm}357.35\;vs.\;889.48{\pm}485.87\;L\;h^{-1}; K_{el},\;0.42{\pm}0.14\;vs.\;0.40{\pm}0.18\;h^{-1};\;Ka,\;4.46{\pm}3.63\;vs.\;3.80{\pm}3.64\;h^{-1};\;and\;T_{lag},\;0.19{\pm}0.09\;vs.\;0.18{\pm}0.06\;h$. These results indicated that two alendronate formulations(70-mg alendronate sodium) were biologically equivalent and can be prescribed interchangeably.

Bioequivalence Assessment of Acephyll® Capsule to Surfolase® Capsule (Acebrophylline HCl 100 mg) by Liquid Chromatography Tandem Mass Spectrometry

  • Nam, Kyung-Don;Seo, Ji-Hyung;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.5
    • /
    • pp.309-315
    • /
    • 2011
  • A sensitive and specific liquid chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) was developed for the analysis of ambroxol (active moiety of acebrophylline). After acetonitrile precipitation of proteins from plasma samples, ambroxol and the domperidone (internal standard, IS) were eluted on a C18 column. The isocratic mobile phase was consisted of 10 mM ammonium acetate and methanol (10 : 90, v/v), with flow rate at 0.2 mL/min. A tandem mass spectrometer, as detector, was used for quantitative analysis in positive mode by a multiple reaction monitoring mode to monitor the m/z 379.2${\rightarrow}$264.0 and the m/z 426.2${\rightarrow}$175.1 transitions for ambroxol and the IS, respectively. Twenty four healthy Korean male subjects received two capsules (100 mg ${\times}$ 2) of either the test or the reference formulation of acebrophylline HCl in a 2 ${\times}$ 2 crossover study, this was followed by a 1week washout period between either formulation. $AUC_{0-t}$ (the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. The 90% confidence intervals for the log transformed data were acceptable range of log 0.8 to log 1.25 (e.g., log 0.8964 - log 0.9910 for $AUC_{0-t}$ log 0.8690 - log 1.0750 for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of Korea Food and Drug Administration for bioequivalence indicating that Acephyll$^{(R)}$ capsule (test) is bioequivalent to Surfolase$^{(R)}$ capsule (reference).

Bioequivalence of Cyclosporin A Hard Capsules (사이클로스포린 A 경질캅셀제에 대한 생물학적 동등성 평가)

  • 김종국;이은진;이미경;박준규;신희종;김인숙
    • Biomolecules & Therapeutics
    • /
    • v.6 no.3
    • /
    • pp.296-302
    • /
    • 1998
  • The bioequivalence of two cyclosporin A products was evaluated in 26 normal male volunteers (age 25 ~33 yr, body weight 56~84 kg) following single oral administration. Test product was a hard capsule containing the granule of cyclosporin A (Chong Kun Dang Corp., Korea) and reference product, Sandimmun", was a soft capsule containing surfactant, oil, alcohol and cyclosporin A (Sandoz, Swiss). Both products contain 100 mg of cyclosporin A. Four capsules of the test and the reference product were administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). Average drug concentrations at each sampling time and pharmacokinetic parameters were not significantly different between two products (p>0.05); the area under the concentration-time curve to last sampling time (24 hr) (AU $Co_{24}$) (5034.8$\pm$ 1760.6 vs 4635.4$\pm$ 1158.9 ng . h/ml), maximum plasma concentration ( $C_{max}$) (1002.7$\pm$353.1 vs 980. 4$\pm$ 171.7 ng/71), and mean residence time (MRT) (6.16$\pm$0.81 vs 5.64$\pm$0.50 h). The differences of mean AUC 7-,4,7~, T_ and MRT between the two products (7.93,2.22,16 and 8.39%, respectively) were less than 20% given as a guideline. The power (1-$\beta$) and treatment difference ($\Delta$) for AU $Co_{24}$, $C_{max}$ and MRT were more than 0.8 and less than 0.2, respectively. Although $T_{max}$ of the two products was significantly different each other (p<0.05), $T_{max}$ might be an insignificant parameter because cyclosporin A generally requires long-term administration. From these results, the two products are bioequivalent.alent.t.

  • PDF

Bioequivalence and Pharmacokinetics of Carvedilol (25mg) Tablets in Volunteers (카베딜롤(25mg)정제의 생물학적 동등성 및 약물동태연구)

  • 우수경;김호순;강종성;권광일
    • YAKHAK HOEJI
    • /
    • v.45 no.6
    • /
    • pp.650-655
    • /
    • 2001
  • Carvedilol is a nonselective $\beta$-blocking agent with vasodilating properties that are attributed mainly to its blocking activity at $\alpha$$^{1}$-receptors. Carvedilol is used in the treatment of mild to moderate hypertention and angina pectoris and is often used in combination with other drugs. This study was carried out to evaluate the bioequivalence and pharmacokinetics of two carvedilol 25mg tablet formulations according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty healthy volunteers are enrolled and received a single dose (25mg as carvedilol) of each drug in the fasting state, in a randomized 2-way crossover design. After oral administration, blond samples were collected for a period of 30 hours. Plasma concentrations of carvedilol were determined by a rapid and sensitive HPLC method with spectrofluorometric detection. The major pharmacokinetic parameters such as AU $C_{0-}$30hr/, AU $C_{inf}$ , $C_{max}$, $T_{max}$, $t_{1}$2 / Cl/F and V $_{\beta}$//F were calculated. ANOVA test and t-test were utilized for the statistical analysis of each parameter. The results showed that the differences in AU $C_{0-}$30hr/, $C_{max}$ and $T_{max}$ between two were ~5.66, 1.74 and 0.00%, respectively. Minimum detectable differences ($\Delta$) at $\alpha$=0.05 were less than$\pm$ 20% except $T_{max}$ (8.44, 18.36, and 33.86%, respectively). The 90% confidence intervals of all parameters were within $\pm$20% (-10.60~ -0.72, -9.00~12.49 and -19.81~19.81%, respectively). Therefore, it is concluded that the two formulations are bioequivalent for both the extent and the rate of absorption after single dose administration.ation.ion.ion.ation.ion.n.

  • PDF

Development and validation of LC-MS/MS for bioanalysis of hydroxychloroquine in human whole blood

  • Park, Jung Youl;Song, Hyun Ho;Kwon, Young Ee;Kim, Seo Jin;Jang, Sukil;Joo, Seong Soo
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.130-139
    • /
    • 2018
  • This study aimed to analyze a high-performance liquid chromatography (HPLC) separation using a pentafluorophenyl column of parent drug hydroxychloroquine (HCQ) and its active metabolite, desethylhydroxchloroquine (DHCQ) applying to determine bioequivalence of two different formulations administered to patients. A rapid, simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for bioanalysis of HCQ and its metabolite DHCQ in human whole blood using deuterium derivative $hydroxychloroquine-D_4$ as an internal standard (IS). A triple-quadrupole mass spectrometer was operated using electrospray ionization in multiple reaction monitoring (MRM) mode. Sample preparation involves a two-step precipitation of protein techniques. The removed protein blood samples were chromatographed on a pentafluorophenyl (PFP) column ($50mm{\times}4.6mm$, $2.6{\mu}m$) with a mobile phase (ammonium formate solution containing dilute formic acid) in an isocratic mode at a flow rate of 0.45 mL/min. The standard curves were found to be linear in the range of 2 - 500 ng/mL for HCQ; 2 - 2,000 ng/mL for DHCQ in spite of lacking a highly sensitive MS spectrometry system. Results of intra- and inter-day precision and accuracy were within acceptable limits. A run time of 2.2 min for HCQ and 2.03 min for DHCQ in blood sample facilitated the analysis of more than 300 human whole blood samples per day. Taken together, we concluded that the assay developed herein represents a highly qualified technology for the quantification of HCQ in human whole blood for a parallel design bioequivalence study in a healthy male.

Analysis of Perception on the Bioequivalence-assured Generic Drugs (생물학적동등성 인정 제네릭의약품에 대한 인식도 분석)

  • Lee, Eui-Kyung;Kim, Dong-Sook
    • Korean Journal of Clinical Pharmacy
    • /
    • v.16 no.2
    • /
    • pp.139-146
    • /
    • 2006
  • Objectives: Bio-equivalence(BE) test is important not only to ensure the quality of generic drugs, but also to promote drug substitution under the separation of prescribing and dispensing practice(SPD). This study was intended to investigate the perception of consumers, doctors, and pharmacists on the confidence of bio-equivalence(BE) assured drugs. Methods: Nation-wide telephone interview survey was conducted for 1,018 consumers, 800 doctors, and 806 pharmacists from September to October in 2003. Descriptive analysis and ${\chi}^2$ analysis were conducted. Results: Even though people showed higher confidence level for the Bioequivalent drugs compared with Bio-inequivalent drugs, the confidence was generally low. Among those asked about the therapeutic substitutability of original drugs by BE versions, 95.78% of pharmacists responded "positive", while only 39.33% of consumers and 31.13% of doctors said so. The elderly, the less educated, who takes chronic disease medicine, pays high cost of prescription drugs, and are in the low income responded less aware of that. Also most consumers got information such as effect of drugs from either media or doctors. Conclusions: In order for people to believe that BE drugs and original drugs are equivalent, we need to strengthen health education, and to clarify any misunderstanding. It is also necessary for the national policy to provide accurate information about drugs to the public.

  • PDF