• Title/Summary/Keyword: bi-response pattern

Search Result 14, Processing Time 0.022 seconds

A Simple and Fast Anti-collision Protocol for Large-scale RFID Tags Identification

  • Jia, Xiaolin;Feng, Yuhao;Gu, Yajun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.4
    • /
    • pp.1460-1478
    • /
    • 2020
  • This paper proposes a novel anti-collision protocol for large-scale RFID tags identification, named Bi-response Collision Tree Protocol (BCT). In BCT, two group of tags answer the reader's same query in two response-cycles respectively and independently according to the bi-response pattern. BCT improves the RFID tag identification performance significantly by decreasing the query cycles and the bits transmitted by the reader and tags during the identification. Computation and simulation results indicate that BCT improves the RFID tag identification performance effectively, e.g. the tag identification speed is improved more than 13.0%, 16.9%, and 22.9% compared to that of Collision Tree Protocol (CT), M-ary Collision Tree Protocol (MCT), and Dual Prefix Probe Scheme (DPPS) respectively when tags IDs are distributed uniformly.

Frequency Domain Pattern Recognition Method for Damage Detection of a Steel Bridge (강교량의 손상감지를 위한 주파수 영역 패턴인식 기법)

  • Lee, Jung Whee;Kim, Sung Kon;Chang, Sung Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.1 s.74
    • /
    • pp.1-11
    • /
    • 2005
  • A bi-level damage detection algorithm that utilizes the dynamic responses of the structure as input and neural network (NN) as pattern classifier is presented. Signal anomaly index (SAI) is proposed to express the amount of changes in the shape of frequency response functions (FRF) or strain frequency response function (SFRF). SAI is calculated using the acceleration and dynamic strain responses acquired from intact and damaged states of the structure. In a bi-level damage identification algorithm, the presence of damage is first identified from the magnitude of the SAI value, then the location of the damage is identified using the pattern recognition capability of NN. The proposed algorithm is applied to an experimental model bridge to demonstrate the feasibility of the algorithm. Numerically simulated signals are used for training the NN, and experimentally-acquired signals are used to test the NN. The results of this example application suggest that the SAI-based pattern recognition approach may be applied to the structural health monitoring system for a real bridge.

Top and Bottom Symmetrical Loop Antenna for Multi-media Devices (멀티미디어단말기용 상하대칭 루프 안테나)

  • Shin, Cheon-Woo
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.3
    • /
    • pp.414-422
    • /
    • 2011
  • The paper is for top and bottom symmetrical phase controlled loop antenna using for multi-media devices. We developed a top and bottom phase control loop pattern arrangement methods for loop antenna in mobile devices like as a cell phone and PCS, WCDMA. In the loop antenna pattern, arrange close adhesive the loop antenna pattern $180^{\circ}$ cycle in wave length, the radiated electro-magnetic wave from close adhesive loop pattern in $180^{\circ}$ become to coherent wave than the phase controlled loop antenna has high efficiency and high radiation gain. To acquire a wide band width on phase controlled loop antenna, we arrange a top and bottom symmetrical architecture loop pattern that bas a $180^{\circ}$ wave length in each layer. Top and bottom each layer bas a U form pattern separated $90^{\circ}$ wave length each other. This architecture cause a well balanced electro-magnetic flow control that acquired wide bandwidth resonance response in loop pattern antenna. In experiment, we designed a WCDMA mobile multi-media antenna in $40mm{\times}6mm$ area thickness 0.2mm, in that passive experiment the radiation efficiency is over 50% and over 0dBi radiation average gain was acquired, in the active experiment in real multi-media device we acquired -4dBi average gain and 43% transmit/receive efficiency.

Seismic response of substandard RC frame buildings in consideration of staircases

  • Karaaslan, Ayberk;Avsar, Ozgur
    • Earthquakes and Structures
    • /
    • v.17 no.3
    • /
    • pp.283-295
    • /
    • 2019
  • During the seismic performance assessment of existing buildings, staircases are generally not taken into account as structural members but as dead load. Staircases, as secondary structural members, not only serve for connecting successive floors but also provide considerable amount of strength and stiffness to the building which can modify its seismic behaviour considerably. In this parametric study, the influence of staircases on the seismic response of substandard RC frame buildings which differ in number of storey and span, presence of staircase and its position has been examined. Modal Analyses and bi-directional Non-Linear Time History Analyses (NLTHA) were conducted to compare several engineering demand parameters (EDPs) such as inter-storey drift ratio (ISDR), floor accelerations, modal properties, member shear forces and plastic hinge distribution. Additionally, short column effect, variation in shear forces of columns that are attached to the staircase slab, failure and deformation in staircase models have also been investigated. As the staircase was considered in the analytical model, a different damage pattern can be developed especially in the structural components close to staircase.

Comparative volumetric and clinical evaluation of peri-implant sulcular fluid and gingival crevicular fluid

  • Bhardwaj, Smiti;Prabhuji, Munivenkatappa Lakshmaiah Venkatesh
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.5
    • /
    • pp.233-242
    • /
    • 2013
  • Purpose: Peri-implant sulcular fluid (PISF) has a production mechanism similar to gingival crevicular fluid (GCF). However, limited research has been performed comparing their behavior in response to inflammation. Hence, the aim of the present study was to comparatively evaluate PISF and GCF volume with varying degrees of clinical inflammatory parameters. Methods: Screening of patients was conducted. Based on the perimucosal inflammatory status, 39 loaded implant sites were selected from 24 patients, with equal numbers of sites in healthy, peri-implant mucositis, and peri-implantitis subgroups. GCF collection was done from age- and sex-matched dentate patients, selected with gingival inflammatory status corresponding to the implant sites. Assessment of the inflammatory status for dental/implant sites was performed using probing depth (PD), plaque index/modified plaque index (PI/mPI), gingival index/simplified gingival index (GI/sGI), and modified sulcular bleeding index (BI). Sample collection was done using standardized absorbent paper strips with volumetric evaluation performed via an electronic volume quantification device. Results: Positive correlation of the PISF and GCF volume was seen with increasing PD and clinical inflammatory parameters. A higher correlation of GCF with PD (0.843) was found when compared to PISF (0.771). PISF expressed a higher covariation with increasing grades of sGI (0.885), BI (0.841), and mPI (0.734), while GCF established a moderately positive correlation with GI (0.694), BI (0.696), and PI (0.729). Conclusions: Within the limitations of this study, except for minor fluctuations, GCF and PISF volumes demonstrated a similar nature and volumetric pattern through increasing grades of inflammation, with PISF showing better correlation with the clinical parameters.

Critical Low Temperature and Response of Behavioral Tolerance in Red Seabream Pagrus major fingerlings Exposed to Cold Shock (저온 충격에 노출된 참돔 Pagrus major 치어의 임계 저 수온 및 행동 내성 반응)

  • Yoon, Sung Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.575-584
    • /
    • 2021
  • The critical low temperature and response of the behavioral tolerance of red sea bream Pagrus major fingerlings were determined using the continuous behavior monitoring system (CBMS). The behavior of the experimental organisms was observed by decreasing the water temperature by 2.0℃ and 4.0℃ every 12 hours and 24 hours in the range of 8.0-20.0℃. An unstable behavior pattern was observed in red seabream fingerlings exposed to water temperatures below 12.0℃, in which the swimming activity decreased and repeatedly stopped, regardless of the exposure time and water temperature fluctuation. The swimming ability of the organisms exposed to 8.0-10.0℃ decreased sharply, and the behavior of staying at the bottom of the test tank was observed. Only 50 % of the organisms survived due to the low-temperature stress, and all individuals died within six hours after the cold shock. In addition, the behavior index (BI) decreased rapidly, and the amplitude change of the coefficient of variation (CV) was found to have a greater variation than the other water temperatures (p<0.05). Low-temperature stress of red sea bream is promoted at 12.0℃, and it is interpreted as the tolerance limit, which can induce a sublethal response of the organisms exposed to cold shock of 8.0-10.0℃.

Effect of Multi-Channel Vibration Stimulation on Somatosensory Sensibility (다채널 진동자극이 체성감각에 미치는 영향)

  • Bae, Tae-Soo;Kim, Hyung-Jae;Kim, Sol-Bi;Chang, Yun-Hee;Kim, Shin-Ki;Mun, Mu-Seong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.651-656
    • /
    • 2011
  • Although prosthetic training was received, most of amputees mainly depend on visual feedback to use prostheses, not on cutaneous and proprioceptive sensibility. Our objective of this study was to determine if there are changes in the somatosensory sensibility of amputees compared to non-amputees using multi-channel vibration stimulation system. One transradial amputees and ten non-amputees were involved. To investigate changes of residual somatosensory sensibility at stump, we set up custom-made vibration stimulation system including eight actuators (4 medial and 4 lateral) and GUI-based acquisition system. The results showed that there was similar pattern of subjective response at most of channels among group as stimulation increases. However, amputees' subjective response at channel 8 for 238Hz vibration was more sensitive than that of healthy persons. With respect to channels, response at channel 4 (medial) corresponding region to flexor carpi ulnaris for transradial amputees was most sensitive than other channels. In addition, sensitivity of four medial channels was on average about 0.5 scale than that of four lateral channels. Somatosensory sensibility was amputee, women, and men in sensibility order.

Seismic Performance and Retrofit of Reinforced Concrete Two-Column Piers Subjected to Bi-directional Cyclic Loadings (이축반복하중을 받는 2주형 철근콘크리트 교각의 내진성능과 보강)

  • Chung, Young-Soo;Park, Chang-Kyu;Lee, Ho-Yul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.47-55
    • /
    • 2006
  • Seismic performance and retrofit of reinforced concrete (RC) two-column piers widely used at roadway bridges in Korea was experimentally evaluated. Ten two-column piers that were 400 mm in diameter and 2,000 mm in height were constructed. These piers were subjected to hi-directional cyclic loadings under a constant axial load of $0.1f_{ck}A_g$. Test parameters were the confinement steel ratio, loading pattern, lap splice of longitudinal reinforcing bars, and retrofitting method. Specimens with lap-spliced longitudinal bars were retrofitted with steel jacket, pre-stressing steel wire, and steel band. Test result showed that while the specimens subjected to bi-directional lateral cyclic loadings which consisted of two main amplitudes in the transverse axis and two sub amplitudes in longitudinal axis, referred to as a T-series cyclic loadings, exhibited plastic hinges both at the top and bottom parts of the column, the specimens subjected to bi-directional lateral cyclic loadings in an opposite way, referred to as a L-series cyclic loadings, exhibited a plastic hinge only at the bottom of the column. The displacement ductility of the specimen under the T-series loadings was bigger than that of the specimen under the L-series loadings. Specimen retrofitted with pre-stressing steel wires exhibited poor ductility due to the upward shift of the plastic hinge region because of over-reinforcement, but specimens retrofitted with steel jacket and steel band showed the required displacement ductility. Steel band can be an effective retrofitting scheme to improve the seimsic performance of RC bridge piers, considering its practical construction.

Comparison of Digestive Function Among Rabbits, Guinea-Pigs, Rats and Hamsters. II. Digestive Enzymes and Hindgut Fermentation

  • Yu, Bi;Chiou, Peter Wen-Shyg;Kuo, Chung-Yi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.11
    • /
    • pp.1508-1513
    • /
    • 2000
  • The aim of this trial was to study the response of laboratory animals including omnivores (rats) and herbivores (rabbits, guinea pigs and hamsters) to the same level of dietary fiber on their digestive enzymes and hindgut fermentation. Ten weanling animals of each of four species, rabbits, guinea-pigs, rats and Syrian hamster, were fed a basal diet of 18% crude protein and 10% crude fiber for six weeks. The digesta and tissue of each intestinal segment were collected to measure the activity of digestive enzymes. Rabbits contained the highest secreted pepsin activity in the stomach, whereas rats contained the highest protease and ${\alpha}-amylase$ activity in the small intestine, and lower fibrous hydrolases in the hindgut than rabbits, guinea pigs and hamsters. The total VFA productions in the caecum and colon were highest in rats, followed by hamsters and rabbits, while the guinea pigs contained the lowest VFA and a different pattern of VFA molar ratio from the other laboratory animals. The degree of hindgut fermentation in these laboratory animals was in reverse to the trend for their fiber digestion.

Effect of firing temperature and degree of lamination on microstructure and electrical properties of ZnO-based multilayered ceramic chip varistors (소성온도와 적층수가 ZnO계 적층형 바리스터의 미세구조와 전기적 특성에 미치는 영향)

  • Kim, Chul-Hong;Kim, Jong-Hwa;Kim, Jin-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.126-129
    • /
    • 2003
  • The electrical properties of a ZnO-based multilayered chip varistor (abbreviated as MLV) were studied as functions of firing condition and the degree of lamination. The fundamental varistor characteristics such as nonlinear coefficient and breakdown voltage were independent of the degree of lamination. As the number of the laminated ceramic sheets increased, however, not only the energy handling capability but also the capacitance and the leakage current which are relevant to delayed response to the voltage surge and the pre-breakdown energy loss, respectively, increased. With the increase of firing temperature between $950^{\circ}C$ and $1150^{\circ}C$, both the capacitance and the leakage current of the MLV increased due mainly to the grain growth of ZnO and the volatilization of $BiO_2O_3$. High performance MLVs with clear electrode pattern were obtained at the firing temperature range of $l000{\sim}1050^{\circ}C$ in this experiment.

  • PDF