• Title/Summary/Keyword: bilateral ratio

Search Result 204, Processing Time 0.026 seconds

Soft tissue changes in skeletal class II patients treated with bilateral sagittal split osteotomy advancement surgery (골격성 II 급 부정교합 환자의 하악골 전진술 후 연조직 변화 분석)

  • Shin, Hee-Jin;Kim, Jin-Wook;Park, Je-Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.2
    • /
    • pp.94-99
    • /
    • 2010
  • The purpose of this study was to examine the soft tissue changes in skeletal class II patients after mandibular advancement by bilateral sagittal split ramus osteotomy (BSSRO). In Asian population, the incidence of skeletal class II malocclusion is lower than that of skeletal class III malocclusion unlike the caucasians. This study was conducted to figure out the ratio at which hard tissue and soft tissue changes after mandibular advancement by analyzing cephalograms of 13 patients that have undergone the mandibular advancement surgery. As a result, change ratios of Li, B', Pog' according to the movement of li, B, Pog were found to be 0.59, 1.06, 0.82. Also, vertical height of vermilion zone (Si-Vb) and lower lip and chin (Si-Me') were measured to evaluate vertical changes. Vermilion zone showed tendency to decrease by 1.02 mm on the average postoperatively, whereas vertical length of lower lip and chin showed tendency to increase by 3.57 mm on the average.

A Study on Statistics Discrepancies in the Bilateral Trade Between Korea and Its Major Partners - Focusing on PRC and Hong Kong - (한국과 주요 교역국 간 무역통계 불일치에 관한 연구 - 중국과 홍콩을 중심으로 -)

  • Seung-Kwan Shin
    • Korea Trade Review
    • /
    • v.47 no.2
    • /
    • pp.31-46
    • /
    • 2022
  • The purpose of this study is to measure the degree of discrepancies in the bilateral trade data between South Korea and its five major trade partners and to identify the key factors causing the discrepancies. By analyzing statistics based on the CIF/FOB ratio estimation and taking into consideration the trade flow via Hong Kong, the study finds that the discrepancies in South Korea's trade data with the US, Vietnam, and Japan are insignificant. In case of Hong Kong, however, the value of South Korea's import from Hong Kong is extensively inconsistent with Hong Kong's export to South Korea(i.e. the mirror data) while the value of South Korea's export to Hong Kong generally corresponds to its mirror data. Such discrepancies are caused by differences in recording re-exports, which are often found in the trade flow via entrepôt economics including Hong Kong. Meanwhile, discrepancies in reported bilateral trade flows between South Korea and People's Republic of China(PRC) remain relatively marginal. The discrepancy of statistics between South Korea as the exporter and PRC as the importer is mainly caused by the trade flow via Hong Kong. On the other hand, the discrepancy of statistics between South Korea as the importer and PRC as the exporter is assumably due to the differences in attribution of trade partners.

A RADIOGRAPHIC STUDY OF THE HYOID BONE POSITION IN MALOCCLUSION (설골위치에 관한 연구)

  • Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.17 no.1
    • /
    • pp.7-13
    • /
    • 1987
  • This study was conducted to clarify the relationship of hyoid bone position to tongue position and mandible when malocclusion is categorized in the bilateral and in the vertical components. Five groups of samples (normal occlusion, unilateral and bilateral cross-bite, openbite, deep-bite) were selected for his investigation by utilizing the cephalograms. On the basis study, the following conclusions were obtained; 1. In the normal group. the mean hyoid position (H-M) was $9.83{\pm}4.27mm$. The mean distance of hyoid body to tongue dorsum (H-T) was $52.17{\pm}6.70mm$. The ratio of H-M/H-T was $18.59\%$. 2. In all malocclusion groups, the hyoid position (H-M) was found to be larger than that of the norm except the deep overbite group 3. The tongue dorsum position (H-T) was increased, compared to that of norm, in all malocclusion groups. 4. Hyoid position (H-M) was found to show high correlation to the ratio of H-M/H-T, H-T, PI-T (0.890, 0.699, 0.455). 5. The hyoid position (H-M) was found to show low correlation to the measurements of mandible, but among them the ODI was found to show conversely a little higher correlation against hyoid position (H-M).

  • PDF

Hypericum Perforatum Decreased Hippocampus TNF-${\alpha}$ and Corticosterone Levels with No Effect on Kynurenine/Tryptophan Ratio in Bilateral Ovariectomized Rats

  • El-Bakly, Wesam M.;Hasanin, Amany H.
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.18 no.3
    • /
    • pp.233-239
    • /
    • 2014
  • The present study was designed to investigate the effect Hypericum Perforatum (HP), on behavioral changes, corticosterone, TNF-${\alpha}$ levels and tryptophan metabolism and disposition in bilateral ovariectomized rats compared to $17{\alpha}$-ethinylestradiol. Behavioral analysis by measuring immobility time in forced swimming test and open field test, serum and hippocampal corticosterone and TNF-${\alpha}$ along with hippocampal kynurenine/tryptophan ratio were determined in mature ovariectomized rats treated orally either by HP at three different doses 125, 250, and 500 mg/kg/day or by $17{\alpha}$-ethinylestradiol $30{\mu}g/kg/day$ for 30 days. Ovariectomized rats showed significant increase in immobility time in the forced swimming test. Along with elevation in serum and hippocampal TNF-${\alpha}$ and corticosterone levels associated with significant increase in hippocampal kynurenine/tryptophan ratio. Immobility time in the forced swimming test was decreased in rats treated by different doses of HP in a dose dependent manner and $17{\alpha}$-ethinylestradiol with no concomitant changes in the open field test. Only Rats treated with HP exhibited significant decrease in the elevated serum and hippocampal TNF-${\alpha}$ and corticosterone, which couldn't explain the associated insignificant effect on hippocampaus kynurenine/tryptophan ratio in comparison to ovariectomized untreated rats. It is concluded that increased tryptophan metabolism toward kynurenine secondary to elevated corticosterone and TNF-${\alpha}$ might be one of the pathohphysiological mechanisms that could explain depression like state observed in this rat model. Further, the observed attenuating effect of HP on TNF-${\alpha}$ and corticosterone could contribute in its antidepressant effect in this animal model by other ways than their effects on tryptophan-kynurenine metabolism pathway.

Minimally Invasive Treatment for Sacroiliac Dislocation in Dogs

  • Kim, Young-ung;Cho, Hyoung-sun;Kim, Sun-young;Lee, Ki-chang;Kim, Nam-soo;Kim, Min-su
    • Journal of Veterinary Clinics
    • /
    • v.34 no.5
    • /
    • pp.370-373
    • /
    • 2017
  • Sacroiliac dislocation is the separation of the iliac wing from the pelvic bone and needs to be repaired by surgery. Corrective surgical methods include open reduction and minimally invasive techniques. In the present study, we used a minimally invasive surgical technique in seven dogs with sacroiliac dislocation. Five cases had unilateral sacroiliac joint luxation and two cases had bilateral sacroiliac joint luxation; all were referred to hospital after being hit by an automobile. All cases were treated with a fluoroscope-assisted, minimally invasive technique. Patients were evaluated by measuring surgery time, postoperative ambulatory time, and calculating pelvic canal diameter ratios. Surgery time was measured from initial incision to completion of skin closure. Mean surgery time was 30.6 minutes in unilateral sacroiliac joint luxation and 68 minutes in bilateral sacroiliac joint luxation. Mean preoperative pelvic canal diameter ratio was 1.22 (${\pm}0.27$), immediate postoperative pelvic canal diameter ratio was 1.26 (${\pm}0.10$), and at 2 weeks after surgery, the pelvic canal diameter ratio was 1.37 (${\pm}0.22$). All cases were ambulatory within 1 week and mean postoperative ambulatory time was 5 days. Based on the results, the use of a minimally invasive technique for correction of sacroiliac dislocation can decrease surgical time, lessen operative and postoperative burdens on patients, and provide owners with a good prognosis.

Evaluation of entrance surface dose and image quality according to the installation of Bismuth shield in the case of endovascular treatment of cerebral aneurysm (뇌동맥류 코일 색전술 시 Bismuth 차폐체 설치에 따른 입사 표면 선량 평가 및 화질 평가)

  • Kim, Jae-Seok;Kim, Young-Kil;Choi, Jae-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.7
    • /
    • pp.779-785
    • /
    • 2019
  • By applying an ergonomically developed Bismuth shield to the endovascular treatment of cerebral aneurysm the radiation dose of the scalp and lens from the medical radiation exposure was reduced. The enrtance surface dose was analyzed by measuring the occipital parts, bilateral temporal parts, bilateral quadriceps, and nasal tip of the developed bismuth shield using a photostimulable fluorescence dosimeter before (Group A) before use (Group B). Signal to noise ratio (SNR) and contrast to noise ratio (CNR) analysis were used to evaluate the image quality when Bismuth shielding was used. The mean entrance surface dose of A group and B group was 26.92% lower than that of A group. The analysis of CNR and SNR was the same for both Roadmap and DSA. The use of Bismuth shielding is an alternative that can reduce the radiation impairment due to temporary hair loss and other stochastic effects that may occur after cerebrovascular intervention.

Development of a Teleoperated Manipulator System for Remote Handling of Spent Fuel Bundles

  • Ahn Sung Ho;Jin Jae Hyun;Yoon Ji Sup
    • Nuclear Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.214-225
    • /
    • 2003
  • A teleoperated manipulator system has been developed for remote handling of the spent fuel bundles. A heavy-duty power manipulator with high reduction ratio joints is used for the slave manipulator in the developed system since the handling tasks of the spent fuel bundles need power. Also, the universal type master manipulator, which has force reflecting capability, is used for precise remote manipulation. The power manipulators so frequently occur the control input saturation that the precise control performances are not achieved due to the windup phenomenon. An advanced bilateral control scheme compensating for the saturation is applied to the teleoperated manipulator system. The validity of the developed system is verified by the grid cutting and fuel transportation tasks from the mockup spent fuel bundle.

Frame Rate Up-Conversion Using Improved Weighting Factor (향상된 가중치수를 이용한 프레임율 증가 알고리듬)

  • Park, Jonggeun;Kim, Jeonghwan;Lee, Kyungjun;Jeong, Jechang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2014.11a
    • /
    • pp.68-71
    • /
    • 2014
  • 본 논문은 EBME(Extended Bilateral Motion Estimation)알고리듬에서 가중치수를 개선시켜 알고리듬을 제안하였다. 제안된 알고리듬은 EBME(Extended Bilateral Motion Estimation) MCI(Motion Compensated Interpolation)에서 고정된 확장블록을 대신하여 확장블록이 주변근처를 이동하면서 SOAD(Sum of Overlapped area Absolute Difference)를 통하여 향상된 가중치수를 찾는 알고리듬이다. 이 논문은 EBME알고리듬에 비해 PSNR(Peak Signal to Noise Ratio)이 향상된 성능을 보였다.

  • PDF

Classification of Upper Body Somatotypes according to the Age Group : Using 3D-Body Scan Data

  • Na, Hyun-Shin
    • International Journal of Costume and Fashion
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 2005
  • Two hundreds of female aged 19 years old and up were recruited to evaluate the postural changes and bilateral variation of asymmetry over age. To find out the differences among the age group, subjects were classified into 5 groups, early young age(19-29), late young age(30-39), early middle age(40-49), late middle age(50-59), and old age(60-). 35 body measurements were taken by the 3-D body scanner which allowed us to take measurements which cannot be measured using traditional methods, including the shape of a cross section, slice area surface are, and volume. Bilateral variations were observed as a function of age; Depth of scapular point level, scapular point to center back, and blade angle. Postural change of anterior cervical angle, upper anterior thoracic angle, upper posterior thoracic angle, posterior cervical angle, and center back/center front ratio were also exhibited. In each measurements, subjects were classified into normal, and abnormal group. Percentiles of abnormal in shoulder line angle, blade angle, neck point $\∼$ acromial point $\∼$ scapular point, posterior cervical angle, and upper posterior thoracic angle were increased over age group. The upper body of lateral view was classified into 3 types of posture based on the previous research; straight, erect(leaning back), and stooped(bent forward). The percentiles of subjects who have straight postures were decreased as a function of age, but those of stooped postures were increased. Subjects who have erect postures did not so. The stooped posture group shows the big cervical fossa angle, anterior cervical angle, posterior cervical angle, upper posterior thoracic angle, and the small upper anterior thoracic angle comparing to the straight and erect posture group. These results could be apply for clothing construction reflecting the changes in back, shoulder, neck, and the bilateral asymmetry according to the target age group.

An Efficient Medical Image Compression Considering Brain CT Images with Bilateral Symmetry (뇌 CT 영상의 대칭성을 고려한 관심영역 중심의 효율적인 의료영상 압축)

  • Jung, Jae-Sung;Lee, Chang-Hun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.39-54
    • /
    • 2012
  • Picture Archiving and Communication System (PACS) has been planted as one of the key infrastructures with an overall improvement in standards of medical informationization and the stream of digital hospitalization in recent days. The kind and data of digital medical imagery are also increasing rapidly in volume. This trend emphasizes the medical image compression for storing large-scale medical image data. Digital Imaging and Communications in Medicine (DICOM), de facto standard in digital medical imagery, specifies Run Length Encode (RLE), which is the typical lossless data compressing technique, for the medical image compression. However, the RLE is not appropriate approach for medical image data with bilateral symmetry of the human organism. we suggest two preprocessing algorithms that detect interested area, the minimum bounding rectangle, in a medical image to enhance data compression efficiency and that re-code image pixel values to reduce data size according to the symmetry characteristics in the interested area, and also presents an improved image compression technique for brain CT imagery with high bilateral symmetry. As the result of experiment, the suggested approach shows higher data compression ratio than the RLE compression in the DICOM standard without detecting interested area in images.