• 제목/요약/키워드: bio-electric response

검색결과 14건 처리시간 0.024초

전기물고기의 방해 회피 반응 모델링과 응용 (Modeling Jamming Avoidance Response of Pulse-type Weakly Electric Fish)

  • 소재현;김대은
    • 제어로봇시스템학회논문지
    • /
    • 제21권10호
    • /
    • pp.924-929
    • /
    • 2015
  • In this paper, we suggest a phase difference algorithm inspired by weakly electric fish. Weakly electric fish is a fish which generates electric field though its electric organ in the tail. The weakly electric fish search for prey and detect an object by using electrolocation. The weakly electric fish have Jamming Avoidance Response (JAR) to avoid jamming signal. One of pulse-type weakly electric fish Gymnotus carapo also have JAR to reduce the probability of coincidence of pulses. We analyze this response signal and design the phase difference algorithm. We expect that simple algorithm inspired by weakly electric fish can be used in many engineering fields.

Electrorheology of HMDA Coupled Chitosan Succinate Suspension as an Anhydrous ER Fluid

  • Kong, Seong-Wook;Kim, Seung-Wook;Lee, Sang-Soon;Choi, Ung-Su
    • KSTLE International Journal
    • /
    • 제9권1_2호
    • /
    • pp.7-9
    • /
    • 2008
  • The electrorheology of the HMDA coupled chitosan succinate suspension in silicone oil was investigated. HMDA coupled chitosan succinate suspension showed a typical ER response upon application of an electric field. The shear stress for the HMDA coupled chitosan succinate suspension exhibited an electric field power of 2.0. The experimental results for the HMDA coupled chitosan succinate suspension was found to be an anhydrous ER fluid.

생체전위 분석에 의한 침구치료 효과 규명에 관한 연구 (A Study on Verification of Acupuncture Therapy Effect by Bio-potential Analysis)

  • 이용흠;박창규
    • 한국정보통신학회논문지
    • /
    • 제8권3호
    • /
    • pp.670-678
    • /
    • 2004
  • 한의학에서 경락은 생체에너지의 전달 통로이며, 진단치료의 기본대상이다. 그러나 서양의학에서는 경락을 신경-면역계통의 활동통로로 간주하고 있다. 침구치료 효과를 단순한 자극에 의한 인체의 반응으로 간주하고 있다. 본 논문에서는 시술자의 생체에너지가 전달될 때와 전달되지 않을 때, 즉 절연자침과 비절연자침을 시행하였을 경우, 경락과 비경락에서의 전위를 측정하였다. 그 결과 비절연자침 시행시에는 각 시술에 대한 반응이 뚜렷하게 나타나고 있으나 절연자침 시행시에는 첫 번째 자침 시술에만 반응하였다. 이는 침구치료의 효과가 단순한 침자극에 의한 효과라기 보다는 시술자의 생체에너지 전달과 더 밀접한 관계가 있음을 의미한다. 따라서, 침 자극에 의한 생체에너지 전달에 의한 인체의 반응을 전위의 변화로 분석하여 침구치료효과를 규명하였다.

생체에너지(기) 전달에 의한 경락 반응 분석 (Analysis of meridian response by bio-energy transmission)

  • 정석준;이용흠;정동명
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.141-144
    • /
    • 2002
  • Acupuncture effect principle on meridians is what physical stimulation does on general physiology so that it gets into new equilibrium from the fallen function state of human body. However, it is generally accepted that western medicine has regarded the action passageway of various kinds stimulation as nerve fluids tissue or nerve-endocrine-immune system. These regard any action for all meridians as a response to the stimulation. These are not treatments for transmission of the energy. This paper compares the change of electric potential when operator's bio-energy is passed on and when is not. As a result of it, the effect of acupuncture is different when a operator's bio-energy is passed on to meridians and it isn't. Therefore, it means that the general acupuncture is more effective than the insulation one. Moreover, we could certify that there is close relation between an operator's energy transmission and acupuncture effect.

  • PDF

레이저자극과 수기자극에 대한 경락전기반응 특성비교 (Comparison of meridians electric response property for laser and acupuncture stimulation)

  • 이용흠;류연항;정병조;신태민
    • 한국정보통신학회논문지
    • /
    • 제11권12호
    • /
    • pp.2335-2342
    • /
    • 2007
  • 최근에 레이저를 임상치료에 응용하는 사례가 증가하고 있다. 그러나 전기적 관점에서 레이저 자극이 경락에서 어떠한 전기적 반응을 유도할 수 있는지에 대한 연구가 미흡하고, 명확한 치료효과에 대한 임상보고가 발표되지 않고 있다. 본 논문에서는 레이저자극과 수기자극이 경락전위 형성에 미치는 영향을 비교 관찰하여 전기적 관점에서 침술과정 및 침술효과에 대한 객관적 근거를 제시하고자 하였다. 수양명대장경상의 삼간혈(LI3)을 각각 자극했을 경우, 삼간혈(LI3)과 합곡혈(LI4)에서의 전위변화를 측정하였다. 그 결과, 레이저 자극 시, 평균 피크전위는 $7.53{\pm}3.44{\mu}V$로 매우 낮게 나타났고, 자극전후 전위패턴에 차이가 없어서 레이저 자극에 대한 유효한 전기반응으로 간주하기 어렵다. 접지조건에 대한 수기자극에서는 평균피크전위가 $2.65{\pm}1.53mV$로 매우 높게 측정되었고, 개인별, 접지조건에 따라 전위크기와 패턴이 다양하게 나타나고 전위패턴은 주로 캐패시터의 충방전 전위와 매우 비슷하게 나타났다. 또한, 절연자침의 경우에서는 접지조건에 관계없이 평균 피크 전위가 $0.25{\pm}0.16mV$로 수기자극 전위에 비하여 매우 낮게 나타났으며, 이는 침자극에 대한 유효한 전기 반응으로 간주하기 어렵다. 따라서, 전기적 관점에서 침술과정과 침술효과는 시술자와 피시술자간의 생체이온전하의 이동에 의한 에너지 교감현상임을 확인하고, 수기자극은 경락의 전기반응을 유도하는 반면, 레이저 자극은 경락의 전기적 반응을 유도하기 어렵다는 것을 확인하였다.

생체-전기적 반응에 의한 한의학적 진단시스템의 설계 (Design of Oriental Medicine diagnosis system by Bio-Electric Response)

  • 이용흠;장근중;박창규
    • 한국정보통신학회논문지
    • /
    • 제8권2호
    • /
    • pp.420-429
    • /
    • 2004
  • 인체 생리의 부조화에 의한 기능적 이상 진단이 가시화 장비나 임상병리 소견으로도 진단할 수 없는 경우가 있기 때문에, 현대과학과 의공학의 특성을 접목한 EFG(Electro Functio Gram:기능전도) 측정 개념의 진단기술 개발이 요구되고 있다. 따라서 이러한 기능적 진단기술을 이용하여 양ㆍ한방 모든 분야에서 기초 진단기로 사용할 수 있는 재현성과 신뢰성, 편리성을 갖춘 범용의 진단시스템으로 개발하였다. 또한, 한의학적진단 및 치료를 위한 기와 혈의 인체 순환을 진단할 수 있는 사지 8CH(양,음경락), 두부 2CH 동시계측 방법 및 일괄 부착식 전극을 개발하였다. 성인 남자 20명(정상인)을 대상으로 한 임상데이터 분석결과, 인체의 12경락의 상태 및 자율신경계통의 상태를 진단할 수 있어서, 진단장비로써의 유의성을 확인하였다. 따라서, 본 논문에서는 인체 12부위의 음경락 양경락을 측정할 수 있는 H/W 및 S/W을 구현하고, EFG 체계를 구축하여 생체-전기적 반응에 의한 한의학적 진단 시스템을 설계하였다.

침구경략전위 측정에 의한 침 자극 반응 특성 (Response Properties of Acupuncture Stimulation by Meridian Electrical Potential Measurement)

  • 류연항;정병조;이용흠
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권5호
    • /
    • pp.408-413
    • /
    • 2008
  • Human body has a complete left and right symmetry structure, and the left and right balance by Yin and Yang. When the balance is broken, the left and right Meridian becomes abnormal condition. Acupuncture is a kind of therapy to recover from energy unbalance of the left and right Meridian to a new balance condition. In the study, we observed the electric potential along the stomach meridian (ST) in order to verify the energy consensus phenomenon by transportation of bio-energy between operator and subject during acupuncture. The acupuncture effects on opposite meridian site were investigated by comparing the electric potentials between the right and left ST sites. Meridian electrical potentials (MEPs) between operator and subject were simultaneously generated during the acupuncture and the polarity of MEPs was opposite. The results might imply the bio-energy transportation between operator and subject. In addition, we observed three different patterns of MEPs on both ST sites which might represent the condition of the related meridians because meridians in the body are organically interconnected.

키토산/폴리디아릴디메틸암모늄클로라이드 전기감응성 고분바 하이드로겔의 굽힘 거동에서 물 상태에 따른 영향 분석 (Effect of Water State in Electroactive Chitosan/Poly (Diallyldimethylammonium Chloride) Hydrogels on Bending Behavior at Various pH Conditions)

  • 윤성길;김선정;김인영;김선일
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권3호
    • /
    • pp.344-347
    • /
    • 2007
  • A interpenetrating polymer network (IPN) hydrogel, composed of chitosan (CS) and poly(diallydimethylammonium chloride) (PDADMAC) was prepared, which exhibited electrical sensitive behavior. The swelling behavior of the CS/PDADMAC SIPN hydrogel was studied by immersion of the gel into various pH buffer solutions, and their stimuli response in electric fields also investigated. In order to clarify the relationship between the equilibrium swelling ratio and bending behavior of the SIPN hydrogels, the state of water in the SIPN hydrogel was also investigated using differential scanning calorimetry (DSC).

Electrochemical Response of Polymer Actuators using Finite Element Formulation and ANSYS/Emag

  • Kang, Sung-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.369-375
    • /
    • 2010
  • The two-dimensional finite element formulation for the basic field equations governing electrochemical responses of ionic conducting polymer-metal composite(IPMC) actuators is proposed in the present study. Biaxial deformation of a platinum plated Nafion actuator having 4 electrodes is dominated by electro-osmosis of hydrated ions and self-diffusion of free water molecules. Some numerical studies for IPMC actuators with electric field are carried out in order to show the validity of the proposed formulation and electric field analysis for the initial condition of total charge distribution are conducted using commercial code ANSYS/Emag.

바이오디젤 원료용 유채 함수율 센서 개발 (Development of a Moisture Content Sensor for Rapeseed as Biodiesel Raw Material)

  • 이충근;최용;전현종;정광식
    • Journal of Biosystems Engineering
    • /
    • 제34권1호
    • /
    • pp.15-20
    • /
    • 2009
  • This study was conducted to develop a moisture sensor for rapeseed, a bio-diesel material. A typical rapeseed, SUNMANG, was used as a raw material. The rapeseed moisture content sensor consists of three components, such as upper and bottom electrodes, a test material dish, and a fixing housing. To evaluate the performance, a data acquisition system was equipped with the rapeseed moisture sensor, computer, printer, and main board. The findings of this study were: 1) the rapeseed moisture content was inversely proportional to electric resistance, and 2) values of electric resistance were recorded in a range of $10{\sim}100\;M{\Omega}$, depending upon a change of the moisture content. The determination of coefficient ($R^2$) and standard error between rapeseed moisture content and electric resistance were 0.9921 and ${\pm}0.289$, which indicated a highly correlative relationship. The response of rapeseed moisture sensor to temperature change was also observed for further performance test. Satisfying results were obtained, such as the determination of coefficient ($R^2$) of 0.9918, predicted standard error of ${\pm}0.373%$, deviation of 0.103%, measurement error of $0.14{\sim}0.48%$, standard deviation of $0.01{\sim}0.22%$, and measurement time of 28.3 s per point, respectively.