• Title/Summary/Keyword: bio-signals

Search Result 349, Processing Time 0.026 seconds

Design and Implementation of Mobiel Terminal with Multi Bio-signal Measurement for u-Healthcare System (u-헬스케어 시스템에서 멀티 생체신호 측정 무선 단말기 설계 및 구현)

  • Jang, M.S.;Eom, S.H.;Kim, P.S.;Lee, E.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.27-34
    • /
    • 2013
  • Most of existing biomedical signal measurement devices measure and evaluate biomedical signal only in a single device. Also, even if the device is multi-functional, those biomedical signals can be measured by selection of the user. In this paper, we implemented wristband-style biomedical signal measurement device for u-healthcare system to solve the problem above. Implemented device uses 4 infrared sensors to measure the pulse, 2 electrodes to measure the skin conductivity, and 3-axis accelerometer to measure momentum. Also, we propose a communication packet frame for transmitting biomedical signal data to PC or mobile device, using Zigbee. Studies show that our device has the error rate of less than twice for pulse measurement, 85.6%, 84.7% reliability for momentum measurement, and the skin conductivity has changed according to the user's physical status.

  • PDF

Implementation of Motion Analysis System based on Inertial Measurement Units for Rehabilitation Purposes (재활훈련을 위한 관성센서 기반 동작 분석 시스템 구현)

  • Kang, S.I.;Cho, J.S.;Lim, D.H.;Lee, J.S.;Kim, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2013
  • In this paper, we present an inertial sensor-based motion capturing system to measure and analyze whole body movements. This system implements a wireless AHRS(attitude heading reference system) we developed using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient's body provide the quaternions representing the patient segments's orientation in space. We performed 3D motion capture using the quaternion data calculated. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE of 2.56 degree. The results suggest that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limbs or gait analysis during the post-stroke recovery process.

  • PDF

Design of Two-Step Open System for Personalized Health Data Access (개인화된 건강 데이터 처리를 위한 2-Step 개방형 시스템의 설계)

  • Jeon, Young-Jun;Hwang, Hee-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.177-183
    • /
    • 2015
  • The purpose of ICT Healing platform is the prevention of chronic disease. It is intended to early warning of the disease through the information such as the bio-signals and lifestyle. In this paper, we provide a 2-Step open system(TOS) for personalized health data access. TOS is connected between the personal health related data providers and service providers of individuals ICT Healing platform, a software engine for relaying personalized health data. The proposed system, to operate in isolation to 2 step in personal health document repository Inbound module and Outbound module to provide an inquiry service to external organizations. Therefore, we propose a personalized editable Manifest concept for defining data exchange between Step. This can be used as a reference model to collect the personal health information is scattered in many health related service institutions (Hospitals, Fitness Centers, Health Examination Centers, Personal Health Device, etc.) and under private-led liberalization.

Characterization of Organic Solvent Stable Lipase from Pseudomonas sp. BCNU 106 (Pseudomonas sp. BCNU 106이 생산하는 유기용매 내성 리파아제의 특성)

  • Choi, Hye Jung;Hwang, Min Jung;Kim, Dong Wan;Joo, Woo Hong
    • Journal of Life Science
    • /
    • v.26 no.5
    • /
    • pp.603-607
    • /
    • 2016
  • A crude extracellular lipase from solvent-tolerant bacterium Pseudomonas sp. BCNU 106 was highly stable in the broad pH range of 4-10 and at temperature of 37℃. Crude lipase of BCNU 106 exhibited enhanced stability in 25% organic solvents such as xylene (121.85%), hexane (120.35%), octane (120.41 %), toluene (118.14%), chloroform (103.66%) and dodecane (102.94%) and showed excellent stability comparable with the commercial immobilized enzyme. In addition, the stability of BCNU 106 lipase retained above 110% of its enzyme activity in the presence of Cu2+, Hg2+, Zn2+ and Mn2+, whereas Fe2+ strongly inhibited its stability. The detergents including tween 80, triton X-100 and SDS were positive signals for lipase stability. Because of its stability in multiple organic solvents, cations and surfactants, the Pseudomonas sp. BCNU 106 lipase could be considered as a potential biocatalyst in the industrial chemical processes without using immobilization.

Remote medical Smart healthcare system for IoT-based multi-biometric information measurement (IoT기반 다중 생체정보 측정을 위한 원격 의료 스마트 헬스케어 시스템)

  • Sim, Joung-Yong;Seo, Hyun-Gon
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.53-61
    • /
    • 2020
  • Recently, as the uncontact service is activated in earnest due to the Corona 19 virus, the necessity of system development to provide non-face-to-face contact remote medical service has increased. In this study, we propose a smart healthcare system, Rm_She(Remote Medical Smart Healthcare System). Rm_She can collect and manage various vital signs information by connecting various healthcare products that detect bio-signals based on IoT to one application. The health check app (HC_app) is used to connect vital sign measurement devices to a wireless LAN and receive vital sign values from the HC_app. Then, the vital signs are output to the user on the smartphone, and the corresponding information is transmitted to the healthcare management server. The healthcare server receives the measured values and stores them in a database, and the stored measured values are provided as a web service so that medical staff can remotely monitor them in real time.

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.

Analysis and comparison of textile electrode's electrical characteristics in several shapes for biopotential signals (생체 신호 측정을 위한 섬유전극의 형태에 따른 전기적 특성 분석 및 비교)

  • Lee, Young-Jae;Lee, Kang-Hwi;Lee, Jeong-Whan;Kang, Da-Hye;Cho, Ha-Kyung;Cho, Hyun-Seung;Lee, Joo-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.371-372
    • /
    • 2008
  • Many kinds of electrodes have been developed in various forms and shapes for measurement of bio potential signal. Textile electrode has benefit of collect long tenn data monitoring because of it is non-consciousness, convenient and do not occur skin irritation. However, It is very difficult to acquire available data due to high impedance of electrode and unstable skin-electrode contact which generate motion artifact. Also snap button which usually used as mediator between textile and measurement device cause change of electrical characteristics. In this paper, we inflated textile electrode to stabilize contact and add conductive silver paste between textile and snap button to improve conductance. To compare the performance of two methods, flat or inflated and add conductive paste or not, four types of electrodes are tested on each impedance and SNR by ECG measurement. In result, the first type electrode which flat and non-conductive paste showed the worst performance and the last type electrode which is inflated shape and contain conductive paste show the best performance.

  • PDF

Study for Chronic Diseases Patients Management System using Zigbee of based WPAN (WPAN 기반의 Zigbee를 이용한 만성질환 환자 관리 시스템에 관한 연구)

  • Park, Hung-Bog;Seo, Jung-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.965-972
    • /
    • 2011
  • As an aged population has increased in Korea, the number of patients with chronic disease has soared up as well. The rapid increase of the chronic disease triggers a need of new paradigm of healthcare. In terms of data transmission of healthcare system, a use of data-transmission protocol based on bluetooth could be dismal in application of healthcare due to its postponement of connection. On the contrary, WPAN is evaluated to be proper to support the application of healthcare in restricted geographic areas. In addition, the bluetooth, a base of the current wireless network, doesn't support a special mechanism to cope up with emergent patients because of its delayed connection among devices. Against this backdrop, this study aims to design an integrated interface of multi bio-sensing and suggest a measuring and monitering system for the patients with chronic illnesses by using Zigbee of WPAN as a sufficient bandwidth is anticipated owing to frequent deliveries of complicated biological signals.

Removing the Motion Artifacts in the Pulse Signal Detected from the PFS Using the Quasi-periodicity (유사 주기성을 이용한 PFS 펄스 신호의 동잡음 제거)

  • Lee, Han-Wook;Chun, Joong-Chang;Jeong, Won-Geun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.591-598
    • /
    • 2016
  • For the mobile healthcare environment, it is important to measure the exact biomedical signals in real time, and another key point is to design mobile healthcare devices with low power consumption. In this paper, we propose a method in which the piezo film sensor(PFS), having a low power characteristic, is used to measure the pulse signal synchronized with the heart rate from the radial artery. The critical issue in the bio-signal processing is the existence of the motion artifacts. To dissolve this problem, we have applied the periodic moving average filter using the quasi-periodicity of the pulse signal in addition to the conventional method of the adaptive filtering using the reference signal. Results of simulation and experiments are presented to confirm that the quasi-periodicity of the PFS signal can be used to eliminate completely the motion artifacts which still appears after the adaptive filtering.

Event Transmission of Respiratory rate and Heart rate Measured on Wheelchair (휠체어에서 호흡수와 심박수 측정 및 이벤트 전송)

  • Han, Dong-Kyoon;Kim, Jong-Myoung;Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.443-450
    • /
    • 2008
  • The purpose of this study is to measure both ECG and BCG(Ballistocariograph) signal of a subject on moving or resting wheelchair and detect the heart rate and respiratory rate and transmit an event message to remote server on emergent situation. To acquire ECG and BCG data, amplifier circuits were composed to be suitable for their characteristics. The output signals were converted to digital data and stored in bio-signal archiving media(SD card). CDMA module was used to transmit the event data on ECG electrode detachment and the received data was monitored by the developed C# application program. 5 volunteers participated in the experiment to evaluate the validity of the developed device. When the event occurs in each subject, 48 Kbyte data, stored for 32 seconds from that point, was transmitted to remote server through CDMA cellular phone network correctly. The received data of ECG, BCG, and 3-axial acceleration could be archived in server and the heart rate and respiratory rate could be measured and analyzed. The developed device in this study could acquire the ECG and BCG data of subjects on wheelchair simultaneously and measure their heart rate and respiratory rate. In addition, event data was verified to be transmitted to remote server without any errors.