• Title/Summary/Keyword: bioelectrical impedance

Search Result 171, Processing Time 0.025 seconds

Development of Bioelectrical Impedance Analyzer for Korean in Telemedicine (원격의료계측을 위한 한국형 생체 전기 임피던스 분석 시스템의 개발)

  • 문재국;서광석;임택균;신태민;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.413-418
    • /
    • 2002
  • The purpose of this study was to design a single frequency BIA(Bioelectrical Impedance Analyzer) which can measure body impedance when patient is sitting on the toilet and to develope a prediction equation for designed BIA. For the purpose of this study, we acquired body impedances with designed BIA from 181 subjects composed of healthy Korean by attaching electrodes to suitable positions(wrist and thigh) for toilet measurement. We computed an appropriate FFM(Fat Free Mass) for Korean using modified-Siri equation to the same subjects instead of Siri equation which nay cause accuracy problems in hydrodensitometry when it applied to Korean. We used this FFM as reference value and developed a Korean FFM prediction equation based on body impedance index, body weight and sex. Correlation coefficient between prediction value and reference value of FFM was extremely high (r = 0.977) and SEE(Standard Error of Estimation) was low 2.47kg.(p<0.05) For comparison between existing electrode-attaching method and our method for toilet measurement, we acquired body impedance with designed BIA from same subjects attaching electrodes on existing positions (wrist and ankle) and made FFM prediction equation for BIA. Correlation coeffient between predicted value and reference value was 0.978 and SEE was 2.43kg(p<0.05). It means that the developed system has not significant differences with existing method. In conclusion bioelectrical impedance analyzer and the FFM prediction equation developed in this paper are evaluated to he adequate to compute FFM of Korean.

Development of Bioelectric Impedance Measurement System Using Multi-Frequency Applying Method

  • Kim, J.H.;Jang, W.Y.;Kim, S.S.;Son, J.M.;Park, G.C.;Kim, Y.J.;Jeon, G.R.
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.368-376
    • /
    • 2014
  • In order to measure the segmental impedance of the body, a bioelectrical impedance measurement system (BIMS) using multi-frequency applying method and two-electrode method was implemented in this study. The BIMS was composed of constant current source, automatic gain control, and multi-frequency generation units. Three experiments were performed using the BIMS and a commercial impedance analyzer (CIA). First, in order to evaluate the performance of the BIMS, four RC circuits connected with a resistor and capacitor in serial and/or parallel were composed. Bioelectrical impedance (BI) was measured by applying multi-frequencies -5, 10, 50, 100, 150, 200, 300, 400, and 500 KHz - to each circuit. BI values measured by the BIMS were in good agreement with those obtained by the CIA for four RC circuits. Second, after measuring BI at each frequency by applying multi-frequency to the left and right forearm and the popliteal region of the body, BI values measured by the BIMS were compared to those acquired by the CIA. Third, when the distance between electrodes was changed to 1, 3, 5, 7, 9, 11, 13, and 15 cm, BI by the BIMS was also compared to BI from the CIA. In addition, BI of extracellular fluid (ECF) was measured at each frequency ranging from 10 to 500 KHz. BI of intracellular fluid (ICF) was calculated by subtracting BI of ECF measured at 500 kHZ from BI measured at seven frequencies ranging from 50 to 500 KHz. BI of ICF and ECF decreased as the frequency increased. BI of ICF sharply decreased at frequencies above 300 KHz.

Validation of Segmental Multi-Frequency Bioelectrical Impedance Analysis based on the Segmental Bioelectrical Impedance analysis in the Elderly Population (분절임피던스를 기준한 분절다주파수 생체임피던스의 일치도 분석)

  • Tang, Sae-Jo;Kim, Jang-Hee;Eom, Jin Jong;Eom, Sunho;Kim, Hakkyun;Kim, Chul-Hyun
    • Journal of Platform Technology
    • /
    • v.9 no.2
    • /
    • pp.38-45
    • /
    • 2021
  • A frequently used bioimpedance analytical method in Korea is the segmental multi-frequency BIA (SMF-BIA) method, but it is not directly determined at a segmented impedance. This study was to compare SMF-BIA determinations with direct segmented determinations for accuracy and appropriateness of segment parameters. This study is to compare the segment parameters, accuracy and appropriateness of the multi-frequency segmental bioimpedance analysis. To this end, 108 elderly individuals were measured. Segmented bioelectrical measurements obtained from a SMF-BIA (Inbody S10) at 50 kHz and measured with a phase sensitive single frequency device (SF-BIA, bia-101, RJL / akern systems) were compared. The significant difference (%) was demonstrated between single - and multiple frequency determinations of the right upper limb (R = 35.5 ± 6.2%, P < 0.001; Xc = 2.7 ± 7.6%, P < 0.01), left upper limb difference (R= 33. 9 ± 6.0%, P < 0.001; Xc = 2.8 ± 8.3%, P < 0.01), right lower limb difference (R = 18.6 ± 4.3%, P < 0.001; Xc = 25.8 ± 10.0%, P < 0.001), left lower limb difference (R = 18.0 ± 4.7%, P < 0.001; Xc = 31.8%). Of the results determined with the two BIA methods, the impedance measurements of the limbs and whole body showed a high correlation (RA: R = 0. 950, LA: R = 0. 949, RL: R = 0.899, LL: R = 0.88), and in the agreement test, the impedance values of the upper limbs and whole body also showed strong agreement (ICC > 0.9), but in the Xc, the correlation was weak. In conclusion, it was found that although bioimpedance devices had significantly different characteristics and inconsistent cross sectionally, there was a high population level agreement in the upper and lower extremities in determining segmental resistance value changes. But a large error was found on the trunk. Further studies were needed for reducing the error.

Predicting body compositions of live finishing pigs based on bioelectrical impedance analysis

  • An, Ji Seon;Lee, Ji Hwan;Song, Min Ho;Yun, Won;Oh, Han Jin;Kim, Yong Ju;Lee, Jun Soeng;Kim, Hyeun Bum;Cho, Jin Ho
    • Journal of Animal Science and Technology
    • /
    • v.63 no.2
    • /
    • pp.332-338
    • /
    • 2021
  • The objective of this study was to predict body compositions of live pigs using bioelectrical impedance procedures. In experiment 1, 32 crossbred (Duroc × Landrace × Yorkshire) finishing pigs with an average weight at 84.06 kg were used. In experiment 2, 96 crossbred (Duroc × Landrace × Yorkshire) finishing pigs with an average weight at 88.8 kg were used. A four-terminal body composition analyser was utilized to determine fat percentage. Lean meat percentage and backfat thickness were measured with a lean meat measuring meter. In experiment 1, fat percentage was not significantly correlated with lean meat percentage, although a tendency (p < 0.1) of a negative correlation was found. Backfat thickness was significantly correlated with fat percentage and lean meat percentage (r = 0.745 and r = -0.961, respectively). Coefficients of determination for fat percentage with lean meat percentage, fat percentage with backfat thickness, and backfat thickness with lean meat percentage were 0.503, 0.566, and 0.923, respectively. In experiment 2, fat percentage was significantly correlated with lean meat percentage (r = -0.972). Backfat thickness was also significantly correlated with fat percentage and lean meat percentage (r = 0.935 and r = -0.957, respectively). Results of this study indicate that bioelectrical impedance analysis might be useful for predicting body compositions of live finishing pigs.

Effective Body Signal Measurement with the Bioelectric Impedance Analysis (생체 전기 신호에 의한 효율적인 생체 신호 측정)

  • Oh, Se-Yong;Hwang, Dae-Seok;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.955-958
    • /
    • 2005
  • Bioelectrical Impedance Analysis(BIA) can measure body water amount and then body fat mass. The formula is used here FFM=-4.104+0.518H+0.231W+0.130X+4.229S is used, In this work, H is height, R is resistance value, W is weight, X is reactance and S is distinction of sex.

  • PDF

Effective Body Signal Measurement with the Bioelectric Impedance Analysis (효율적인 생체 임피던스 신호 측정에 관한 연구)

  • Oh, Se-Yong;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.689-692
    • /
    • 2005
  • Bioelectrical Impedance Analysis(BIA) can measure body water amount and then body fat mass. Locate 4 electrode in palm to measure efficiently and flow current(50kHz, 800uA) in body for measuring voltage and capacitance. And proposed method to measure body fat with hight, weight, age and distinction of sex.

  • PDF

Indirect Assessment of Obesity by Physical Indices and Bioelectrical Impedance Analysis on Junior High School Boys and Girls in Taegu and Kyungpook Province (대구.경북지역 남녀 중학생의 체격지수 및 생체 전기저항 측정법에 의한 비만 판정)

  • 장현숙;차진이
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.9 no.2
    • /
    • pp.115-124
    • /
    • 1999
  • The purpose of this study was to investigate the prevalence of obesity in urban and rural junior high school students. Height, weight, skinfold thickness and bioelectrical impedance were measured. The results obtained were summarized as follows : The average height and weight of boys were respectively 159.61cm 50.56kg and those of girls were respectively 155.88cm, 48.12kg. The percentage of obesity was respectively 6.20%, 10.22%, 5.47%, 17.15%, 14.60% for boys and 4.38%. 9.69%, 3.13%, 3.75%, 7.19% for girls by BMI, RI. OI, % body fat I, % body fat II. The rates of obesity were higher in boys than in girls, so nutritional education on obesity for boys is especially necessary. 21.09% of boys and 7.04% of girls in urban and 7.09% of boys and 7.48% of girls in rural were obese. Correlation coefficients between TC(triceps skinfold thickness + calf skinfold thickness) and BMI, RI, OI, % body fat I and % body fat II were 0.66, 0.67, 0.67, 0.77, 0.70.

  • PDF

Development of Multi-Frequency Impedance Measurement System for Acupuncture Points and Preliminary Report of Measurement Results (Multi-frequency 자극 방식을 이용한 생체 전기 임피던스 측정 시스템 설계 및 경혈의 전기적 특이성에 대한 고찰)

  • Kim, Soo-Byeong;Lee, Na-Ra;Lee, Seung-Wook;Choi, Jun-Young;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.29 no.1
    • /
    • pp.71-81
    • /
    • 2012
  • Objectives : The purpose of this paper was to suggest new diagnostic method that was to supersede the estimation of electrical properties at acupoints. Thus, we developed the multi- frequencies bioelectrical impedance measurement system so as to analyze the state of bio-ions in body fluid as body compositions, not skin impedance at acupoint. Methods : At low frequency, the current does not penetrate the cell membrane and at high frequency, the current passes through both intracellular and extracellular fluid because of the decreas of cell membrane impedance. To confirm the reflection of composition in extracellular fluid or intracellular fluid of segment such as acupoint, the system was developed to detect the acupoint potential between adjacent two points in the area of LU3, LU4 and LU9 using 5,50 and 200KHz. Results : The detected acupoint potential has been decreased according to elevation of frequency. As a result of correlation of left/right identical acupoint, we observed a high correlation of three types of acupoint potential at multi-frequencies. Moreover, we observed the low correlation at 5KHz, and that was a significant factor to be considered as unbalanced relationship of identical acupoints. Conclusions : On the basis of meridian theoretical point of view, we may infer the acupoint's physiological composition using the multi-frequencies bioelectrical impedance measurement system.

Analysis on Upper Extremity of Hemiplegic Stroke Patients Using Bioelectrical Impedance (바이오 임피던스 분석을 이용한 뇌졸중 편마비환자의 상지 분석)

  • Yoo, Chan-Uk;Park, Ju-Hyung
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.94-101
    • /
    • 2017
  • This study is to compare and analyze the bioelectrical impedance values on the upper extremity (affected and non-affected side) in hemiplegic stroke patients. Experimental subjects were 24 stroke patients with hemiplegia undergoing stroke rehabilitation between October to November, 2015. Prediction marker, resistance, reactance, and phase angle were measured in the upper extremity (affected and non-affected side) of hemiplegic stroke patients, using MultiScan 5000, and then they were expressed as quantified values. The affected and non-affected side of upper extremity in stroke patients with hemiplegia exhibited significant differences in prediction marker, reactance, and phase angle (p<0.05). There were significant differences in the impedance values at the affected and non-affected side of hemiplegic stroke patients. Thus, the possibility of evaluating stroke patients undergoing clinical rehabilitation therapy was suggested.

Segmental Bioelectrical Impedance Analysis(SBIA) for Determining Body Composition (부위별 생체 전기 임피던스법을 이용한 체성분 분석에 관한 연구)

  • 차기철;손정민;김기진;최승훈
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.2
    • /
    • pp.179-186
    • /
    • 1997
  • A new bioelectrical impedance method has been developed and evaluated. The electrodes; were made of stainless steel and electrical interfaces were created by an upright subject gripping hand electrodes and stepping onto foot electrodes. Eight tactile electrodes were in contact with surfaces of both hands and feet; thumb, palm and fingers, front sole, and rear sole. Automatic on-off switches were used to change current pathways and to measure voltage differences for target segments. Segmental body resistances and whole body resistance(RWHOLE)were measured in 60 healthy subjects. Segmental resistances of right arm(RRA), left arm(RLA), trunk(RT), right leg(RRL) and left leg(RLL)were310.0$\pm$61.6$\Omega$, 316.9$\pm$64.6$\Omega$, 25.1$\pm$3.4$\Omega$, 236.8$\pm$31.2$\Omega$ and 237.6$\pm$30.4$\Omega$, respectively. Individual segmental impedance indexes(Ht2/RRA, Ht2/RT, and Ht2 /RLA) were closely related to lean body mass(LBM)as measured by densitometry ranged from r=0.925 to 0.960. Ht2/(RRA+RT+RLA) predicted LBM slightly better(r=0.969) than the traditional index, Ht2/RWHOLE(r=0.964), supporting the accuracy of the segmental measurement. A multiple regression equation utilizing Ht2/RRA, Ht2/RT and Ht2/RRL predicted LBM with r=0.971. Ht2/RRA term of the regression contributed to more than 40$\%$ of the LBM prediction, indicating that lean mass of arm represented whole body LBM more closely than other body segments. The new bioimpedance method was characterized by upright posture, eight tactile electrodes, segmental measurements and utilization of electronic switches in comparison with the traditional method. The measurement with this new method was extremely reproducible, quick and easy to use.

  • PDF