• Title/Summary/Keyword: bilateral breast cancer

Search Result 39, Processing Time 0.027 seconds

A Study on BRCA1/2 Mutations, Hormone Status and HER-2 Status in Korean Women with Early-onset Breast Cancer (젊은 한국인 유방암 환자에서 BRCA1/2 돌연변이와 호르몬 수용체, HER-2 상태에 관한 연구)

  • Choi, Doo-Ho;Jin, So-Young;Lee, Dong-Wha;Kim, Eun-Seog;Kim, Yong-Ho
    • Radiation Oncology Journal
    • /
    • v.26 no.1
    • /
    • pp.65-73
    • /
    • 2008
  • Purpose: Women with breast cancer diagnosed at an age of 40 years or younger have a greater prevalence of germline BRCA1 and BRCA2 mutations than the prevalence of women with breast cancer diagnosed at older ages. Several immunohistochemical characteristics have been identified in breast cancers from studies of Caucasian women with BRCA1/2 mutations having familial or early-onset breast cancers. The aim of this study is to determine whether early-onset breast cancer in BRCA1 or BRCA2 mutation carriers, who were not selected from a family history, could be distinguished by the use of immunohistochemical methods and could be distinguished from breast cancer in women of a similar age without a germline BRCA1 or BRCA2 mutation. We also analyzed the prognostic difference between BRCA1/2 related and BRCA1/2 non-related patients by the use of univariate and multivariate analysis. Materials and Methods: Breast cancer tissue specimens from Korean women with early-onset breast cancers were studied using a tumor tissue microarray. Immunohistochemical staining of estrogen receptor(ER), progesterone receptor(PR) and HER-2, as well as the histology and grade of these specimens, were compared. The prognostic impact of immunohistochemical and histological factors as well as the BRCA1/2 mutation status was investigated separately. Results: There were 14 cases and 16 deleterious BRCA1/2 mutations among 101 patients tested. A family history(4/14) and bilateral breast cancers(3/9) were high risk factors for BRCA1/2 mutations. BRCA1/2-associated cancers demonstrated more expression of ER-negative(19.4% versus 5.1%, p=0.038) and HER-2 negative than BRCA1/2 negative tumors, especially for tumors with BRCA1 tumors The BRCA1/2 mutation rate for patients with triple negative tumors(negative expression of ER, PR and HER-2) was 24.2%. Tumor size, nodal status, and HER-2 expression status were significantly associated with disease free survival, as determined by univariate and multivariate analysis, but the BRCA1/2 status was not a prognostic factor. Conclusion: Breast cancer that occurs in women with a germline BRCA1 or BRCA2 mutations have recognizable immunohistochemical features, which may be useful in identifying individuals that are more likely to carry germline mutations. Although the BRCA1/2 mutation status was not a prognostic factor in Korean women with early-onset breast cancer, more cases with a longer follow-up period are needed for further study.

The Surgical Impact of E-Cigarettes: A Case Report and Review of the Current Literature

  • Fracol, Megan;Dorfman, Robert;Janes, Lindsay;Kulkarni, Swati;Bethke, Kevin;Hansen, Nora;Kim, John
    • Archives of Plastic Surgery
    • /
    • v.44 no.6
    • /
    • pp.477-481
    • /
    • 2017
  • We report a case of a 51 years old female with a 25 pack year smoking history who underwent bilateral mastectomy and immediate tissue expander reconstruction for newly diagnosed right breast cancer. The patient reported herself as a non-smoker despite significant e-cigarette use, with resulting significant mastectomy skin flap necrosis and breast reconstruction failure. Little is known about the physiologic effect of e-cigarettes on wound healing and tissue perfusion. To this end, we provide an updated review of the impact of e-cigarettes on surgical outcomes. PubMed, Ovid MEDLINE, and PRS GO were searched for the terms "e-cigarette", "electronic cigarette", "e-cig", "electronic nicotine delivery system", "vaping", "surgery", "surgical", "peri-operative", "operate", "operative", and "wound healing". Abstract review of all articles was performed. 123 articles returned that contained both variants of e-cigarettes and surgery as keywords. Of those, manual assessment returned three articles which were found to be relevant to e-cigarette use in the surgical patient. No articles were found that compared perioperative complications in e-cigarette versus traditional cigarette users in humans. In conclusion, our case report depicts the potential dangers associated with e-cigarette use in the surgical patient. There is a public misconception that e-cigarettes are healthier than traditional cigarettes and as such their use may go unreported by patients. Early evidence suggests e-cigarettes may induce some of the same physiologic changes as traditional cigarettes, and may have a significant deleterious effect on wound healing.

Study on the Usefulness about Molecular Breast Imaging In Dense Breast (치밀형 유방에서 Molecular Breast Imaging 검사의 유용성에 관한 고찰)

  • Baek, Song Ee;Kang, Chun Goo;Lee, Han Wool;Park, Min Soo;Choi, Young Sook;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • Purpose Mammography is the most widely used scan for the early diagnosis since it is possible to observe the anatomy of the breast. however, The sensitivity is markedly reduced in high-risk patients with dense breast. Molecular Breast Imaging (MBI) sacn is possible to get the high resolution functional imaging, and This new neclear medicine technique get the more improved diagnostic information through It is useful for confirmation of tumor's location in dense breast. The purpose of this study is to evaluate the usefulness of MBI for tumor diagnosis in patients with dense breast. Materials and Methods We investigated 10 patients female breast cancer with dense breast type who had visited the hospital from September 1st to Octorber 10th, 2015. The patients underwent both MBI and Mammography. MBI (Discovery 750B; General Electric Healthcare, USA) scan was 99mTc-MIBI injected with 20 mCi on the opposite side of the arm with the lesions, after 20 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. Mammography was also conducted in the same posture. MBI and Mammography images were compared to evaluate the sensitivity and specificity of each case utilizing both image and two images in blind tests. Results The results of the blind test for breast cancer showed that the sensitivity of Mammography, MBI scan was 63%, 89%, respectively, and that their specificity was 38%, 87%, respectively. Using both the Mammography and MBI scan was Sensitivity 92%, specificity 90%. Conclusion This research has found that, The tumor of dense tissue that can not easily distinguishable in Mammography is possible to more accurate diagnosis since It is easy to visually evaluation. But MBI sacn has difficulty imaging microcalcificatons, If used in conjunction with mammography it is thought to give provide more diagnostic information.

  • PDF

Sarcoid-Like Reaction after Complete Remission of Malignancy: CT and 18F-FDG PET/CT Features for the Differential Diagnosis from Lymph Node Metastasis (악성종양의 완전관해 후 발생한 사르코이드증 유사 반응: 림프절 전이와의 감별진단에 유용한 CT와 18F-FDG PET/CT 소견)

  • Hyun Ji Kang;Yookyung Kim;June Young Bae;Jung Hyun Chang;Soo-Hyun Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.903-913
    • /
    • 2021
  • Purpose To identify the imaging features indicative of sarcoid-like reactions in patients with intrathoracic lymphadenopathy after complete remission of malignancies. Materials and Methods This study enrolled five patients with histopathologically confirmed sarcoid-like reactions that developed after cancer remission. The clinical features and findings of CT and 18F-fluorodeoxyglucose (FDG) PET/CT were assessed. Results The underlying malignancies included breast, nasopharyngeal, colon, and endometrial cancer and lymphoma. The time intervals between complete remission of malignancy and the diagnosis of sarcoid-like reaction ranged from 6 to 78 months. CT findings of sarcoid-like reaction included bilateral hilar and mediastinal lymphadenopathies (n = 5), pulmonary nodules (1-15 mm) with peribronchovascular, fissural, or subpleural distribution, and interlobular interstitial thickening in the lungs (n = 4). 18F-FDG PET/CT revealed hypermetabolic uptake in the mediastinal and hilar lymph nodes and both lungs in the absence of extrathoracic uptake (n = 3). The sarcoid-like reactions resolved in all patients after corticosteroid treatment. Conclusion In patients with complete remission of malignancies, newly developed bilateral hilar and mediastinal lymphadenopathies with or without pulmonary nodules of perilymphatic distribution, in the absence of recurrence at the primary tumor site and extrathoracic metastasis, may suggest a sarcoid-like reaction. Such cases warrant histologic evaluation of the lymph nodes to prevent unnecessary systemic chemotherapy.

Study on the Breast Tissue Uptake according to Body Temperature on Molecular Breast Imaging (Molecular Breast Imaging 검사 시 체온 변화에 따른 유방 섭취율에 관한 고찰)

  • Kim, Ji Hyun;Baek, Song Ee;Oh, Shin Hyun;Ham, Jun Cheol;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.20-24
    • /
    • 2019
  • Purpose Molecular Breast Imaging (MBI) scan is used in nuclear medicine, for which $^{99m}Tc-sestaMIBI$ is administered by intravenous injection. However, the breast uptake rate of $^{99m}Tc-sestaMIBI$ is less than 1% of the total dose administered, relying on blood flow conditions of organs. The purpose of this study is to evaluate the impact of changes to body temperature on the uptake of $^{99m}Tc-sestaMIBI$ in breast tissue. Materials and Methods We investigated 30 breast cancer patients who performed more than one follow-up MBI scan. All scans were acquired by Discovery 750B (Genral Electric Healthcare, USA). $^{99m}Tc-sestaMIBI$ injected with 740 MBq (20 mCi), after 60 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. The follow-up examination was then classified into 15 body temperature control group and 15 body temperature non-control group, and gained breast image in the same way as before. The breast uptake rate was analyzed in the MLO View of the opposite side of the lesion, and blind images were evaluated. Results The breast uptake rate increased by 30.31% in the body temperature control group and it was statistically significant(P<0.05), and 0.96% in the body temperature non-control group, and it was not statistically significant(P=0.955). There was a significant difference in the uptake rate between the body temperature control and the non-control group of P value of 0.01. Evaluation of blind images showed significant results in terms of the quality of the images. Conclusion Increased breast tissue uptake was observed when the subject was kept warm. When the body temperature was raised after injection, dilation of the peripheral blood vessels can be achieved. As a result, the blood flow became smooth and the breast uptake rate increased. In addition, an increase in breast tissue uptake will improve the quality of images.

Is $^{99m}Tc$-MDP Mammoscintigraphy Useful in Patients with Breast Mass Lesions? ($^{99m}Tc$-MDP 유방 스캔은 유방 종괴의 감별진단에 임상적인 유용성이 있는가?)

  • Park, Seok-Gun;Lee, Yeon-Hee;Rhyu, Jin-Woo;You, Sun-Mee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.151-160
    • /
    • 1998
  • Purpose: Piccolo et al. advocated the usefulness of $^{99m}Tc$-MDP breast scan in differential diagnosis of breast mass with high accuracy. But there are little or no follow-up studies about it as we know. We studied $^{99m}Tc$-MDP uptake pattern and lesion/background ratio in patients complaining palpable breast lesions to evaluate the clinical usefulness of $^{99m}Tc$-MDP scan. Materials and Methods: Total 34 patients were studied with physical examination, mammo-gram and $^{99m}Tc$-MDP scan prospectively. Anteroposterior and both lateral view of breast were obtained 5 minutes after iv injection of 740 MBq $^{99m}Tc$-MDP. Breast uptake pattern of $^{99m}Tc$-MDP was analyzed by a grade system: 0=no uptake, grade 1=bilateral diffuse uptake, grade 2=asymmetric faint uptake, grade 3=focal hot uptake. 20 cases were pathologically confirmed by excision biopsy or aspiration biopsy. 14 cases were normal in physical examination and mammogram. Results: Pathologic results showed 7 carcinomas, 6 benign solid tumors, and 7 fibrocystic changes. Grade 3 pattern of $^{99m}Tc$-MDP uptake was noted in 4/7 carcinomas, 3/6 benign solid tumors, and 1/7 fibrocystic changes. Grade 2 pattern was 217, 0/7, 3/7 respectively. The average L/B ratio was 1.66 in carcinomas, 1.68 in benign solid masses, 1.20 in fibrocystic diseases, 1.05 in normal patients. L/B ratio was higher in carcinoma and benign mass groups than in fibrocystic change and normal control groups(p=0.005). But there was no statistical difference between L/B ratio of malignant mass group and benign mass group. Conclusion: $^{99m}Tc$-MDP scan is not suitable to routine clinical use for breast mass diagnosis. It might be used in limited conditions when whole body bone scan is planned.

  • PDF

Evaluation of the usefulness of Halcyon VMAT treatment plan through comparison with tomotherapy in bilateral breast cancer radiation therapy. (양측 유방암 방사선치료 시 토모테라피와의 비교를 통한 Halcyon VMAT 치료계획의 유용성 평가)

  • LIM JUN TAEK;PARK JU YOUNG;PARK SU YEON;JEON SEONG JIN;PARK TAE YANG;HWANG DA JIN
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.83-92
    • /
    • 2022
  • Purpose: To evaluate usefulness of Tomotherapy and Halcyon VMAT treatment in radiation therapy for bi-breast cancer Materials and Methods: For 10 patients with bi-breast cancer, volumetric modulated arc therapy(VMAT) treatment plan was established using helical Tomotherapy(Accuray. USA) with field width of 5.0-cm and pitch of 0.287, and Halcyon(Varian Medical System, Palo Alto, CA, Version 3.0 USA) of 6arc and 8arc. Prescribed dose was 42.4 Gy/16, and V 40.3Gy of Planning Target Volume(PTV) was 90%. The quality of plan was evaluated by comparing the dose to tumor and normal organs, and the efficiency was evaluated by comparing total MU and beam on time. Results: About three treatment plans(Tomotherapy, Halcyon 6Arc VMAT, Halcyon 8Arc VMAT) , the mean homogeneity index(H.I) of PTV were 1.07, 1.10, 1.11, and the mean conformity index(C.I) of PTV were 1.21, 1.16, 1.17, respectively. The average value of the dose assessment item for a normal organ is V 5Gy(%) of both lung was 36.3, 31.2, 29.7, and V 15Gy(%) were 18.6, 15.5, 14.6, respectively. The mean heart dose(Gy) were 4.17, 2.69, 2.51. Total MU were (7498.6, 2494.2, 2471.5), and beam on time(sec) were 462.5, 195.4, 198.0. Conclusion: Halcyon VMAT showed similar quality of treatment plan compared to helical Tomotherapy, while also protecting normal organs. In addition, the efficiency of radiotherapy increased due to a decrease in Beam On Time and MU.

Usefulness of $^{18}F$-FDG Fusion PET for Diagnosing an Early Stage Cancer (조기 암 진단을 위한 $^{18}F$-FDG Fusion PET의 유용성)

  • Jeon, Jae-Hwan;Kim, Byeong-Jin;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.145-149
    • /
    • 2010
  • Purpose: Recently, $^{18}F$-FDG Fusion PET which has a high sensitivity for diagnosing cancer is being used for purpose of health examination. This study is to demonstrate that $^{18}F$-FDG fusion PET study is useful for diagnosing an early stage cancer. Materials and Methods: This research has been conducted with 2790 patients visited Seoul National University Hospital Healthcare System (SNUHHS) for $^{18}F$-FDG fusion PET study for a health examination from February, 2004 to December 2008. PET/CT images were acquired from skull base to femur after 1 hour from injecting $^{18}F$-FDG 0.14 mCi/kg to the patients. GEMINI GS (Philips, Netherlands) was used for scanning. Results: From February 2004 to December 2008, $^{18}F$-FDG Fusion PET study was performed for 99,009 patients among all patients who visited SNUHHS and 2,790 patients was performed. Diagnostic rate for malignant cancer was 0.95% for the patients who were not examined by $^{18}F$-FDG Fusion PET study. 1.94% was for the patients who were. The rate of malignant tumor was showed 10% and benign tumor was 90% among 542 patients who showed abnormality in the PET/CT images. Types and rates of malignant tumor showed thyroid cancer: 31.5%, lung cancer: 14.8%, stomach cancer: 9.3%, rectum cancer: 3.7%, breast cancer: 3.7%, metastasis cancer: 16.7%. Nonspecific lymph node in the mediastinum, physiologic uptake in the colon, diffuse mild hypermetabolism in bilateral thyroid gland were shown as a benign tumor. Conclusion: The diagnostic rate of malignant tumor with $^{18}F$-FDG Fusion PET for a purpose of health examination was relatively higher than general medical examination. Consequently, it is superior and useful for applying $^{18}F$-FDG Fusion PET study for health examination.

  • PDF

Comparison of Tc-99m-Tetrofosmin and Tc-99m-MIBI Scintimammography in Differential Diagnosis of Breast Mass (유방종양의 감별진단에서 Tc-99m-Tetrofosmin과 Tc-99m-MIBI 유방신티그라피의 비교)

  • Park, Jung-Mi;Choi, Joon-Young;Lee, Kyung-Han;Choi, Yong;Choe, Yearn-Seong;Kim, Sang-Eun;Kim, Byung-Tae;Nam, Seok-Jin;Yang, Jeong-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.393-402
    • /
    • 2000
  • Purpose: Tc-99m-MIBI (MIBI) and Tc-99m-Tetrofosmin (TF) are commonly used for scintimammog (SMM). We compared the diagnostic ability of SMM using Tc-99m-MIBI and Tc-99m-TF for the diagnosis of breast mass. Materials and Methods: The study subjects were comprised of 123 breast lesior 86 normal breasts of 114 patients who underwent SMM. Bilateral prone images and anterior supine images obtained at 5 minutes and 1 or 3 hours after intravenous injection of 740 MBq of either MIBI or TF. of tumors were not significantly different between the MIBI and TF groups. First, two observers read the SMM without clinical information (1st interpretation), then read again with information about location (2nd interpretation). Sensitivity and specificity of each radiopharmaceutical for the diagnosis of cancer were evaluated in terms of image acquisition time, tumor size, and location. Results: The SMM a good agreement between two observers for 1st and 2nd interpretation, except for TF SMM at 3 hr. first interpretation, the sensitivities at 5 min, 1 hr, and 3 hr were not significantly different between MIBI TF SMM (81.6%, 80.0%, 60.9% in MIBI vs. 88.9%, 80.6%, 42.9% in TF), although the sensitivities of images were significantly lower than 5 min images in both MIBI and TF SMM. The specificity of TF at was superior to that of MIBI (81.5%, 90.0%, 82.9% in MIBI vs. 96.7%, 100%, 90.0% in TF, p<0.01 MIBI TF at 5 min). For the second interpretation with information of mass location, the sensitivities at 3 hr were significantly lower than 5 min images (86.8%, 86.7%, 78.3% in MIBI vs. 88.9%, 93.5%, 57.1% between MIBI and TF SMM. However, there was no significant difference in the specificity (60.0%, 75.0% for MIBI vs. 86.7%, 100%, 100% for TF). MIBI and TF SMM showed lower sensitivities for the with less than 1 cm than tumors with more than 1 cm. However, the location of tumors did not sensitivity and specificity between MIBI and TF SMM. Conclusion: The ability for the differential of breast tumor is similar between MIBI and TF SMM, and delayed image is not necessary. TF may be than MIBI considering the specificity of SMM without clinical information and labeling convenience.

  • PDF