• Title/Summary/Keyword: bio-beating

Search Result 5, Processing Time 0.209 seconds

Kraft Pulping Characteristics by Bio-pretreatment with White-rot Fungus (백색부후균 생물 전처리에 의한 Kraft Pulp화 특성)

  • Kang, Kyu-Young;Jo, Byoung-Muk;Oh, Jung-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.103-110
    • /
    • 2001
  • Bio-kraft pulping of Populus alba${\times}$glandulosa pretreated with white-rot fungus, Phanerochaete chrysosporium KCCM 34740, was investigated The biopulping efficiency was evalued based on fungal pretreatment time and properties of bio-kraft pulp (pulp yield, freeness, WRY, kappa number and brightness) in comparison to the controls. Pretreatment of poplar wood chips with Phanerochaete chrysosporium KCCM 34740 for 10days resulted in a some increase in screened yield (by 2%). According to increase of fungal incubation time, decrease in freeness (CSF) and increase in WRY were observed And bio-kraft pulping also led to improvement of physical properties of handsheet. As a result of bio-beating effect, we expect the saving of chemicals in kraft cooking process and energy consumption in beating process.

  • PDF

Ruvbl1 is Essential for Ciliary Beating during Xenopus laevis Embryogenesis

  • Chan Young Kim;Hyun-Kyung Lee;Hongchan Lee;Hyun-Shik Lee
    • Development and Reproduction
    • /
    • v.27 no.3
    • /
    • pp.159-165
    • /
    • 2023
  • The Ruvb-like AAA ATPase1 (Ruvbl1; also known as Pontin) is an evolutionary conserved protein belonging to the adenosine triphosphates associated with diverse cellular activities (AAA+) superfamily of ATPases. Ruvbl1 is a component of various protein supercomplexes and is involved in a variety of cellular activities, including chromatin remodeling, DNA damage repair, and mitotic spindle assembly however, the developmental significance of this protein is unknown and needs detailed investigation. We investigated the developmental significance of Ruvbl1 in multiciliated cells of the Xenopus laevis epidermis since ruvbl1 is expressed in the multiciliated cells and pronephros during X. laevis embryogenesis. The knockdown of ruvbl1 significantly impaired cilia-driven fluid flow and basal body polarity in the X. laevis epidermis compared to control embryos, but did not affect cilia morphology. Our results suggest that Ruvbl1 plays a significant role in embryonic development by regulating ciliary beating; however, further investigation is needed to determine the mechanisms involved.

Evaluation of Methods for Cyanobacterial Cell Lysis and Toxin (Microcystin-LR) Extraction Using Chromatographic and Mass Spectrometric Analyses

  • Kim, In S.;Nguyen, Giang-Huong;Kim, Sung-Youn;Lee, Jin-Wook;Yu, Hye-Weon
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.250-254
    • /
    • 2009
  • Contamination of microcystins, a family of heptapeptide hepatotoxins, in eutrophic water bodies is a worldwide problem. Due to their poisoning effects on animals and humans, there is a requirement to characterize and quantify all microcystins present in a sample. As microcystins are, for most part, intracellular toxins produced by some genera of cyanobacteria, lysing cyanobacterial cells to release all microcystins is considered an important step. To date, although many cell lysis methods have been used, little work has been conducted comparing the results of those different methods. In this study, various methods for cell lysis and toxin extraction from the cell lysates were investigated, including sonication, bead beating, freeze/thaw, lyophilization and lysing with TritonX-100 surfactant. It was found that lyophilization, followed by extraction with 75% methanol, was the most effective for extracting toxins from Microcystis aeruginosa cells. Another important step prior to the analysis is removing impurities and concentrating the target analyte. For these purposes, a C18 Sep-Pak solid phase extraction cartridge was used, with the percentage of the eluent methanol also evaluated. As a result, methanol percentages higher than 75% appeared to be the best eluting solvent in terms of microcystin-leucine-arginine (MC-LR) recovery efficiency for the further chromatographic and mass spectrometric analyses.

A Computational Model of the Temperature-dependent Changes in Firing Patterns in Aplysia Neurons

  • Hyun, Nam-Gyu;Hyun, Kwang-Ho;Hyun, Kwang-Beom;Han, Jin-Hee;Lee, Kyung-Min;Kaang, Bong-Kiun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.15 no.6
    • /
    • pp.371-382
    • /
    • 2011
  • We performed experiments using Aplysia neurons to identify the mechanism underlying the changes in the firing patterns in response to temperature changes. When the temperature was gradually increased from $11^{\circ}C$ to $31^{\circ}C$ the firing patterns changed sequentially from the silent state to beating, doublets, beating-chaos, bursting-chaos, square-wave bursting, and bursting-oscillation patterns. When the temperature was decreased over the same temperature range, these sequential changes in the firing patterns reappeared in reverse order. To simulate this entire range of spiking patterns we modified nonlinear differential equations that Chay and Lee made using temperature-dependent scaling factors. To refine the equations, we also analyzed the spike pattern changes in the presence of potassium channel blockers. Based on the solutions of these equations and potassium channel blocker experiments, we found that, as temperature increases, the maximum value of the potassium channel relaxation time constant, ${\tau}_n(t)$ increases, but the maximum value of the probabilities of openings for activation of the potassium channels, n(t) decreases. Accordingly, the voltage-dependent potassium current is likely to play a leading role in the temperature-dependent changes in the firing patterns in Aplysia neurons.

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.