• 제목/요약/키워드: biodegradable scaffolds

검색결과 61건 처리시간 0.027초

Elution of amikacin and vancomycin from a calcium sulfate/chitosan bone scaffold

  • Doty, Heather A.;Courtney, Harry S.;Jennings, Jessica A.;Haggard, Warren O.;Bumgardner, Joel D.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제2권3호
    • /
    • pp.159-172
    • /
    • 2015
  • Treatment of polymicrobial infected musculoskeletal defects continues to be a challenge in orthopaedics. This research investigated single and dual-delivery of two antibiotics, vancomycin and amikacin, targeting different classes of microorganism from a biodegradable calcium sulfate-chitosan-nHA microsphere composite scaffold. The addition of chitosan-nHA was included to provide additional structure for cellular attachment and as a secondary drug-loading device. All scaffolds exhibited an initial burst of antibiotics, but groups containing chitosan reduced the burst for amikacin at 1hr by 50%, and vancomycin by 14-25% over the first 2 days. Extended elution was present in groups containing chitosan; amikacin was above MIC ($2-4{\mu}g/mL$, Pseudomonas aeruginosa) for 7-42 days and vancomycin was above MIC ($0.5-1{\mu}g/mL$ Staphylococcus aureus) for 42 days. The antibiotic activity of the eluates was tested against S. aureus and P. aeruginosa. The elution from the dual-loaded scaffold was most effective against S. aureus (bacteriostatic 34 days and bactericidal 27 days), compared to vancomycin-loaded scaffolds (bacteriostatic and bactericidal 14 days). The dual- and amikacin-loaded scaffolds were effective against P. aeruginosa, but eluates exhibited very short antibacterial properties; only 24 hours bacteriostatic and 1-5 hours bactericidal activity. For all groups, vancomycin recovery was near 100% whereas the amikacin recovery was 41%. In conclusion, in the presence of chitosan-nHA microspheres, the dual-antibiotic loaded scaffold was able to sustain an extended vancomycin elution longer than individually loaded scaffolds. The composite scaffold shows promise as a dual-drug delivery system for infected orthopaedic wounds and overcomes some deficits of other dual-delivery systems by extending the antibiotic release.

Characterizations of nano-zinc doped hydroxyapatite to use as bone tissue engineering

  • Abdel-Ghany, Basma E.;Abdel-Hady, Bothaina M.;El-Kady, Abeer M.;Beheiry, Hanan H.;Guirguis, Osiris W.
    • Advances in materials Research
    • /
    • 제4권4호
    • /
    • pp.193-205
    • /
    • 2015
  • Contamination by bacterial strands is a major problem after bone replacement surgeries, so there is a great need to develop low cost biocompatible antibacterial bioactive scaffolds to be used in bone tissue engineering. For this purpose, nano-zinc doped hydroxyapatite with different zinc-concentrations (5, 10 and 15 mol%) was successfully prepared by the wet chemical precipitation method. The prepared powders were used to form porous scaffolds containing biodegradable Ca-cross-linked alginate (5%) in order to enhance the properties of alginate scaffolds. The scaffolds were prepared using the freeze-gelation method. The prepared powders were tested by X-ray diffraction; transmission electron microscope and Fourier transform infrared analyses, while the prepared scaffolds were investigated by Fourier transform infrared analyses, thermogravimetric analyses and measurement of the antibacterial properties. Best results were obtained from scaffold containing 15% mol zinc-doped hydroxyapatite powders and 5% alginate concentration with ratio of 70:30.

마이크로 광 조형기술을 이용한 인공지지체의 제작을 위한 생분해성 수지의 개발 및 경화 특성 파악 (The development of biodegradable resin for scaffold fabrication using micro-stereolithography and curing characteristics analysis of the resin)

  • 이진우;조동우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.147-148
    • /
    • 2006
  • A research on scaffold fabrication has been progressed in many research groups. However, the mechanical properties of existing biodegradable materials are still not satisfactory. But, PPF (poly (propylene fumarate)) has a good mechanical property in comparison to other biodegradable materials. Nevertheless, the viscosity of the synthesized PPF is too high to fabricate structures using micro-stereolithography. Therefore, the viscosity of the resin was made low by adding the diethyl fumarate and this material could be used in micro-stereolithography apparatus. Then, a photoinitiator was added for photo crosslinking of the DEF/PPF resin. 2.5D and 3D scaffolds were fabricated our system and curing characteristics of the resin were analyzed through the experiment.

  • PDF

Myocardial tissue engineering using electrospun nanofiber composites

  • Kim, Pyung-Hwan;Cho, Je-Yoel
    • BMB Reports
    • /
    • 제49권1호
    • /
    • pp.26-36
    • /
    • 2016
  • Emerging trends for cardiac tissue engineering are focused on increasing the biocompatibility and tissue regeneration ability of artificial heart tissue by incorporating various cell sources and bioactive molecules. Although primary cardiomyocytes can be successfully implanted, clinical applications are restricted due to their low survival rates and poor proliferation. To develop successful cardiovascular tissue regeneration systems, new technologies must be introduced to improve myocardial regeneration. Electrospinning is a simple, versatile technique for fabricating nanofibers. Here, we discuss various biodegradable polymers (natural, synthetic, and combinatorial polymers) that can be used for fiber fabrication. We also describe a series of fiber modification methods that can increase cell survival, proliferation, and migration and provide supporting mechanical properties by mimicking micro-environment structures, such as the extracellular matrix (ECM). In addition, the applications and types of nanofiber-based scaffolds for myocardial regeneration are described. Finally, fusion research methods combined with stem cells and scaffolds to improve biocompatibility are discussed. [BMB Reports 2016; 49(1): 26-36]

Effect of polymer concentration in cryogelation of gelatin and poly (vinyl alcohol) scaffolds

  • Ceylan, Seda;Demir, Didem;Gul, Gulsah;Bolgen, Nimet
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 2019
  • The aim of this study was to investigate the effect of total polymer concentration on the chemical structure, morphology of pores, porosity, swelling ratio, degradation of gelatin-poly (vinyl alcohol) (Gel-PVA) cryogel scaffolds. Porous cryogels were prepared with cryogelation technique by using glutaraldehyde as a crosslinker. Functional group composition of cryogels after crosslinking was investigated by Fourier Transform Infrared (FTIR). The morphology of cryogels was characterized via scanning electron microscopy (SEM) and porosity analysis. All of the cryogels had a porous structure with an average pore size between $45.58{\pm}14.28$ and $50.14{\pm}4.26{\mu}m$. The cryogels were biodegradable and started to degrade in 14 days. As the polymer concentration increased the swelling ratio, the porosity and the degradation rate decreased. Spongy and mechanically stable Gel-PVA cryogels, with tunable properties, can be potential candidates as scaffolds for tissue engineering applications.

플라스마 처리와 아크릴산 결합에 의한 PLLA 필름 및 지지체의 최적 친수화와 연골세포 점착 (Optimal Hydrophilization and Chondrocyte Adhesion of PLLA Films and Scaffolds by Plasma Treatment and Acrylic Acid Grafting)

  • 양희석;박귀덕;안광덕;김병수;한동근
    • 폴리머
    • /
    • 제30권2호
    • /
    • pp.168-174
    • /
    • 2006
  • 기존의 고분자 지지체의 소수성 및 세포친화성을 향상시켜 조직공학용 고기능성 지지체로 사용하기 위해서 여러 가지 플라스마 처리와 카복실기를 함유한 아크릴산(AA)을 직접 chamber내에서 in situ 그래프트 결합을 행하여 최적의 친수성을 갖는 생분해성 poly(L-lactic acid) (PLLA) 필름 및 이중기공 지지체를 제조하였다. 표면분석 결과, 표면개질된 비다공성 PLLA 필름 및 이중기공 지지체 표면은 미처리 PLLA control에 비해서 접촉각의 감소와 카복실기 함량의 증가로 친수성이 크게 증가하였다. 특히 여러 가지 표면개질 방법 중 Ar(아르곤)/AA 시료나 Ar+TP(열중합) 시료보다는 Ar 플라스마와 AA를 차례로 처리한 Ar+AA+AA 시료가 다른 시료들보다 접촉각이 낮고 카복실기가 많아서 최적의 표면 친수화 처리조건임을 알 수 있었으며, 표면개질된 PLLA 필름 및 이중기공 지지체의 경우 친수성이 증가함에 따라서 연골세포의 점착과 증식도 크게 향상되었다.

쾌속조형시스템을 이용한 생체 조직 재생용 지지체 제작과 특성분석 (Bio-degradable 3D-scaffold fabrication using rapid-prototyping system)

  • 김지웅;박고은;이준희;박수아;김완두
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1697-1699
    • /
    • 2008
  • The purpose of tissue engineering is to repair or replace damaged tissues or organs by a combination of cells, scaffold, suitable biochemical and physio-chemical factors. Among the three components, the biodegradable scaffold plays an important role in cell attachment and migration. In this study, we designed 3D porous scaffold by Rapid Prototyping (RP) system and fabricated layer-by-layer 3D structure using Polycarprolactone (PCL) - one of the most flexible biodegradable polymer. Furthermore, the physical and mechanical properties of the scaffolds were evaluated by changing the pore size and the strand diameter of the scaffold. We changed nozzle diameter (strand diameter) and strand to strand distance (pore size) to find the effect on the mechanical property of the scaffold. And the surface morphology, inner structure and storage modulus of PCL scaffold were analyzed with SEM, Micro-CT and DMA.

  • PDF

A study on the evaluation of artificial cartilage using synthetic biodegradable polymers

  • Oh, Ho-Jung;Lee, Nam-Kyung;Kim, Soon-Nam;Hong, Choong-Man;Lee, Ki-Hong;Yoo, Si-Hyung;Shin, In-Soo;Lim, Jae-Hyun;Choi, Seung-Eun
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.100.1-100.1
    • /
    • 2003
  • Tissue engineering has arisen to address the extreme shortage of tissues and organs for transplantation and repair. One of the most successful techniques has been the seeding and culturing cells on three-dimensional biodegradable scaffolds in vitro followed by implantaion in vivo. We used PLA and PLGA as biodegradable polymers and rabbit chondrocytes were isolated and applied to PLA and PLGA to make artificial cartilage. To evaluate the biocompatibility and biological safety of polymers, in vitro cytotoxicity and in vivo animal tests were investigated. (omitted)

  • PDF