• 제목/요약/키워드: bezalkonium chloride

검색결과 2건 처리시간 0.018초

Metanil Yellow에 의한 4급 Amine류의 Ino Pair 추출 흡광도 정량 (II) - Benzalkonium Chloride, Cetylpyridinium Chloride 및 Dimenhydrinate의 정량 (Spectrophotometric Determination of Ion Pair Extraction of Quaternary Amines with Metanil Yellow)

  • 김영수;최종환
    • 약학회지
    • /
    • 제35권1호
    • /
    • pp.15-21
    • /
    • 1991
  • Quaternary amines which are widely used as medicines are nitrogen compounds. Metanil yellow(MY) and benzalkonium chloride(BKC) were mixed and added to 10ml of the buffer solution and then the solution was shaken for 5 minutes. The maximum absorption wavelength of the reaction product was 402 nm. Dichloromethane was the best extracting solvent among the several organic solvents and the most suitable pH range was 2~8. When the BKC-MY calibration curve was made in the best experimental condition, the Lambert-Beer's law was obeyed in the range of BKC concentration of 2$\times$$10^{-6}$~9$\times$$10^{-6}$M by UV spectrophotometer. This method was possible to determine quaternary ammonium salts in the pharmaceutical preparation.

  • PDF

Analysis of Cationic Surfactants in Cosmetics By Reverse phase Ion-Pair Chromatigraphy with Suressed Conductivity Detector and UV Detector

  • Jong-Keun Choi;Jae
    • 대한화장품학회지
    • /
    • 제23권3호
    • /
    • pp.161-167
    • /
    • 1997
  • Determination of several cationic surfactants in cosmetics has been investigated. Reverse phase ion pair chromatography was used to identify and quantitate cationic surfactants. Cationic surfactants analyzed in this experiment were cetylpyridium chloride, stearyltrimetylammonium chloride, bezalkonium chloride, benzyldicethylcetylammonium chloride, and bihenyltrimethyl ammonium chloride. The separation was achieved on a reverse phase coumn with 10mM HCl-acetonitrile eluent. In this condition, the most of cationic surfactants with exception of CPC and CTAC respectively with suppressed conductivity detector and UV detector connected in series. The calibration curves obtained by plotting the peak areas of the cationic surfactants were linear at levels ranging from 0.005 to 0.1% correlation coefficient, r=0.9988. The detection limits were 1 to 5ppm in sample solution. The average recoveries of cationic surfactants added to hair treatment cream and hair rinse in three to five experiments were 96.7 105.2% and relative standard deviations were 1.1-3.8%. The case that there were CPC and CTAC in same solution was also tested. CPC and CTAC which couldn't be separated on reverse phase column were quantitated with suppressed conductivity detector and UV detector connected in series. Recovery of CPC and CTAC were 101.6 and 89.2% respectively. The proposed method was applied to the determination of cationic surfactants in commercial hair treatment cream.

  • PDF